OmniSite OmniBeacon GuardDog User manual

USER GUIDE
Copyright 2016, OmniSite
All Rights Reserved, Ver 1.0
Email: [email protected]
GUARDDOG VERSION
™

2
Technical Support
Technical Specications
Introduction
Operating Modes
Internal Components
Unpacking
External Components
Installation
Safety Precautions
Panel Mounting
Hole Sealing Kit
Pole Mounting
Electrical Connection - 110 –120VAC
Six Position Wiring Diagram - 110–120VAC
Electrical Connection - 12VDC
CONTENTS
5
6
7
8
10
11
12
14
15
18
20
22
24
26
28

3
Six Position Wiring Diagram - 12 VDC
Mounting Battery Backup
Activation
Connecting to Cellular Service
GuardDog Website Setup
Create Callout List
Independent Text Messaging
SMS Conguration
SMS Commands
SMS Messages
LED Status Indicators
System Power
Alarm Inputs
Troubleshooting
Product Safety, Use and Limited Warranty
30
32
34
36
37
38
42
44
51
54
56
57
58
60
62
phone (317) 885-6330 x3 online www.OmniSite.com

4
WARNING: Not to be used as a visual public
mode alarm notication appliance
WHAT DOES THIS MEAN?
To prevent misapplication of a visual signal appliance, it is the
manufacturer’s responsibility to warn the installer in the eld
and Authority Having Jurisdiction (AHJ) of what would be an
inappropriate use of the product.
“Public Operating Mode” and “Notication Appliance” as dened in
the National Fire Alarm Code, NFPA 72 is as follows:
Public Operating Mode - Audible or visible signaling to
occupants or inhabitants of the area protected by the re alarm
system.
Notication Appliance - A re alarm system component such as a
bell, horn, speaker, light, or text display that provides audible, tactile,
or visible outputs, or any combination thereof. In other words, this
device should not be used as a component of a commercial re
alarm system.

5
Technical Support
Have questions or comments about your OmniBeacon™
Alarm Light? Please contact:
FREE WORLD CLASS SUPPORT!
203 W. Morris Street
Indianapolis, IN 46225
support@omnisite.com
317-885-6330 x3
www.OmniSite.com

6
• Dual Input Alarm Channels: (1) 12VAC/VDC to 120VAC/
VDC, Opto-isolated to 1500VAC input and (1) Dry Contact
input
• Backup Battery: External 6VDC Sealed Lead Acid, 1.3 AH,
Re-chargeable, .187” Faston spades
• Operating Temperature: -20º to 150º F
• Operating Humidity: 0-90% RH, non-condensing
• Alarm Light Bulb: Super bright LEDs, long-life
• Alarm Light Annunciator: 2.8kHz, 85dB
• Alarm Light State: Pulses LEDs and Annunciator at 3Hz when
input #1 is in alarm
• Cellular Radio: 4G LTE CAT-1
•Certifications: FCC Parts 15, 22, 24; RoHS compliant; IC:
RSS-132 & 133
• Antenna: Integrated, on board
• Input Power: 120VAC +/-20% @ 0.5A max
12VDC Version: 12VDC +/-15% @ 1.5A max
• Enclosure: NEMA 4 equivalent rating for direct mounting
indoors or outdoors.
• Dimensions: 5”W round base x 5”H
• Weight: 1 lb.
• Protection: US Patent #7,228,129 and #7,778,633
Technical Specications

7
World’s Best Alarm Beacon!
How does the OmniBeacon™Work?
You’ve just purchased the best! The OmniSite OmniBeacon™
combines a wireless cellular transmitter, LED light source, and
alarm siren into one convenient weather protected package.
No matter your location, receive alerts from your equipment
when you need it most.
The OmniBeacon™ can be congured to work for you in two
different modes:
(1) Powered by our GuardDog Intelligent Website
(2) Independent text messaging mode
Introduction

8
When congured in this way, the OmniBeaconTM will report
events to the GuardDog website. GuardDog can be told to
redistribute alarm events to any number of users via text
messaging, email, or computer simulated voice message.
You can also login to see your device on a Google map and
GuardDog will keep a 2 year history of all events. For more
information on how to setup and use this mode see page 37.
OPTION 1 | GuardDog Intelligent Website
phone (317) 885-6330 x3 online www.OmniSite.com
Operating Modes

9
OPTION 2 | Text Messaging Backup
If the OmniBeacon™ CANNOT CONNECT to the GuardDog
website for any reason, then it can be congured to directly
send text messages to (3) phone numbers, and then bypass the
GuardDog website.
In this mode, the OmniBeacon sends the text messages
and does not rely on the GuardDog website to relay alarm
information.
This is an “industry rst” feature brought to you by OmniSite
providing peace of mind that you always receive critical alarms.
For more information on how to setup and use this mode,
see page 42.
Operating Modes (Cont’d)

12
4
3
Internal components
(1) LED Multicluster
Light Stick
(2) 12VDC Power Supply
(3) Cellular Transmitter
& Battery Charger
(4) Status LED
Indicator Light
In eld service is not required for OmniBeacon™
internal components.
10

11
After unpacking your OmniBeacon™, examine it for damage
that may have occurred in transit. If the device has been
damaged, do not attempt to install or operate it.
File a claim immediately with the carrier stating the extent of
the damage. Carefully check all bags, shipping labels, and tags
before discarding them.
Unpacking

12
(1) OmniBeacon™
(2) Control Panel Gasket (x1)
(3) Quick-Connect Field Wiring Connector
(4) Backup Battery (with Mounting Pocket)
(5) Impact Guard Cage
(6) Conduit Nut 3/4” (x1)
(7) #10 Self Drilling/Tapping Screws (x2)
(8) Quick Connect Terminals (x2)
(9) Stainless 8-32 Screw and Nut (x4)
(10) #8 Neoprene Sealing Washers (x4)
(A) Large Hole Sealing Kit used to ll/cover large hole in
electrical panel (Optional)
External components
1
2
3
4
6
5
10
7
8
9
12

13
TO COME
1
2
3
4
6
5
10
7
8
9
13

14
SAFETY MESSAGE TO INSTALLERS, USERS, AND
MAINTENANCE PERSONNEL
It is important to follow all instructions shipped with this
product. This device is to be installed by a trained electrician
who is thoroughly familiar with the National Electrical Code/
Canadian Electrical Code and will follow the NEC/CEC
Guidelines as well as local codes.
Installation of this device should be lead by the direction of the
facilities engineer and the safety engineer. In addition, listed on
the next page are some important safety precautions.
Failure to follow all safety precautions and instructions may
result in property damage, serious injury, or death.
phone (317) 885-6330 x3 online www.OmniSite.com
Installation

15
Safety Precautions
• Read and understand all instructions before installing or
operating the OmniBeacon™.
• Disconnect the OmniBeacon™ from the power supply
before any installation or maintenance is performed.
• After installation, test the OmniBeacon™ to ensure that it is
operating properly.
• After testing is complete, provide a copy of this instruction
sheet to all operating personnel.
• Establish a procedure to routinely check the OmniBeacon™
installation for integrity and proper operation.
• The product nameplate should not be obscured in any way.

16
1
2
3
4
5
6
7
Panel Mounting Overview

17
(1) OmniBeacon™
(2) Stainless Steel 8-32 Screw & Nut (x4)
(3) Control Panel Gasket
(4) Chase Nipple
(5) Control Panel Surface
(6) Conduit Nut 3/4” (x1)
(7) #8 Neoprene Sealing Washers (x4)

18
Panel Mounting Instructions
DO NOT SIDE MOUNT OMNIBEACON™.
Mount the OmniBeacon™ in the vertical orientation only.

19
(1) Using the base foam gasket as a drilling template, mark
hole locations in 5 places. Drill or punch four 3/16” holes
and one 3/4” hole.
(2) Place the gasket on a mounting surface and line up four 3/16”
holes for the #8 machine screws.
(3) Remove the ¾” conduit nut from the chase nipple.
It will be secured in step (7).
(4) Pass the OmniBeacon wires and chase nipple through the
¾” hole. Line up four 3/16” holes with the mounting feet.
(5) Locate the four 8-32 Stainless Steel machine screws and
four #8 Neoprene Sealing Washers.
(6) Insert the 8-32 Stainless Steel machine screws into the #8
Neoprene Sealing Washers, and then insert this into the
four base feet. Attach the four 8-32 Stainless Steel nuts
from the underside. Tighten the nuts snuggly.
(7) Feed wires through the ¾” conduit nut and tighten
to chase nipple.
(8) Refer to Electrical Connections section for wiring details.

20
OmniBeacon™ Large Hole Sealing Kit (Optional)
USED TO FILL/COVER LARGE
HOLE IN ELECTRICAL PANEL
phone (317) 885-6330 x3 online www.OmniSite.com
Figure #1 – Correct installation shows sandwiching metal plate between (2)
rubber gaskets to cover a large hole in the electrical control panel.
Use these (4) Feet to Mount OmniBeaconTM
when using adaptor plate, using supplied
screws
Top Rubber Gasket supplied with
OmniBeaconTM
Metal Hole Cover Plate
Bottom Rubber Gasket supplied with
Metal Cover Plate
Table of contents
Popular Security System manuals by other brands

NAPCO
NAPCO XP-600 - 9-16-1997 user guide

Lorex
Lorex LW2002W Series Specifications

Federal Signal Corporation
Federal Signal Corporation 2-240 Installation, operation & service manual

Garmin
Garmin GPSMAP 800 Series Operator's manual

Perenio
Perenio PEKIT01 quick start guide

SECO-LARM
SECO-LARM ENFORCER EVT-PB1-V1TSQ installation manual