CX-Thermo Support Software Ver. 4.0 EST2-2C-MV4
CX-Thermo Support Software Ver. 4.0
EST2-2C-MV4
Monitoring/Setting Support Software for E5CN/CN-H, E5AN/AN-H,
E5EN/EN-H, E5ZN, E5@R/@R-T, and EJ1 Temperature Controllers
Enabling Faster Parameter Setup, Device Adjustment, and
Maintenance
•Enables editing and batch-downloading parameters from a
personal computer, reducing the work required to set parameters.
Usability is improved with table-formatted parameter editing from
version. 4.0.
•Supports Trend Monitoring:
Monitor data (PV,SP,MV,PID parameter, Alarm ON/OFF, etc.) for
up to 31 E5@N/@N-H Temperature Controllers.
Connect up to 64 EJ1N, 17 EJ1G, or 16 E5ZN Temperature
Controllers. (The Temperature Controllers must be from the same
series.)
•Supports parameter masks to hide parameters unnecessary to
display. (Supported only by the E5@N/@N-H and E5@R/@R-T).
•Logic operations enable setting inputs from external inputs (event
inputs) or temperature status, outputs to external outputs (control or
auxiliary outputs), and changing operating status with ON/OFF
delays.
(Supported only by the E5@N/@N-H).
•Easy adjustment of control performance by fine-tuning.
✽Fine-tuning instructs the CX-Thermo to calculate a PID parameters by
directly inputting commands to improve response.
Ordering Information
List of Models
Specifications
Note: "E5@N" indicates the upgraded versions of the E5CN, E5AN, and E5EN.
Name Model
CX-Thermo Support Software EST2-2C-MV4
Compatible
devices
Temperature
Controllers
E5CN (from April 2004)
E5AN, E5EN (from Feb 2005),
E5CN-H, E5AN-H, E5EN-H
E5AR, E5ER, E5AR-T, E5ER-T
E5ZN
EJ1N-TC4, EJ1N-TC2, EJ1N-HFU (CeliuXº)
EJ1G-TC4, EJ1G-TC2, EJ1G-HFU (CelciuXº Gradient Temperature Control)
G3ZA (only when connected to EJ1N-TC4, EJ1N-TC2, EJ1G-TC4, EJ1G-TC2)
Note: Models with DeviceNet communications are not supported.
Personal
computer
system
requirements
OS Windows 2000 (service pack 3 or higher), XP, or Vista (Japanese or English version)
CPU 300 MHz min.
Memory 128 MB min.
Harddisk 300 MB min. available space
CD-ROM One CD-ROM drive min.
Monitor SVGA (800 ×600) min.
Communications
ports
•RS-232C port, or USB port, 1 port min.
Connection method •An E58-CIFQ1 USB-Serial Conversion Cable is required to connect a computer to the setup tool port the
E5@N, E5@N-H, or EJ1.
•A K3SC Interface Converter is used to connect a computer to models with RS-422/RS-485.
•An E58-CIFIR USB-Infrared Conversion Cable is required to wirelessly connect a computer to models with
infrared communications (E5AN-H or E5EN-H).