Page 6
HID Lights High Intensity Discharge Lights
(Single Canister battery system is standard for HID lights):
Battery Specifications:
Battery Canister Specifications:
Charger Specifications for HID lights:
Canister Mounting Options:
Light Type Item # Bulb Type Burn Time* Ave. bulb life** Output Focus Beam Angle Restart
Light Type Item # Capacity Cell Types Type
Light Type Type Depth Rating*** Connectors Material Cord Dimensions Weight
Type Item # Primaries Secondaries Charge time**** Float Charger Approval End of Charge
Light Type Backplate Waist Nesting between Cylinders Hand Held Manifold Area Butt mount
Phantom 10w HID Light L197HM10-K 10w HID 270 minutes/4Ah battery 1000 hrs. 450 Lm Fixed 6 degrees 5 sec.
Phantom 10w HID Light L197HM10-K8 10w HID 540 minutes/8Ah battery 1000 hrs. 450 Lm Fixed 6 degrees 5 sec.
Phantom HID Flashlight L10wFL 10w HID 120 minutes/1.5Ah batteries 1000 hrs. 450 Lm Fixed 6 degrees 5 sec.
Phantom 10w HID L197HM10 13.2V, 4Ah Battery Pack Rechargeable Li-Ion
Phantom 10w HID L197HM10-K8 13.2V, 8AH Battery Pack Rechargeable Ni Mh
Phantom 10w Flashlight L10wFL 18V,1.4 Ah (6) CR 123 cells Non-Chargeable Li Mn
Phantom 10w HID 4 Ah 1700 FSW O-Ring PVC 4' long 7.5" L x 2.37" O.D. 3.9 lbs.
Phantom 10w HID 8 Ah 1000 FSW O-Ring PVC 4' long 15.0" L x 2.37" O.D. 5.3 lbs.
Phantom 10w Flashlight 1000 FSW N.A. Anodized Al N.A. 7.58" L x 2.45" max O.D. 1lb.6oz
4 Ah Auto-Cord Charger L209 100-240 VAC 24 VDC @ 1.00 A 4 hrs. Yes Float
4 Ah Car Charger L210 12V-28VDC 24 VDC @ 1.00 A 4 hrs. Yes TUV, GS, FC Float
8 Ah Manual Charger L 211-H 100-240VAC 18 VDC @ 1.11 A 10 hrs. No UL Manual
Phantom 10w HID Yes Ye s Ye s Yes Yes Yes
Phantom 10w Flashlight N. A. N.A. N.A. Yes N.A. N.A.
*Burn times are approximate and are dependent on temperature and depth of battery charge
**Ave. Life @ 1000 hrs. is defined by ANSI as follows: 50% of a sample of 100 bulbs will die at 1000 hrs.
*** Confirmed by actual pressure test
**** Charge Time is dependent on depth of discharge
Ocean Management Systems, Inc.
P.O. Box 146 Montgomery, NY 12549
.
Tel: 845.692.3600 Fax: 845.692.3623
www.omsdive.com
.
©2003 Ocean Management Systems, Inc.
Equipment for Underwater
ExplorationTM
LIMITED WARRANTY OMS PHANTOM DIVE LIGHTS
Exclusions:
Warranty Claim Procedure:
Tests conducted prior to shipment:
Specifications subject to change at any time
®
OMS , at its sole option, will repair or replace (with a new or a refurbished unit) any
Phantom dive light or dive light components deemed by OMS to be defective in
manufacture for a period of 1 year for the Original Retail Purchaser (Proof of Purchase
Required). The product must have been purchased from an authorized OMS retailer. If
you are unsure if the retailer is authorized, log on to www.omsdive.com or call OMS at
845-692-3600.
1. This warranty does not cover modification to the product, accidents, abuse, neglect or
misuse: This includes, but is not limited to: (a) Leaving the charger on in excess of the
recommended charge time and any damage resultant from exceeding the stated charge
time. (b) Charging the battery with a charger other than an OMS charger. (c) Failure to
properly maintain and lubricate all o-rings. (d) Leakage due to failure to properly close
caps, install lenses clips and o-rings and/or disassembly /assembly by other than an
OMS trained and certified technician. (e) Damage resultant from dropping the light. (f)
Transportation or shipping damage. (g) Fires and subsequent damage due to misuse of
product, including, but not limited to, transporting the light with the battery connected.
2. OMS batteries with labels are date coded and warranted for a period of 90 days after
date of purchase. Batteries with missing or illegible or altered labels are not warranted.
3.This warranty specifically excludes bulbs, o-rings, and lenses.
4. Rental or Commercial Use.
5.This warranty cannot be extended for any reason.
6. Claims made for damages in conjunction with a diving accident are excluded.
Call or Fax OMS with a description of the problem and
submit original proof of purchase. If the problem cannot be resolved over the phone
obtain an RMA number. Owner will be responsible for all freight costs. If the light is found
not to be covered by the OMS warranty an estimate of repair charges will be sent to you.
The repair cost may be more or less than the repair estimate.
1. Pressure test in a wet chamber to 328 FSW to verify water tightness.
2. Lighting test: Verifies that the bulb lights.
3. Battery Test: Verifies that the battery is charging properly and delivers proper V andA.
®
TM ®
®
®
®
®
®
®
®