OMS Phantom HID User manual

Professional
10 Watt HID
Dive Light OWNER'S MANUAL
HID Dive Light
OCEAN MANAGEMENT SYSTEMS, INC.
Item:
L197HM10-K
TM
Page 1
PhantomTM
HID Dive Light
The 10w HID light is designed for use underwater to an operational depth of 660 feet
seawater. To insure watertight reliability, each light is tested to a depth of 328 fsw. The 10w HID
light is a very compact, high output system with several unique features: A head mounted on-off
switch, unique shock mounted 10w HID bulb, a Lithium Ion battery and an international float
charger.
OMS®
Canister Mounting Hardware:
Stainless steel bands with quick links
ON/OFF Switch
With screw down lock on
back of light head
Optional
soft mount
Goodman
handle.
Front view
Back view
ON
OFF

Page 2
Before you start:
The new OMS HID light is shipped from the factory with a special Lithium Ion battery in a partially
charged state. The unit must be fully charged before its first use (see charge instructions below).
1. DO NOT UNSCREW TOP CAP (Cap with light cable). This has a 3-5 year seal life.
2. Unscrew bottom cap of battery canister (the cap without the light cord). Use 2 strap wrenches if
difficult to unscrew. Do not use metal tools as they will damage the cap and canister.
2. Disconnect the male and female Molex connectors.
3. You now have (2) ways to charge your battery:
a. Connect the adapter and charger together and then connect the
female Molex connector exiting the battery to the male Molex exiting the “charger”. Then plug in.
The Red and Green LED's will light during the charge. After the charge is complete (approx. 4 hrs.)
the red LED will go out and the green LED will remain on indicating the float mode.
b. With the Car adapter/Charger: Connect the Car adapter plug into the Charger. Connect the Male
Molex connector exiting the Charger to the female Molex connector exiting the battery. Charge for
for approximately 4 hours.
4. After charging, unclip the connectors by holding the plastic connectors and gently pull apart.
Reconnect
the light head Molex connector to the battery Molex connector in the battery canister.
5. Inspect Cap: Make sure that the threads and 'O' ring are clean and free of sand or dirt to prevent
damage or flooding. 'O' ring should have a thin film of 'O' ring grease.
6. Caution: Use extreme care when assembling or disassembling the bottom plastic battery canister
cap to prevent cross threading.
Reassembling Top or Bottom Battery Canister Caps: Caution: Lubricate threads of cap and inner
threads of PVC canister with Silicone grease before reassembly. Carefully place the inner part of the
cap into canister. Turn cap slightly counter clockwise until you hear the cap “seat”, then proceed to
turn cap clockwise until it is completely tight.
If necessary use “rubber friction gripper pads” to tighten caps (DO NOT USE TOOLS). Caution: If the
cap becomes very hard to turn during assembly STOP, back it off and carefully reassemble. If you
are unable to completely seat cap into canister, obtain an RMA from OMS and send the light for
repair.
Caution: During disassembly of the Light Cord CAP, the battery may cause the internal aluminum
retaining ring that holds the bottom of the battery to turn. If this ring is not properly adjusted to accept
the overall length of the battery, the battery will not fit and the top light cord cap will not fully close.
®
WARNING:
Caution:
With the Adapter/Charger:
Use only the OMS charger. Use of any other charger may
result in fire or explosion possibly resulting in serious personal injury or
property damage. Recharge the battery after every use, as deep discharge
will reduce life. Charger should be attached to battery before the plug is
inserted into AC socket
Under no circumstances pull the Molex connectors apart using
the electrical cords as you will damage the electrical connections.
®
®
.
Charging the batteries:
The hard coat anodized aluminum top cap is factory sealed and
should not be removed for a period of at least 3-5 years.
Page 3
Removing the battery:
Reinstalling the battery:
1.Before starting, secure light the head so it does not fall (place in pocket or place on
floor). 2. Unscrew the bottom battery canister cap. 3. Disconnect the battery Molex
connector from the light head Molex connector. 4.Unscrew the battery retaining ring. 5.
Slide battery out. : Unscrew
the bottom canister cap, then disconnect the light head and battery Molex connectors. If
your light is equipped with a switch lock, screw down the black locking screw while the
switch is in the OFF position. Reinstall the canister cap. Before diving, the switch lock
should be backed off so that it is flush with the bottom of the switch (area between the
bottom of switch and top of light body)
1. Before starting, secure light head so it does not fall (place in pocket or place on floor).
2. Unscrew the bottom battery canister cap. 3. Slide the wireless end of the battery into
the canister first (Molex connector should be opposite the cap with the light cord). 4.
Screw in the battery retaining ring. 5. Reconnect the battery and light cable Molex
connectors and place them in the recess of the bottom battery cap. 6. Lubricate and
replace the battery cap.
Make sure that you locate the canister bands below the threaded area of
the caps. Failure to correctly locate the bands away from the threaded area of the caps
may make the caps impossible to remove.
Disconnecting the battery and switch locking for travel
WARNING!
Replacing the HID bulb:
1. Disconnect the battery from the light head. 2. Remove all C-clips, O-Rings and front
lens (Fig. 1). 3. Remove bulb by pulling outwards. 4. Insert new bulb being careful to
match the bulb alignment key to the alignment slot in the socket (Fig. 2).
5. Reassemble. 6. Test for leaks in distilled water.
HID light housing
Bulb
“C” retainer ring
“O” ring
Glass lens
“O” ring
Front housing ring
Canister housing
Foam battery cushion
Battery retainer ring
“O” ring
End cap
Titanium
Hex screws

Note:
Caution:
We recommend that the bulb be replaced by an OMS trained technician or by OMS . If
neither option is open to you:
a. loosen the 4 Titanium screws very slowly
b. set O Rings aside in a clean area
c. remove old and install new bulb
d. reverse assemble lightly lubricating O-Rings
What to do in case of flooded light:
Turn off immediately. Immerse entire light in a 5 gallon pail of distilled or DI water. Hold
battery canister at the bottom of the pail of water and unscrew bottom cap (the cap without
the cord). This will allow any pressure build up to vent safely. Disassemble all parts and
place in distilled water, remove and dry thoroughly. Return to OMS by obtaining an RMA
number.
Procedure for service or making a warranty claim:
Contact OMS for a return authorization number and state reason (i.e. service, repair or
warranty issue). CALL 1-845-692-3600
Batteries: Standard 4.4 Ah Lithium Ion battery
Optional 8 Ah NiMH battery
Burn time: 4.5 hrs Approximate
Weight: 2.2 lbs
4 Ah Canister size: 7 5” length x 2.38 “Outside diameter
Burn time: 9 hrs. Approximate
Weight: 4.5 lbs
8 Ah Canister size: 15.0” length x 2.38” Outside diameter
Special Charger supplied
®®
®
®
4.4 Amp Hour battery
8 Amp Hour battery
Page 4
Can be used with either (a.) or (b.)
b
a
Page 5
WARNING and CAUTION
Use only underwater
DO NOT look directly into lamp - can cause severe eye damage.
Use only the OMS charger.
FIRST time the HID lamp is turned on - allow 5 minutes warm up time
before turning off.
To prevent damage to the lamp and optimize lifetime, do NOT turn lamp
on and off repeatedly.
If lamp is accidentally turned off, wait 15 seconds for it to cool (minimum 10
seconds) before restarting. This will help insure maximum lamp life. HID, like
other arc lamps, lose most of their life during the ignition-start-up.
Constant on-off-on-off use or shutdown prior to warm-up time (approximately 3
minutes) may damage the lamp.
Caution: Do not drop or bang light head. HID lamps are fragile and are very
susceptible to burnout or breakage due to shock.
When traveling or shipping, always disconnect the battery and engage switch lock
to prevent accidental activation of the light. Failure to disconnect the battery
during travel and/ or when the light is in close proximity to combustible materials
like dive gear, may result in fire damage. (see instructions *removing battery)
®
Mounting canister: Side of back plate (a.), bottom of back plate (b), belt mount (c), top of
valves (d.), nested between double tanks (e)

Page 6
HID Lights High Intensity Discharge Lights
(Single Canister battery system is standard for HID lights):
Battery Specifications:
Battery Canister Specifications:
Charger Specifications for HID lights:
Canister Mounting Options:
Light Type Item # Bulb Type Burn Time* Ave. bulb life** Output Focus Beam Angle Restart
Light Type Item # Capacity Cell Types Type
Light Type Type Depth Rating*** Connectors Material Cord Dimensions Weight
Type Item # Primaries Secondaries Charge time**** Float Charger Approval End of Charge
Light Type Backplate Waist Nesting between Cylinders Hand Held Manifold Area Butt mount
Phantom 10w HID Light L197HM10-K 10w HID 270 minutes/4Ah battery 1000 hrs. 450 Lm Fixed 6 degrees 5 sec.
Phantom 10w HID Light L197HM10-K8 10w HID 540 minutes/8Ah battery 1000 hrs. 450 Lm Fixed 6 degrees 5 sec.
Phantom HID Flashlight L10wFL 10w HID 120 minutes/1.5Ah batteries 1000 hrs. 450 Lm Fixed 6 degrees 5 sec.
Phantom 10w HID L197HM10 13.2V, 4Ah Battery Pack Rechargeable Li-Ion
Phantom 10w HID L197HM10-K8 13.2V, 8AH Battery Pack Rechargeable Ni Mh
Phantom 10w Flashlight L10wFL 18V,1.4 Ah (6) CR 123 cells Non-Chargeable Li Mn
Phantom 10w HID 4 Ah 1700 FSW O-Ring PVC 4' long 7.5" L x 2.37" O.D. 3.9 lbs.
Phantom 10w HID 8 Ah 1000 FSW O-Ring PVC 4' long 15.0" L x 2.37" O.D. 5.3 lbs.
Phantom 10w Flashlight 1000 FSW N.A. Anodized Al N.A. 7.58" L x 2.45" max O.D. 1lb.6oz
4 Ah Auto-Cord Charger L209 100-240 VAC 24 VDC @ 1.00 A 4 hrs. Yes Float
4 Ah Car Charger L210 12V-28VDC 24 VDC @ 1.00 A 4 hrs. Yes TUV, GS, FC Float
8 Ah Manual Charger L 211-H 100-240VAC 18 VDC @ 1.11 A 10 hrs. No UL Manual
Phantom 10w HID Yes Ye s Ye s Yes Yes Yes
Phantom 10w Flashlight N. A. N.A. N.A. Yes N.A. N.A.
*Burn times are approximate and are dependent on temperature and depth of battery charge
**Ave. Life @ 1000 hrs. is defined by ANSI as follows: 50% of a sample of 100 bulbs will die at 1000 hrs.
*** Confirmed by actual pressure test
**** Charge Time is dependent on depth of discharge
Ocean Management Systems, Inc.
P.O. Box 146 Montgomery, NY 12549
.
Tel: 845.692.3600 Fax: 845.692.3623
www.omsdive.com
.
©2003 Ocean Management Systems, Inc.
Equipment for Underwater
ExplorationTM
LIMITED WARRANTY OMS PHANTOM DIVE LIGHTS
Exclusions:
Warranty Claim Procedure:
Tests conducted prior to shipment:
Specifications subject to change at any time
®
OMS , at its sole option, will repair or replace (with a new or a refurbished unit) any
Phantom dive light or dive light components deemed by OMS to be defective in
manufacture for a period of 1 year for the Original Retail Purchaser (Proof of Purchase
Required). The product must have been purchased from an authorized OMS retailer. If
you are unsure if the retailer is authorized, log on to www.omsdive.com or call OMS at
845-692-3600.
1. This warranty does not cover modification to the product, accidents, abuse, neglect or
misuse: This includes, but is not limited to: (a) Leaving the charger on in excess of the
recommended charge time and any damage resultant from exceeding the stated charge
time. (b) Charging the battery with a charger other than an OMS charger. (c) Failure to
properly maintain and lubricate all o-rings. (d) Leakage due to failure to properly close
caps, install lenses clips and o-rings and/or disassembly /assembly by other than an
OMS trained and certified technician. (e) Damage resultant from dropping the light. (f)
Transportation or shipping damage. (g) Fires and subsequent damage due to misuse of
product, including, but not limited to, transporting the light with the battery connected.
2. OMS batteries with labels are date coded and warranted for a period of 90 days after
date of purchase. Batteries with missing or illegible or altered labels are not warranted.
3.This warranty specifically excludes bulbs, o-rings, and lenses.
4. Rental or Commercial Use.
5.This warranty cannot be extended for any reason.
6. Claims made for damages in conjunction with a diving accident are excluded.
Call or Fax OMS with a description of the problem and
submit original proof of purchase. If the problem cannot be resolved over the phone
obtain an RMA number. Owner will be responsible for all freight costs. If the light is found
not to be covered by the OMS warranty an estimate of repair charges will be sent to you.
The repair cost may be more or less than the repair estimate.
1. Pressure test in a wet chamber to 328 FSW to verify water tightness.
2. Lighting test: Verifies that the bulb lights.
3. Battery Test: Verifies that the battery is charging properly and delivers proper V andA.
®
TM ®
®
®
®
®
®
®
®
Table of contents
Popular Flashlight manuals by other brands

NEBO
NEBO Slyde Z 6267 user manual

Black & Decker
Black & Decker SL2 instruction manual

Milwaukee
Milwaukee 2160-20 Important safety instructions

Pfannenberg
Pfannenberg Quadro-A-DMX Operating and installation instruction

WUBEN
WUBEN P45R user manual