Install the sensor at 1.8 m (5'11") to 3.0 m (9'10").
EN 16005
OA-EDGE T
ENGLISH
44.3
(1 3/4")
X =Minimum 340 mm (13 3/8")
Main module
Profile
Front cover
Mounting clip
LED module
Spacer
Endcap
Power supply connector
Communication connector
LED indicator
Dipswitch A
Dipswitch B
Function switch
Angle adjustment screw
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(7) (8) (10) (11) (12)(8)
(7)
ON ON
Tx
Secondary module
(8) (11) (8)
(1)
(2)
(3)
(3)
(4)
(6)
(6)
(5)
(9)
(9)
Sensor module
(13)
(13)
ON
Tx
[mm(inch)]
50.7 (2")
Dimensions and part names
LED indicator LED module indicator
Safety/Test output 1
The color depends on
the state of the output.
Specifications
*1 : The sensor has to be connected to a door system is equipped with a SELV circuit.
The overcurrent protection of power supply cable has to be less than 2A.
*2 : According to EN ISO13849-1:2015
The specifications herein are subject to change without prior notice due to improvements.
NOTE
: Approx. 500 ms
: < 75 ms
: -20 to +55°C (-4 to 131°F)
: < 80 %
: < 70 dBA
: Opto coupler 10 to 30 VDC
Current 6 mA Max.
: Form C relay
Voltage 42 VDC
Current 0.3 A Max
(Resistance load)
Output : See Installation 3
: IP54
: 2 (EN ISO13849-1:2015)
: d (EN ISO13849-1:2015)
: Type 2
Output hold time
Response time
Operating temperature
Operating humidity
Noise level
Test input
Safety/Test output 1
Safety/Test output 2
IP rate
Category (*2)
Performance level (*2)
ESPE
Model
Profile color
Mounting height
Detection area
Detection method
Min. configuration
Max. configuration
Depth angle adjustment
Power supply (*1)
Power consumption
LED indicator
: OA-EDGE T
: Silver/Black
: 1.5 (4'11") to 3.0 m (9'10")
: See Detection area
: Triangulation
: 1 main module +1 LED module
: 4 sensor modules +2 LED modules
: 0° to +25°
: 12 to 24 VAC ±10 % (50/60 Hz)
12 to 30 VDC ±10 %
: < 1.3 W
(< 2 VA at AC) at Min. configuration
< 3.5 W
(< 4.5 VA at AC) at Max. configuration
: See LED indicator below
Green
Status
Stand-by
Opening side detection (output 1)
Closing side detection (output 2)
Incomplete Initialization
Learning
Incomplete learning
Signal saturation
Sensor failure
Sensor module indicator
Communication error
Red
Orange
Red & Green blinking
Yellow & Red blinking
Slow Red blinking
Fast Red blinking
Twice Orange blinking
Yellow blinking
Green
OFF
ON Red
Safety/Test output 2
Green
OFF
ON Orange
Manufacturer's statement
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows.
Failure to follow the instructions that accompany this indication and improper handling
may result in serious injury or death.
WARNING
Failure to follow the instructions that accompany this indication and improper handling
may result in injury and/or damage to property.
CAUTION
Pay special attention to sections with this symbol.
NOTE
1. This sensor is a non-contact switch intended for door mounting and to use on automatic swing doors.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment
connected to the sensor.
4. Only use the sensor as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country
in which the sensor is installed.
6. Before leaving the installation site make sure that the sensor is operating properly and instruct the
building owner/operator on proper operation of the door and the sensor.
7. The sensor settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
NOTE
Do not wash, disassemble,
rebuild or repair the sensor,
otherwise it may cause electric
shock or breakdown of the
equipment.
Danger of electric shock
WARNING
The following conditions are not suitable for sensor installation.
Fog,
Exhaust Wet Grating Objects Reflection
Original instructions
Setting to meet the requirements by EN 16005.
It is required to check the operation manual if this symbol is shown on the product.
EN 16005
Complied standards and extract from EC declaration of conformity
Notified Body 0044 : TÜV NORD CERT GmbH Am TÜV 1, 45307 Essen Germany
For technical document, see European Subsidiary
EN ISO 13849-2:2012
EN ISO 13849-1:2015EN 16005:2012/AC:2015 Chapter 4.6.8 and Annex C
EN 61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3
DIN 18650-1:2010 Chapter 5.7.4 ESPE
Machinery Directive 2006/42/EC EMC Directive 2014/30/EU
EN 61000-6-2:2005/AC:2005
EN 61000-6-3:2007 +A1:2011/AC:2012
EN 12978:2003 +A1:2009 A. Maekawa
General Manager
OPTEX CO., LTD.
Quality Control Dept.
Decrease the area depth angle, increase the non detection zone or move the sensor module
(see d2 in the chart) away from the leading edge to optimize the sensor performance.
For instaltion heigth <1900 mm the installation of an extra module will be mandatory in order to
comply with the regulations.
Test conditions according to EN 16005 Detection object : EN 16005 CA reference body
The actual detection area may become smaller
depending on the ambient light, the color/material
of the
object or the floor as well as the entry speed of the object.
Detection area at 2200 mm (7' 2 5/8") : Depth 140 (5 1/2") x Width 870 (2'10")
Emitting area at 2200 mm (7' 2 5/8") : Depth 140 (5 1/2") X Width 440 (1' 5 1/2")
Detection area
NOTE
NOTE
Recommended installation position
= Door width
= Mounting height
= Secured area width
= Distance from the leading edge
to the sensor module
= Distance between sensor modules
= Number of sensor modules
W
h
d1
d2
d3
n
Leading
edge
h
d2 d3
d1
W
EN 16005 CA reference body
h
W
1900
(6'3")
2000
(6'7")
2100
(6'11")
d2
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
2200
(7'3")
2300
(7'7")
2400
(7'10")
2500
(8'2")
3000
(9'10")
d1
760
(2'6")
790
(2'7")
825
(2'8")
870
(2'10")
895
(2'11")
920
(3')
950
(3'1")
1140
(3'8")
900 (2'12")
n
2
2
2
2
2
2
2
2
2
d3
175
(6 7/8")
160
(6 3/8")
145
(5 6/8")
120
(4 3/4")
115
(4 1/2")
110
(4 3/8")
100
(3 7/8")
30
(1 1/8")
1100 (3'7")
n
2
2
2
2
2
2
2
2
2
375
(14 3/4")
360
(14 2/8")
345
(13 5/8")
d3
320
(12 5/8")
315
(12 3/8")
310
(12 2/8")
300
(11 6/8")
230
(9")
1200 (3'11")
n
2
2
2
2
2
2
2
2
2
d3
475
(18 5/8")
460
(18 1/8")
445
(17 1/2")
420
(16 4/8")
415
(16 2/8")
410
(16 1/8")
400
(15 3/4")
330
(13")
[mm(inch)]
Each module has three communication connectors.
Use the most convenient connector for the
installation site.
Secondary module Secondary module
Secondary module
Door
controller
Door
LED
module
LED
module Main module *
* When more than 1 main module is installed on the door leaf, make sure that only one power supply
cable is connected to the operator otherwise initialization can not be completed.
All other main units will automatically function as a secondary unit.
Wire the cable to the door controller as shown below.
3. Wiring Power supply cable Communication cable
NOTE
Maximum of three sensor modules can be connected to one main module.
NOTE
a. Take the sensor modules out of the profile.
b. If the profile is longer than the door width, cut the profile. Make sure not to scratch the front cover.
c. Affix the profile on the intended mounting position leaving more than 20 mm (13/16") from door edge to attach the
endcap.
d. If necessary, drill two mounting holes of ø3.4 mm (ø1/8")and fix the profile.
e. When mounting a sensor on each side of the door, it is necessary to drill a wiring hole of ø12 mm to connect the sensor
modules. (See 3. Wiring)
Make sure there is some space between the mounting clips and the mounting screws.
Make sure not to scratch the profile when making a hole.
NOTE
Installation
1. Mounting the profile
Min. 20 mm
(13/16")
1
2
Silver screw
Black screw
(small)
Make sure to fix the sensor modules firmly by the mounting clips.
NOTE
The lens that is marked "Tx" must be positioned onto the corresponding door edge.
Refer to Detection area for the sensor module position. The sensor module can be inserted in reverse as shown below.
To do this,detach the mounting clip and rotate the sensor module by 180° and reattach the mounting clips.
2. Inserting the sensor module
ON ON
Tx
ON ON
Tx
1
2
3

Outside of
detection area
COM.
N.C.
N.O.
COM.
N.C.
N.O.
Entry into opening
side detection area Entry into closing side
detection area
Entry Power OFF
Status - Detection active Detection activeStand-by
LED indicator None Red OrangeGreen
Safety/Test output 1
(Stop impulse)
Safety/Test output 2
(Reverse impulse)
COM.
N.C.
N.O.
COM.
N.C.
N.O.
COM.
N.C.
N.O.
COM.
N.C.
N.O.
NOTE
Check the operation according to the chart below.
Checking
The door movement might become unstable right after the learning. The movement becomes stabilized
after several openings and closings. Always walk-test the detection area to ensure the proper operation.
1. Always keep the front cover clean. If dirty, wipe it with a damp cloth. Do not use any cleaner/solvent.
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. When LED indicator blinks fast Red without any object in the detection area, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the front cover.
Inform building owner/operator of the following items
WARNING
1. After applying power, wait 10 s then walk test detection area to ensure proper operation.
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)
NOTE
Problem
Troubleshooting
Possible cause Possible countermeasures
The sensor has no function.
Incomplete initialization.
(Red & Green blinking)
Initialization is not finished.
(Red & Green blinking continuous)
Incomplete learning.
(Yellow & Red blinking) Initialization has not been conducted. Push the function switch for less than 2 s for
learning.
Learning does not start.
(Twice Orange blinking)
Check the communication wires or change
wires.
Communication error.
Sensor operates by itself.
(Ghosting)
Or learning is not finished.
(Yellow & Red blinking continuous)
Same frequency setting on double
swing door application. Set the different frequencies. (Dipswitch A2)
Objects that move or emit light in the
detection area. (Ex.Plant, illumination, etc.) Remove the objects.
The floor pattern is not plain or‚ the
door movement is irregular.
Set the immunity (Dipswitch A3) to "ON".
Extend the non detection zone.
The modules are affecting each other. Change the module positions or adjust angles
or adjust the area width. (Dipswitch B2)
Signal saturation.
Sensor operates by itself.
(Ghosting) Waterdrops on the front cover. Install in a place keeping the waterdrops off.
The module angle is changed. Check the module angles.
The sensor functions without the
front cover but not with it. The front cover is dirty. Wipe the front cover with a damp cloth.
(Do not use any cleaner or solvent.)
The front cover is scratched. Replace the front cover.
Sensor operation is not linked to
door movement.
Connection error or wrong mounting
side setting.
Check the wiring or mounting side setting.
(Dipswitch B4)
Door remains open or closed
without any object in the detection
area.
Presence timer set to infinity and
sudden change in the detection area.
Push the function switch for less than 2 s for
learning. Or change presence timer setting.
(Dipswitch A4)
Signal saturation.
(Slow Red blinking)
The front cover on inner or outer side is
dirty.
Wipe the front cover with a damp cloth.
(Do not use any cleaner or solvent.)
Check the communication wires.
Communication error.
(Twice Orange blinking)
The sensor is affected by the floor color. Push the function switch for less than 2 s for
learning. Or extend the non detection zone.
Sensor failure.
(Fast Red blinking) Contact your installer or service engineer.
Change the module positions or adjust angles
or adjust the area width. (Dipswitch B2)
Wrong power supply voltage.
Wrong wiring or connection failure
Initialization has not been conducted.
Dipswitch setting is changed.
More than 2 main modules are
connected with power supply wire.
Set to the stated voltage.
Check the wiring and connectors.
Push the function switch for more than 2 s for
initialization.
Connect the power supply cable to only one
main module.
Connect the communication cable of the LED module to the main or secondary module. Attach the spacer on the endcap
side. Insert the LED module to the profile as shown below. The LED module can be inserted to both side of the profile.
When a test input is not required, set the dipswitch A7 to OFF.
NOTE
To the power supply
connector of
the main module
}
Power supply
12 to 24 VAC ±10 % , 12 to 30 VDC ±10 %
Safety/Test output 2
Form C relay
Reverse impulse (Closing side)
}
Test input
Opto coupler Voltage : 10 to 30 VDC
}
}
Safety/Test output 1
Form C relay
Stop impulse (Opening side)
9.Black
10.Violet
1.White
2.Brown
3.Green
4.Yellow
5.Grey
6.Pink
7.Blue
8.Red
(+)
(-)
(+)
(-)
COM.
N.C.
N.O.
COM.
N.C.
N.O.
Before starting the procedure, make sure that the power is turned OFF. When passing the cable through the hole,
do not tear the shield otherwise it may cause electric shock or breakdown of the sensor.
Danger of electric shock
WARNING
4. Inserting LED module
To Main/Secondary
module NOTE
For LED status see
Specification.
5. Placing the front cover
After Adjustments are completed, place the front cover and endcaps.
Only correctly initialising the sensor
ensures the correct functioning of the
dipswitches. (See 5. Function switch)
The value is a reference for
a mounting height of 1.8 to 3.0 m
(5'11" to 9'10").
Each main module is equipped with dipswitch A and dipswitch B and each secondary module is equipped with only
dipswitch B. Only dipswitch A of the main module connected to the door controler is applicable and will reflect the
settings to all connected main and secondary units automatically.
The non detection zone is the height measured from the floor up to the position where the sensor starts to detect.
The zone can be set by a combination with dipswitch A1 & B1.
Non
detection
zone
Side view
Dipswitch A
ON
A1
A4
A5
A6
A7
A8
Non detection zone (A)
Frequency
Immunity
Test input
Test input delay
For future use
A3
A2
Presence timer
2. Setting the non detection zone
3. Other setting for Dipswitch A
Adjustments
1. Dipswitch settings
Dipswitch B
ON
B1 Non detection zone (B)
B2
B3
B4 Mounting side
(output select)
Area width
Self monitoring mode
NOTE
Factory default settings
Factory default settings
[Non detection zone value] = [Dipswitch A1 value] + [Dipswitch B1 value]
NOTE
CommentSettingFunctionNo.
* The test input delay time is the time period between the test input
and safety/test output.
When installing the sensors on a double swing door make sure that
the frequency on each sensor is set differently.
Setting1
A2 Frequency
A2
Setting2
A2
Set dipswitch A3 to ON when the sensor operates by itself (ghosting).
When dipswitch A3 is set to ON, the actual detection area may
become smaller than set to OFF.
OFF
A3 Immunity
A3
ON
A3
Test input
(from door controller)
Safety/Test output
(to door controller)
Test input
Detection
OFF
(High)
ON
(Low)
N.O.
N.C.
t1(>t2)
t2 t2
Open
Close
Open
Close
Test input and safety/test output timing chart
Set dipswitches A7 and A8 according to the instructions from the
door controller.
A7 Test input
OFF
(High)
ON
(Low)
A7 A7
A8
Test input
delay time *
(=t2)
10 ms 20 ms
A8 A8
A7
The presence timer can be set by dipswitch A4.
If an object remains in the detection area longer than the setting,
LED indicator may blink fast Red. In this case, it is not sensor failure.
After an object is removed, LED indicator will show Green.
A4 Presence timer
60 s
A4 A4
∞
OFF
ON
OFF
ON
Total non
detection zone
35 cm (13 3/4")
25 cm (9 13/16")
45 cm (17 11/16")
15 cm (5 7/8")
Dipswitch A1
15 cm (5 7/8")
15 cm (5 7/8")
+35 cm (13 3/4")
+35 cm (13 3/4")
ON
Dipswitch B1
0
+10 cm (3 15/16")
0
+10 cm (3 15/16")
OFF
6. Area depth angle adjustment
The angle of each sensor module must be adjusted so that the door stops before it
comes into contact with an obstacle. After area angle adjustments, start the learning
as described in 5. Function switch.
When the sensor module on the leading edge is installed ≥ 2000 mm, d2 is set to 70 mm
and the non-detection zone is set to 15 cm, make sure that the area angle adjustment is
≤ 10°. If a deeper detection field is required you can increase the non-detection zone
for extra coverage or increase d2 slightly.
Angle adjustment screw
Adjustable angle : 0° to +25°
Initialization & Learning
Initialization :
Action
Initialization
Push the function switch for more than 2 s.
Learning
Push the function switch for less than 2 s.
5. Function switch
Only the main module is equipped with a function switch. The function switch of the main module that is connected to
the door controller is only applicable to reflect settings to all sensor modules connected.
NOTE
Do not enter the detection area when the sensor is performing a learning cycle.
NOTE
Make sure to use the function switch when the door is in the fully closed position.
Initialization is necessary when power is supplied for the first time or when there is a change in dipswitch
settings. Push the function switch for > 2 s to initialize the complete sensor configuration.
After an initialization or a change in the settings always make a learning cycle by pushing the function
switch < 2 s.
Learning :
After the adjustment, check the detection area.
EN 16005
4. Other setting for Dipswitch B Factory default settings
CommentSettingFunctionNo.
Set dipswitch B2 to "2 spots" when
a narrow detection area is required.
B2 Area width
4 spots 2 spots
B2 B2
4 spots 2 spots
B3 Self monitoring
mode
ON
B3
OFF
B3
Opening side
(Output 1)
Output
Safety/Test output 1
(Stop impulse)
Red
(Detection)
Closing side
(Output 2)
Safety/Test output 2
(Reverse impulse)
Orange
(Detection)
LED indicator
B4 Mounting side
(Output select)
Opening
side
(Output 1)
B4
Closing
side
(Output 2)
B4
By selecting the sensor position the outputs & LED indicator will
function as shown below :
Set dipswitch B3 to "ON".
When dipswitch B3 is set to "OFF", it excludes conformity of the
door system according to EN 16005.
EN 16005
OFF ON
OFF ON
Yellow and Red blinking
Red & Green blinking
LED indicator
Turn off and then, start to blink Green to indicate
the number of connected sensor modules
Yellow blinking
Green
First power supply Dipswitch setting change
Legal representative (UK only)
OPTEX (EUROPE) LTD.
Unit 13 Cordwallis Park Clivemont Road
SL6 7BU Maidenhead, Berkshire United Kingdom
Tel : +44 (0)1628 631 000
www.optex-europe.com
Manufacturer
5-8-12 Ogoto Otsu 520-0101, Japan
www.optex.net
OPTEX CO., LTD.
EMEA Subsidiary
OPTEX Technologies B.V.
Henricuskade 17, 2497 NB The Hague,
The Netherlands
Tel : +31(0)70 419 41 00
www.optex-europe.com
This manual suits for next models
18
Other Optex Garage Door Opener manuals
Popular Garage Door Opener manuals by other brands

GRITAL
GRITAL GR30 manual

Merlin
Merlin MT600 Installation and operating instructions

Schartec
Schartec Move 3 Series Installation and operating instructions

Linear
Linear LD 033 Homeowner's instructions

Chamberlain
Chamberlain B980C owner's manual

Novoferm
Novoferm Novomatic 403 Installation, operating and maintenance instructions

Craftsman
Craftsman 139.53669SRT owner's manual

Chamberlain
Chamberlain LiftMaster 355LM Security+ owner's manual

Craftsman
Craftsman 139.53776 owner's manual

Forematic
Forematic F350 installation manual

GFA
GFA KE 40.24-40,00 Ex installation instructions

Wayne-Dalton
Wayne-Dalton Torquemaster Plus 8000 quick start guide