Optex IVP-GU iVISION+ User manual

IVP-GU features
SENSOR ALERT Function with OPTEX WIRELESS2000: TC-10U & TD-20U*1
“OPEN DOOR” Relay Output Function *2
AC/DC (10~24V) Adaptable
Chime On-Off Mode
*1 SENSOR ALERT Function substitutes a push on IVP-DU with a sensor detection.
OPTEX WIRELESS2000 TC-10U and/or TD-20U must be configured to work with iVISION+ system in a stable environment
*2 Relay Output function must meet other requirements dependent on the third party equipment.
OPTEX will not be held responsible for any damage or injuries caused due to using this function.
IVP-GU
(Gateway Chime Unit)
Installation Instructions
Wireless Video Intercom
IMPORTANT NOTICE
1.
Operations under harsh environments such as out of warranted temperature,
rapid temperature change, high humidity, constant moisturization may cause the
unit to malfunction.
Electronic device such as TVs, Radios, PCs, Microwave ovens or any other device
with an electric motor may cause the unit to malfunction.
Impact or shocks can cause severe damage to the unit. Please handle the unit
with care and operate without exerting strong forces.
Transmission range of communication between units may decrease under
the following conditions.
- Any unit is installed on a metal surface.
- Presence of reinforced concrete, steel doors or other metal construction
materials between units.
- Places near strong radio sources such as broadcast stations or substations.
While installing/using a Gateway Chime Unit
- Do not install/use in damp, steamy or dusty environments.
- Do not hold the Gateway Chime Unit to your ear - your hearing could be damaged.
- Do not install in an unstable location or where subject to strong vibration.
PARTS IDENTIFICATION
3.
CHOOSING LOCATION
2.
If there is a pre-existing door bell inside the house, a Gateway Chime Unit (IVP-GU)
may be capable of adapting the pre-existing power wires (AC/DC 10-24V 3 Wmax).
IVP-GU bridges a communication between OPTEX WIRELESS2000 system and
iVISION+ system. IVP-GU should be located in a place where the unit has a
clear signal reception and transmission availability.
The performance of a IVP-GU is dependent on the transmission environment of radio
signals from locations of connecting units. A communication range will be significantly
reduced by more number and thickness of walls which the signal is required to pass.
For iVISION+ system, maximum communication range is around 300ft (100m)
in an open air environment. Following materials may decrease the maximum
communication range and may potentially cause loss of transmission signals.
• Metal barricades such as metal doors and shutters.
• Walls with aluminium foil insulation.
• Concrete or galvanized metal walls.
Gateway Chime Unit uses 2.4GHz radio frequency for iVISION+ system and 418 MHz
radio frequency for expansion to OPTEX WIRELESS2000 devices.
The Gateway Chime Unit needs to be powered from an AC/DC 10-24V 3W(max)
power source. An open ended third party power adapter may be available from
local electronics stores. Power input has no polarity. Please make sure to tighten
terminal screws to avoid loose ends.
If applicable, configure all pairing setup and carry out feasibility study before
mounting on a wall.
6.
Speaker
LED Indicator
Gateway Chime Unit (Front)
POWERING THE UNIT
4.
ATTENTION:
Thank you for purchasing the iVISION+ wireless video intercom.
Before installation and usage, please read this instruction manual thoroughly
and keep this safe for future reference.
Mounting Screw
Gateway Chime Unit (Back)
Power input
Relay output
Pairing button A& B
Chime ON/OFF switch
Fixing Screw
Mounting Plate
INSTALLATION
5.
For the optimal radio performance, mount IVP-GUs high on a wall and in an open area avoiding a metal surface and surrounding.
(1) Fix a Mounting Plate on a feasible location (2) Run a power cable to the location
and connect to the Power input.
If applicable, also run a relay connection
from the Relay output to the third
party equipment.
(3) Slide the IVP-GU onto
the Mounting Plate and
tighten the Fixing Screw
at the bottom.
One iVISION+ system can host up to 2 units of Gateway Chime Unit (IVP-GU).
N.C.
COM
N.O.
AC/DC
10-24V
Relayoutput
Powerinput
Mounting Screw
toPowerinput
toRelayoutput
21mm/0.83”
Tightenascrew
Slideon
toapowersource
toathirdparty
equipment
If “OPEN DOOR” Relay Output function is used, please carefully choose a location for each of IVP-GU to secure a physicalaccess to the IVP-GU.
Mounting Plate
(optional)
Note: if it is a just out of box, IVP-GU is in the paring mode when powered on.
NOTE: An additional Device DU, HU and GU must be paired to HU as follows:
1
IVP-DU IVP-HU IVP-GU
Exsiting
iVISION+
System
1
How to add IVP-GU to HU 1
(1) Press pairing button twice in the back of IVP-HU .
The unit will be in “PAIRING MODE”.
(2) Proceed to “SCAN” by pressing “Left function key”. IVP-HU starts scanning
for other devices for 60 seconds.
(3) Press both A and B buttons while powering up the GU to enter the paring mode.
Once IVP-GU is paired, HU shows “GW CONNECTED”.
1
1
1
PAIRING WITH IVP-HU 1

WARRANTY
10.
SPECIFICATION
9.
PAIRING WITH OPTEX WIRELESS2000 SYSTEM
7.
MODEL NAME: OPTEX iVISION+ (IVP-GU) Gateway Chime Unit
Operating Temperature
9-1 Dimensions
9-2
Specification Table
ADDITIONAL SETTING
8.
TD-20U
(STEP 3) Send pairing signal to IVP-GU
(4) Press IVP-DU push button once and hold paring button located at the bottom
of battery compartment until it makes a keeping sound.
Gateway Chime Unit (IVP-GU) can be paired with OPTEX TC-10U & TD-20U devices.
7-1 Pairing TC-10U & TD-20U to Gateway Chime Unit
To change a chime volume of IVP-GU
– Press button A to acknowledge current chime volume level. Press A button again to
change volume level to the next. The volume changes within 4 levels and the lowest
volume will follow the loudest. Leave the setting at the desirable volume level.
To completely turn off the chime, set Sound ON/OFF Switch to OFF.
When paired with TC-10U or TD-20U, following features are available;
- If corresponding Door Camera Unit (IVP-DU) is connected to an external
power source, TC-10U or TD-20U can trigger an image capture from the IVP-DU.
- IVP-GU can act as an extra chime unit in WIRELESS2000 system.
IVP-GU
NOTE: Please configure IVP-GU before pairng WIRELESS2000 device.
To connect iVISION+ system to OPTEX WIRELESS2000 devices (e.g. TC-10U)
HOME ID must be assigned to IVP-GU prior to pairing.
110mm / 4.33”
80mm / 3.15”
Dust/Water Protection
Radiowave Frequency
0 to 40 degC (32 to 104 degF)
< 90% RH (no condensation)
N/A (Indoor Use Only)
2.4 GHz and 418MHz
Operating Humidity
Power AC/DC 10-24V 3W(max)
One IVP-GU can host 2 units of TC-10U or/and TD-20U, each into zone 1 and 2.
Both zone 1 and zone 2 will be associated to a Door Camera Unit (IVP-DU) which is
corresponding to the IVP-GU. In total, one iVISION+ system can host
4 WIRELESS2000 devices through 2 IVP-GUs.
5921751
REV1.01
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com/
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec/
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
URL: http://www.optexeurope.com/
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net/
TC-10U
(STEP 4) Confirm operation of WIRELESS2000 devices
TD-20U
TC-10U
After inserting a
battery, remove
magnet part of
the device away
from the TC-10U.
After inserting a
battery, wave your
hand across front
of the TD-20U
NOTE: How to trigger WIRELESS2000 devices
(STEP 2) Prepare IVP-GU into a pairing mode
Enter into a pairing mode by holding down B button.
LED starts blinking. Select a zone by pressing B button.
The pairing mode continues for 30 seconds.
While the IVP-GU is in a pairing mode for a designated zone, trigger TC-10U or
TD-20U to send a radio signal. IVP-GU will register the signal with a chime.
Exit the pairing mode by holding down B button.
LED stops blinking when in a normal operation mode.
Trigger the paired WIRELESS2000 device. IVP-GU will blink LED and ring a chime
(Sound ON/OFF Switch must be ON). IVP-HU will also respond by a chime sound
unless a volume on IVP-HU is set to null. IVP-HU will also capture an image from
a corresponding IVP-DU if the IVP-DU is connected to an external power source.
SENSOR ALERT mode Enable/Disable setting
– By disabling SENSOR ALERT mode, iVISION+ system become ignorant of connected
WIRELESS2000 devices. This setting is changed by holding “Right Function Key” on
a Handheld Monitor Unit(IVP-HU). The LED on IVP-GU indicates the current setting.
When in RED, SENSOR ALERT is Enabled.
When in GREEN, SENSOR ALERT is Disabled
30.3mm / 1.2”
NOTE: Low battery notification of WIRELESS2000 devices
If a zone of IVP-GU already has an assigned WIRELESS2000 device, the zone will
not be overwritten and register another WIRELESS2000 device.
When pairing is denied, rapid beeps will sound.
(STEP 1) Clear/initialize IVP-GU for a new pairing of WIRELESS2000 devices
Enter into a pairing mode by holding down B button. LED starts blinking.
Select a zone by pressing B button. Hold down A button until two short beeps sound.
Repeat the same process for another zone if necessary. Exit the paring mode by
holding down B button or proceed to STEP3 if pairing immediately.
Zone 1, LED blinks slowly at 1 Hz (Green/Red)
Zone 2, LED blinks fast at 2 Hz (Green/Red) When any paired WIRELESS2000 has a low battery condition,
IVP-GU will make a short beep following a chime sound.
Low battery beep does not sound if the sound switch on IVP-GU is set to OFF.
1. This product is under a warranty for a normal usage for 18 months from the date
of manufacturing. The date of manufacturing can be identified from a LOT number
indicated on a label placed in a back of IVP-GU.
2. The warranty may not be applicable when any of following circumstances is found.
- Mechanical or electrical modification is made to the product and the good’s
appearance indicates an alterations or a significant damage.
- The product is already been diagnosed by someone other than the manufacturer.
- Product malfunction is resulting from an improper usage, an accident,
natural disaster or any environmental event.
- Please call our technical assistance before arranging a return.
LOT: YYWWZ (e.g. LOT 1350Z)
YY indicates last two digits of the year manufactured (e.g. “13” = Year 2013)
WW indicates Xth week of the year manufactured (e.g. “50” = 50th week)
Pairing button A& B
LED (RED/GREEN)
Relay Output 1C 50VAC/24VDC 1A max
* HOME ID is an unique identification number for your iVISION+ system.
Pairing button
Sound ON/OFF Switch
The Gateway Chime Unit operates regardless of
the switch setting while power is being supplied.
This switch is for turning
ON/OFF a speaker.
Pairing button A& B
Top view
Unit (IVP-HU)
Table of contents
Other Optex Intercom System manuals

Optex
Optex iVision+ User manual

Optex
Optex IVPC-DS User manual

Optex
Optex iVision+ User manual

Optex
Optex iVision+ User manual

Optex
Optex IVPC-DI User manual

Optex
Optex iVISION+ IVP-DU User manual

Optex
Optex iVision+ IVP-HU Operation and maintenance manual

Optex
Optex iVision Plus IVP-DU User manual

Optex
Optex IVP-DU User manual

Optex
Optex iVISION+ IVP-GU User manual