PRINTER INSTALLATION HOW TO GUIDE
OP-412T OP-412T-L1 OP-412T-L2
OP-900 / OP-901 Indicator Parameter Settings
To enter calibration/parameter settings, follow the procedure below:
1. Make sure the unit is set to either kg or lb
2. Press and hold the HOLD and PRINT key at the same time for 2 seconds
3. Navigate through the settings (C01 to C18) as shown in the table below by using the arrow keys and return keys as labeled under
each indicator button
4. Press the PRINT key to enter/edit the parameter setting
5. Press the ACCUM key to save and exit settings at any time
Function Parameter Settings/Options
Communication
Setting C18
Set the serial interface data output method:
0 = Turn off serial interface data output
1 = Continuous sending mode, for remote display
2 = Print to paper thermal ticket printer (OP-412T)
3 = Command request mode, for computer.
4 = PC continuous sending mode, for computer
5 = PC/remote display, continuous sending mode
6 = Print to small label thermal printer (OP-412T-L1)
7 = Print to Zebra/large label thermal printer (OP-412T-L2)
8 = Reserved
Baud Rate C19
0 = 1200 (for OP-910 remote display)
1 = 2400
2 = 4800
3 = 9600 (for all Printers and OP-910X, OP-910XL)
4 = 14400
OPTIMA SCALE MANUFACTURING INC.
sales@optimascales.com www.optimascales.com
1005 Union Center Dr. Ste b
Alpharetta, GA 30004
OP-902 Parameter Settings
●Press HOLD and UNIT together to enter the
parameter settings
●Use the following diagram to navigate through
the parameter settings:
Function Display Parameter Settings
Communication
Setting trn 1 Set the serial interface data output method:
0 = Turn off serial interface data output
1 = Continuous sending mode, connect computer
2 = Print mode, connect printer (OP-412T)
3 = Command request mode, connect computer
Baud Rate bAud 1 1 = 9600bit/s (OP-412T)
2 = 4800bit/s
3 = 2400bit/s
4 = 1200bit/s
5 = 600bit/s
Key Function
ON/OFF Exit
HOLD Conrm
ZERO Move Left
UNITS Move Down

Other manuals for OP-900 SERIES

1

This manual suits for next models

4

Popular Printer manuals by other brands

Panduit COUGAR LS9Q Operator's manual

Panduit

Panduit COUGAR LS9Q Operator's manual

Centronics 101A Technical manual

Centronics

Centronics 101A Technical manual

Epson Expression Photo XP-750 Basic guide

Epson

Epson Expression Photo XP-750 Basic guide

FutureLogic GEN2 Guide

FutureLogic

FutureLogic GEN2 Guide

Canon Q30-3201-US1 user guide

Canon

Canon Q30-3201-US1 user guide

Jolimark bp-900kll user manual

Jolimark

Jolimark bp-900kll user manual

Ricoh SP 8400DN manual

Ricoh

Ricoh SP 8400DN manual

Datamax-ONeil RL3 user guide

Datamax-ONeil

Datamax-ONeil RL3 user guide

Printekmobile I-820 Operator's manual

Printekmobile

Printekmobile I-820 Operator's manual

Samsung CLP-315 - CLP 315 Color Laser Printer manual

Samsung

Samsung CLP-315 - CLP 315 Color Laser Printer manual

Aficio SP 1200S Quick installation guide

Aficio

Aficio SP 1200S Quick installation guide

Epson TM-L90 series Start here

Epson

Epson TM-L90 series Start here

IBM 102 user guide

IBM

IBM 102 user guide

Microcom 428LT Operator's manual

Microcom

Microcom 428LT Operator's manual

Canon BJC-4000 Service manual

Canon

Canon BJC-4000 Service manual

Brother P-touch MW-145BT user guide

Brother

Brother P-touch MW-145BT user guide

Samsung CLP-36x Series user guide

Samsung

Samsung CLP-36x Series user guide

Rimage Desktop 360i Replacement guide

Rimage

Rimage Desktop 360i Replacement guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.