Opus OP-6505B User manual

Digital Window Intercom
User Guide
2020
OP-6505/B
1

2

Summary…………………………………………………………………………………………….……. 3
Safety precautions………………………………………………………………………………………… 4
Product introduction……………………………………………………………………………………. 5
Features………………………………………………………………………………………………….…… 5
Hardware interface instruction……………………………………………………………….…… 6
Packing list……………………………………………………………………………………….………….. 7
Wiring………………………………………………………………….………………………….…….…….. 8
Basic function……………………………………………………………………………………….……… 9
Local intercom……………………………………………………………………………….………….…. 9
Remote intercom………………………………………………………………………….……………… 9
Scene mode adjustment…………………………………………………………….…………………
Engineer settings…………..………………………………………………………………………………
9
9
Recording…………………………………………………..………………………………….…………….. 10
Fault exclude………………………………………………………………………………………………… 10
Connect OP-6505B……………………………………………………..…………………………… 11
Connection diagram ………………………………………………………………………………….. 14
Contents
3

Summary
Warning and Reminding
This symbol means there are potential safe troubles, it may cause death or
serious injury with incorrect operation.
This symbol used to remind the user that this device attached the important
operation and maintenance instructions.
Setting and Installation
•Avoid wet by water.
Do not put the machine to be exposed to rain water or other liquid stained environment,
otherwise it may lead to fire or get an electric shock.
•Do not use the other power voltage.
Using the device marked voltage to connect it.
It may lead to fire or electric shock if using the higher voltage.
•Do not scratch the power cord.
Don’t scratch, cut or twist the power cord.
Please keep the power line far away from the heated object and do not put heavy things on it,
otherwise it may lead to fires or electric shock.
Using machine
•In case of the anomalies appears.
Please shut off the power supply immediately when finding the following abnormal phenomena
within using, please contact with supplier. It may cause fires or electric shock if it`s still using it.
When the device with smoking or strange flavor.
The device internal is invaded by water or other things. Device fall off or device shell is damaged.
The power cord is damaged (wire core is exposed or broken etc). Device fault (it can`t connect
network, no sound etc.).
•Do not open the device internal or modify the device Don`t make other things
invaded to the device internal.
Don’t make the metal items or inflammable objects inserting to device internal, otherwise it will
cause fires or electric shock.
•Do not touch when lightning
To avoid electric shock, please do not touch the device and the plug while lightning.
•Do not put the liquid container or metal object on the device
If the container is fall down and make the liquid permeate into the device, it will cause fire or
electric shock.
•Do not open the device internal or modify the device
The device internal contains high voltage parts, once open the cover or modify the device, it may
cause fires or cause shock.
All about device maintenance and modification should be operated by professional personnel.
•The notice for maintenance or long time without using
Please shut down the power and pull out the power line while maintenance or the device won`t
be used for 10 days or more.
It may cause electric shock or fires if do not make it.
4

Internal window intercom Internal window intercom
Features
•Adopt single DSP multi-channel language auto-control technology, avoiding squeaking and
disturb to realize real digital full-duplex intercom.
•Adopt full touchable transparent key design, keep intercom without disturb from key-click
and keep it with the halo light on.
•Recognizing sound source, control environment noise, automatically adjust volume and
restore the original sound.
•Providing three mode scene (quiet, standard, noisy), support one-key adjustment.
•Wiring external and internal intercom adopt one line to connect the desk, better solving
the loosen caused by moving and keeping the desk more clear and beautiful.
•Professional cavity structure design, adopting hard metal cavity to prevent machine
resonance, purify and naturalize the sound to transparent.
•Personalized and customized service language, manual broadcasting “Hello, welcome”,
“Thank you welcome for next time coming”
•Support double recording mode and providing the recording output to HD recording host
and DVR to process the third-party recording storage.
•LED distinguished show the real state of internal window intercom.
Coordinate HD recording host function:
•Realizing remote calling and receive calling, hands-free intercom with central microphone.
•Remote central microphone can real-time monitoring window intercoms.
•Receiving remote one-way network broadcasting.
•Internal window intercom can make real-time recording by the record key and it will be
stored on the HD recording host.
•Remote upgrading the firmware of window intercom in the HD recording host web page.
5

Hardware interface instruction
Internal window intercom
【Front view】
①Working indication light: red light is offline, green light is online
②Loudspeaker: amplify the local intercom audio.
③Recording key: make a recording when press the key at the first time, finish the recording
by press again, the recording key will quickly red flashed in the recording process.
④Intercom key: press the key to intercom with external window intercom, finish the
intercom by press again, the green intercom key will be light on.
⑤Microphone pole socket: plug the microphone pole, collecting local intercom audio.
⑥Voice broadcasting key remote intercom key:
Voice broadcasting: Press voice broadcast key to automatic play voice prompt in the process
of intercom with window external terminal, press shortly to prompt "Hello, welcome", long
press for a while to prompt "Thank you, welcome to come next time.". The broadcasting key
green flashed during the process of broadcasting.
Remote intercom: coordinate with HD recording host to use, click this key to call named
terminal by server in the online condition.
【Side view】
①Scene mode regulating switch:3 scene mode adjustment 【noisy(1)、standard(2)
、quiet(3)】, defaulted as standard mode.
【connection wiring】6

①Power interface: connect with DC12/2A power.
②Communication interface:connect with the network HD recording host.
③Analog audio input interface: output analog audio, connect with DVR or camera.
④External window intercom interface.
【External window intercom】
①Loudspeaker/MIC:
Loudspeaker:amplify the local intercom audio;MIC:pick up the local intercom audio;
②Internal window intercom interface
Packing list
Window intercom system include following accessories, please check following parts, please
contact with distributor if any parts are missing.
(1)Internal window intercom 1 set
(2)External window intercom 1 set
7

(1)Microphone pole 1 pcs
(2)Power adapter 1 pcs
(3)Wiring harness (3*100mm)3 pcs
(4)Cable clamp (HC-100) 3 pcs
(5)Wiring connector (3.81-2P) 1 pcs
(6)Quick installation manual 1 pcs
Wiring
(1)Connect the one port of power adapter to the power interface of internal
window intercom, the other port connect with power socket.
(2)Connect interface of external window intercom with internal window
intercom.
(3)Connect the one port of Ethernet to internal window communication
interface and the other port connect to HD recording host (only suitable for online
environment).
8

Basic function
Local intercom
After connected internal window intercom and external window intercom, then power-on.
Press the intercom key of internal window intercom, it can digital full duplex HD intercom with
external window intercom, press again to stop intercom.
Remote intercom
Used with HD recording host, under the online status, press remote intercom key to call the
server pointed terminal.
Scene mode adjustment
Window intercom provides three scene modes: Noisy (1), Standard (2), Quiet (3) 】; the
default mode is standard mode.
Incoming prompt tone:
Press voice broadcast key to automatic play voice prompt in the process of intercom with
window external terminal, press shortly to prompt "Hello, welcome", long press for a while to
prompt "Thank you, welcome to come next time.". To finish the audio note broadcast by long
press this key or click other keys.
Engineer settings:
First your devise need to be off, then press simultaneously the intercom button and on
the voice broadcasting key remote intercom key for few seconds.
Once the devise turn on, the middle key should flash and the two other keys should be light
on. For adjusting the volume on the agent side, press briefly the key for turning up or
press for a long time for turning down.
For adjusting the volume on the public side, do the same manipulation with key.
For leaving the engineer settings, press the key for five seconds. 9
Or

Fault exclude
Why the terminal can not talk with others?
1. To realized talking with other terminals, it must be through HD recording
host. Check whether connect with HD recording host.
2. Check server mapping settings is right or not.
Why recording host can not login to the server?
1. Check whether connect with HD recording host.
2. Check the software server and the main controller is normal opened or
not. It is required to close all firewall before open the software server (including system
built-in firewall and other antivirus software firewall).
3. Check the terminal network cable and switcher whether work normal,
damaged, and disconnect or not etc;
4. Check the HD record host settings, please check the terminal ID...etc
parameters.
10
Recording
Analog recording
Window internal intercom can output analog audio, and it is ok for connect with the DVR to
make auto-recording.
Connect DCL20-65 Loop Amplifier (for OP-6505B Versions)
The DCL20-65 is an induction loop kit that can be used to equip counters or reception
desks.The system allows to meet the restrictions of the law of european equal treatment
directives while respecting the requirements of EN60118-4. The set is designed to offer
accessibility to hearing-impaired equipped with a T-position on their hearing aid.
The amplifier is designed to be discreetly attached under a desk or counter.It is equipped
with two inputs, settings and LEDs indicating the presence of power supply and loop
current.
The device incorporates an audio processing to have an automatic control of the sound
levels, avoiding loud and sudden noises.

Installation
Composition and assembly ofthe loop
The loop consists on the following 3elements: a loop cable, aloop adapter and aconnecting
cable.
The loop is ready but it is possible to disas-semble it to adapt it to the reception desk.See
below.
To disassemble the loop that will equip the counter, first unscrew the support of the elec-tronic
card.
Connect the beginning and the end of the loop cable to the circuit board (red connector).
Then plug the 50-70 cm connecting cable sup-plied to the "amplifier" connector of the adap-ter
and to the "Loop" terminal block of the am-plifier.
Your loop is now created andconnected.
Installation of the loop in the coun-
ter
1. Place the loop on the vertical and
horizontal portion of the counter as shown
in figure 1. This type of installation ensures
better coverage in front of the counter.
Figure1.
Note:
The wire supplied in the DLC20-65 kit ensures the quick installation of amagnetic
loop system in areception desk, counter or cash desk.
In order to optimize the radiation of the magnetic field and to guarantee a
. better result he wire should be placed close to the customer.
Loop amplifier
11
There are 3possibilities to place aloop in a
counter as described below, however we
strongly advise you to use the first version

2.Position the loop on the horizontal counter-
top by positionning the cable closest to the
customer.
3.Install the loop on the vertical countertop by
positioning the cable closest to the customer.
Set the loop using the binding clips supplied for this purpose.For better durability, it may be ap-
propriate to install the loop in aplastic chute.
Then connect the connecting cable to the termi- nal block "amplifier" of the connector on the
terminal block "loop" of the amplifier.
Screw the connector on the cross.
Attention, warning, danger:
The loop must not be positioned
under ametal structure.The ma-
gnetic field would be absorbed by the
metal mass and would not equip
the counter properly.There are
other solutions for installing aloop in ametal
counter (see figure 3)
For greater coverage around the counter, it is possible to install acable on the floor.The loop can
be placed in the slab (over the wire mesh), under acoating (parquet, carpet, ... etc) using a
copper tape or glued under acarpet as shown in figure 3 .
Figure3.
The wire supplied in the DCL20-K kit produces a
magnetic field radiating on aperimeter of 1.2m
which allows apeople to receive the signal
com-fortably.
Figure4.
amplifier
The pictogram with an integrated loop can be
fixed on the desk and turned to the customer’s
side to avoid disturbances due to metal (see
Figure 4). Loop amplifier
Loop1
Loop2
Loop amplifier
12
Figure 2.

Connect DCL20-65 to the main unit
General connection
To connect the supplied microphone with the kit, insert the 3.5 jack into the microphone input
1.
Connecting to an intercom or specific source:Connect your source to input 2of the DCL20.
This input supports the following sources:line, low impedance and 100Vwith an adapter.
micro / Ligne /Mass
Ligne /Mass
Jack 3,5
13
LOOP
Micro input1:
Type : Jack3,5
Feature: phantom power
Input ligne 1:
Type: Terminal Block
Input type: Line or microphone, screw connec-tion.
Input 2:
Type: Terminal Block
Input type: Line /low impedance/ 100V withan
adapter.
Loop

Conversion tables
In this manual, SI units are used to expresslengths, masses, temperatures etc.
These can be converted to non-metric units using the following information.
Table 1: lenght units conversion
Table 2: Mass units conversion
Table 3: Pressure units conversion
Table 4: temperature units conversion
25,40 mm = 25,4 mm 1 mm = 1,00000
25,40 mm = 2,54 cm 1 cm = 0,3937 po
30,48 cm = 0,3048 m1 m = 3,281 pd
1 ml = 1,609 km 1 km = 0,622 ml
1 lb = 0,4536 kg 1 kg = 2,2046 lb
1 psi = 68,95 hPa 1 hPa = 0,0145 psi
Note:
1 hPa = 1mbar
°F = 9 /5. ( °C + 32 °C = 5 /9. ( ° F 32)
14

Notes:
15

Tél : 09.81.24.00.06
Mail: contact@opus-technologies.fr
Opus Technologies —ZI Lagrange II —9 Chemin de la Vieille Ferme —33650 MARTILLAC
16

Interphone de communication digital
Guide d’utilisateur
2020
OP-6505B
17

Introduction……………………………………………………………………………………………… 5
Précautions de sécurité..……………….……………………………………………………………… 5
Le produit……………….……………………………………………………………………………………. 6
Caractéristiques………………..…………………………………………………………………….…… 6
Indication sur l’interface matérielle….……………………………………….…………….…… 7
Liste des produits fournis………………………………………………………………….………….. 8
Câblage..…………………………………………………………….………………………….…….…….. 9
Fonctionnement général.…………………………………………………………………….……… 10
Interphone local….……….……………………………………………………………….………….…. 10
Interphone àdistance………………………………………………………………….……………… 10
Réglage du mode scène…………….……………………………………………….…………………
Réglage ingénieur…………………………………………………………………………………………
10
11
Enregistrement.………………………………………..………………………………….…………….. 11
Recherche de problèmes……………………………………………………………………………… 11
DCL20-65………………………………………………………………………………………..………… 12
But……………..………………………………………………………………………………………………… 12
Public visé…………..……………………………………………………………………….…….………… 12
Alerte...………………………………………………………………………………………….….….…….. 12
Icônes….…………………………………………………………………………..…………………..……… 12
Icônes et notes..…………………………………………………………………………………………… 12
Icônes d’attention, d’avertissement et de danger….………………………..…………… 12
Description………………………………………………………………………….………….….………… 13
La gamme………………………………….………………………………………………………………… 13
Le contenu……………………………………………………………………………………….…………… 13
Conseils et sécurité………………………………………………..……….……………….…………… 13
Installation…………………………………………………………………………………..……………….14
Connexions et réglages………………………………………………………………………………… 16
Fonctionnement….…………………………………………………………………………….………… 17
Spécifications……………………………………………………………………………………………….. 18
Table des matières
18

19
Introduction
Précautions de sécurité
• Veuillez respecter l'avertissement et les conseils de sécurité pertinents.
• Veuillez prendre ce manuel dans un endroit pratique pour référence future.
Avertissement et rappel
Ce symbole signifie qu'il y a des problèmes potentiels de sécurité, cela peut
entraîner la mort ou des blessures graves si le fonctionnement est incorrect.
Ce symbole rappelle à l'utilisateur que cet appareil a joint les instructions
importantes d'utilisation et de maintenance.
Réglage et installation
• Évitez l'eau. Ne pas exposer la machine à l'eau de pluie ou à tout autre environnement taché de
liquide, sous peine de provoquer un incendie ou une électrocution.
• N'utilisez pas l'autre tension d'alimentation. Le cas contraire peut provoquer un incendie ou un
choc électrique si vous utilisez une tension plus élevée.
• Ne rayez pas le cordon d'alimentation.
• Ne pas rayer, couper ou tordre le cordon d'alimentation.
• Veuillez garder la ligne d'alimentation loin de l'objet chauffé et ne mettez pas de choses lourdes
dessus, sinon cela pourrait provoquer un incendie ou une décharge électrique.
Utilisation de l’appareil
En cas d’une anomalie :
S'il vous plaît couper l'alimentation immédiatement en trouvant les phénomènes anormaux suivants
dans l'utilisation. Si c’est le cas contactez le fournisseur. Cela peut provoquer un incendie ou un choc
électrique s'il est utilisé de façon anormale.
Voici quelques exemples :
• L'appareil interne est envahi par l'eau ou d'autre. L'appareil tombe ou le boîtier de l'appareil est
endommagé.
• Le cordon d'alimentation est endommagé (le fil est exposé ou cassé, etc.). Défaut de l'appareil (il
ne peut pas connecter le réseau, pas de son, etc.).
• N'ouvrez pas l'appareil en interne ou ne modifiez pas l'appareil. Ne faites pas d'autres intrusions
dans l'appareil.
• Ne faites pas entrer d'objets métalliques ou d'objets inflammables dans l'appareil, sinon cela
pourrait provoquer un incendie ou un choc électrique.
• Ne pas toucher quand la foudre
• Pour éviter les chocs électriques, veuillez ne pas toucher l'appareil et la prise pendant la foudre.
• Ne placez pas le récipient de liquide ou l'objet métallique sur l'appareil
• Si le récipient tombe et fait pénétrer le liquide dans l'appareil, il risque de provoquer un incendie
ou une électrocution.
• N'ouvrez pas l'appareil en interne ou ne modifiez pas l'appareil
• L'appareil interne contient des pièces haute tension, une fois ouvert le couvercle ou modification
faite sur l'appareil, sachez qu’il existe un risque incendies ou de chocs.
• Tout ce qui concerne la maintenance et la modification de l'appareil doit être effectué par du
personnel professionnel.
• L'avis de maintenance ou de longue durée sans utiliser
• Veuillez éteindre l'alimentation et débrancher la ligne d'alimentation pendant que la maintenance
ou l'appareil ne sera pas utilisé pendant 10 jours ou plus. Cela peut provoquer un choc électrique ou
des incendies si vous ne le faites pas.

Système intercom interne Haut parleur et microphone externe
20
Caractéristiques
•Technologie d'auto-contrôle du langage multi-canal DSP, évitez les grincements et dérangements
lors d’un véritable intercom full-duplex numérique.
•Conception de touches transparentes et tactiles, maintenez l'intercom sans être dérangé par les
cliquetis.
•Reconnaissance la source sonore, contrôler le bruit de l'environnement, régler automatiquement
le volume et restaurer le son original.
•Trois modes de fonctionnement (silencieux, standard, bruyant), réglable à l’aide d'une seule
touche.
•Câblage intercom externe et interne avec une ligne pour connecter le bureau, mieux résoudre les
desserrages causés par le déplacement et garder le bureau plus clair et beau.
•Conception professionnelle de structure de cavité, adoptant la cavité en métal dure pour
empêcher la résonance de machine, purifier et normaliser le bruit à transparent.
•Langage de service personnalisé, diffusion manuelle "Bonjour, bienvenue", "Merci à bientôt !”
•Supporte le mode d'enregistrement double et fournit la sortie d'enregistrement à l'hôte
d'enregistrement HD et au DVR pour traiter le stockage d'enregistrement tiers.
•LED montrant l'état réel de l'interphone de la fenêtre interne
Coordonner la fonction d'hôte d'enregistrement HD :
•Réaliser des appels à distance et recevoir des appels, interphone mains libres avec microphone
central.
•Microphone central à distance peut surveiller en temps réel les interphones de la fenêtre.
•Réception de la diffusion sur un réseau à distance unidirectionnelle.
•Interphone fenêtre interne peut effectuer un enregistrement en temps réel par la clé
d'enregistrement et il sera stocké sur l'hôte d'enregistrement HD.
•Mise à jour à distance du micrologiciel de l'interphone fenêtre dans la page Web de l'hôte
d'enregistrement HD.
Le produit
Le OP-6505 est un interphone numérique de guichet interne et externe, équipé d'interface d'entrée de
puissance, interface de communication et port de sortie d’enregistrement.
Other manuals for OP-6505B
1
Table of contents
Languages:
Other Opus Intercom System manuals