1.Attentions
Always keep the unit in vertical position and on a firm flat surface at all times.
Ensure that there is at least 300mm (1”) between the sides of the appliance and any
flammable, heating materials.
Do not place on soft surfaces.
Do not cover the appliances intake or outlet grilles.
For indoor use only.
Not suitable for use in cabinet, closet, boats, caravans or similar locations.
Leave the unit to stand for one hour before connecting to the mains supply after
transport or when it has been tilted (e.g. during cleaning).
Do not obstruct the air intakes and exhausts.
The mains supply must conform to the specification shown on the rating plate at the
back of the unit.
Avoid overloading circuits, which is caused by using more electrical amps than your
wiring can support. Overloading electrical wires can cause excessive heat and
electrical fires.
Avoid the appliance from splash.
Examine the cord carefully. Make sure that it is not punctured or frayed. Inspect the
plug to ensure that the prongs are secure and the plastic surrounding it is not cracked.
Avoid running cords under carpets and other areas where you cannot regularly check
their condition.
Avoid over-twisting, -coiling, -pulling the power cord, never use nylon or iron wire to
tide the power cord.
Do not leave appliance when plugged in, unplug from outlet when not in use and
before servicing. Connect to a grounded outlet only.
If the supply cord is damaged, it must be replaced by an approved service
representative or a similar qualified person in order to avoid a hazard.
Never use the plug to start and stop the unit. Always use switch on the control panel.
Before moving the unit, turn off all controls, then unplug and empty the water tank.
Don't use bug sprays or other flammable cleaners on the unit.
Never pour or spray water over the unit.
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.

4
STAY ALERT! Watch what you are doing and use common sense. Do not use the
appliance when you are tired, distracted or under the influence of drugs, alcohol or
medication causing diminished control.
Only a licensed professional is allowed to dismantle or modify the appliance.
Suggest to send the appliance for professional maintenance periodically.
2. Caution Points!
Do not use this unit with temperatures lower than 5oC, to prevent the possibility of a heavily
ice up evaporating coil.
Where to put the device into use
Excess moisture will travel
throughout your home, in
the same way that cooking
smells waft to every room in
the house. For this reason,
the dehumidifier should be
positioned, so that it can
draw this moist air towards it
from all over the home.
Alternatively, if you have a
serious problem in one area
When positioning the
dehumidifier, ensure that
it is placed on a level
surface and that there is
a minimum of 10 cm (4")
of space on either side
of the unit to allow for
efficient airflow.
This dehumidifier is
fitted with castors for
extra mobility, if you
We do not recommend the use
of an extension lead, so please
try to ensure that the unit is
sufficiently close to a fixed
mains socket. If it is necessary
to use an extension lead,
please ensure the diameter of
the wires of the cable is at least
1 mm2.
When the dehumidifier is in
operation, outside doors and

5
3.Operation
3.1 Plug the unit into a correct mains socket. (Please refer to the rating label at the rear of
the unit for correct voltage/frequency.)
3.2 Press ON/OFF button to turn on the unit. The compressor will start to work.
3.3 Press humidity setting button to set the working model you need: continuous
working, humidity 40%, 50%, 60% or 70%. The relative indicator will light on.
3.4 Press speed/ventilation button to set the ventilation speed, high or low. The relative
indicator will light on.
3.5 Press the TIMER button to set the operating hour you need (1~24 hours). The display
window will show the hour(s) you set as you press the TIMER button, after releasing it
for 8 seconds around, the display window will return to the room humidity. As the set
time has been reached, the compressor will stop working automatically.
3.6 DRYER function is turbo ventilation to dry the moisture in the air continuously, so it
could help to dry the laundry.
3.7
1.
Press one of the two buttons to start the energy saving mode.(60%humidity,slow wind)
3.8 If you don’t want to dry the air, just want to circulate the air or remove the odor inside the
room, please press AIR CLEAN button.
3.9 To turn off the unit, press ON/OFF button again.
3.10 Pre-setting function By pressing TIMER button but without turning on the other
functions (including ON/OFF button), you can PRE-SET the time for the machine to
work. For example, if you press the timer to '2', the unit will work automatically after 2
hours.
3.11 While the water tank is full, the compressor will stop for self-protection and the water full
indicator will turn into red.
To move the water tank, pull it out squarely from the unit.
After emptying the water tank, place the water tank into space. Make sure it is properly
positioned, in order for the 'water full' sign to go out and your dehumidifier is operating.
you can begin by positioning
the dehumidifier close to
this area and later moving it
to a more central point.
move the unit, it should
first be switched off and
the water tank emptied.
windows should be closed
when necessary for most
efficient use.

6
Please note, in case, the water tank has not been positioned well, the water full indicator will
turn into red.
4.Drainage
When the water tank is full, the compressor will stop for self-protection and the water full
indicator will turn into red.
To move the water tank, pull it out squarely from the unit.
After emptying the water tank, place the water tank into space. Make sure it is properly
positioned, in order for the 'water full' sign to go out and your dehumidifier is operating.
Please note, in case, the water tank has not been positioned well, the water full indicator will
turn into red.
Continuous drainage
When the dehumidifier is operated at very high humidity levels, the water tank will require
more frequent drainage. In this situation, it may be more convenient
to set the unit up for continuous drainage with the following
procedures:
1. Pull out the water tank.
2. Connect the drain hole with water tube of inner diameter: 11 mm.
3. Ensure the water will always drain away freely and the tube will
remain in right place. Note! In very cold weather conditions,
precautions should be taken to prevent the water tube from
freeing water tube of inner diameter 11mm.
4. Put the water tank back to its position.
STORAGE
If the unit is not in use for an extended period of time. Please:
Turing the unit off, unplug and tidy AC cord.
Completely empty the water tank and wipe it clean.
Cover the unit and store where it will not receive direct sunlight.

7
5.Maintenance
Always unplug the unit from the mains before carrying out any maintenance or cleaning of
the unit.
CLEANING THE BODY
Use soft cloth to wipe the unit clean.
Don't ever use volatile chemicals, gasoline,
detergents, chemically treated clothes, or
other cleansing solutions. These all could
possibly hurt the cabinet.
CLEANING THE FILTER
This dehumidifier is equipped with 2 filters
Always unplug the unit from the mains before carrying out any maintenance or cleaning of
the unit.
CLEANING THE BODY
Use soft cloth to wipe the unit clean.
Don't ever use volatile chemicals, gasoline, detergents, chemically treated clothes, or other
cleansing solutions. These all could possibly hurt the cabinet.
CLEANING THE FILTER
This dehumidifier is equipped with 2 filters
1. ANTI-DUST FILTER
⚫Extract the filter holder, remove the active carbon filter.
⚫Use a vacuum cleaner or tap the filter lightly for easy cleaning. If the filter is
particularly dirty, use warm water with a small amount of medium strength.
⚫Make sure the filter is completely dry before replacing.
⚫Do not expose the filter to sunlight.
2. ACTIVE CARBON FITLER (for capturing the particles of dust suspended in the air and
preventing the production of bacteria.)
The active carbon filter placed under the anti-dust filter is not washable. Its life span is
variable and depends on the ambient conditions where the unit is used. The filter should
be checked periodically and replaced if necessary.

8
6. Troubleshooting
FAQ
Please do not worry if you meet following problems in the use of dehumidifier. When
confirmed as failure, timely contact the repair.
Problems
Phenomenon/Reason
Solutions
Dehumidifier does not
work.
1.Could be a power outage.
2. The power switch is not on.
3.Maybe the fuse has blown out.
4.It’s not the definite starting up
time.
5.The water tank may be full or
not fixed well,and the light of full
water on screen is flashing.
1.Please wait for power supply.
2. Turn on the power switch.
3.Change the fuse.
4.Wait or cancel the time setting.
5.Pour out water of water tank,
then put it back.
Unsatisfied
dehumidification
effect.
1.The humidity setting is
inappropriate.
2.The front and back of the
dehumidifier may be blocked.
3.Dehumidification time may be
not enough.
4.Door and window may be open.
5.The temperature indoor is lower
than 5℃ or higher than 38℃.
1.Set appropriate humidity.
2.Clear the obstructions.
3.Keep waiting.
4.Close door and window.
5.Please use the machine in the
temperature of 5-38℃.
Turn on immediately
after shutdown,
dehumidifier does not
dehumidify.
3 minutes delay protection of
compressor.
The machine will work after 3
minutes.
There is water leak.
1.Drain connection is slack.
2.The drainage system is blocked
3.The water tank isn’t placed well.
1.Connect the drain.
2.Clean the stopper.
3.Place the water tank well.
Frost formation.
There is frost on the surface of
dehumidifier.
It’s normal, the machine can
defrost automatically.
The dehumidifier has a
slight wobble.
A slight wobble occurs when turn
on/off dehumidifier.
It’s normal phenomenon.

9
7. Packing list:
7.1 Dehumidifier *1piece
7.2 Instruction Manual *1 piece
Table of contents