Osburn 5000 User manual

READANDKEEPTHISMANUALFORREFERENCE
45548A
PrintedinCanada29‐06‐2012
INSTALLATIONANDOPERATIONMANUAL
5000
SafetytestedaccordingtoULCS627,
UL1482andASTME1509byIntertek
TestingServicesandaccordingtoOregon
AdministrativeRulesforMobileHomes
814‐23‐900through814‐23‐909
CONTACTLOCALBUILDINGORFIREOFFICIALSABOUTRESTRICTIONSANDINSTALLATION
INSPECTIONREQUIREMENTSINYOURAREA.
PLEASEREADTHISENTIREMANUALBEFOREINSTALLATIONANDUSEOFTHISPELLETFUEL‐
BURNINGROOMHEATER.FAILURETOFOLLOWTHESEINSTRUCTIONSCOULDRESULTIN
PROPERTYDAMAGE,BODILYINJURYOREVENDEATH.
www.osburn‐mfg.com
StoveBuilderInternationalInc.
250,ruedeCopenhague,St‐Augustin‐de‐Desmaures(Quebec)CanadaG3A2H3
Tel:(418)878‐3040Fax:(418)878‐3001
Thismanualisavailableforfreedownloadonthemanufacturer’swebsite.Itisacopyrighted
document.Re‐saleisstrictlyprohibited.Themanufacturermayupdatethismanualfromtimeto
timeandcannotberesponsibleforproblems,injuries,ordamagesarisingoutoftheuseof
informationcontainedinanymanualobtainedfromunauthorizedsources
.

5000PelletStoveInstallationandOperationManual
2_______________________________________________________________________________
THANKYOUFORCHOOSINGTHISOSBURNPELLETSTOVE
AsoneofNorthAmerica’slargestandmostrespectedpelletstove,woodstoveandfireplace
manufacturers,StoveBuilderInternationaltakesprideinthequalityandperformanceofallits
products.Wewanttohelpyougetmaximumsatisfactionasyouusethisproduct.
Inthepagesthatfollowyouwillfindgeneraladviceonpelletheating,detailedinstructionsforsafe
andeffectiveinstallation,andguidanceonhowtogetthebestperformancefromthisstoveasyou
buildandmaintainyourpelletheatingsystem.
Wehighlyrecommendthatourpelletburninghearthproductsbeinstalledandservicedby
professionalswhoarecertifiedintheUnitedStatesbyNFI(NationalFireplaceInstitute®)orin
CanadabyWETT(WoodEnergyTechnologyTransfer)orinQuebecbyAPC(Associationdes
ProfessionnelsduChauffage).
Congratulationsonmakingawisepurchase.
REGISTERYOURWARRANTYONLINE
Toreceivefullwarrantycoverage,youwillneedtoshowevidenceof
thedateyoupurchasedyourstove.Keepyoursalesinvoice.Wealso
recommendthatyouregisteryourwarrantyonlineat:
http://www.osburn‐mfg.com/warranty‐registration.aspx
Registeringyourwarrantyonlinewillhelpustoquicklytrackthe
informationweneedaboutyourstove.

5000PelletStoveInstallationandOperationManual
_______________________________________________________________________________3
Tableofcontents
1INTRODUCTION................................................................................................................................................... 5
1.1 About Pellet Heating............................................................................................................................................ 5
1.1.1 Top 10 Reasons for Buying a Pellet Stove ................................................................................................. 5
1.2 5000 Specifications .............................................................................................................................................. 6
1.3 Overall Exterior Dimensions ............................................................................................................................... 7
PART A – INSTALLATION........................................................................................................................................... 8
2Installation Safety Information.............................................................................................................................. 8
2.1 Installation Warnings, Cautions and Recommendations ..................................................................................... 8
2.2 Regulations Covering Pellet Stove Installation.................................................................................................. 10
2.3 Before Operating Your Stove ............................................................................................................................. 10
3Clearances to Combustible Material................................................................................................................... 11
3.1 Location of the Certification Label.................................................................................................................... 11
3.2 Minimum Clearances to Combustibles............................................................................................................... 11
3.3 Back Wall Installation........................................................................................................................................ 12
3.4 Corner Installation............................................................................................................................................. 12
3.5 Ceiling Clearances............................................................................................................................................. 13
3.6 Floor Protection................................................................................................................................................. 13
4Venting system ...................................................................................................................................................... 14
4.1 General............................................................................................................................................................... 14
4.2 Recommendations .............................................................................................................................................. 14
4.3 Equivalent Vent Length (EVL) ........................................................................................................................... 14
4.4 Termination Location......................................................................................................................................... 15
4.4.1 Permitted Termination Location............................................................................................................... 16
4.5 Installation Configurations................................................................................................................................ 17
4.5.1 Installation Warnings, Cautions and Recommendations Reminder.......................................................... 17
4.5.2 Through Wall Installation (Main Floor or Basement) .............................................................................. 18
4.5.3 Through Roof Installation......................................................................................................................... 19
4.5.4 Through a Prefabricated Chimney............................................................................................................ 20
4.5.5 Through an Existing Masonery Fireplace................................................................................................. 21
4.5.6 Through an Existing Masonery Chimney................................................................................................. 22
PART B - OPERATION................................................................................................................................................ 23
5General information ............................................................................................................................................. 23
5.1 Operation Warnings, Cautions and Recommendations ..................................................................................... 23
5.1.1 Zone Heating and How to Make It Work for You.................................................................................... 25
5.2 Combustible ....................................................................................................................................................... 26
5.2.1 Proper Fuel ............................................................................................................................................... 26
5.2.2 Where to Store Bags of Pellets................................................................................................................. 26
6Stove controls ........................................................................................................................................................ 27
6.1 General Information........................................................................................................................................... 27
6.1.1 LCD Touch Screen Controls, Operation and Configuration..................................................................... 27
6.1.2 Configuration and Operation Diagram ..................................................................................................... 29
6.1.3 Selecting the Language............................................................................................................................. 29
6.1.4 Viewing Statistics..................................................................................................................................... 29
6.1.5 Changing Temperature Unit (⁰F or ⁰C).................................................................................................... 30
6.1.6 Adjusting the Combustion Level (Heat Output)....................................................................................... 30
6.1.7 Convection Fan Speed Reduction (Optional)........................................................................................... 31
6.1.8 Selecting Manual or Thermostat Mode..................................................................................................... 32
6.1.9 Selecting the Pilot Cycle........................................................................................................................... 33
6.1.10 Filling or Purging Auger Housing............................................................................................................ 34

5000PelletStoveInstallationandOperationManual
4_______________________________________________________________________________
7Stove operation...................................................................................................................................................... 35
7.1 First Startup....................................................................................................................................................... 35
7.2 Everyday Startup................................................................................................................................................ 35
7.3 Running Out of Pellets ....................................................................................................................................... 35
7.4 Refilling.............................................................................................................................................................. 35
7.5 Shutting Down Procedure.................................................................................................................................. 36
7.6 Signs of an Overheating Stove ........................................................................................................................... 36
8MAINTENANCE.................................................................................................................................................. 37
8.1 Stove Maintenance............................................................................................................................................. 37
8.1.1 Recommended Maintenance Schedule..................................................................................................... 37
8.1.2 Cleaning the Baffle, the Heat Exchangers and the Combustion Chamber................................................ 38
8.1.3 Cleaning the Burn Pot............................................................................................................................... 38
8.1.4 Ash Removal ............................................................................................................................................ 40
8.1.5 Cleaning the Air Wash System................................................................................................................. 41
8.1.6 Glass Care................................................................................................................................................. 41
8.1.7 Replacement of Broken Door Glass ......................................................................................................... 41
8.1.8 Door Gasket Maintenance ........................................................................................................................ 42
8.1.9 Door Adjustment ...................................................................................................................................... 42
8.1.10 Exhaust Channel and Exhaust Blower Maintenance. ............................................................................... 42
8.2 Venting System Maintenance ............................................................................................................................. 44
8.2.1 Dealing With a Chimney Fire................................................................................................................... 44
8.2.2 Soot and Fly Ash ...................................................................................................................................... 44
9Troubleshooting.................................................................................................................................................... 45
9.1 Validating Status................................................................................................................................................ 45
9.2 Testing Components........................................................................................................................................... 47
9.3 Main Error Codes, Possible Causes and Solutions............................................................................................ 47
10 Wiring diagram..................................................................................................................................................... 54
11 Fuses access ........................................................................................................................................................... 55
12 Component location.............................................................................................................................................. 56
13 Exploded View And Replacement Parts............................................................................................................. 57
APPENDIX A: HORIZONTAL AND VERTICAL VENT CHART......................................................................... 61
APPENDIX B: LCD SLIDING BRACKET MOUNTING......................................................................................... 63
APPENDIX C: FLAME CARACTERISTICS ............................................................................................................ 65
APPENDIX D: INSTALLING A THERMOSTAT..................................................................................................... 66
APPENDIX E: MOBILE HOME INSTALLATION.................................................................................................. 68
APPENDIX F: COMBUSTION AIR SUPPLY ........................................................................................................... 69
Appendix G: Installing the Door Overlay.................................................................................................................... 71
OSBURN LIMITED LIFETIME WARRANTY......................................................................................................... 72

5000PelletStoveInstallationandOperationManual
_______________________________________________________________________________5
1INTRODUCTION
1.1 ABOUTPELLETHEATING
Pelletstovesofferadramaticimprovementintheconvenienceofheatingwithsolidfuel.Wood
pelletsarehandledinbagsandarethereforeeasilyandcleanlystored.Asingleloadingofapellet
stovecanprovidelonghoursofwarmth.Pelletstovesalsoprovideaspecialcomfortassociated
withwoodburning.Thecombinationoffansdeliveringwarmaircurrentsandthedirectcomfort
ofradiantheatprovidesspecialsatisfactiononacoldwinterday.Theheatprovidedisevenand
constant,duetotheautofuelfeedrespondingtoownersettings.Pelletstovesalsoofferstrong
environmentalbenefits;pelletsnotonlyreducedependenceonfinitesuppliesoffossilfuelslikeoil
andgas,buttheyalsoputtogoodusematerialsthatwouldotherwiseunnecessarilyand
expensivelyaddtoourwastedisposalproblems.
Inaddition,pelletstovesburnverycleanlyandofferthelowestemissionsofunwantedpollutants
ofallsolidfuelburningappliances.
1.1.1 TOP10REASONSFORBUYINGAPELLETSTOVE
Fuelisrelativelycheap,easytohandleandstore
Installationisrelativelyinexpensiveandflexible
Canbethermostaticallycontrolled
Canrunforlonghourswithouttheneedtorefuel
Heatoutputissteadybecausefuelfeedisregulated
Providespowerfulconvectionheat
Hasthelowestemissionsofallsolidfuels
Reducesourdependenceonfossilfuels
Pelletsarearenewablefuel
Woodpelletsaremadeof100%residualmatter(sawdust).Thiscreatesadded‐valuefrom
wastethatwouldotherwiseendupinalandfill.

5000PelletStoveInstallationandOperationManual
6_______________________________________________________________________________
1.2 5000SPECIFICATIONS
FuelTypeWoodpellets,WoodandHaypellets,Barkpelletsand
SwitchGrasspellets.
TestStandards(safety)ULCS627,ASTME1509andUL1482
Heatingcapacityrange*500to2400sqft(46to223m2)
InputBTUrange**From8500BTUto50000BTU
Hoppercapacity**70lb(32Kg)
ApproximateBurnTime*13to40hours
ShippingWeight390lb(177kg)
OverallExteriorDimensions235/8’’Wx317/8’’Dx3513/16’’H
(600mmx799mmx909mm)
Ventsystemsize3’’or4’’dependingonEVL(seeSection4.3EquivalentVent
Length(EVL))
BafflematerialStainlessSteel
Burnrate1.5lbto5.5lbperhour
Energyconsumption3Aforignitioncycle
1.8Aformaximumcontinuousoperation
Electricalrequirements120VAC15A
Controlboardfuses Main:7.5A‐250Vfast‐blowfuse
Convectionblower:5A‐250Vfast‐blowfuse
Combustionblower:3A‐250Vfast‐blowfuse
Exhaustblower:3A‐250Vfast‐blowfuse
Augermotor#1:3A‐250Vfast‐blowfuse
Augermotor#2:3A‐250Vfast‐blowfuse
Igniter:5A‐250Vfast‐blowfuse
*Burntimeandheatingcapacitymayvarysubjecttolocationinhome,chimneydraft,chimney
diameter,locality,heatlossfactors,climate,fuelsandothervariables.
**Thiscanvarydependingonpelletsize,length,anddiameter.

5000PelletStoveInstallationandOperationManual
_______________________________________________________________________________7
1.3 OVERALLEXTERIORDIMENSIONS
A:FRESHAIRINTAKEB:EXHAUST
B
B

5000PelletStoveInstallationandOperationManual
8_______________________________________________________________________________
PARTA–INSTALLATION
2INSTALLATIONSAFETYINFORMATION
2.1 INSTALLATIONWARNINGS,CAUTIONSANDRECOMMENDATIONS
PROFESSIONNALINSTALLATIONISHIGHLYRECOMMENDED.
YOUMAYNEEDTOOBTAINABUILDINGPERMITFORTHEINSTALLATIONOFTHISSTOVEAND
ITSVENTINGSYSTEM.CONSULTYOURMUNICIPALBUILDINGDEPARTMENTORFIRE
DEPARTMENTBEFOREINSTALLATIONTODETERMINETHENEEDTOOBTAINONE.WE
RECOMMENDTHATYOUALSOINFORMYOURHOMEINSURANCECOMPANYTOFINDOUTIF
THEINSTALLATIONWILLAFFECTYOURPOLICY.
THISSTOVEMUSTBECONNECTEDTOASTANDARD120V.60HZGROUNDEDELECTRICAL
OUTLET.DONOTUSEANADAPTERPLUGORSEVERTHEGROUNDINGPLUG.DONOTROUTE
THEELECTRICALCORDUNDERNEATH,INFRONTOROVERTHESTOVE.
IFTHISSTOVEISNOTPROPERLYINSTALLED,AHOUSEFIREMAYRESULT.TOREDUCETHE
RISKOFFIRE,FOLLOWTHEINSTALLATIONINSTRUCTIONSEXACTLY.
BURNINGANYSOLIDFUELSGENERATESCARBONMONOXIDEINLOWCONCENTRATION.THIS
GASISEVACUATEDBYTHEVENTINGSYSTEM.INHIGHERCONCENTRATIONS,CARBON
MONOXIDEISTOXICANDMAYCAUSEDEATH.TOPREVENTTHIS,ENSURETHATYOUR
VENTINGSYSTEMISAIRTIGHT.
THISSTOVEISMOBILEHOMEAPPROVEDANDREQUIRESINSTALLATIONOFAFRESHAIRKIT,
SOLDSEPARATELY.THESTOVEMUSTBEATTACHEDTOTHESTRUCTUREOFTHEMOBILE
HOMEANDTHESTRUCTURALINTEGRITYOFTHEMOBILEHOMEFLOOR,WALL,AND
CEILING/ROOFMUSTBEMAINTAINED.DONOTINSTALLINASLEEPINGROOM.
THISSTOVEISNOTRECOMMENDEDTOBEINSTALLEDINASLEEPINGROOM.
THISSTOVEHASBEENDEVELOPEDANDBUILTFORRESIDENTIALSUPPLEMENTARYHEAT
SOURCE.COMMERCIALANDINDUSTRIALUSEISPROHIBITEDANDWILLVOIDTHE
WARRANTY.
THEINFORMATIONGIVENONTHECERTIFICATIONLABELAFFIXEDTOTHESTOVEALWAYS
OVERRIDESTHEINFORMATIONPUBLISHEDINANYOTHERMEDIA(OWNER’SMANUAL,
CATALOGUES,FLYERS,MAGAZINESAND/ORWEBSITES).
CONNECTTHISSTOVEONLYTOALISTEDPELLETVENTFORUSEWITHSOLIDFUELORTOA
LINEDCHIMNEYCONFORMINGTONATIONALANDLOCALBUILDINGCODES.

5000PelletStoveInstallationandOperationManual
_______________________________________________________________________________9
DONOTCONNECTTHISSTOVETOANYOTHEREXISTINGVENTINGSYSTEMSERVING
ANOTHERAPPLIANCE.
DONOTCONNECTTOORUSEINCONJUNCTIONWITHANYAIRDISTRIBUTIONDUCTWORK.
THEVENTINGSYSTEMMUSTBECOMPLETELYAIRTIGHTANDPROPERLYINSTALLED.ALL
VENTCONNECTORJOINTSMUSTBESEALEDANDFASTENEDINACCORDANCEWITHTHE
PELLETVENTMANUFACTURER'SINSTRUCTIONSTOENSURECONSISTENTPERFORMANCE
ANDAVOIDSMOKEANDASHSPILLAGE.
THEVENTINGSYSTEMSHOULDBECHECKED,ATLEASTTWICEAYEARFORANYBUILDUPOF
SOOTORCREOSOTE.
NEVERBLOCKANYLOUVERSOFTHESTOVE.
IFREQUIRED,AFRESHAITKITCANBEINSTALLEDTOSUPPLYCOMBUSTIONAIRTOTHE
ROOMORSPACE(seeAppendixF:CombustionAirSupply).
MIXINGOFAPPLIANCECOMPONENTSFROMDIFFERENTSOURCESORMODIFYING
COMPONENTSISPROHIBITEDANDWILLVOIDTHEWARRANTY.
ANYMODIFICATIONOFTHESTOVETHATHASNOTBEENAPPROVEDINWRITINGBYTHE
TESTINGAUTHORITYISPROHIBITEDANDVIOLATESCSAB365(CANADA),ANDANSINFPA
211(USA).
STOVEBUILDERINTERNATIONALINC.(SBI)GRANTSNOWARRANTY,IMPLIEDORSTATED,
FORTHEPOORINSTALLATIONORLACKOFMAINTENANCEOFYOURSTOVEANDASSUMES
NORESPONSIBILITYOFANYCONSEQUENTIALDAMAGES.

5000PelletStoveInstallationandOperationManual
10______________________________________________________________________________
2.2 REGULATIONSCOVERINGPELLETSTOVEINSTALLATION
Wheninstalledandoperatedasdescribedintheseinstructions,thispelletstoveissuitableforuse
asafreestandingheaterinresidentialinstallations.
InCanada,theCSAB365InstallationCodeforSolidFuelBurningAppliancesandEquipmentand
theCSAC22.1CanadianNationalElectricalCodearetobefollowedintheabsenceoflocalcode
requirements.IntheUSA,theANSINFPA211StandardforChimneys,Fireplaces,VentsandSolid
Fuel‐BurningAppliancesandtheANSINFPA70NationalElectricalCodearetobefollowedinthe
absenceoflocalcoderequirements.
ThisstovemustbeconnectedtoapelletventsystemcomplyingwiththerequirementsforPellet
VentinthestandardsUL103,ULCS629M,ULCS609andUL641ortoacode‐approvedmasonry
chimneywithastainlesssteelflueliner.
2.3 BEFOREOPERATINGYOURSTOVE
Someminorinstallationandadjustmentarerequiredpriortouse:
Ifdesired,LCDslidingsupportcanbeinstalledontheleftatthebackofthestove;(see
AppendixB:LCDSlidingBracketMounting).
Thehandleanddoormustbeadjusted;(seesection8.1.9DoorAdjustment)
Thestovemustbeleveledusingthreadedlegs;
Thedecorativepanelsmustbeinstalled;(Refertodecorativepanelsinstructionsheet)
Thedooroverlaymustbeinstalledonthedoorframeasshown(seeAppendixG:Installingthe
DoorOverlay).
Makesurethefreshairintakebackdraftshutterworksfreely.

5000PelletStoveInstallationandOperationManual
______________________________________________________________________________11
3CLEARANCESTOCOMBUSTIBLEMATERIAL
Theclearancesshowninthissectionhavebeendeterminedbytestaccordingtoproceduresset
outinsafetystandardsULCS627(Canada),ASTME1509(U.S.A).Whenthepelletstoveisinstalled
sothatitssurfacesareat,orbeyond,theminimumclearancesspecified,combustiblesurfaceswill
notoverheatundernormalandevenabnormaloperatingconditions.
WARNING:NOPARTOFTHESTOVEMAYBELOCATEDCLOSERTOCOMBUSTIBLESTHANTHE
MINIMUMCLEARANCESSPECIFIEDONTHECERTIFICATIONLABEL.
CAUTION:NOPARTOFTHEPELLETVENTSYSTEMMAYBELOCATEDCLOSERTOCOMBUSTIBLES
THANTHEMINIMUMCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
CAUTION:DONOTUSEMAKESHIFTMATERIALSORMAKEANYCOMPROMISESWHEN
INSTALLINGTHISSTOVE.
3.1 LOCATIONOFTHECERTIFICATIONLABEL
Sincetheinformationgivenonthecertificationlabelaffixedtothestovealwaysoverridesthe
informationpublishedinanyothermedia(owner’smanual,catalogues,flyers,magazinesand/or
websites),itisimportanttorefertoitinordertohaveasafeandcompliantinstallation.In
addition,youwillfindimportantinformationaboutyourstove(model,serialnumber,etc.).You
canfindthecertificationlabelontheinnersideofthehopperlidofthestove.
3.2 MINIMUMCLEARANCESTOCOMBUSTIBLES
LETTER
CLEARANCESTOCOMBUSTIBLES
CANADAUSA
A*3″(76mm)3″(76mm)
B4″(102mm)4″(102mm)
C3″(76mm)3″(76mm)
D
Refertovent
manufacturer’s
clearances
Refertovent
manufacturer’s
clearances
I60″(1525mm)60″(1525mm)
Note:Werecommendleaving24″oneachsideofthestoveand12″atthebackofthestovein
ordertofacilitateaccessformaintenance.
*Fromthefreshairintake

5000PelletStoveInstallationandOperationManual
12______________________________________________________________________________
3.3 BACKWALLINSTALLATION
Forabackwallinstallation,inordertoallow
theLCDslidingsupporttomovefreelyand
fullyextend,youshouldallowaminimumof
4″(105mm)clearancefromthesidewall(B)
and3″(80mm)clearanceatthebackofthe
stove,fromthefreshairintake(A).
However,ifyouwishtoinstallthestovewith
minimumclearances(seetableinSection
3.2MinimumClearancestoCombustibles),
itispossibletolocatetheLCDtouchscreen
elsewherebutwithinthemaximumlength
oftheTelcowireprovided.Youcouldalso
wanttoinstalltheLCDslidingsupportonthe
leftsideofthestove(seeAppendixB:LCD
SlidingBracketMounting).
3.4 CORNERINSTALLATION
Foracornerinstallation,inordertoallowtheLCDsliding
supporttomovefreelyandfullyextend,youshouldallowa
minimumof6¼''(160mm)clearancetotheadjacentwalls
(C).However,ifyouwishtoinstallthestovewithminimum
clearances(seetableinSection3.2MinimumClearancesto
Combustibles),itispossibletolocatetheLCDtouchscreen
elsewherebutwithinthemaximumlengthoftheTelcowire
provided.YoucouldalsowanttoinstalltheLCDsliding
supportontheleftsideofthestove(seeAppendixB:LCD
SlidingBracketMounting).

5000PelletStoveInstallationandOperationManual
______________________________________________________________________________13
3.5 CEILINGCLEARANCES
ForceilingclearancesrefertothetableinSection3.2
MinimumClearancestoCombustibles.
3.6 FLOORPROTECTION
Forfloorprotectionclearancesrefertothefollowingtable.
FLOORPROTECTION
LETTERCANADAUSA
E18″(460mm)6″(155mm)
FN/A(USAonly)6″(155mm)
G8″(205mm)N/A(Canadaonly)
H8″(205mm)N/A(Canadaonly)
CAUTION:THESTOVEMUSTBEPLACEDONACONTINUOUS(GROUTEDJOINTS)
NONCOMBUSTIBLEMATERIALSUCHASCERAMICTILE*,CEMENTBOARD,BRICK,MILLBOARDOR
EQUIVALENT,ORANYOTHERAPPROVEDORLISTEDMATERIALSUITEDFORFLOORPROTECTION.
*Anytypeoftilewillrequireacontinuousnoncombustiblesheetbeneathtopreventthepossibility
ofembersfallingthroughtothecombustiblefloorifcracksorseparationshouldoccurinthe
finishedsurface,thiswouldincludefloorprotectionforbuilt‐inraisedhearths.Checklocalcodesfor
approvedalternatives.

5000PelletStoveInstallationandOperationManual
14______________________________________________________________________________
4VENTINGSYSTEM
4.1 GENERAL
Eventhoughthechimneydraftismechanical,asuitableventingsystemwillensureanaturaldraft
whichwillpreventsmokespillageinyourhomeifapoweroutageoccurs.Moreover,asuitable
ventingsystemconfigurationwillhelpgettingthebestefficiencyoutofyourstovewheninstalled
inaccordancewiththerequiredEVL(seeSection4.3EquivalentVentLength(EVL)).
Eventhebeststovewillnotfunctionsafelyandefficientlyasintendedifitisnotconnectedtoa
suitableventingsystem.
4.2 RECOMMENDATIONS
InCanada,werecommendthatyouusealistedpelletventthatmeetstheULCS‐609‐M89/ORD
C441‐M90Standard.ApelletventlistedtoULCS629Misalsosuitableforinstallationwiththis
stove.
FortheUnitedStates,werecommendthatyouusealistedpelletventthatmeetstheUL‐641
Standard.ApelletventlistedtoULC103isalsosuitableforinstallationwiththisstove.
Thisstovecanbeventedinanexistingfactory‐builtormasonrychimneywiththeadditionofa
stainlesssteelliner,providedthechimneyismorethan4”indiameter.Thelinershouldbelisted
andshouldmeettheULCS‐635/640standardinCanadaandtheUL‐1777standardintheUSA.
Refertotheinstructionsprovidedbytheventmanufacturer,especiallywhenpassingthrougha
wall,ceilingorroof.
4.3 EQUIVALENTVENTLENGTH(EVL)
Recommendedventingsysteminnerpipediameteris3”.Usea4”pipeifyouhavemorethan15
feetofEquivalentVentLength(EVL)
TocalculatetheEVLofyourinstallation,usethefollowingconversions:
QtyTypeofpipeEVLequivalent(ft)
190°elbowor“T”5
145°elbow3
1ftHorizontalpiperun1
1ftVerticalpiperun0.5
NOTE:Horizontalrunsshallnotexceed9feet.
NOTE:Neverexceed30feetofEVL.
NOTE:Ifthestoveislocatedatanaltitudeof3,000feetormore,itisrecommendedtousea4''
ventingsysteminnerdiameteriftheELVis7feetormore.

5000PelletStoveInstallationandOperationManual
______________________________________________________________________________15
HereisanexampletohelpyoucalculateEquivalentVentLength.OnthefollowingfiguretheEVL
canbecalculatedlikethis:
2horizontalrunof1’=(2X1’)X1’=2’ofEVL
1elbow90°or"Tee"=5’ofEVL
3verticallengthof4’=(3X4’)X0.5’=6’ofEVL
TotalEVL=(2’+5’+6’)=13’.
EVLislessthan15’thereforeitiscorrecttousea3’’pipe.
NOTE:DonotincludetheexteriorwallterminationintheEVLcalculation.(45°elbowand
termination)
4.4 TERMINATIONLOCATION
Terminationshouldnotbelocatedsothat
hotexhaustgasescanbeahazard.Theycan
reachtemperaturesof500ºFandcause
seriousburns.
CAUTION:TERMINATIONCOLLAR(SPARK
ARRESTER)ISMANDATORY.

5000PelletStoveInstallationandOperationManual
16______________________________________________________________________________
4.4.1 PERMITTEDTERMINATIONLOCATION
Canada:
LetterMin.
clearancesDescription
A12’’(30cm)Clearancesabovegrade,veranda,porch,deck,orbalcony
B36’’(91cm)Clearancetowindowordoorthatmaybeopened
F0’’(0cm)Clearancetooutsidecorner
H36’’(91cm)Nottobeinstalledaboveameter/regulatorassemblywithin36"(91
cm)horizontallyfromtheverticalcenter‐lineoftheregulator
I72’’(183cm)Clearancetogasserviceregulatorventoutletorwithin36’’(91cm)of
anoiltankventoranoiltankfillinlet
J36’’(91cm)Clearancetonon‐mechanicalairsupplyinlettobuildingorthe
combustionairinlettoanyotherstove
K72’’(183cm)Clearancetoamechanicalairsupplyinlet
L84’’(213cm)Clearanceabovepavedside‐walkorapaveddrivewaylocatedon
publicproperty
N36’’(91cm)Clearancetopropertyboundary

5000PelletStoveInstallationandOperationManual
______________________________________________________________________________17
UnitedStates:
NotLessthan36’’(91cm)aboveanyforcedairinletlocatedwithin120’’feet(305cm);
NotLessthan4feetbeloworhorizontallyfrom,oronefootabove,anydoor,windowor
gravityairinletintoanybuilding;
NotLessthan24’’(61cm)fromanadjacentbuildingandnotlessthan84’’(213cm)above
gradewhenlocatedadjacenttoapublicwalkway.
Otherrestrictionsmayapply,suchastheneedtomaintainaminimumdistancetoagasmeter.
SeeNFPA211forfurtherinformation.
4.5 INSTALLATIONCONFIGURATIONS
4.5.1 INSTALLATIONWARNINGS,CAUTIONSANDRECOMMENDATIONSREMINDER
PROFESSIONNALINSTALLATIONISHIGHLYRECOMMENDED
THISSTOVEUSESAPRESSURIZEDVENTINGSYSTEM.ALLVENTCONNECTORJOINTSMUSTBE
SEALEDANDFASTENED.CONSULTTHEPELLETVENTMANUFACTURER’SINSTRUCTIONTO
ENSUREPROPERINSTALLATION,CONSISTENTPERFORMANCE,ANDTOAVOIDSMOKEAND
ASHSPILLAGE.
USERTV,METALLICTAPE,ANDAMINIMUMOFTHREESELF‐TAPINGSCREWSATALLJOINT
CONNECTIONSTOENSUREATIGHTSEAL.
THECHIMNEYCONNECTORSHALLNOTPASSTHROUGHANATTICORROOFSPACE,CLOSET
ORSIMILARCONCEALEDSPACEORFLOORSORCEILING.
DONOTINSTALLAFLUEDAMPERINTHEVENTINGSYSTEMOFTHISSTOVE.
INSTALLVENTINGSYSTEMATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
THEUSEOFASPARKARRESTERATTHEENDOFTHETERMINATIONISMANDATORY.

5000PelletStoveInstallationandOperationManual
18______________________________________________________________________________
4.5.2 THROUGHWALLINSTALLATION(MAINFLOORORBASEMENT)
1. PositionstovefollowingclearancesgiveninSection3,ClearancestoCombustibleMaterialand
followingventmanufacturer’sinstructions.Thenlocatethepositionoftheexhaustpipeinthe
wall.
2. Installwallthimbleasperventmanufacturer’sinstructions.
3. Attachenoughpipinglengthtogothroughthewallthimbleandextendatleast6inches
beyondtheexteriorwall.
4. Attachcapandsealoutsidewallthimbleswithhightemperaturewaterproofsiliconesealant.
CAUTION:TOREDUCETHERISKOFSMOKESPILLAGETHERESHOULDALWAYSBEATLEASTONE
FOOTOFVERTICALRISEFOREACHFOOTOFHORIZONTALRUN.INALLCASES,ATLEAST3FEET
OFVERTICALRISEISNEEDED.
WARNING:TERMINATIONSHOULDNOTBELOCATEDSOTHATHOTEXHAUSTGASESCANBEA
HAZARD.EXHAUSTGASESCANREACHTEMPERATURESOF500ºFANDCAUSESERIOUSBURNS.
SEESECTION4.4.1PERMITTEDTERMINATIONLOCATION.

5000PelletStoveInstallationandOperationManual
______________________________________________________________________________19
4.5.3 THROUGHROOFINSTALLATION
1. Positionstovefollowingclearancesgivenin
Section3.2MinimumClearancesto
Combustiblesandfollowingvent
manufacturer’sinstructions.
2. Installacleanoutteetothestoveexhaust.
Ifnecessary,useahorizontaladditional
lengthbetweentheexhaustandthetee.If
youwishtocentertheverticalpartofthe
ventwiththestove,a45°elbowandatee
canbeusedtoroutethepipefromthe
exhausttowardsthebackcenterofthe
stove.
3. Droptheplumbboboverthecenterofthe
teeoutletandmarklocationontheceiling.
Installtheceilingsupportandthevent
pipebyfollowingtheventmanufacturer’s
instructions.
4. Alwaysfollowventmanufacturer’s
clearancesinstructionsfromcombustible
materials.Whenpassingthrough
additionalfloorsorceilings,alwaysinstalla
firestopspacer.
5. Afterliningupforholeinroof,cuteithera
roundorsquareholeinroof.Installupper
edgeandsidesofflashingunderroofing
materials.Nailittotheroofalongupper
edge.Donotnailloweredge.Sealnail
headswithflexiblewaterproofsealant.
6. Applyhightemperaturewaterproof
siliconesealantwherethestormcollar
meetsthevent.Slidestormcollardown
untilitsitsontheflashing.
7. Sealandinstallverticalroofvent.Ifrequired,
sealandinstallastormcollar.

5000PelletStoveInstallationandOperationManual
20______________________________________________________________________________
4.5.4 THROUGHAPREFABRICATEDCHIMNEY
Thebestmethodtomakeaninstallation
throughaprefabricatedchimneyistoruna3"
stainlesssteellinerinsidetheprefabricated
chimney(ora4"stainlesssteellinerdepending
ontheEquivalentVentLengthcalculatedin
Section4.3EquivalentVentLength(EVL)).
1. Positionstovefollowingclearancesgivenin
Section3.2MinimumClearancesto
Combustiblesandfollowingvent
manufacturer’sinstructions.
2. Installacleanoutteetothestoveexhaust.
Ifnecessary,useahorizontaladditional
lengthbetweentheexhaustandthetee.If
youwishtocentertheverticalpartofthe
ventwiththestove,a45°elbowandatee
canbeusedtoroutethepipefromthe
exhausttowardsthebackcenterofthe
stove.
3. Connectthepelletventtothestainless
steellineraccordingtothevent
manufacturer’sinstructions.
4. Sealandinstallverticalroofvent.If
required,sealandinstallastormcollar.
WARNING:INTHEU.S.,THEUSEOFASTAINLESSSTEELLINERISMANDATORY.INCANADA,ITIS
NOTMANDATORYBUTISSTRONGLYRECOMMENDED.
NOTE:VENTINGDIRECTLYINANOVERSIZEDCHIMNEYANDOMITTHEUSEOFASTAINLESSSTEEL
LINERCANAFFECTCHIMNEYDRAFTANDDECREASESTOVEPERFORMANCES.
This manual suits for next models
1
Table of contents
Other Osburn Pellet Stove manuals
Popular Pellet Stove manuals by other brands

Tectro
Tectro TBH 558 Brochure & specs

Heatilator
Heatilator ECO CHOICE ECO-ADV-PS35 installation manual

Napoleon
Napoleon Auburn NPS40 Installation and operating instructions

EdilKamin
EdilKamin PELLBOX SCF Installation, use and maintenance

AURIGA
AURIGA 23kw Manual for installation and operation

Lopi
Lopi Yankee PS user manual

Centrometal
Centrometal CentroPelet ZS10 Technical instructions

Enerzone
Enerzone BIO-45 MF owner's manual

United States Stove
United States Stove 58242 owner's manual

Enviro
Enviro Omega Technical manual

St. Croix
St. Croix Prescott Series Operation & maintenance manual

EURO AJPI
EURO AJPI Bernina Use and maintenance manual