OSO slimline RD User manual

146013-04 RD 09-2016
FDV - Montasje, bruksanvisning og reservedeler Side 2
Installation manual, user manual and spare parts Page 2
Slimline RD
www.oso.no
Slimline RD er lett å plassere i mindre boliger, leiligheter og hytter. Kan monteres stående på gulv (har ikke stillben) , i benk/
skap eller hengende på vegg. Veggbrakett medfølger. RD er gunstig der plassen er liten. RD 30 og 50 kan også plasseres
inne i kjøkkenbenk o.l. El-lokket er sprutsikkert, og RD kan gjerne plasseres i våtrom. Da med fast el-montasje.
Slimline RD fits easily in small spaces in residences, apartments and cabins. Can be fitted floor standing (adjustable feet not
available), in a cupboard or hanging on the wall (bracket included). El. box cover is splash proof, and the RD can be fitted in
wetrooms (direct el. connection required).
Aut. rørlegger/Plumber: ______________________________________________________ Tel.: ______________________ Dato/date: _________________
Aut. elektriker/Electrician: ____________________________________________________ Tel.: ______________________ Dato/date: _________________
Bruker er informert og mottar denne anvisning / User is informed and handed this document: Dato/date: _________________
Installert av / Installed by:
TDS - Technical Data Sheet fiche - Direct electric water heater - ErP data
Directive: 2010/30/EU Regulation: EU 812/2013 Directive: 2009/125/EU Regulation: EU 814/2013
Water heater Efficiency according to standard: prEN50440 : 2015
TRADE MARK M.T. ITEM
No. MODEL/IDENTIFIER Load
profile
ErP
Rating
Energy
eff. %
AEC
kWh/a
Thermo-
stat set °C
Storage
volume L.
OSO Hotwater AS 801 01 53 RD 30 - 2kW/1x230V S D 35 635 70 28
OSO Hotwater AS 801 01 57 RD 50 - 2kW/1x230V M D 34 1 539 75 48
OSO Hotwater AS 801 01 63 RD100 - 2kW/1x230V L D 35 2 949 75 100
OSO Hotwater AS 801 01 72 RD 150 - 2kW/1x230V XL D 35 4 783 70 143

2
Forandringer forbeholdes / Subject to change without notice
Montasje og rørkobling - Reservedeler
Reservedeler - tilleggsutstyr
Best. nr. Betegnelse Passer for NRF nr.
RG 2 kW 1” Element 230V 1-rørs Alle volum 801 5005
TS2 Std. termostat 60-90°C Alle volum 801 5823
SV 9 bar Sikkerhetsventil Alle volum 801 5741
UX 15 Blandeventil Alle volum 801 5729
AR I Anoderørsett - salth. vann For 80-300 l. 801 5381
AR II Anoderørsett - salth. vann For 30-100 l. 801 5382
AX 12 Ekspansjonskar For 30-250 l. 801 3573
MONTASJE - VIKTIG:
1. Berederen skal monteres i rom med sluk. Vannstopp-ventil med føler må ellers monteres.
2. Berederen skal monteres med adkomst som sikrer tilgang til ventiler og elektrisk utstyr. Sørg for
min. 400 mm. plass foran el-boks slik at mulighet for service sikres.
3. Inngående KV-trykk bør ha maxtrykk på 6 bar. Hvis høyere må trykkreduksjonsventil monteres.
4. Sikkerhetsventilens overløpsrør minst 18 mm. innv., med fall til sluk hvis mulig.
NB: Følgeskadeansvar gjelder kun når dette er fulgt. All rør- og elektrisk montasje skal utføres av
autorisert personell.
Utpakking - plassering:
1. Fjern emballasjepappen forsiktig. Unngå riper/bulker.
2. Montér kv-røret med blandeventil - føres ned i toppstussen og presses godt på plass. NB: Ved
saltholdig vann over 50 mg Cl/l., montér anoderørsett (se reserve-deler), v/saltinnhold over 250
mg Cl/l. bortfaller garanti.
3. Berederen plasseres på ønsket sted, enten på gulv eller vegg med medfølgende veggbrakett.
NB: Sørg for godt hold i vegg, bruk lange skruer! Berederen skal helst plasseres i rom med
sluk, hvis ikke må overløpsrør legges frostfritt og uavstengbart til sluk. Min. innv. ø18 mm.
4. Ved montasje i rom uten sluk skal vannstoppventil med føler monteres.
5. Kv- og vv-rør føres til blandeventilen, som stilles i ønsket retning og trekkes til med klemrings-
koblingen.
Viktig: Fyll bereder med vann før strøm settes på, ellers bortfaller garantien. Nyoppfylt bereder bør
gjennomspyles med vann 1 gang/uke hvis den ikke er i bruk. NB: Ved kv-trykk over 6 bar, montér
reduksjonsventil og evt. ekspansjonskar. Sjekk at alle rørkoblinger er tette - sjekkes årlig!
El-montasje:
All intern el er fabrikkmontert. RD leveres med nettkabel og støpsel. Strøm må ikke påsettes
før bereder er fylt med vann. Gjeldende versjon av NEK skal følges ved montasje.
Tømming:
Slå av strømtilførsel. Steng hovedstoppekran. Produktets sikkerhetsventil er utstyrt med en tømme-
plugg. Om berederen er montert i rom med sluk fjernes tømmepluggen og vannet renner til sluk.
For raskere tømming kan ventilens overløp åpnes ved å vri rattet med klokken til det står åpent. Om
berederen ikke er montert i rom med sluk må en 3/4” slangenippel skrues inn i overløpet. En slange
fra nippelen føres til avløp. For å stenge ventilen vris rattet videre med klokken.
R
E
S
E
T
R
E
S
E
T
M2
1
2
3
4
THERM-O-DISC
60°C90°C
80°C 70°C
Ratt
Tømmeplugg 3/8”
Anslutning til bereder
Overløp 3/4”
Sikkerhetsventil SV

3
Forandringer forbeholdes / Subject to change without notice
215
Min. 150
Vegg-
brakett
ø430
Temperaturinnstilling:
Vanntemperaturen fra berederen til
boligen stilles med rattet A. NB: Start
med å vri rattet A
mot
klokken (mot
+) til stopp, følg så diagrammet un-
der vedr. ca. antall omdreininger
som behøves for å innstille ønsket
tappevannstemperatur.
Vannet i berederen vil uansett venti-
linnstilling holde ca. 75°C for å mot-
virke legionella.
Ventilinnstilling
UX blandeventil
°C
0 1 2 3 4 5
30
35
40
45
50
55
60
65
70
75
25
UX
omdr.
1 3
2
1
2
4
RESET
R
+ ÷
S
El-skjema
230V 1-fas
Reset-knapp
TS2
termostat
Temp.
innstilling
Element
2 kW
230V
1-rørs
Rørkobling
UX blandeventil
Bereder
Toppstuss
Pakkboks
Kv
Vv
Ved elektrisk tilkobling av varmtvannsbered-
er skal gjeldende versjon av NEK 400 følges
- ved nyinstallasjon av bereder med effekt
1,5 kW eller høyere må autorisert elektriker
sørge for fast montasje. Ved rehabilitering/
utskiftning av eldre beredere kan medføl-
gende nettkabel med plugg benyttes, men
OSO anbefaler at det allikevel benyttes fast
el-montasje.
VIKTIG
! !

4
Forandringer forbeholdes / Subject to change without notice
Garanti
OSO rustfrie trykktanker garanteres fri for material- og/eller fabrikasjonsfeil i 10 år fra kjøpsdato.
El. / utstyr og ventiler garanteres i 2 år - OSO leverer ny eller reparert del fraktfritt til kunde, forut-
satt at defekt del leveres fraktfritt OSO innen 2 uker.
Viktig: Ved montering av vannbehandlingsanlegg som tilfører kjemiske midler (inhibitorer)
som for eksempel hypokloritt bortfaller garantien.
Garantivilkår:
1. Ved salt-/kloridholdig vann over 50 mg. CI./I., må anode monteres før vann påfylles. Ved salt-/
kloridholdig vann over 250 mg. Cl./l. bortfaller garantien.
2. Montasje og service er forskriftsmessig utført (se montasjeanvisning), og vann påfylles før
strøm tilkobles.
3. Dersom varmtvannsberederen ikke er i jevnlig bruk fra monteringstidspunkt, må den gjen-
nomspyles med rent vann (åpne varmtvannskranen i minst 15 min.) minst én gang i uken de
fire første ukene etter installasjon.
4. Ved kalkholdig vann over 5dh, garanteres ikke el-kolben. Levetiden forlenges hvis termostat
stilles på maks. 60°, eller kalkoppløser monteres.
5. Feil grunnet feilaktig montasje / reparasjon, frost, overtrykk, overspenning, lynnedslag eller
utsettelse for saltdannende prosesser, dekkes ikke av garantien.
6. Originale OSO reservedeler må benyttes. Laboratorievurdering av evt. skade kan bestilles.
GENERELL BRUK - VIKTIG:
Dette apparat er ikke ment for bruk av personer (inkludert barn) med reduserte fysiske eller
psykiske evner, eller mangel på erfaring og kjennskap til apparatet, med mindre de har blitt gitt in-
struksjoner eller opplæring vedrørende bruk av apparatet av en person som er ansvarlig for deres
sikkerhet. Barn bør observeres og instrueres til å ikke leke med apparatet.
Service/utskiftning:
Før service eller utskiftning av komponenter på berederen skal strømtilførselen slåes av, og
vanntrykket slippes ut. Dette gjøres ved å stenge hovedtilførselskranen til huset, deretter åpnes en
vv-kran til trykket er borte.
Alt rørarbeid skal utføres av autorisert rørlegger. Alt el-arbeid skal utføres av autorisert elektriker.
Benytt kun originale OSO reservedeler.
Årlig kontroll - første gang etter 3 mnd:
1. Sikkerhetsventil åpnes. Kontrollér at vannet renner uhindret. Steng igjen.
2. Anode (hvis montert): Steng hovedvanntilførsel og slipp ut trykk ved å åpne en vv-kran før evt.
anode sjekkes/fornyes. Anoden sjekkes ved å koble fra kv- og vv-ansl. på UX og løsne ventilen.
Løft opp og sjekk anoderøret. Bytt hvis anodebelegg er borte.
3. Sjekk at rørkoblinger samt element bak el-lokk er tette. NB: Strøm av før el-lokk demonteres!
4. Sjekk el-koblinger: Strøm av. Fjern el-lokk. Ettertrekk alle koblinger godt. Montér el-lokk før
strøm påsettes.
Feilsøking:
For lite varmtvann: Åpne rattet max på toppventilen UX. Sjekk strømtilførsel. Trykk inn resetknapp
(se el-skjema), slå først av strøm! Sjekk elementet. Sjekk lekkasje i vv-kraner eller innstøpte rør (sus
i berederen når det ikke foregår tapping).
SV 9 bar renner: Kv-trykket er over ca. 6 bar, monter reduksjonsventil og evt. AX12 ekspansjonskar.
Evt. skift ventilen.
Garantibestemmelser - Service
Best. nr. Volum - kW Passer for Dia x H mm Ansl. Volum l. Vv-kap. 40° Oppv.tid Vekt kg M³ NRF nr.
RD 30 - 2 1-2 pers. ø 430 x 460 H ½” / ø15 28 60 l. + 50 l/t* 1,0 t 12 0,08 801.0153
RD 50 - 2 1-2 pers. ø 430 x 680 H ½” / ø15 50 100 l. + 50 l/t 1,5 t 17 0,10 801.0157
RD 100 - 2 2-3 pers. ø 430 x 1210 H ½” / ø15 100 200 l. + 50 l/t 3,0 t 40 0,24 801.0163
RD 150 - 2 3-4 pers. ø 430 x 1700 H ½” / ø15 145 330 l. + 50 l/t 4,4 t 50 0,30 801.0172
RV 100 - 2 2-3 pers. 430 x 1230 H ½” / ø15 100 200 l. + 50 l/t 3,0 t 40 0,24 801.0282
Styrttapping (5-40°) (10-60°)
Tekniske data

5
Forandringer forbeholdes / Subject to change without notice
Guarantee - Unvented hot water cylinder
The OSO stainless steel inner vessel is guaranteed against material defect or manufacturing faults for a period of
10 years from the date of purchase. All other parts including, but not limited to factory tted electrical elements
(damage caused by lime scale excluded), thermostats and valves are guaranteed against material defects or
manufacturing faults for 2 years from the date of purchase. In the event of a replacement component being
required OSO Hotwater will supply such part(s) free of charge and freight paid, on condition that the defec-
tive component is delivered, fright paid to OSO Hotwater within 2 weeks of written notice being given to OSO
Hotwater of the defect. Such replacement parts shall be guaranteed under the terms of this guarantee to the
unexpired period of the aforementioned 2 year period.
Important: When installing water treatment equipment adding chemicals (inhibitors) such as hypochlo-
rite the warranty is void.
This warranty is conditional upon the OSO cylinder being installed in compliance with the OSO Installation &
Maintence Instructions, all current legislation, codes of practice and regulations governing the installation of
unvented hot water cylinders in force at the date of installation and provided that:
1. The water supply to the cylinder shall be in accordance with European Council Directive 98/83 EC at the
date of installation and not be fed from a private water supply. Pay special attention to:
Chloride content: Max. 250 mg/l
Sulphate content: Max. 250 mg/l
Combination Chloride/sulphate: Max. 300 mg/l (in total)
2. The OSO cylinder is lled with water before turning the electricity supply on to the heater elements.
3. If the newly tted water heater is not in regular use then it must be ushed through with fresh water for at
least 15 minutes (open at least one hotwater tap) once per week, during a period of at least 4 weeks.
4. The mains water supply complies with EU standards current at the date of installation and is not fed with
water from a private supply.
5. The OSO unvented cylinder has not been modied in any way other than by OSO Hotwater and is only
used for the storage of potable water.
6. No factory tted parts have been removed for unauthorised repair or replacement.
7. Defects caused by frost, excess pressure, salt dehardner process, trancient voltage, lightning strikes or
incorrect installation, repair or use, are not covered by this warranty. A laboratory evaluation of possible
defects can be ordered by the user, however the user must pay for this where the above mentioned condi-
tions have not been fullled. Evidence of the purchase date and the date of supply must also be submitted
with your claim.
8. This guarantee does not confer any rights other than those expressly set out above and does not cover
any claims for consequential loss or damage. This guarantee is oered as an extra benet and does not
aect your statutory rights as a consumer.
Annual control - first time after approx. 3 months:
1. Open safety valve. Check that water flows freely to drain. Close valve.
2. Anode (if fitted): Shut off mains water supply and release pressure by opening a HW tap. Check
anode, replace if necessary. Anode is checked by unscrewing CW and HW feed pipes to UX
valve and unscrew the valve from the water heater. Lift valve and check anode pipe. Install new
pipe if anode material has been eroded away.
3. Check that pipe connections and heating element in el. box are not dripping. Shut off power
supply before removing el. box cover! At the same time check el. connections. Tighten if neces-
sary. Refit el. box cover before turning power supply on.
Troubleshooting:
Not enough hot water: Turn knob on UX valve fully open. Check power supply. Press reset button
(see el. connection on p. 7) turn off power supply first! Check heating element. Check for leaks in
taps or pipes (hissing noise in water heater when all taps are closed).
SV 9 bar dripping: CW pressure exceeds 6 bar. Install reduction valve and an AX12 exp. vessel if
necessary. Alternatively replace safety valve.
Guarantee - Service
Product - Vol. - kW Suited for Dia x H mm Conn. Volume l. HW cap. 40° Heat up Weight kg M³ Prod. No.
RD 30 - 2 1-2 pers. ø 430 x 460 H ½” / ø15 28 60 l. + 50 l/t* 1,0 t 12 0,08 801.0153
RD 50 - 2 1-2 pers. ø 430 x 680 H ½” / ø15 50 100 l. + 50 l/t 1,5 t 17 0,10 801.0157
RD 100 - 2 2-3 pers. ø 430 x 1210 H ½” / ø15 100 200 l. + 50 l/t 3,0 t 40 0,24 801.0163
RD 150 - 2 3-4 pers. ø 430 x 1700 H ½” / ø15 145 330 l. + 50 l/t 4,4 t 50 0,30 801.0172
RV 100 - 2 2-3 pers. 430 x 1230 H ½” / ø15 100 200 l. + 50 l/t 3,0 t 40 0,24 801.0282
full drain (5-40°) (10-60°)
Technical data

6
Forandringer forbeholdes / Subject to change without notice
Installation and pipe fitting - Spare parts
Spare parts - options
Product Description Suited for Prod. No.
RG 2 kW 1” Element 230V single pipe All volumes 801 5005
TS2 Std. thermostat 60-90°C All volumes 801 5823
SV 9 bar Safety valve All volumes 801 5741
UX 15 Mixing valve All volumes 801 5729
AR I Anode kit for Chloridic water For 80-300 l. 801 5381
AR II Anode kit for Chloridic water For 30-100 l. 801 5382
AX 12 Expansion vessel For 30-250 l. 801 3573
INSTALLATION - IMPORTANT:
1. The water heater must be installed in a room with a gully. Otherwise a sensor controlled water
shut-off valve must be fitted.
2. The water heater must be positioned to allow access to valves and electrical equipment. Ensure
min. 400 mm. space in front of el. box for service purposes.
3. Incoming CW pressure should be max. 6 bar. If higher fit reduction valve.
4. Safety valve overflow pipe min. 18 mm. internally, uninterruptable, frost free and sloping to gully.
Warning: Consequential damage liability is only valid if these rules are followed. All piping and elec-
trical installation must be performed py authorized personnel.
Unpacking - positioning:
1. Remove packaging carefully. Avoid dents and scratches.
2. Install the mixing valve with CW feed pipe. Insert into top connection and press down firmly.
Important: When chloridic content in water exceeds 50 mg Cl/l. fit CW anode pipe kit (see Spare
parts). Chloridic contend exceeding 250 mg Cl/l. annuls guarantee.
3. Fit the water heater in the desired position, floor or wall hanging installation possible (use sup-
plied wall bracket). Ensure floor/wall is able to withstand the weight of the water heater when
filled with water. The water heater must be installed in a room with a gully. Otherwise a sensor
controlled water shut-off valve must be fitted - see ‘Installation’.
4. CW and HW pipes are drawn to the mixing valve which can be rotated to the desired position
before tightening the compression ring connection to the water heater.
Important: Fill unit with water before power supply is turned on, otherwise the guarantee is void.
Newly installed unit must be flushed with water once a week if not in service. Note: If incoming CW
pressure exceeds 6 bar a reduction valve and expansion vessel must be fitted if required. After instal-
lation check that all pipe connections are water tight - re-check annually.
El. installation:
All internal wiring is factory fitted. The RD is fitted with power cable and plug. Power mist not
be turned on until unit is filled with water. Local regulations must be followed when installing.
Draining:
Turn off power supply. Shut off main water supply. Open HW faucet. If the unit is installed in a room
with a gully remove the drain plug and allow the water to drain. For quicker draining open valve
overflow by turning know clockwise until it stays open. If unit is not fitted in a room with a gully a
3/4” hose nipple must be fitted to the overflow outlet. To close valve turn know further clockwise
until the valve snaps shut.
R
E
S
E
T
R
E
S
E
T
M2
1
2
3
4
THERM-O-DISC
60°C90°C
80°C 70°C
Knob
Drain plug 3/8”
Connection to tank
Overow outlet 3/4”
Safety valve SV

7
Forandringer forbeholdes / Subject to change without notice
215
Min. 150
Vegg-
brakett
ø430
Temperature setting:
The water temperature from the water
heater to the faucets can be adjusted
with the knob A. Start by turnig knob
fully counterclockwise (towards +),
then follow the diagramme below to
set the desired water temperature.
The water inside the water heater will
still keep approx. 75°C to prevent le-
gionella growth.
Valve adjustment
UX mixing valve
°C
0 1 2 3 4 5
30
35
40
45
50
55
60
65
70
75
25
UX
turns
1 3
2
1
2
4
RESET
R
+ ÷
S
El. connection
1x230V
Reset button
TS2
thermostat
Temp.
adjustment
Element
2 kW
230V
single pipe
Pipe connection
UX mixing valve
Water heater
top
connection
Packing box
Kv
Vv

OSO HOTWATER AS / OSO HOTWATER EXPORT AS
Main o f f i c e : in d u s t r i v e i e n 1, n-3300 Ho k k s u n d , no r w a y .
te l .: +47 32 25 00 00 fa x : +47 32 25 00 9 0 e-M a i l : o s o @o s o .n o
www.osohotwater.com
Table of contents
Languages:
Other OSO Water Heater manuals
Popular Water Heater manuals by other brands

HTP
HTP SuperStor Ultra Installation start-up maintenance

Aqua-Hot
Aqua-Hot AHE-100-02S -12 VDC owner's manual

Hatco
Hatco MC-10 Replacement parts list

Siemens
Siemens 9001071773 Installation and operating instructions

Chromalox
Chromalox PD444-2 installation instructions

A.O. Smith
A.O. Smith BTI 120 Installation & operation manual

REMKO
REMKO PWB 50 Operation Technology

NJ
NJ CH 01 instruction manual

Seisco
Seisco RA-14 owner's manual

Riello
Riello RBS 1S Series Installation, operation and maintenance manual

Ariston
Ariston Super Bravo 125 Installation and user guide

Solahart
Solahart GAS BOOSTED SOLAR WATER HEATER Installation and owner's manual