3
ODGSR Series Outdoor Gas Fireplace
ODGSR36A/ODGSR42 Outdoor Fireplace Install Instructions • 20007114 Rev. B • 09/17
General Information
Thisgasapplianceshouldbeinstalledbyaqualiedin-
staller in accordance with local building codes and with
current CSA-B149.1 Installation codes for Gas Burning
Appliances and Equipment.
FOR U.S.A Installations follow local codes and/or the cur-
rent National Fuel Gas Code. ANSI Z223.1/NFPA 54.
In the Commonwealth of Massachusetts, all gas ttings
and installation of this heater shall only be done by a li-
censedgastterorlicensedplumber.
FOR SAFE INSTALLATION AND OPERATION PLEASE
NOTE THE FOLLOWING:
1. This appliance gives off high temperatures and should be
locatedoutofhightrafcareasandawayfromfurniture.
2. Children and adults should be alerted to the hazards of the
high surface temperatures of this appliance and should stay
away to avoid burns or ignition of clothing.
3. Children should be carefully supervised when they are in the
same room as your appliance.
4. Undernocircumstancesshouldthisappliancebemodied.
Parts having to be removed for servicing should be replaced
prior to operating this appliance again.
5. Installation and any repairs to this appliance should be car-
riedoutbyaqualiedserviceperson.Aprofessionalservice
person should be contacted to inspect this appliance annually.
Make it a practice to have all of your gas appliances checked
annually. More frequent cleaning may be required due to
excess lint and dust from carpeting, bedding material, etc.
6. Control compartments, burners and air passages in this ap-
pliance should be kept clean and free of dust and lint. Make
sure that the gas valve and pilot light are turned off before
you attempt to clean this unit.
7. Keep the area around your appliance clear of combustible
materials,gasolineandotherammablevapor and liquids.
This appliance should not be used as a drying rack for cloth-
ing, nor should Christmas stockings or decorations be hung
in the area of it.
8. Under no circumstances should any solid fuels (wood, coal,
paper or cardboard etc.) be used in this appliance.
9. Theowofcombustionandventilationairmustnotbeob-
structed in any way.
10. Whether the appliance is installed directly on carpeting, vinyl
tile or any combustible material other than wood, this appliance
must be installed on a metal or wood panel extending the full
width and depth of the appliance.
11. This appliance requires adequate ventilation and combustion
air to operate properly.
12. Do not use this appliance if any part has been under water.
Immediatelycallaqualiedservicetechniciantoinspectthe
appliance and to replace any part of the control system or gas
control that has been under water.
13. Inspect the burner before each use of the appliance. The
burner must be replaced prior to operation if there is evi-
dencetheburnerisdamaged.Useonlyburnerspeciedby
manufacturer.
LP-cylinder enclosures, if provided by the consumer must conform
to the design parameters as detailed below.
Enclosures for LP-Gas Supply Systems
Enclosures for LP-gas supply cylinders shall be ventilated by
openingsatthelevelofthecylindervalveandatoorlevel.The
effectiveness of the opening(s) for purposes of ventilation shall
be determined with the LP-gas supply cylinder(s) in place. This
shall be accomplished by one of the following:
a. One side of the enclosure shall be completely open; or
b. For an enclosure having four sides, a top and a bottom:
1. At least two ventilation openings at cylinder valve level shall
be provided in the side wall, equally sized, spaced at 180
degrees (3.14rad), and unobstructed. Each opening shall
have a total free area of not less than 1/2 square inch per
pound (3.2 sq. cm/kg) of stored fuel capacity and not less
than a total free area of 10 square inches (64.5 sq. cm).
2. Ventilationopening(s)shallbeprovidedatoorleveland
shall have a total free area of not less than 1/2 square inch
per pound (3.2 sq. cm/kg) of stored fuel capacity and not
less than a total free area of 10 square inches (64.5 sq. cm).
Ifventilationopeningsatoorlevelareinasideall,there
shall be at least two openings. The bottom of the openings
shallbeatoorlevelandtheupperedgenomorethan5
inches(127mm)abovetheoor.Theopeningsshallbe
equally sized, spaced at 180 degrees (3.14 rad) and un-
obstructed.
3. Every opening shall have minimum dimensions so as to
permit the entrance of a 1/8 inch (3.2 mm) diameter rod.
Cylinder valves shall be readily accessible for hand operation.
A door on the enclosure to gain access to the cylinder valves is
acceptable, provided it is non-locking and can be opened without
the use of tools.
There shall be a minimum clearance of 2 inches (51 mm) be-
tweenthelowersurfaceoftheooroftheLP-gassupplycylinder
enclosure and the ground.
The design of the appliance shall be such that (1) the LP-gas
supply cylinder(s) can be connected, disconnected and the con-
nections inspected and tested outside the cylinder enclosure; and
(2) those connections which could be disturbed when installing
the cylinder(s) in the enclosure can be leak tested inside the
enclosure.
Description
TheODGSRSeriesareradiantreplaces.Donotburnwoodor
other materials in these appliances. Each model is available with
standingpilotforusewithNaturalorPropanegasunits.
Report to your dealer any parts damaged in shipment.
Adequate combustion and ventilation air must be provided.
TheowofcombustionandventilationairMUSTNOTbeob-
structed.
Provide adequate clearances around the air opening into the
combustion chamber; and adequate accessibility clearance for
servicingandproperoperation.NEVERobstructthefrontopen-
ing of the appliance.
This replace is not designed to be water tight. There-
fore, when installing this unit against an exterior wall,
the wall must be nished before setting unit in place.