Outline M5000-4 User manual

The Sound of Big Ideas
M5000-4
FOUR-CHANNEL AMPLIFIER
The Sound of Big Ideas
USER GUIDE
TEMP
READY
SIGNAL
-18dB
6dB
CLIP
dB
+32
8
-
dB
+32
8
-
M5000-4

Table of contents
2.1 Location 3
3
3
2.2 Wiring
2.3 Speaker damage
6.1 More sound and less weight
7
8
8
8
8
8
8
8
9
9
9
9
9
9
7
7
7
7
6
5
4
4
7.3 Cooling
7.2 Mounting
7.1 Unpacking
7.4 Operating precautions
7.5 Grounding
7.6 AC mains connection
8 Connections and Operation
8.1 Front panel air filters access
8.2 Front panel adjustments
8.3 Front panel monitoring
8.4 Connecting audio inputs
8.5 Connecting audio outputs
8.5.1 Lo-Z and 70V/100V operations
8.5.2 Bridge Mode Connection
1 Important safety instructions
2 Precautions regarding installation
3 Mechanical drawings
4 Interfaces
5 Welcome
6 Description
7 Installation
M5000-4
User Guide
9 Protection 10
9.1 Turn on/Turn off muting 10
9.2 Short circuit protection 10
9.3 Thermal protection 10
9.4 Thermal warning 10
9.5 Thermal shutdown 10
9.6 DC fault protection 10
9.7 Input/output protection 11
10 User Maintenance 11
10.1 Cleaning 11
10.2 Service 11
10.3 Dust Removal 11
11 Warranty 11
11.1 Product warranty 11
11.2 Repair or replacement 11
11.3 Cost and responsibility of transport 11
11
13 Specifications 12
12 Power rating
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it E-Mail: [email protected]
2
The Sound of Big Ideas

1 Important safety instructions
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT. NO
USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR
MOISTURE. OBJECTS FILLED WITH LIQUIDS, SUCH AS VAS-
ES, SHOULD NOT BE PLACED ON THIS APPARATUS.
TO COMPLETELY DISCONNECT THIS APPARATUS FROM
THE AC MAINS, DISCONNECT THE POWER SUPPLY CORD
PLUG FROM THE AC RECEPTACLE.
THE MAINS PLUG OF THE POWER SUPPLY CORD MUST
REMAIN READILY ACCESSIBLE.
SAFEGUARDS: This unit has been engineered and manufactured
to assure your personal safety. Improper use can result in potential
electrical shock or fire hazards. In order not to defeat the safe-
guards, observe the following instructions for its installation, use
and servicing.
uRead these instructions.
uKeep these instructions.
uHeed all warnings.
uFollow all instructions.
uDo not use this amplifier near water.
uClean only with a dry cloth.
uEnsure a proper ventilation.
uInstall in accordance with Outline instructions.
uDo not install near any heat sources or apparatus that
produce heat.
uProtect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.
uDo not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
uUnplug this amplifier during lightning storms or when unused
for long periods of time.
uContact the authorized service center for ordinary and
extraordinary maintenance.
uOnly use attachments/accessories specified by Outline .
NOTES: This equipment has been tested and found to comply
by Competent Body (Directive 2004/ 108 / EC) pursuant to the
product family standard for audio professional use: EN 55103-1
and EN 55103-2 standard.
This equipment has been tested and found to comply by Notified
Body 2014 (Directive 2006/ 95 / EC) pursuant to the audio appa-
ratus safety requirements: EN 60065 and EN 6006/A1 standard.
EXPLANATIONS OF GRAPHICAL SYMBOLS
The Lightning Flash with arrowhead symbol within an
equilateral triangle is intended to alert the user to the
presence of uninsulated “dangerous voltage” within the
product enclosure that may be of sufficient magnitude to
constitute a risk of shock to persons.
The Exclamation Point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the product.
2.1 Location
Install the amplifier in a well-ventilated location where it
will not be exposed to high temperature or humidity.
Do not install the amplifier in a location that is exposed to direct
sun rays, or near hot appliances or radiators. Excessive heat can
adversely affect the cabinet and internal components. Installation
of the amplifier in a damp or dusty environment may result in
malfunction or accident.
Placing and using the amplifier for long periods of time on
heat generating sources will affect its performance. Avoid
placing the amplifier on heat generating sources. Install this am-
plifier as far as possible from tuners and TV sets. An amplifier
installed in close proximity of such equipment may experience
noise or generic performance degradation.
No naked flame sources such as lighted candles should be
placed on the amplifier.
Do not spill water or other liquids into or on the amplifier.
WARNING
To prevent fire or electric shock:
uThe ventilation openings must not be impeded by any item
such as newspapers, tablecloths, curtains etc; keep a distance
of at least 50 cm from the front and rear ventilation openings
of the amplifier.
uDo not expose this amplifier to rain or moisture.
uThis equipment must not be exposed to dripping or splashing
liquids: objects filled with liquids, such as vases, must not be
placed on the amplifier.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN !
2 Precautions regarding installation
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Professional Amplifier M5000-4

2.2 Wiring
This device must be powered exclusively by earth con-
nected mains sockets in electrical networks compliant to
the IEC 364 or similar rules. It is absolutely necessary to verify this
fundamental requirement of safety and, in case of doubt, require
an accurate check by qualified personnel.
OUTLINE cannot be considered responsible for eventual
damages caused to persons, things or data due to an improper
or missing ground connection.
uBefore powering this amplifier, verify that the correct voltage
rating is being used.
uVerify that your mains connection is capable of satisfying the
power ratings of the device.
uDo not use this amplilfier if the electrical power cord is frayed
or broken.
uDo not remove the cover. Failing to do so will expose you to
potentially dangerous voltage.
uProvide a sectioning breaker between the mains connections
and the amplifier. The suggested device is a 16A/250V AC, C
or D curve, 10 kA.
uSwitching mode amplifier is capable of producing hazardous
output voltages. To avoid electrical shock, do not touch any
exposed speaker wiring while the amplifier is operating.
2.3 Speaker damage
Outline switching mode amplifiers are among the most
powerful professional amplifiers available and are capable
of producing much more power than many loudspeakers can han-
dle. It is the user’s responsibility to use speakers suitable to the
amplifier and to use them in a sensible way that will not cause
damage.
Outline will not be held responsible for damaged speakers.
Consult the speaker manufacturer for power handling recom-
mendations.
Even if you reduce the output volume using the amplifier’s
front panel attenuation controls, it is still possible to reach full
output power if the input signal level is high enough.
A single high-power tone can damage high frequency drivers
almost instantaneously, while low frequency drivers can usually
withstand very high, continuous power levels for a few seconds
before they fail. Reduce power immediately if you hear any
speaker “bottoming out”: harsh pops or cracking distortion that
indicate that the speaker voice coil or diaphragm is striking the
magnet assembly.
Outline recommends that you use amplifiers in this power
range for more headroom (cleaner sound) rather than for in-
creased volume.
This manual contains important information on operating your
Outline amplifier correctly and safely. Please read it carefully
before operating your amplifier. If you have any questions, con-
tact your Outline dealer.
The Sound of Big Ideas
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it E-Mail: [email protected]
4

3 Mechanical drawings
482
337,3
44,1
437,6
379,5
FIGURE 1: M5000-4 mechanical drawing. All dimensions in millimiters.
TEMP
READY
SIGNAL
-18dB
6dB
CLIP
dB
+32
8
-
dB
+32
8
-
M5000-4
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Professional Amplifier M5000-4

1. Channel 1 input attenuator
2. Channel 1 meter LEDs
3. Channel 2 meter LEDs
4. Channel 2 input attenuator
5. On/off power switch
6. Channels 1&2 ready LED
7. Channels 1&2 temperature warning LED
8. AC mains power plug
9. Air vents
10. Channels 3&4 line input XLR connector
11. Channels 1&2 line input XLR connector
12. Channel 4 output Speakon connector
13. Link switch channels 3-4
14. Channel 3 output Speakon connector
15. Channel 2 output Speakon connector
16. Link switch channels 1-2
17. Channel 1 output Speakon connector
FIGURE 2: M5000-4 front panel view.
FIGURE 3: M5000-4 rear panel view.
1 2 3 4
6 7
5
8
1613 1714
910 11
1512
TEMP
READY
SIGNAL
-18dB
6dB
CLIP
dB
+32
8
-
dB
+32
8
-
M5000-4
PAT. PEND.
Made in Italy
4 Interfaces
The Sound of Big Ideas
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it E-Mail: [email protected]
6

M5000-4
User Guide
5 Welcome
Congratulations on buying a Outline M5000-4 amplifier!
Outline is a leading company in the field of high efficiency
audio power management. The Outline Class D technology
has changed the way the world looks at professional audio
amplification: no other amplifier’s performance comes close for
applications demanding high power and long term reliability.
Thanks to amazing reductions in heat output and weight, without
sacrificing output powers, Outline amplifiers can be used in an
unlimited range of PA applications such as opera houses, theaters,
churches, cinema, and theme parks.
applications. This amplifier offer smaller dimensions, lighter weight
and the traditionally amazing sound quality and reliability of all
Outline products. M5000-4 amplifier have power ratings suitable for
a vast range of common applications including 70V/100V distributed
line systems
M5000-4 amplifier is specifically designed for touring and live
6.1 More sound and less weight
Switching mode technology based amplifiers are highly
efficient, delivering greater power to speakers with reduced heat
dissipation: typical running efficiency of output stages is 95%, with
only 5% of input energy dissipated as heat. This allows for smaller
dimensions, weight and power consumptions.
Contrary to conventional amplifiers which achieve highest
efficiency only at full rated power output, Class D efficiency is
almost independent of output level. Music has an average power
density of 40% of its peak value; this means that other (non-
class D) amplifiers can easily generate 10 times more heat than
Outline products for the same sound pressure level.
The M5000-4 amplifier is designed to work with lo-Z (from
4 Ω) and with 70V/100V distributed lines. It can deliver up to
1250 W per channel (at 4 or 250 0 W in bridge mode on 8 Ω. Ω)
Outline amplifiers deliver crystal-clear highs, and a tight,
well-defined low end: the most accurate reproduction of an audio
signal. Solid time proven design features ensure extremely high
performance in terms of super low total harmonic distortion,
optimal frequency response, high power bandwidth and damping
factor across a vast number of application scenarios.
Multi patented application of Pulse Width Modulation (PWM)
high frequency sampling techniques is just one of the many factors
contributing to the M5000-4 high performance ratings across the
audio bandwidth.
The M5000-4 offers complete protection against any possible
operation error. It is designed to work under a large range of
possible conditions, delivering maximum power with maximum
safety and an outstanding long term reliability. Anticipating
potential problems at the design stage means your show always
goes on!
7.1 Unpacking
Carefully open the shipping carton and check for any noticeable
damage; the FIGURE 4 shows the packing view. Every Outline
amplifier is completely tested and inspected before leaving the
factory and should arrive in pristine condition. In the unlikely event
that you should encounter any damage, please notify the shipping
company immediately. Be sure to save all packing materials for the
carrier’s inspection.
The M5000-4 amplifier box contains the following:
u 1 amplifier.
u1 x AC Mains cord with 3-pin plug 15 A for US or
IEC ‘Schuko’ 16 A for every other nation.
u 1 x User Guide.
amplifier
manual
mains cable
FIGURE 4: M Series package
6 Description
7 Installation
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Professional Amplifier M5000-4

7.2 Mounting
All Outline amplifiers are designed for standard 19” rack
mounting with four front panel holes and two rear-lateral holes. In
order to limit the risk of mechanical damages, amplifiers must be
fixed to the rack using both frontal as well as rear mounting holes
(see FIGURE 9).
7.3 Cooling
All Outline amplifiers implement a forced-air cooling system
to maintain low and constant operating temperatures. Drawn by
an internal fan, air enters through the slots in the front panel and
is forced over all components, exiting at the back of the amplifier.
The amplifier’s cooling system features an “intelligent” variable-
speed DC fan which is controlled by heat sink temperature sensing
circuits: the fan speed will increase only when the temperature
recorded by the sensors rises over carefully predetermined values.
This ensures that fan noise and internal dust accumulation are kept
to a strict minimum. Should however the amplifier be subject to
an extreme thermal load, the fan will force a very large volume
of air through the heat sink. In the extremely rare event that the
amplifier should dangerously overheat, sensing circuits shut down
all channels until the amplifier cools down to a safe operating
temperature. Normal operation is resumed automatically without
the need for user intervention.
Caution regarding heat escape should be exercised when
mounting M5000-4 amplifier. Exhaust cooling air is forced out
through the rear of the chassis (see FIGURE 5); make sure there
is enough space around the back of the amplifier for this air to
escape. M5000-4 amplifiers can be stacked one on top of the other
due to the efficient cooling system they are equipped with. There
is however a safety limit to be observed: in case a rack with closed
back panels is used, leave one rack unit empty every four installed
amplifiers to guarantee adequate air flow.
7.4 Operating precautions
Make sure the power switch is off before attempting to make
any input or output connections.
Make sure the AC mains voltage used is within the acceptable
operating voltage range specified in the M5000-4 documentation
(factory selected 115 V / 230 V ±15%), depending on your country
mains standard. Damage caused by connecting the amplifier to an
improper AC mains voltage is not covered by the warranty.
By using good quality input and speaker cables, the likelihood
of erratic signal behavior is reduced to a minimum. Whether you
make them or buy them, look for good quality wires, connectors
and soldering techniques.
7.5 Grounding
There is no ground switch or terminal on the M5000-4 amplifier.
All shield terminals of input connections are directly connected to
the chassis. This means that the unit’s signal grounding system is
automatic. In order to limit hum and/or interference entering the
signal path, use balanced input connections.
In the interests of safety, the unit MUST always operate with
electrical safety earth connected to the chassis via the dedicated
wire in the 3-wire cable. Never disconnect the ground pin on the
AC mains power cord.
7.6 AC mains connection
The AC Mains connection is made via the IEC type connector
on the back of the amplifier. Please make sure your AC mains
power source operates within the voltage limits indicated on this
manual (factory selected 115 V / 230 V ±15%).
Safety warning!
Ground wires must be connected!
Do not use adapters that disable grounding.
operation. For optimal amplifier performance, it is important to
This section provides information on amplifier connection and
under stand the meaning of the infor mation that M5000-4
amplifier can provide regarding its status and configuration.
8.1 Front panel air filters access
The grey front panel of M5000-4 amplifier can be removed
to access the air filters. This is useful when the air filters need to
be cleaned due to dust accumulating and clogging the filters thus
hindering proper air circulation vital for cooling purposes.
air flow
mounting
holes
brackets
FIGURE 5: M5000-4 air flow.
open the lock and
insert the plug
lock the plug
FIGURE 6: AC mains plug connection.
8 Connections and Operation
The Sound of Big Ideas
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it E-Mail: [email protected]
8

To take off the grey colored front panel, remove the two
screws highlighted in with a Philips screwdriver. The panel will
easily separate from the amplifier exposing the sponge-like air
filters.
Before replacing the front panel, remember to reposition the
air filter on the chassis by placing it on its designated area, then
reposition and tighten the two frontal screws.
8.2 Front panel adjustments
The front panel of M5000-4 amplifier has one stepped
attenuation pot for each channel. Turning the pot counterclockwise,
the user can modify the level of the input signal in steps corresponding
to a gain reduction ranging in:
-∞, 4, 14, 18, 20, 22, 24, 26, 28, 30, 32 dB.
8.3 Front panel monitoring
The M5000-4 front panel provides important information on
the state of the amplifier. It is important to know and understand
the meaning of every front panel indicator LED in order to have
crucial information on the amplifier status.
There are two sets of LEDs on the M5000-4 front panel:
channel indicators and status indicators. Channel indicators: each
channel has its own column set of 4 LEDs. The top LED is red, and
the following three are green. Status indicators: each channel pair
has one set of two green status indicator LEDs.
The function of both families of LEDs is summarized in TABLE 1.
Channel indicators
LED Color Solid ON Label
RED
Channel output level has
reached clipping limits
OR
Short circuit protection has
been engaged
CLIP
GREEN Channel output level is above
-6 dB of max output level -6 dB
GREEN Channel output level is above
-18 dB of max output level -18 dB
GREEN Input signal presence SIGNAL
Status indicators
LED Color Solid ON Label
GREEN Channel is ready READY
YELLOW Output power is being
reduced due to heat sink *
temperature exceeding 75° C TEMP
* Should the temperature exceeds 85° C, the LED will stay on and the channel will be muted.
The amplifier will resume normal functioning and the LED will turn off automatically when the
temperature falls below 75° C.
TABLE 1: M5000-4 LEDs char t.
8.4 Connecting audio inputs
Audio input connections are made via four XLR connectors
found on the rear of the amplifier. Signal looping (i.e. link thru) is
possible using the two XLR male connectors which are also found
on the back panel. The Link on/off buttons allows to connect input
channels 1 and 2 (and/or channels 3 and 4) in parallel.
8.5 Connecting audio outputs
WARNING!
Lethal voltage levels may be present at the loudspeaker
connectors when the amp is turned on!
All output connections are made via speakON connectors.
Both bridge as well as single channel output connection modes
are available. In the single channel mode wiring, the 1+ pin of the
connector corresponds to the positive output of the channel, the
1– to ground (see FIGURE 9); for bridge mode refer to Section
8.5.2.
The M5000-4 amplifier manage bridge and single channel
mixed configuration; for example, channels 1 and 2 can be set
in bridge mode, and channels 3 and 4 single-ended.
M5000-4 amplifier is designed to be connected both to lo-Z
loudspeakers as well as hi-Z, 70V / 100V distributed lines directly.
8.5.1 Lo-Z and 70V/100V operations
High impedance loudspeakers can be paralleled in 70V/100V
distributed lines and directly managed.
High output voltage per channel g uarantees direct connection
to hi-Z loudspeakers in a line (see FIGURE 9).
8.5.2 Bridge Mode Connection
Bridge mode connection of outputs is possible only in lo-Z
operational mode. Bridging of adjacent channels is possible for the
following pairs: channels 1 with 2 and channels 3 with 4.
Bridging is NOT possible for other pairs, for example channels
1 and 3.
FIGURE 7: Unscrew and remove the front panel.
GND
Balanced input Unbalanced input
COLD –
HOT +
1
2
3
GND
HOT +
1
2
3
FIGURE 8: Balanced and unbalanced input XLR connections.
TEMP
READY
SIGNAL
-18dB
6dB
CLIP
dB
+32
8
-
dB
+32
8
-
M5000-4
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Professional Amplifier M5000-4

In order to set the output in bridge mode:
uparallel the input by pressing on the link button;
uconnect the loudspeaker to just one speakON: 2+ pin is the
positive and the 2– the negative;
uminimum load impedance shall be 8 Ω
1+
2+
1–
2–
1+
2+
1–
2–
1+
2+
1–
2–
speakON Single channel mode
connector
speakON
connector
speakON
Single channel mode
connector
(distributed line)
Bridge mode
FIGURE 9: Loudspeaker wiring;
a) single channel mode, low impedance loudspeaker;
b) single channel mode, high impedance loudspeaker; c) bridge mode.
a
b
c
9 Protection
In order to protect your device and your speakers from
accidental damage, M5000-4 amplifier include an extensive
automatic protection system. In the following sections, potentially
dangerous scenarios and the amplifiers’ corresponding protective
response are explained in detail.
9.1 Turn on/Turn off muting
Class D amplifiers may cause severe speaker damage at power
up due to the high voltage levels at the output stage. In order to
avoid this, the outputs are muted for less than 2 seconds (less
than 5 seconds for DSP models) after turn on. Similarly, turning
off the amplifier can cause the same problem: outputs are muted
immediately at turn off.
9.2 Short circuit protection
Short circuits or very low impedance loads may destroy the
output stage of any amplifier. In order to protect the amplifier
from the dangerously high current surges arising from accidental
output short circuits or low impedance loads, all M series amps
block channel activity when the current drawn from the load rises
above a set value. The channel is muted for 2 seconds after which
the amplifier will unmute the channel and check whether the
current draw is still over the safety threshold. Should this be the
case, the amplifier will mute the channels for another 2 seconds
and the procedure will reiterate. The red “CLIP” LED will be
turned off only when the output current draw will have returned
within safe limits.
9.3 Thermal protection
Outline M5000-4 amplifier have variable speed fans to assist
cooling. If for some reason the cooling system can’t dissipate
the produced heat correctly, a thermal protection system is
automatically activated to avoid permanent damages. Every
channel pair has a temperature sensor on the output stage
heat sink. Two different protection strategies are implemented
depending on the severity of the overheating. In order to protect
internal components, the amplifier may automatically reduce
output power until the internal temperature returns to safe levels.
9.4 Thermal warning
If the heat sink reaches a temperature of approximately 75°C,
the front panel red “TEMP” LED corresponding to the overheated
channel pair turns on to warn the user of a potentially dangerous
thermal event. Output power is reduced to prevent damages to
the output stage.
9.5 Thermal shutdown
If the heat sink temperature rises above 85°C, the thermal
sensing circuitry will mute each power section of each
compromised channel pair. Only after the heat sink has cooled
down to below 75°C the channel pair will automatically unmute
and the red “TEMP” LED will be turned off.
9.6 DC fault protection
In order to protect your speakers from mechanical damage
caused by a DC signal coming from the amplifier’s output, a DC
detection circuit is placed between the amplifier’s output stage
and power supply. If a DC signal or excessive subsonic energy
appears at a channel output an instantaneous protection circuit
will mute the compromised channel pair. The red “CLIP” LED will
turn on to signal that protective measures have been engaged.
The Sound of Big Ideas
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it E-Mail: [email protected]
10

9.7 Input/output protection
Interference protection is implemented in the M Series to limit
out of band noise carried by the input lines. Disturbing frequencies
can interact with the output stage, causing unpredictable amplifier
behavior. A filtering system is used to stop infrasonic and VHF
signals from entering the signal path.
10 User Maintenance
10.1 Cleaning
Before attempting to clean any part of the amplifier, first
disconnect the AC main source. Use a soft cloth and mild non-
abrasive solution to clean the faceplate and chassis.
WARNING! Never let any liquid reach the internal parts of
the amplifier.
10.2 Service
There are no user-serviceable parts in your amplifier. Refer
servicing to qualified technical personnel. If your amplifier needs
repair contact your Outline dealer. You can also contact the
Outline Technical Service department.
goods covered by product warranty at its sole discretion and as
it deems best.
11.3 Cost and responsibility of transport
The purchaser (or end user/customer) is solely responsible
for all transportation costs and risks associated with sending
warranty covered goods to Outline or its Authorized Service
Center. Outline will assume full responsibility and cover all costs
incurred to send the goods back to the purchaser (or end user/
customer).
10.3 Dust Removal
In dusty environments, the front side air filters clog with dust
after prolonged use. The dust gathered in the filters will interfere
with cooling. You may use compressed air to remove the dust
from filters. To remove air filters please refer to the front panel
removal procedure (see Section 8.1). Air filter cleaning should be
scheduled according to the dust levels in the amplifier’s operating
environment.
11 Warranty
11.1 Product warranty
Outline guarantees its manufactured products to be free from
defective components and factory workmanship for a period of 48
(forty eight) months, starting from the date of purchase printed on
Outline (or any of its Authorized Dealer’s) invoice to the end
customer. All warranty repairs and retrofits must be performed at
Outline facilities or at an Authorized Service Center at no cost
for the purchaser. Warranty exclusion: Outline ’s warranty does
not cover product malfunctioning or failure caused by: misuse,
abuse, repair work or alterations performed by non-authorized
personnel, incorrect connections, exposure to harsh weather
conditions, mechanical damages (including shipping accidents), and
normal wear and tear. Outline will perform warranty services
provided that the product is not damaged during transportation.
11.2 Repair or replacement
Outline reserves the right to repair or replace any defective
12 Power rating
Single-channel mode Distributed lines Mono-bridge
mode
4 Ω8 Ω70 V 100 V 8 Ω
1250 W 750 W 1000 W 11250 W 22500 W
1 with an external high pass filter and output voltage limiter.
2 with an external high pass filter.
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Professional Amplifier M5000-4

General
Number of channels 4 mono, bridgable per channel pair
*
Max output power per channel single channel mode bridge mode
4 Ω / Ch 8 Ω / Ch 70 V ** 100 V 8 Ω / Ch pair
1250 W 750 W 1200 W 1250 2500 W
Max output voltage 135Vpeak / 65 A peak 270Vpeak / 65 A peak
AC Mains Power
Power supply Universal, regulated switch mode
Nominal power requirements AC 115 V - 230 V (factory selection), 50/60 Hz
Operating range AC 97 V - 264 V
Inrush current < 28 A rms
Consumption / current draw 230 V 115 V
Energy save on 64 W 0.51 A 64 W 0.6 A
Energy save off 905 W 5.8 A 605 W 11.6 A
I/8 of max power @ 8 Ω1772 W 11.1 A 1772 W 22.2 A
Thermal
Environmental operating temperature 0° - 45° C / 32° - 113° F
Thermal dissipation Fan, variable speed, temperature controlled front to rear airflow
230 V
Idle 218 BTU/h 55 kcal/h
I/8 of max power @ 4 Ω955 BTU/h 241 kcal/h
I/4 of max power @ 4 Ω1781 BTU/h 449 kcal/h
Audio
Gain 32 dB, 30 dB, 28 dB, 26 dB, 24 dB, 22 dB, 20 dB, 18 dB, 14 dB, 4 dB, -∞, user selectable
Frequency response 20 Hz - 20 kHz ±1 dB @ 1 W, 8 Ω
S/N ratio (amplifier section) > 110 dB (20 Hz - 20 kHz, A weighted)
Crosstalk separation >70 dB @ 1 kHz, 4 Ω
Input sensitivity @ 8 Ω1.94 V rms / +8 dBu
Max input level 6 V rms / +17.8 dBu
Input impedance 10 kΩ balanced
THD+N / DIM100 IMD < 0.02% (typically <0.005%) @ 4 Ω
Slew rate 40 V/µs @ 8 Ω input filter bypassed
Damping factor > 5000 @ 100 Hz
Front panel
Indicators 4 LEDs per channel: 3 x green, 1 x red; 4 status LEDs: 2 x green, 2 x yellow
Controls 1 stepped level attenuator pot per channel; mains switch
Maintenance Dust filter foam behind front panels
Rear panel
Controls 2 x link switch, linking analog inputs 1&2 and 3&4
Input / Output connectors 4 x balanced Neutrik® XLR female
4 x Neutrik® Speakon NL4MD
AC mains IEC C13 16 A connector; AC mains cord with 3-pin plug 15 A for US, IEC Schuko 16 A for every other nation
Construction
Dimensions L x W x H: 483 mm x 44.5 mm x 379 mm / 19” x 3.5” x 14.9”
Weight 7.3 kg (16 lb)
* EIAJ Test Standard, 1 kHz, 1% THD, all channels driven. ** External high-pass filter required.
13 Specifications
70 V distributed line
100 V distributed line
With an external high pass filter and peak limiter
With an external high pass filter
The Sound of Big Ideas
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it E-Mail: [email protected]
12
Outline carries out on-going research for product improvement. New materials, manufacturing methods and design upgrades are
introduced to existing products without prior notice as a routine result of this philosophy. For this reason, any current Outline product
may differ is some aspect from its description, but will always equal or exceed the original design specifications unless otherwise
stated.
© Outline 2013
Operating manual product code: Z OMM5000-4
Release: 020813
Table of contents
Other Outline Amplifier manuals

Outline
Outline M2800-4 User manual

Outline
Outline GTA series User manual

Outline
Outline TFive User manual

Outline
Outline T4 User manual

Outline
Outline L3000E User manual

Outline
Outline PRO 408 MK IV User manual

Outline
Outline TTM Series User manual

Outline
Outline Twin-Pulse Series User manual

Outline
Outline L3000 User manual

Outline
Outline NEWTON User manual