Outline TTM Series User manual

OPERATING MANUAL
TTM SERIES
MULTI-PURPOSE AMPLIFIER
PLATFORM

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
2
TTM Series Operating Manual
Version: 2.0
Release date: 2023/03/31
© Outline 2023. All rights reserved.
Refer all servicing to qualied personnel, through your Outline dealer.

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
3
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS............................................................................................... 4
SAFETY WARNINGS........................................................................................................................ 4
REGULATORY COMPLIANCE STATEMENTS...................................................................................... 6
EC DECLARATION OF CONFORMITY................................................................................................. 7
PRELIMINARY OPERATIONS ............................................................................................................ 8
PACKAGE LIST................................................................................................................................ 8
LOCATION ....................................................................................................................................... 8
COOLING......................................................................................................................................... 8
CLEANING ...................................................................................................................................... 8
AC MAINS SUPPLY ......................................................................................................................... 9
CONNECTIONS ................................................................................................................................. 9
SIGNAL GROUNDING ..................................................................................................................... 9
INPUT AND OUTPUT CONNECTIONS ............................................................................................ 9
DIGITAL AUDIO CONNECTION ....................................................................................................... 9
LINK OUT CONNECTORS ............................................................................................................... 9
BASIC OPERATIONS ......................................................................................................................... 9
SWITCHING THE AMPLIFIER ON ................................................................................................... 9
FRONT PANEL CONTROLS .......................................................................................................... 10
HOME............................................................................................................................................ 10
LEVEL AND DELAY ....................................................................................................................... 10
MATRIX ......................................................................................................................................... 10
SOURCE SELECT.......................................................................................................................... 10
SNAPSHOTS ................................................................................................................................. 10
OUT CONFIG ................................................................................................................................. 10
SPEAKER PRESET........................................................................................................................ 11
NET CONFIG ................................................................................................................................. 11
NODE INFO ................................................................................................................................... 11
POWER OFF.................................................................................................................................. 11
FW UPDATE .................................................................................................................................. 11
NETWORKING..................................................................................................................................11
IP ADDRESSING ........................................................................................................................... 11
ARMONIAPLUS SYSTEM DESIGN ....................................................................................................12
OVERALL DIMENSIONS ...................................................................................................................12
FRONT PANEL .................................................................................................................................13
REAR PANEL ...................................................................................................................................13
PINOUTS..........................................................................................................................................14
NOTES .............................................................................................................................................15

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
4
IMPORTANT SAFETY INSTRUCTIONS
SAFETY WARNINGS
Common symbols and meanings
CLASS3
WIRING
THE TRIANGLE WITH THE LIGHTNING
BOLT IS USED TO ALERT THE USER TO
THE RISK OF ELECTRIC SHOCK.
CLASS3
WIRING
THE TRIANGLE WITH THE EXCLAMATION
POINT IS USED TO ALERT THE USER
TO IMPORTANT OPERATING OR
MAINTENANCE INSTRUCTIONS.
THE CE-MARK INDICATES THE
COMPLIANCE OF THE PRODUCT TO
ALL THE APPLICABLE EUROPEAN
DIRECTIVES
SYMBOL FOR EARTH/GROUND
CONNECTION.
SYMBOL INDICATING THAT THE
EQUIPMENT IS FOR INDOOR USE ONLY.
SYMBOL FOR CONFORMITY WITH
DIRECTIVE 2012/19/EC OF THE
EUROPEAN PARLIAMENT ON WASTE
ELECTRICAL AND ELECTRONIC
EQUIPMENT (WEEE).
+50 OC
0 °C
OPERATING TEMPERATURE RANGE: 0°C TO +50°C - DERATING
ABOVE 35°C.
10%
90%
%STORAGE RELATIVE HUMIDITY RANGE: 10% TO 90% HUMIDITY
(NON CONDENSING).
DO NOT USE THE UNIT AT ALTITUDES ABOVE 2000 M.
DO NOT USE THE UNIT IN TROPICAL ENVIRONMENT.
CLASS3
WIRING
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT ATTEMPT TO
OPEN ANY PART OF THE UNIT. NO USER-SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CLASS3
WIRING
CONNECTION TO THE MAINS SHALL BE DONE ONLY BY A
ELECTROTECHNICAL SKILLED PERSON ACCORDING THE
NATIONAL REQUIREMENTS OF THE COUNTRIES WHERE THE UNIT
IS SOLD.
CLASS3
WIRING
DO NOT USE THIS AMPLIFIER IF THE ELECTRICAL POWER CORD
IS FRAYED OR BROKEN.
CLASS3
WIRING
TO AVOID ELECTRICAL SHOCK, DO NOT TOUCH ANY EXPOSED
SPEAKER WIRING WHILE THE AMPLIFIER IS OPERATING.
CLASS3
WIRING
DO NOT SPILL WATER OR OTHER LIQUIDS INTO OR ON THE
AMPLIFIER.
CLASS3
WIRING
THIS DEVICE MUST BE POWERED EXCLUSIVELY BY EARTH
CONNECTED MAINS SOCKETS IN ELECTRICAL NETWORKS
COMPLIANT TO THE IEC 364 OR SIMILAR RULES
CLASS3
WIRING
DISCONNECT THE AC MAINS SOURCE BEFORE ATTEMPTING TO
CLEAN ANY PART OF THE AMPLIFIER
CLASS3
WIRING
OUTLINE SUGGESTS TO PLUG THE TTM TO A 16 A RATING, C OR D
CURVE, 10 kA SECTIONING BREAKER.
CLASS3
WIRING
OUTPUT TERMINALS ARE HAZARDOUS: WIRING CONNECTION TO
THESE TERMINALS REQUIRES INSTALLATION BY AN INSTRUCTED
PERSON AND THE USE OF READY MADE LEADS.
CLASS3
WIRING
PROPERLY FIT THE AC MAINS PLUG TO THE AMPLIFIER INLET.
BEFORE POWERING THIS AMPLIFIER, VERIFY THAT THE CORRECT
VOLTAGE RATING IS BEING USED.
CLASS3
WIRING
TAKE CARE TO LOCK THE OUTPUT TERMINAL BEFORE SWITCHING
THE DEVICE ON.
CLASS3
WIRING
VERIFY THAT YOUR MAINS CONNECTION IS CAPABLE OF
SATISFYING THE POWER RATINGS OF THE DEVICE.
CLASS3
WIRING
NO NAKED FLAME SOURCES SUCH AS LIGHTED CANDLES
SHOULD BE PLACED ON THE AMPLIFIER.
CLASS3
WIRING
TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY
RACK MOUNTED IN ACCORDANCE WITH THE INSTALLATION
INSTRUCTIONS.
CLASS3
WIRING
THIS EQUIPMENT SHALL BE MOUNTED AT A MAXIMUM HEIGHT
OF 2 M
CLASS3
WIRING
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR
DAMAGES CAUSED TO PERSONS, THINGS OR DATA DUE TO AN
IMPROPER OR MISSING GROUND CONNECTION.
CLASS3
WIRING
IT IS ABSOLUTELY NECESSARY TO VERIFY THESE FUNDAMENTAL
REQUIREMENTS OF SAFETY AND, IN CASE OF DOUBT, REQUIRE
AN ACCURATE CHECK BY QUALIFIED PERSONNEL.

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
5
Please read and keep all safety and use instructions.
This product is intended for installation by
professional installers only! This document is
intended to provide professional installers with basic
installation and safety guidelines for this product in
typical xed-installation systems. Please read this
document and all safety warnings before attempting
installation.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this equipment near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install
in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such
as radiators, heat registers, stoves, or other
apparatus that produce heat.
9. Do not defeat the safety purpose of the polarized
or grounding-type plug. A polarized plug has
two blades with one wider than the other. A
grounding-type plug has two blades and a
third grounding prong. The wide blade or the
third prong are provided for your safety. If
the provided plug does not t into your outlet,
consult an electrician for replacement of the
obsolete outlet.
10. Protect the power cord from being walked on
or pinched particularly at plugs, convenience
receptacles, and the point where they exit from
the apparatus.
11. Only use attachments/accessories specied by
the manufacturer.
12. Use only with the cart,
stand, tripod, bracket,
or table specied by the
manufacturer, or sold
with the apparatus. When
a cart is used, use caution
when moving the cart/
apparatus combination to
avoid injury from tip-over.
13. Unplug this apparatus during lightning storms
or when unused for long periods of time.
14. Refer all servicing to qualied service personnel.
Servicing is required when the apparatus has
been damaged in any way, such as power-supply
cord or plug is damaged, liquid has been spilled
or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped.

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
6
REGULATORY COMPLIANCE STATEMENTS
FCC COMPLIANCE NOTICE
This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and
(2) this device must accept any interference
received, including interference that may cause
undesired operation.
CAUTION: Changes or modications not
expressly approved by the party responsible for
compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and
found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications.
However, there is no guarantee that interference
will not occur in a particular installation. If this
equipment does cause harmful interference to radio
or television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one
or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the
equipment and receiver.
• Connect the equipment into an outlet on
a circuit different from that to which the
receiver is connected.
WARNING: This is a class A product. In a
domestic environment this product may cause
radio interference in which case the user may be
required to take adequate measures.
WEEE DIRECTIVE
If the time arises to dispose of your product,
please recycle all possible component.
This symbol indicates that when the end-
user wishes to discard this product, it must
be sent to separate collection facilities for
recovery and recycling. By separating this
product from other household-type waste,
the volume of waste sent to incinerators or
land-lls will be reduced and natural resources will
thus be conserved.
The Waste Electrical and Electronic Equipment
Directive (WEEE Directive) aims to minimise the
impact of electrical and electronic goods on the
environment. Outline s.r.l. comply with the Directive
2012/19/EU of the European Parliament on waste
electrical and electronic equipment (WEEE) in order
to reduce the amount of WEEE that is being disposed
of in land-ll site. All of our products are marked
with the WEEE symbol; this indicates that this
product must NOT be disposed of with other waste.
Instead it is the user’s responsibility to dispose of
their waste electrical and electronic equipment by
handing it over to an approved reprocessor. For
more information about where you can send your
waste equipment for recycling, please contact your
local distributors.

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
7
EC DECLARATION OF CONFORMITY
We declare that under our sole responsibility the products:
Model Name: TTM 12K4+D, TTM 8K4+D
Intended use: Professional Audio Amplier
Are in conformity with the provisions of the following EC Directives, including all amendments, and with
national legislation implementing these directives:
2014/35/EU Low Voltage Directive
2014/30/EU Electromagnetic Compatibility Directive
2011/65/EU RoHs Directive
The following harmonized standards are applied:
EN 55032:2012,
EN 55032:2012/AC:2013
EN 55035:2017
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61000-3-11:2000
EN 62368-1:2014
EN 62368-1:2014/AC:2015
Flero,
May 2022

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
8
PRELIMINARY OPERATIONS
PACKAGE LIST
After unpacking the unit, check very carefully for
any damage. If any damage is found, please notify
your dealer.
The box contains the following:
•1x TTM Series amplier
•1x Power cord 3x1.5mm2 16A Type F
•1x Power cord 3x1.5mm2 16A Type I
•1x Power cord 16/3 SJT
•1x User Guide
LOCATION
• Install your TTM Series Amplier in well
ventilated rack cabinets at a maximum height of
2 meters above the oor.
• Secure both front and rear brackets to the rack.
• Connect the AC Mains connector to a circuit
breaker.
• Install the amplier far from EMF emitting
devices.
• Avoid placing the amplier close to heat
generating sources.
COOLING
Do not block the ventilation openings and allow
a distance of at least 50 cm from the front and rear
ventilation openings of the amplier.
The TTM Series implements a forced-air
cooling system to maintain constant operating
temperatures. Air enters from the front panel and
exits from the back of the amplier.
The cooling system features variable-speed DC
fans controlled by the heat sink mounted sensors.
This ensures that fan noise and internal dust
accumulation are kept to a minimum.
In the rare case of overheating, the amplier is
protected by limiting the output power to levels that
can be sustained at the actual ambient temperature.
The TTM Series ampliers can be stacked one on
top of the other, but it is recommended to leave one
rack unit empty every three ampliers to guarantee
adequate air ow.
CLEANING
Use a dry cloth for cleaning the chassis and the
front panel. Air lter cleaning should be scheduled
in accordance with the dust levels in the amplier’s
operating environment.
To remove the air lter, detach the front metal
cover by unscrewing the two T20 Torx screws (visual
instructions shown below).
Use compressed air to remove dust from the lter
or wash it with clean water (let it dry thoroughly
before reinstalling).
T20 Torx screw.
3
1
3
1
1 RU
1 RU
1 RU
11
4
2
4
2
2 2
5 5
3
5
3
5
6 6
4
6
4
6
7
2 m max from floor

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
9
AC MAINS SUPPLY
The TTM Series ampliers implement a universal
switching mode power supply, with power factor
correction operating in the range from 100 VAC up to
240 VAC (±10%).
AC mains connection can be found in the rear panel
through the IEC C20 inlet. The approved power cord
is provided.
CONNECTIONS
SIGNAL GROUNDING
There is no ground lift switch or terminal on the
TTM Series amplier. To minimise hum and/or
interference entering the signal path, always use
balanced input connections. For safety, the unit
MUST always operate with the electrical safety earth
connected.
INPUT AND OUTPUT CONNECTIONS
Input connections
• 4x Analog inputs (XLR female)
• 2x Stereo AES3 inputs (XLR female)
• 4x Dante/AES67 inputs (EtherCon)
Output connections
• 4x Amplied outputs (NL4 speakON)
• 4x Analog Link Out connectors (XLR male)
• 2x AES3 Link Out connectors (XLR male)
• 4x Dante/AES67 outputs (EtherCon)
DIGITAL AUDIO CONNECTION
Digital audio is supported via AES3 (AES/EBU) and
Dante™ standard protocols. The AES3 connectors
accept input channel pairs through a single balanced
XLR cable.
The TTM Series ampliers offers two Ethercon
ports supporting a total of 4-in and 4-out Dante/
AES67 channels. Users can congure the amplier
to operate at one of the following three modes: 2-in x
2-out (at 96kHz), 4-in x 4-out (at 48kHz - default), 4-in
x 0-out (at 96kHz). This operation is done under the
amplier Dante settings in ArmoníaPlus.
A computer running the software application
Dante Controller™ can be used to congure the
Dante properties of TTM Series ampliers, which
are automatically discovered and displayed in Dante
Controller™ with the default identier: AMP-XXXXXX,
where ‘XXXXXX’ is the MAC address of the Dante
interface.
LINK OUT CONNECTORS
There are in total six Link Out connectors directly
connected to the amplier’s analogue and AES3
inputs.
The four Link Out connectors linked to inputs 1 to
4 are simple passive THRU connections. The other
two Link Out connectors are fault-tolerant active
repeaters for the AES3 inputs. When the amplier
is on, they actively repeat the AES3 input signal. If
power is lost, an internal relay is switched causing
these connectors to work as simple passive THRU
connections.
BASIC OPERATIONS
SWITCHING THE AMPLIFIER ON
To turn on the amplier, simply connect it to the
mains power with the provided power cord. The time
between power on and passing audio is under 10s for
analogue sources. Time is longer with Dante sources
(about 22 seconds), as the network is rebooted and
patching remade.
Once the device is on, it is possible to manually put
it in standby mode. Further information is detailed
below in a dedicated section called ‘Power Off’.

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
10
LEVEL AND DELAY
The Level and Delay pages allow the control of the
amplier output levels and delay times. Once in one
of the two pages, click on any given output and adjust
the level or delay by turning the rotary encoder.
When an output is selected, the white LED behind the
encoder will light up, indicating that the parameter
can be altered.
Note that it is possible to select multiple outputs
at the same time and simultaneously control their
relative levels and delay. Selected outputs will display
a check mark ✓ next to the speaker preset name.
Clicking the ‘Set Step Size’ button on the top of
the display, allows the selection of the change steps
to be applied when rotating the encoder, if ner
adjustments are necessary. Level change steps can
be set from 1dB (default) to 0.1dB, while delay steps
can be from 10ms to 0.1ms (default is 1ms). For the
delay controls, it is also possible to select between
metric (m) or imperial (ft) systems.
MATRIX
The TTM amplier series has an internal 4 x 4
mixing matrix. The Matrix page shows the internal
matrix outputs and the matrix inputs that are routed
to them. It is possible to change the routing by
clicking on one of the ‘INPUT’ labels and selecting a
new input from the list. These can be any of the four
matrix inputs, or a mix of input channels 1 + 2, or
channels 3 + 4.
Other routing and mixing congurations can be
achieved from ArmoníaPlus. In such cases, the TTM
will display ‘CUSTOM’ in the input label.
SOURCE SELECT
The Source page shows what amplier input
sources are active in each of the 4 internal matrix
inputs. These sources can be any of the 4 amplier
analogue inputs, AES3 or Dante inputs. Manual
selection of different sources, as well as conguration
of an automatic backup selection based on signal
presence, can be achieved from ArmoníaPlus.
SNAPSHOTS
Snapshots are full amplier congurations that
can be saved onboard of the device, and later recalled
when necessary. In the Snapshots page, it is possible
to load up to 50 different amplier congurations
that have been previously saved onboard using
ArmoníaPlus. To load a new snapshot to the amplier,
scroll through the list, select one of the snapshots
available, and click the ‘Load’ button at the bottom of
the screen.
OUT CONFIG
The Out Cong page allows quickly bridging the
amplier’s outputs 1 and 2, and/or outputs 3 and
4. Simply click the ‘Bridge’ button to perform the
operation, and ‘Unbridge’ to revert to the default
conguration.
When n-way loudspeaker presets have been load
to n-speaker channels, a new button labelled ‘Split’
will show up in this page. It is possible to split the
ways for individual conguration and control by
clicking this button.
HOME
The Home page displays the amplier’s output
channels, their level, and the speaker presets
assigned to them. From this page, it is also possible to
mute/unmute the outputs by clicking the respective
loudspeaker icons .
FRONT PANEL CONTROLS
The front panel comprises a multitouch capacitive
display (1), a rotary encoder with pushbutton (3), a
power status LED (4), and a ‘Back/ArmoníaPlus
Callback pushbutton (5). Users can select what
parameters to control and navigate through the
different display options and pages available, by
touching the screen, rotating and pushing the rotary
encoder, or pushing the ‘Back’ button. Control of
some specic parameters, such as output level and
delay, are only possible by rotating the encoder.
From the main menu (2), it is possible to access all
the different pages from where control operations
can be performed.
BACK
OUTLINE TTM 8K4 HOME
1- VEGAS 12 CX >60 dB
2- VEGAS 12 CX >60 dB
3- SPEAK...MODEL >60 dB
4- SPEAK...MODEL >60 dB
1 2 3 4
5

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
11
POWER OFF
From the Power Off page, it is possible to manually
put the amplier in standby mode by clicking the
‘Power OFF’ button. Pushing and holding the rotary
encoder for 4s also triggers the standby mode.
The power status LED (4) is green when the
amplier is ON and becomes red when the amplier
is in standby mode.
Once the amplier is in standby, to turn it back on,
simply touch the screen or push the rotary encoder,
and select ‘Power ON’.
FW UPDATE
Amplier and Dante rmware updates can be
performed via ArmoníaPlus. During the rmware
update, the display will show the message ‘Updating
Firmware’, and a status bar will show the progress
through the various phases.
NETWORKING
The TTM Series amplier supports Dante
networking. The two-gigabit ports are internally
connected via a Gigabit switch to simplify wiring and
eliminate the need for external network switches in
small systems. Control and Dante audio are available
in both ports by default.
This conguration can be checked from the front
panel screen under Node Info >ETH 1/ETH2.
Note: the TTM does not support Dante redundancy,
therefore, do never connect two EtherCon ports to
separate primary and secondary Dante networks
simultaneously.
IP ADDRESSING
The factory default network conguration is
AUTO IP/DHCP.
STATIC IP policy can also be adopted and congured
through ArmoníaPlus or the screen panel (see ‘Net
Cong’ section).
If a DHCP server is not active in the network, the
amplier platform initiates an auto-conguration
with a local numeric network address (of the type
169.254.X.Y and subnet mask 255.255.0.0).
It is recommended to always turn on the DHCP
server before connecting the amplifiers.
NODE INFO
The Node Info page displays general amplier
information, such as its serial number, operating
temperature and mains voltage, rmware versions,
and ethercon ports conguration.
From this page it is also possible to access some
additional amplier settings by clicking the gear
icon. These settings are as follows:
Lock LCD – allows the user to set a password and
subsequently locks the front panel display. When
trying to perform any operation, the user will be
requested to insert the password to unlock the
screen.
Remove Groups – removes the amplier from all
EQ groups that have been previously created using
ArmoníaPlus. Group EQ settings will be lost under
this operation.
Factory Default – sets the amplier to the factory
default settings. Snapshots saved onboard are not
deleted.
LCD Brightness – adjusts the brightness of the front
panel display.
Auto Fade – allows different screen on/off options,
where ‘Always On’ never turns the screen off,
‘Auto Fade’ causes the screen to operate at lower
brightness after 30s of not being used, and ‘Auto Off’
causes the screen to automatically turn off after 30s
of not being used. A simple touch to the screen brings
it back to its normal operation status.
NET CONFIG
The Net Cong page displays the settings for the
amplier control and Dante network congurations.
To scroll between the amplier and Dante settings,
use the arrows ►. Clicking the gear icon , in one
of the two pages, opens the IP congurations, from
where it is possible to set the amplier or the Dante
network to Auto (default) or Static IP, and reset the
network congurations to the default settings.
SPEAKER PRESET
From the Speaker Preset page, it is possible to
load different loudspeaker presets to the amplier’s
outputs. To load a new preset, click the gear icon,
and scroll through the different families, models,
and speaker applications. If the preset has been
successfully loaded to the output channel, its name
will show in the Speaker Preset page.

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
12
OVERALL DIMENSIONS
483 mm
424 mm
391 mm
88 mm
ARMONIAPLUS SYSTEM DESIGN
ArmoníaPlus System Manager is the default
interface that allows setting and customisation of the
TTM Series ampliers. Note that whenever the TTM
is connected to ArmoníaPlus, the front panel display
operations are disabled.
ArmoníaPlus can be installed on a PC running
Windows (XP SP3 and higher).
For a successful connection, both ArmoníaPlus
and the TTM Series must belong to the same subnet.
Download ArmoníaPlus System Manager for free
from the website:
https://www.powersoft.com/en/software/
armoniaplus/

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
13
FRONT PANEL
REAR PANEL
1
2
3
4
Control Panel
Main Menu
Rotary encoder pushbutton
Power status LED
“Back/ArmoníaPlus Callback” pushbutton
1
2
3
4
USB Port
Reserved for servicing purposes
12
14
18
22
2416
20
11
13
17
21
2315
19
10
8
9
7
Output section
CH1 (1+/-) | CH2 (2+/-)
CH2 (1+/-) | N.C. (2+/-)
CH3 (1+/-) | CH4 (2+/-)
CH4 (1+/-) | N.C. (2+/-)
7
8
Input section
Input 1 (XLR-F)
Input 2 (XLR-F)
Input 3 (XLR-F)
Input 4 (XLR-F)
Link Out 1 (XLR-M)
Link Out 2 (XLR-M)
Link Out 3 (XLR-M)
Link Out 4 (XLR-M)
15
16
AC Mains Connector
IEC C19
Network Connectors
ETH 1 (RJ45)
ETH 2 (RJ45)
23
24
9
10
AES3
AES3 In 1-2 (1GND/2+/3-)
AES3 In 3-4 (1GND/2+/3-)
AES3 Link Out 1-2 (1GND/2+/3-)
AES3 Link Out 3-4 (1GND/2+/3-)
11
12
13
14
17
18
19
20
21
22

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
14
PINOUTS
Network Connector RJ45 pinout
12345678
Color code (TIA/EIA-568-B) Pin
ORANGE / WHITE 1
ORANGE 2
GREEN / WHITE 3
BLUE 4
BLUE / WHITE 5
GREEN 6
BROWN / WHITE 7
BROWN 8
12
3
GND
HOT
COLD
GND
HOT
COLD
21
3
Analog/AES3 input XLR-M pinout
Pin# Terminal
1 Ground (GND)
2 Positive (+)
3 Negative (-)
Output NL4 Speakon-F pinout
Single Ended
speakON
connector
output
stage A
output
stage B
CHA +
A
CHB +
B
Bridge-tied load
Two single-ended loads
CHB –
CHA –
A
B
speakON
connector
output
stage A
output
stage B
CHA +
CHB +
CHB –
CHA –
A
B
1+
2+
1–
2–
1+
2+
1–
2–
1+
2+
1–
2–
1+
2+
1–
2–
1+ Speaker A positive terminal
1- Speaker A negative terminal
2+ Speaker B positive terminal
2- Speaker B negative terminal
Analog/AES3 link XLR-F pinout
Pin# Terminal
1 Ground (GND)
2 Positive (+)
3 Negative (-)
Bridged
speakON
connector
output
stage A
output
stage B
CHA +
A
CHB +
B
Bridge-tied load
Two single-ended loads
CHB –
CHA –
A
B
speakON
connector
output
stage A
output
stage B
CHA +
CHB +
CHB –
CHA –
A
B
1+
2+
1–
2–
1+
2+
1–
2–
1+
2+
1–
2–
1+
2+
1–
2–
1+ Speaker positive terminal
2- Speaker negative terminal
Even Channels (CH2 - CH4)
1+ Speaker positive terminal
1- Speaker negative terminal
2+ Not Connected
2- Not Connected
2-
1+
1- 2+

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
15
NOTES

Outline carries out on-going research for product improvement. New materials, manufacturing methods and
design upgrades are introduced to existing products without prior notice as a routine result of this philosophy.
For this reason, any current Outline product may differ in some aspect from its description, but will always
equal or exceed the original design specifications unless otherwise stated.
© Outline 2023
Operating manual product code: Z OMTTMSERIES
Release: 20230331
Printed in Italy
This manual suits for next models
2
Table of contents
Other Outline Amplifier manuals

Outline
Outline PRO 408 MK IV User manual

Outline
Outline NEWTON User manual

Outline
Outline M2800-4 User manual

Outline
Outline GTA series User manual

Outline
Outline M5000-4 User manual

Outline
Outline T4 User manual

Outline
Outline Twin-Pulse Series User manual

Outline
Outline L3000 User manual

Outline
Outline TFive User manual

Outline
Outline L3000E User manual