9
(S) HOW TO SET UP DATA FIELD AS A VARIABLE.
1. If the data field is to be a variable, then the LCD display will show:
DATA LENGTH?(1~34)
A variable field allows the operator to input variable field data while the keyboard is in
the PRINT MODE enter DATA LENGTH(1~34, Dependent upon Font size & Label
width).
Press ENTER to accept your selection.
2. The LCD display will show:
ENTER X SIZE(1-4)
Same procedure as (P). Press ENTER to
accept your selection.
3. The LCD display will show:
ENTER Y SIZE(1-7)
Same procedure as (P). Press ENTER to accept your selection.
4. The LCD display will show:
POSITION OR PRESS D ?
Press “Shift”+“TAB1” Add one space in front of data.
Press “Shift”+“TAB2” Add eight spaces in front of data.
Press “&” This field and next field will be the same line.
Press “Shift”+“INS/L” To insert a field.
Press “Shift”+“DEL/L” To delete this field.
Press Dto step to next screen.
5. The LCD display will show:
POSITION OR PRESS D ?
•••••••
Theboxesdisplayed represent character fieldstoindicate to the operatorthelength(in
characters) of the variable data.
Example: Ifthedata length is5,LCD will show 5blocks.Ifthe data length is 3, LCD will
show 3 blocks. Press ENTER to proceed to next menu.