Oval EL0137 User manual

1
Pulse relay field type totalizer
(Explosionproof)
MODEL:EL0137
Ins. No. E−
126−3-E
Thank you for adopting the pulse relay field type totalizer (hereafter, totalizer).
This instrument is produced and shipped under strict quality management by our company. To use the product
properly, this document explains the precautions required for proper handling. Before using the product, be sure
to read this instruction manual carefully.
Keep this document at hand for future reference.

E-126-3-E
2
CONTENTS
1. PRECAUTIONS ON HANDLING.....................4
1.1 Confirmation of name plate ........................4
1.2 Precautions on transportation.....................5
1.3 Precautions on storage...............................5
1.4 Precautions on use conditions....................5
1.5 Precautions on installation location ............5
1.6 Precautions on
turning ON the power supply......................6
1.7 Note on returning the product.....................6
2. OUTLINE.........................................................6
3. SPECIFICATIONS AND PERFORMANCE .....7
3.1 Standard specifications ..............................7
4. NAME OF EACH PART AND EXTERNAL
DIMENSIONS..................................................8
5. EXTERNAL WIRING GLAND........................11
5.1 Close-up plug ...........................................12
5.2 Replacement of external wiring gland and
close-up plug ............................................12
6. MOUNTING POSTURE.................................13
7. EXTERNAL GROUNDING TERMINAL AND
INTERNAL GROUNDING TERMINAL...........15
8. INTERNAL WIRING CONNECTION .............16
9. OPERATION..................................................17
9.1 Display unit ...............................................17
9.2 Optical switches........................................17
9.2.1 Activate the optical switches...............18
9.2.2 Key lock of optical switches................18
9.2.3 Operation by push button ...................18
9.2.4 Display of reset integration
/ accumulated total or instantaneous
flow rate ..............................................19
9.2.5 Clearance of totalized value ...............19
9.2.6 Display of accumulated total...............19
9.2.7 Instantaneous flow rate bar chart ......20
9.3 Operator alarm .........................................20
9.3.1 Battery level alarm ..............................20
10. PARAMETER SETTING..............................21
10.1 To enter the parameter setting mode......21
10.2 Structure of parameter............................21
10.3 Scroll the parameter ...............................22
10.4 To change or select a value....................23
10.5 To return to the measurement mode ......23
10.6 List of parameters...................................24
10.6.1 Parameter 1. TOTAL.........................25
10.6.2 Parameter 2. RATE...........................25
10.6.3 Parameter 3. DISPL..........................26
10.6.4 Parameter 4. METER .......................26
10.6.5 Parameter 6. OTHERS .....................27
10.7 Procedure for setting parameter.............28
11. MAINTENANCE AND INSPECTION ...........30
11.1 Removal of front lid.................................30
11.2 Install the display unit..............................31
11.3 Installation of front lid..............................31
11.4 Replacement of battery...........................32
11.5 How to discard the battery ......................34
11.6 Test and adjustment of EL0137 ..............34
11.7 Precautions on
turning ON the power supply..................34
11.8 Error code ...............................................35
12. EXPLOSIONPROOF STRUCTURE............35
13. PRODUCT CODE EXPLANATION .............36

E-126-3-E
3
A lithium battery is mounted on EL0137.
To use the product safely, please observe the following warnings and cautions.
CAUTION:
WARNING:
This manual uses the precaution words
"NOTE", "CAUTION", and "WARNING" as explained below:
NOTE:
Notes are separated from the general text to bring the user's
attention to important information.
CAUTION:
Caution statements inform the user of hazards or unsafe practices
which could result in minor personal injury or product/property
damage.
WARNING:
Warning statements inform the user of hazards or unsafe practices
which could result in severe personal injury or death.
Do not use the battery for any purpose other than designated use application.
Do not charge the battery.
Do not throw the battery in the re or heat it up or disassemble it.
Do not reverse positive and negative sides of battery when you use it.
Do not short-circuit the battery.
Keep the battery out of infant's reach.
If liquid leaks from battery or abnormal odor is generated, the leaked electrolysis solution may catch fire.
Keep the battery away from the re immediately.
Do not solder the battery directly.
Do not apply strong impact to the battery or throw it.
Do not deform the battery.
Do not discharge the battery forcibly.
Do not peel off the lm on the surface of battery or damage it.
If the solution of battery gets into your eye, wash the eye with clean water such as tap water sufciently and
receive medical treatment from a doctor immediately.
Do not use or leave the battery at a place where is exposed to direct sunlight or hot place such as inside of
vehicle under the boiling sun.
Do not wet the battery with water or other liquid.
Specifications and performance of battery may not be suitable depending on usage or instrument. Read
instruction manual and precautions of instrument carefully before using it.
Store the battery avoiding direct sunlight, high temperature, and high humidity.
When you discard or store the battery, insulate it completely with tape etc.
When you discard the battery, follow the rule shown in the ordinance etc. of autonomous body.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●

Explosionproof
cautionlabel
Product
label
E-126-3-E
1. PRECAUTIONS ON HANDLING
At the time of delivery, the power of this instrument is turned OFF. Before the initial operation, open
the front lid and turn the power ON. For information on power-on procedure, refer to Section 8.
This instrument is shipped after sufficient inspection at factory. After you receive the instrument, check the
external appearance and check the instrument is not damaged by an accident during the transportation.
This section describes the precautions required for handling. Please read this section first.
If you have any inquiries, please contact the distributor
or your nearest service network of our company.
1.1 Confirmation of name plate
Each unit of this flowmeter is adjusted according to the specifications. Product model and rated specifications are
described on the product name plate affixed to the side surface of main unit. Please check it reads the ordered
specifications.
Fig. 1.3 Product name plate
◆Note ◆
When you contact our company, please inform us of product name, product
model, and production number etc.
Fig. 1.2 Explosionproof caution name plate
Fig. 1.1 Confirmation of labels
製造者名称:株式会社オーバル 横浜事業所
型式の名称:EL0137-1
防爆の型式:ExdⅡCT6X
定格
電源 :DC3.6V
周囲温度:−20℃〜+55℃
出力回路
オープンコレクタパルス出力
電圧パルス
電流パルス
接点
−警告事項−
爆発性雰囲気の存在する恐れがある時は蓋を開けないこと。
−注意事項−
本機器をご使用する前は、取扱説明書を参照下さい。
労(平. )検
第 TC21476 号
株式会社
オーバル

E-126-3-E
-Place where is not exposed to rain or water
-Place where vibration or shock is rarely generated
-Room-temperature and room-humidity place
-Storage / shipment environment condition
Temperature: 20 ±15℃
Relative humidity: 65 ±20%
Atmosphere pressure: 500 to 1060hPa
This instrument has IP67 class performance,
however, when it is used at a place exposed to direct
sunlight or change of weather constantly, enclose it
with shielding object such as roof to protect the
instrument during use.
Do not install the product at a place where thumping
vibration is generated, and install it on stable
structure without effects of vibration.
Fig. 1.4 Precautions on installation location
1.2 Precautions on transportation
(1) To prevent the instrument from being damaged by an accident during transportation, convey this instrument
to the installation location in the original packing style shipped from our company whenever possible.
(2) Take care not to apply strong shock to the instrument or get it wet with rain during the conveyance.
1.3 Precautions on storage
After receiving this instrument, an unexpected accident may occur if the elapsed time before installation is long.
If the long-term storage is expected, pay attention to the following items.
(1) Store this instrument in the original packing style shipped from our company whenever possible.
(2) The storage place should meet the conditions shown below.
1.4 Precautions on use conditions
To keep accuracy of totalizer and long-term durability, it is necessary to use the product under the designated
conditions of ambient temperature and rated power (signal) etc. These use conditions are shown in the section
"3. Specifications / performance". Please be sure to check it before the operation.
If you want to change the use conditions, please contact us.
1.5 Precautions on installation location
The ambient operating temperature of totalizer is -20°C to +55°C (in case of non-explosionproof type, -40°C to
+70°C). If the totalizer may be exposed to high temperature due to direct sunlight and reflected heat etc., set up
sunshade etc. and use the product within the use temperature range. Do not put an object within 10cm from front
surface of product (glossy object causes wrong reaction of optical switches and may affect the life duration of
battery).

E-126-3-E
6
1.6 Precautions on turning ON the power supply
When operated in a hazardous area, make sure there is no explosive gas in the place so as to ensure the safety.
1.7 Note on returning the product
When you request the repair by returning the product for any reasons, follow the items shown below.
(1) Make a document of information of returned instrument such as "model code, serial number, reason of return
and all relevant information of the address to return the product" and include it with the product.
(2) Package the instrument carefully. Use the original packing box if possible.
2. OUTLINE
By relaying pulse signal from oval gear flowmeter, DELTA or EX-TUBINE Flowmeter, this totalizer displays
cumulative total flow, instantaneous flow rate, etc. The display is easily viewable with the backlit, enabling highly
reliable flow measurement in the field.
Also, switching of the display and parameters is possible with optical switches on the front face easily and
flexibly.

E-126-3-E
Item Description
Installation method Attached to 2B (50A) pipe, equipped with a dedicated clamp
Directive and
standard
EMC EN 61326-1
RoHS EN 50581
Explosionproof
construction Exd ⅡC T6X
Waterproof
construction IP66/67 (※1)
Ambient temperature Explosionproof product: -20 to +55°C, non-explosionproof product: -40 to +70°C
Ambient humidity 5 to 100% RH no dew condensation in enclosure
Material of main unit Die-cast aluminum
Coating of case Polyurethane coating
Coating color Main unit: Munsell 10B8/4 , lid (front and rear): Munsell 2.5PB4/10
Response frequency 200Hz max. (input dividing: up to 3kHz supported by setting 1/10, 1/100)
Display
Height of character: upper row 10.5mm, lower row 7mm, display changes alternately by
optical switches
(1) 8-digit resettable total display (integral part max. 7 digits + decimal number)
(2) 8-digit accumulated total display
(3) Instantaneous flow rate display (selected from /day, /h, /min, /sec)
(4) Instantaneous flow rate bar chart display
Warning display of remaining battery ( ), switch operation display ( ), alarm display, key
lock display ( ), equipped with backlight
Input
Compensated
pulse or
uncompensated
pulse
Contact or open collector pulse
Input resistance: 10Ω, reception level: Hi≥0.5mA, Lo≤0.01mA
Voltage pulse
Input resistance: 5.1kΩ, reception level: Hi≥3.0V, Lo≤1.5V
Current pulse (4-20mA)
Input resistance: 91Ω, reception level: Hi≥15mA, Lo≤7mA
Special specification rating: V+≤35.2V*
* Product code J (open collector pulse dedicated to Thermister Type DELTA)
Electric conduit
M25 pressure tight packing (applicable cable diameter: φ8.1 to 13.0mm) : Draw out the wire
from the downside of front (central part)
Diameter of close-up plug socket: 12.0mm (※2) (The plugs on both sides are explosionproof
parts. Do not use them being disconnected as a general rule.)
Maximum
transmission distance 1km (relayed by line between receiver-transmitter)
Power supply
Exclusive battery (※3)
Life duration: approx. 4 years (8 h/day operated, 30 min/day backlight lighting)
The battery's life length depends on setting, configuration, and use environment etc.
Data protection
All settings are saved in EEPROM. Accumulated total is backed up every minute. Data is
saved for 10 years or more.
Parameter setting can be protected by password.
Weight Approx. 1.9kg (pressure tight packing 0.1kg is not included)
3. SPECIFICATIONS AND PERFORMANCE
3.1 Standard specifications
NOTE: ※1. The electric electric conduit of the shipped product is protected with IP43 equivalent close-up
plug.
If the product is stored for a long time, observe the "precautions on storage" shown in section 1.3.
※2. 12mm is not included with the general wrench set.
※3. Please contact us about replacing the battery.

E-126-3-E
Fig. 4.1 Names of external parts
Fig. 4.2 Names of internal parts
Close-upplug(※1)
Frontlid
Explosionproofcautionlabel
Approvallabel
Externalwiringlead-inclasp(※2)
Groundingterminal
Totalizermainunit
4. NAME OF EACH PART AND EXTERNAL DIMENSIONS
The names of parts configuring this totalizer are shown below.
NOTE: ※1. This close-up plug is an explosionproof part. Do not use it being disconnected.
These two parts cannot be used for leading-in the external wiring.
※2. The wiring is drawn from this point.
(3)Baseprotectiveshield
(8)Batteryholderunit
(2)Displayunit
(1)Frontlid
(4)M3screwx3
(7)M3supportrod
(10)Mainunit
(9)Batteryboard
(6)M3supportrod
(5)PulseconversionboardM3

E-126-3-E
Please contact OVAL to purchase the replacement of
dedicated battery.
Damages caused by using a battery which is NOT
purchased from OVAL will not be covered by the
warranty.
Fig. 4.3 Display unit
WARNING:
Do not fail to ensure there is no
explosive gas around the area
before start disassembling.
(11)Connectorofdisplayunit
(11)Connectorofpowersupply

E-126-3-E
10
Fig. 4.5 External dimensions diagram (only main unit)
Fig. 4.6 External dimensions diagram (cable gland designated by OVAL is connected)
115
112
148
3
45
133
118
72
1
3
2
67
4
5
Name
LCDdisplaypart
Opticalswitches
GroundingterminalM4screw
M25pressuretightpacking
Metalclamp
Modelcodeplate
Explosionproofcautionlabel
(oppositesurface)
No.
1
2
3
4
5
6
7
115
112
148
3
45
133
118
72
1
3
2
67
4
5
Name
LCDdisplaypart
Opticalswitches
GroundingterminalM4screw
M25pressuretightpacking
Metalclamp
Modelcodeplate
Explosionproofcautionlabel
(oppositesurface)
No.
1
2
3
4
5
6
7
The external dimensions are shown below. The dimension values vary depending on the "external wiring gland"
to be connected and the combination of "close-up plug".

E-126-3-E
11
Fig. 4.7 Dimensions of metal clamp
100mm(3.94")
103mm(4.06")
25mm(0.98")
70(2.76")
115mm(4.53")
118mm(4.65")
7mm(0.28")
10(0.39")
72
42
58
22
M5x0.8
680.1
63
17
R5
14
14
24
UP45R1 .5
UP45R1 .5
1.50
21.8
56.2
Flatpattern
Bendedmodel
Mounting kit 1 Mounting kit 2
5. EXTERNAL WIRING GLAND
In case of TIIS explosionproof type
(1) This totalizer when used as a flameproof instrument uses the cable gland (pressure-tight packing) method of
IEC harmonized standards for the external wirings. Do not use cable glands other than the provided together
with the instrument. The rubber packing is provided with the product according to the finished external
diameter of cable as shown in the table below. Select and assemble the rubber packing which matches with
the external diameter of your cable.
External dimension of applicable cable
Nominal code of
packing
Internal diameter of
packing
External diameter of
cable Applicable torque Pressure tight packing
model code
9φ9 φ8.1 to φ9.0 18.5N・mKXB-25, 22 ORES
10 φ10 φ9.1 to φ10.0 22.0N・m
11 φ11 φ10.1 to φ11.0 25.8N・m
KXB-25, 22 ORE12 φ12 φ11.1 to φ12.0 30.0N・m
13 φ13 φ12.1 to φ13.0 33.5N・m
NOTE: "Applicable torque" is applied to the gland shown in the assembly diagram below.

E-126-3-E
12
Union coupling
G3/4
Rubber packing
Screw M4
M25
Clamp
Gland
Fig. 5.1 External wiring gland assembly diagram
◆Precautions on external wiring gland (pressure tight packing) ◆
For both of non-explosionproof type and explosionproof type, take the following into consideration.
1. The pressure-tight packing must fit the finished cable external diameter.
2. Securely tighten the pressure-tight packing so that there is no gap between the packing and the
cable.
3. If not using a pressure-tight packing, make sure to take necessary measures to prevent moisture and
dust from entering.
CAUTION: 1. After the cable is passed through the rubber packing, crush the screwed
packing of gland. At this time, screw the gland until the cable stop slipping.
2. This cable gland is a cable grand with anchor function. After the step(1), be
sure to screw the clamp with screw: M4 and fix the cable surely.
5.1 Close-up plug
When the close-up plug is used for TIIS explosionproof type, be sure to use the close-up plug designated by us.
Under the environment where dust and water immersion are concerned, use the plug designated by us to satisfy
the IP class of the product. (This instrument is shipped with the close-up plug sufficiently secured to ensure the
airtightness.)
5.2 Replacement of external wiring gland and close-up plug
External wiring gland and close-up plug are designated by us. If they need to be repaired or replaced, the
replacement parts can be procured from OVAL's agent in your area or OVAL service department. When you
order the parts, please inform us of flowmeter model, part name, and quantity.

E-126-3-E
13
Fig. 6.1 Usable mounting posture
LCD of display unit should not face vertex direction (directly above,
directly underneath) when mounted
6. MOUNTING POSTURE
When you install this instrument, carry out the operation in the mounting posture shown below.
CAUTION: 1. The electrostatic discharge may cause fatal damage of electronic instrument.
Remove static electricity sufficiently before installing the equipment or opening
the lid.
2. For the external grounding terminal of EL0137 (refer to Fig.7.1), carry out
class D grounding work and connect the shielded wire following Fig.8.2.
NOTE:
・
The display unit in the enclosure can be changed to four directions.
・
The enclosure itself can be installed in any of four directions, i.e. 0°, 90°, 180°, 270°.

E-126-3-E
1
Fig. 6.2 Mounting - bracket
Fig. 6.3 Mounting - pipe mounting
Mounted on pipe using a bracket
Maximum torque: 4N・m

E-126-3-E
1
Internalgroundingterminal
Externalgroundingterminal
Screwsize:M4
Connectablediameter
ofconductor:4mmorbigger
Internalgroundingterminal
Screwsize:M4
Connectablediameter
ofconductor:4mmorbigger
Externalgroundingterminal
Fig. 7.1 Grounding terminal
7. EXTERNAL GROUNDING TERMINAL AND INTERNAL GROUNDING TERMINAL
This product has "external grounding terminal" and "internal grounding terminal". When you use this product,
please carry out "class D grounding work".
NOTE: For the internal grounding terminal, use round crimping terminal.

E-126-3-E
16
SIG.R 0V SIG.G
V+
TerminalforconvertingOCtovoltagepulse
V+≦35.2V
(cannotbeusedforotherthanproductcode"J")
PWR
Batteryboardandswitches
8. INTERNAL WIRING CONNECTION
Connect an external wiring to internal terminal of this instrument as shown below.
<Procedure>
(1) Remove the front lid.
(2) Remove the display unit.
(3) Connect the external wiring to the
internal terminal as shown below.
WARNING: Do not fail to ensure there is no
explosive gas around the area
before start wiring.
Fig. 8.1 Internal wiring connection
ConnectedtoFGonlywhentheshieldedgrounding
isnotimplementedontransmitterand
receiversides
3-coreor
4-coreshieldedcable
Connectedonlyforparticular
specifications(productcode:J)
*Donotconnecttotransmitter
sideof[+V]
3-wire
type
3-wire
type 2-wire
type
2-wire
type
+V
SIG
0V
+V
SIG
0V
Receiverside Transmitter(flowmeter)sideJointbox
Connectedtoshieldedgroundingproperlyaccordingtothespecificationsoftransmitterandreceiver
[Thisinstrument]
Pulserelaytypefield
typetotalizer
EL0137
FG
V+
SIG.R
0V
SIG.G
Fig. 8.2 Diagram of wiring to external
NOTE: Joint box, cable, receiver, and oscillator are not provided together with this product.

E-126-3-E
1
Totalunit
Instantaneousflowrate/Accumulatedtotal(switchedbySELECTbutton)
Totaldisplaymark
(ACC.isnotused)
Instantaneousflowrate
displaymark
Instantaneousflowratebarchart
Batterylevelalarm
Resettabletotal
Alarmmark
Switchoperationrecognitionmark
Statemarkofsetup
Unitofinputpulsetodisplayunit
Usualmeasurement,changeofparameter
Keylockmark
Fig.9.1 Display unit
9.2 Optical switches
The optical switches can be operated through the glass. The following keys are usable.
The optical keys are designed to enable stable operation and never respond to the taint on the surface of glass,
however, if a wrong reaction of optical switches is generated, the life duration of battery may shorten. (※) Keep
the surface of glass clean all the time so as not to cause wrong reaction of optical switches. Do not put an object
within 10cm from front surface of product (glossy object causes wrong reaction of optical switches).
Fig. 9.2 Optical switches
Function of key
This key is used for shifting to the parameter confirmation mode.
In the parameter confirmation mode, this key is used for moving the transition table to left side
or setting or saving the changed value. * For the transition table of parameter confirmation
mode, refer to section 10.2.
This key is used for selecting cumulative total display / instantaneous flow rate display. In the
parameter confirmation mode, the arrow (▲) is operated and used for moving the transition
table downward or increasing the value.
This key is used for clearing the value of resettable total. To clear the total value, push the key
twice.
In the parameter confirmation mode, the arrow (▶) is operated and used for moving the
transition table to right side or shifting the digit of value.
PROG
SELECT
CLEAR
PROG SELECT CLEAR
9. OPERATION
When you operate EL0137, understand the content of this instruction manual sufficiently.
9.1 Display unit
The optical switches may not react properly
depending on environmental conditions.
If working poorly, try again using a reflective
material, such as a sheet of white paper.
※

E-126-3-E
1
9.2.1 Activate the optical switches
To reset the key lock mark " " of optical switches, carry out the procedure shown below.
If an optical switch undergoes reaction, " " mark will be displayed, and if the operation is normally executed,
the key lock mark " " will disappear.
(1) Push switch long.
(2) If PUSH SEL is displayed, push switch long.
(3) If PUSH CLr is displayed, push switch long.
(4) The key lock " " display disappears and the key is unlocked.
If "PUSH PrG" is displayed during the operation shown above, an operation error is generated. Carry out the
operation from step (1) again.
If nothing is operated after the key is unlocked, the status will automatically return to key lock status in 30
seconds.
When the key is locked, the key lock mark " " is displayed in the upper part of the display.
9.2.2 Key lock of optical switches
If you touch the optical switches and at the same time for three seconds or wait for 30 seconds,
the key will be locked. If the key is locked, the key lock mark will be displayed in the upper part of the display as
shown below.
Fig. 9.3 Indication of key lock mark
9.2.3 Operation by push button
If the front lid is removed, three mechanical push buttons are allocated under three optical switches in the same
order as optical switches. To prevent malfunction, check the key lock of optical switches is activated before
removing the front lid.
These keys operate in a same way as optical switches.
Fig. 9.4 Operation of push button
PROG
CLEAR
PROG SELECT CLEAR
Prog
Select
Clear
PROG
SELECT
CLEAR

E-126-3-E
1
9.2.6 Display of accumulated total
When is pressed, Resettable Cumulative Flow remains displayed in the upper part and Total Cumulative
Flow is displayed in the lower part. Total Cumulative Flow is non-resettable. This instrument has an 8-digit
display and can count up to 99 999 999. The position of decimal point depends on parameter [1.2 dECS].
After 20 seconds of pressing the select button, the display goes back to showing Resettable Cumulative Flow
(upper part) and Instantaneous Flow (lower part).
NOTE: When Resettable Cumulative Flow shows a digit(s) after decimal point, the cumulated is a seven-digit
figure.
9.2.5 Clearance of totalized value
If you push twice, the reset total value can be cleared.
If you push once, "PUSH CLEAR" will flash. To avoid malfunction, press any key other than
at this time. Or, the clear operation will be cancelled in 20 seconds and the display returns to the usual
display without affecting the totalized value. If you want to complete the clear operation, press once
again within 20 seconds.
9.2.4 Display of reset total / accumulated total or instantaneous flow rate
This is the usual display of EL0137 (measurement mode). Even in the parameter confirmation mode, the display
automatically returns to this usual display if a constant time elapses. The reset total value is displayed on the
upper field of display and the instantaneous flow rate is displayed at the lower field. If "-------" is displayed for the
instantaneous flow rate display, the digit of instantaneous flow rate is too large. Recheck the parameter is proper
(refer to "10. Parameter setting").
To read the accumulated integration, push key to shift to the display of lower field.
EL0137 usually displays the measurement mode. The settings for flowrate displayed in the measurement mode
can be changed by parameter confirmation mode (e.g. meter factor, decimal point position.) The signal input
from flowmeter is detected in EL0137 to display the flow rate. The displayed value is updated according to the
update cycle of the selected display. After the key operation, the displayed value is updated eight times every
second and the value will return to the setting value selected by parameter confirmation mode (3.1: update cycle)
in about 60 seconds.
Fig. 9.5 Example of displayed information during operation
In the measurement mode, the following functions are usable.
SELECT
CLEAR
CLEAR
CLEAR
CLEAR
SELECT

E-126-3-E
20
9.3 Operator alarm
9.3.1 Battery level alarm
If the remaining battery level descends, the battery level alarm will light up. If battery level alarm lights up,
replace the battery with a new one as soon as possible.
Fig. 9.6 Example of display during measurement
Fig. 9.7 Example of battery level alarm
9.2.7 Instantaneous flow rate bar chart display
The full scale flow rate setting value (3.3: SPAn of 10.6.3) is 100%, and this is displayed as the flow rate divided
into 10, which is interlocked with the instantaneous flow rate. This function can enable or disable the display by
selecting the instantaneous flow rate bar chart (3.2: GrAPH of 10.6.3).
WARNING: Please ask us about replacing batteries. Please note that we do not take any
liability for any problem caused by batteries purchased through an entity
other than us.
Table of contents
Other Oval Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

Vahle
Vahle KBHF troubleshooting guide

PCB Piezotronics
PCB Piezotronics 1631-06C Installation and operating manual

Siemens
Siemens SIMATIC ET 200eco PN System manual

BOWMAN
BOWMAN SUPERMATCH SPORTING DOUBLE instructions

DANA
DANA DT Series Assembly instructions

SCHUNK
SCHUNK VERO-S NSR3 138 Assembly and operating manual