8
• Connect the L (live) and N (neutral) terminals on the Heat Recevirer to the
L and
N circuit on the boiler or junction box to power the Heat Recevirer.
Connect the heating control circuit to the Heat Recevier 4 (normally open),
5 (common), 6 (normally closed) as needed.
• If your system has a hot water control circuit, connect it to 1 (normally
closed), 2 (common), 3 (normally open) as needed.
Terminal designation:
Terminals What it means
L Live wire
NNeutral wires
1Hot water relay normally closed, (3A resistive,1A inductive)
2Hot water relay common, (3A resistive,1A inductive)
3Hot water relay normally open, (3A resistive,1A inductive)
4Heating relay normally open, (3A resistive,1A inductive)
5Heating relay common, (3A resistive,1A inductive)
6Heating relay normally closed, (3A resistive,1A inductive)
Hot water LED indicator
Heating LED indicator
Step 3. Connect the wires
Connect the wires correspondingly from the boiler or junction box to the
Heat Receiver according to your heating system:
502-Receiver
654
N
L 1 2 3