Oxford PRECISION BS-60E User manual

Electronic Bench Scales
OXFORD
PRECISION
OXD-844-5010K/OXD-844-5030K
INSTRUCTION MANUAL
• Battery or mains powered
(batteries provided)
• Suitable for warehouse or light
industrial applications
• Wall or desk mounted display
• Dual reading – metric or imperial
• Capacities:
Model: BS-60E 60kg/132.28lb
Model: BS-120E 120kg/264.56lb
• RS232 Interface
Diagrammatic information
Adjustable
feet
Load
cell
Overload
protection
screws
Battery
compartment/
cover
4 x AA
batteries
Fig 1. Underside view of the scales
Fig 2. Display unit mounting options and views
OXFORD PRECISION Victoria Works, Leicester, England
© The Kennedy Group Ltd. 08/04
OXD-844-5010-5030K_Instructions.qxd 05/08/2008 14:19 Page 1
Battery and AC Adaptor
1. Specifications
2. How To Programme The Auto-Off Time
3. Weighing Operation
Please read this manual before use.
Oxford Electronic Bench Scales are designed to run on AC power (AC adaptor included) or
4 x AA batteries (supplied). The batteries should be installed in the battery compartment,
which is located on the underside of the base unit.
The AC adaptor allows the scales to be operated via 240V mains electricity supply, and
connects to the scales via the adaptor housing to the rear of the electronic display unit.
To install batteries, remove the battery cover on the underside of the base unit and insert
the 4 x AA batteries, making sure that you have the correct polarity, as indicated on the
base unit battery housing. Reposition the battery housing cover and reinsert the screws to
secure.
Note: Only use the scales on a flat and stable surface. Make sure that the chosen surface is
sturdy enough to support the weight of the scales and the items to be weighed. The height
of the base unit can be adjusted by turning the feet in an anti-clockwise direction to raise
and a clockwise direction to lower the base unit.
Model Capacity Graduation
BS-60E 60kg/132.28lb 0.02kg/0.05lb
BS-120E 120kg/264.56lb 0.05kg/0.1lb
(a) With the power OFF, press and hold the PRINT key, and press the ON/OFF key until the
indicator displays “A.OFF.X” (X=0,1,2,3,4,5,6,7,8,9 minutes), the display value “X” is
the auto-off time. When the display is “0” auto-off is disabled.
(b) To change the auto-off time, press the UNIT key which will increase the X value by 1.
Press the TARE key to confirm the auto-off time.
(c) To exit the auto-off time programme, press ON/OFF, which will reset the diplay.
The factory setting is X=0.
When the ON/OFF key is pressed the display will initially be shown as 60.00kg
(OXD-844-6010K) or 120.00kg (OXD-844-5030K), when the scale resets itself to 0.00 the
scale is ready for use and the following operations are enabled:
(a) To change the unit of measurement on the display, press the UNIT key. This toggles the
display between kg and lb.
(b) If an item is to be weighed in a container, the weight of the container can be subtracted
by placing it on the scales and resetting the zero point. The maximum weight at which
the zero point can be reset is 25% of the total capacity. This operation is activated by
pressing the ON/OFF key for 2 seconds. If the ON/OFF key is depressed for a greater
length of time, the scales will be turned off.
4. Advanced Operating Instructions
Calibration
(c) Press the TARE key to tare or zero the scale after the scales have been used in the
manner described in Section 3(b).
(d) When the scales are connected to a computer via the RS232 interface, data can be
transferred through the RS232 port. To transmit data in this manner press the PRINT
key. Data will be transmitted through the RS232 port.
Please note: The combined tare and net weight must not exceed the capacity of the
scales.
Display messages are generated in certain circumstances and should be interpreted as
follows:
(i) 60.00/120.00 The scales capacity is 60kg or 120kg and has not yet set itself to
its stable zero point.
(ii) 0The zero setting is too high.
(iii) A.OFF.X Indicates auto-off time.
(iv) CAL-0 Calibration zero indicator.
(v) CAL-F Calibration full capacity indicator.
(vi) CAL..Er Calibration error.
(vii) Ach.Er Analogue channel error.
(viii) EEP.Er Read/Write error.
(ix) _______ The weight exceeds maximum capacity (60.18kg/120.45kg)
(x) _______ The input signal is too small.
(xi) Lo Low voltage.
Protocols
When scale’s “P” is pressed or the carriage return (0d hex) is received, PS-103 scale will
transmit weight, unit, stability, over/down or low voltage message according to the following
protocol:
Baud rate : 9600bps
Start bit : 1 bit
Data bits : 8 bits
Stop bit : 1 bit
Parity : none
The calibration of this product requires specialist tools and should only be carried out by
persons with appropriate skills/qualifications. Should you experience any problems please
return the goods to your supplier, who will arrange professional calibration of the scales.
UNDER NO CIRCUMSTANCES SHOULD MAINTENANCE OR CALIBRATION BE ATTEMPTED
BY PERSONS WITHOUT APPROPRIATE SKILLS OR QUALIFICATIONS. SUCH ACTIONS MAY
RESULT IN IRREPAIRABLE DAMAGE AND WILL ALSO INVALIDATE ANY GUARANTEE OR
WARRANTY.
OXD-844-5010-5030K_Instructions.qxd 05/08/2008 14:19 Page 2

This manual suits for next models

1

Other Oxford PRECISION Scale manuals

Oxford PRECISION OXD-844-2040K User manual

Oxford PRECISION

Oxford PRECISION OXD-844-2040K User manual

Oxford PRECISION WS-6E User manual

Oxford PRECISION

Oxford PRECISION WS-6E User manual

Oxford PRECISION OXD-844-2840K User manual

Oxford PRECISION

Oxford PRECISION OXD-844-2840K User manual

Popular Scale manuals by other brands

Rossmax WF260 quick guide

Rossmax

Rossmax WF260 quick guide

Adam Equipment AZextra 3 manual

Adam Equipment

Adam Equipment AZextra 3 manual

Vetek VRH-300 user manual

Vetek

Vetek VRH-300 user manual

Parata Systems AccuCount II user guide

Parata Systems

Parata Systems AccuCount II user guide

Dymo M5 user guide

Dymo

Dymo M5 user guide

RUSTA 559512360201 manual

RUSTA

RUSTA 559512360201 manual

Tanita InnerScan BC-542 instruction manual

Tanita

Tanita InnerScan BC-542 instruction manual

Dymo M3 user guide

Dymo

Dymo M3 user guide

Precisa 320 XB operating instructions

Precisa

Precisa 320 XB operating instructions

Terraillon Body Fit One manual

Terraillon

Terraillon Body Fit One manual

Cardinal Detecto Operation instructions

Cardinal

Cardinal Detecto Operation instructions

Perin WeighMaster 1500 User handbook

Perin WeighMaster

Perin WeighMaster 1500 User handbook

KERN PLJ-N operating manual

KERN

KERN PLJ-N operating manual

Seca 767 Instruction manual and guarantee

Seca

Seca 767 Instruction manual and guarantee

Vogue FS488 instruction manual

Vogue

Vogue FS488 instruction manual

G3 Ferrari G20038 user manual

G3 Ferrari

G3 Ferrari G20038 user manual

Hardy Process Solutions BSX Series Installation & operation manual

Hardy Process Solutions

Hardy Process Solutions BSX Series Installation & operation manual

Biocomfort BSC105 operating instructions

Biocomfort

Biocomfort BSC105 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.