5.AC Voltage detection: Place the detector
tip of the Voltage Detector near an AC
voltage. If the Voltage Detector detects
voltage within the dened detection
range, the green LED will turn off, the red
LED will turn on, and the beeper will beep
rapidly.
6.Low Battery Indication: Replace the
batteries if the green LED does not turn
on. When the Voltage Detector is on
and the batteries are too low for reliable
operation, the beeper will beep three
times and the green LED will turn off
indicating the Voltage Detector is not
operational. Replace the batteries to
restore operation.
7. Auto Power Off: To conserve battery life,
the Voltage Detector will automatically
turn off after approximately 5 minutes
of inactivity. When powering down, the
beeper will beep twice and the green LED
will turn off.
NOTE: If you press and hold the
button more 5 seconds, the Voltage
Detector regards this as error and it will
beep twice and then turn o.
CHANGING BATTERIES
1. Gently push down on locking tab.
2.While pushing down on tab,
slide cap off body.
3. Insert batteries positive ends rst
4. Align locking tab with cap.
5. Slide cap onto Voltage Detector body.
OPERATION
1. Turning the Voltage Detector On:
Momentarily press the ON/OFF
button. The beeper will beep once and
the green LED will illuminate to indicate
that the Voltage Detector is on and ready
for use.
2.Turning the Voltage Detector Off:
Momentarily press the ON/OFF button.
The Voltage Detector will beep twice and
the green LED will turn off.
3.Turning the Beeper Off: Disable the
beeper by holding the ON/OFF
button down for more than two seconds
during power up. To enable the beeper
again, turn the Voltage Detector off and
then turn it on.
4.Verify Operation: Before using the
Voltage Detector, (1) Make sure the
green LED is glowing, (2) Check Voltage
Detector on a known live AC voltage that
is within the dened detection range of
the Voltage Detector.
OXFORD PRECISION
P.O. Box 14, Wigston, Leicester,
England, LE18 1AT.
THE ENVIRONMENT
DECLARATION OF CONFORMITY
We hereby certify that the OXFORD NON-CONTACT AC
VOLTAGE DETECTOR (ORDER CODE: OXD-516-1336M)
complies with all the relevant provisions of the
EMC Electromagnetic Compatibility Directive 2014/30/EU
Standards Applied: EN61326-1:2013, EN61326-2-1:2013,
IEC61326-1:2012, IEC61326-2-1:2012
LVD Low Voltage Directive 2014/35/EU
Standards Applied: EN61010-1:2010, EN61010-2-033:2012
RoHS2 Restriction of Hazardous Substances Directive 2011/65/EU
Position: Compliance Director
Date: September 2019
Always dispose of unwanted tools, accessories and packaging
materials in an environmentally friendly manner.
In observance of European Directive on Waste Electrical
and Electronic Equipment (WEEE) and its implementation
in accordance with national law, electrical goods that have
reached the end of their life must be collected separately and
returned to an environmentally compatible recycling facility.
Do not dispose of electrical goods with domestic waste
materials as inappropriate disposal may cause potential
hazards to the environment and human health.
For further information, please contact your local authority
or the retailer from whom you purchased the product.
QUALITY GUARANTEE & WARRANTY
OXFORD PRECISION products carry a one year manufacturer’s warranty.
OXFORD PRECISION products are designed & manufactured
to the highest standards & specications.
Assuring the quality and performance required by all sectors of industry.
OXFORD PRECISION products are fully guaranteed
against faulty materials & workmanship.
Should they be found to be defective, they will either be repaired or
replaced free of charge (fair wear and tear and/or misuse excepted).
Please retain supplier invoice as proof of purchase.
SAFETY INFORMATION
• Read, understand and follow Safety Rules and
Operating Instructions in the manual before
using this Voltage Detector.
• The Voltage Detector’s safety features may
not protect the user if not used in accordance
with the manufacturer’s instructions.
• Check on a known live source within the rated
AC voltage range of the Voltage Detector
before use to ensure it is in working order.
• Insulation type and thickness, distance from
the voltage source, shielded wires, and other
factors may effect reliable operation. Use
other methods to verify live voltage, if there is
any uncertainty.
• Do not use if the Voltage Detector appears
damaged or if it is not operating properly. If in
doubt, replace the Voltage Detector.
• Do not use on voltages that are higher than as
marked on the Voltage Detector.
• Use caution with voltages above 30 Volts AC
as a shock hazard may exist.
• Comply with all applicable safety codes.
Use approved personal protective equipment
when working near live electrical circuits-
particularly with regard to arc-ash potential.
• Do not operate the Voltage Detector if Low
Battery warning occurs. Replace batteries
immediately.
SYMBOLS USED
Potential danger. Indicates the user must
refer to the manual for important safety
information
Equipment is protected by double or
reinforced insulation
SPECIFICATIONS
Detection voltage range: 50V AC to 1000V AC
Frequency range: 50/60Hz
Batteries: Two “AAA” 1.5V
Operating temperature: 32°F to 122°F
(0°C to 50°C)
Storage temperature: 14°F to 140°F
(-10°C to 60°C)
Humidity: 80% max.
Altitude: 2000 meters
Pollution Degree: 2
Safety Compliance: CAT III-1OOOV
NON-CONTACT
AC VOLTAGE DETECTOR
OPERATOR’S MANUAL
ORDER CODE: OXD-516-1336M
CZ HU PL SK TH cromwell.co.uk
• Auto power off
• Low battery self test
• Power ON/OFF switch
• Red LED indicators
• Green LED indicators
• Switchable audible
and silent mode
• Rugged, double
molded case
• CAT III 1000V
DETECTOR DESCRIPTION
1. Voltage ON/OFF button
2.LED indicators
3.Detector tip
4.CAP
5. Locking tab
1
2
3
5
4

Popular Security Sensor manuals by other brands

HH INFLATABLE INSHORE manual

HH

HH INFLATABLE INSHORE manual

B.E.G. LUXOMAT PD4-M-1C Series Installation and operating instruction

B.E.G.

B.E.G. LUXOMAT PD4-M-1C Series Installation and operating instruction

Honeywell Fire Sentry SS3 Installation and operating manual

Honeywell

Honeywell Fire Sentry SS3 Installation and operating manual

THORLABS PDA25K operating manual

THORLABS

THORLABS PDA25K operating manual

ERNITEC Eagle PIR-045 installation manual

ERNITEC

ERNITEC Eagle PIR-045 installation manual

AMC SS400 Installation handbook

AMC

AMC SS400 Installation handbook

elobau 165 Series manual

elobau

elobau 165 Series manual

PCB TORKDISC 5308D-03A Installation and operating manual

PCB

PCB TORKDISC 5308D-03A Installation and operating manual

Meggitt Sensorex 690 043 045 instruction manual

Meggitt

Meggitt Sensorex 690 043 045 instruction manual

DAITEM SH271AX installation manual

DAITEM

DAITEM SH271AX installation manual

Varian 960 Operation and service manual

Varian

Varian 960 Operation and service manual

WATERGUARD Solo user manual

WATERGUARD

WATERGUARD Solo user manual

Arcane SEL MAX Operation manual

Arcane

Arcane SEL MAX Operation manual

Rielta STEKLO-3 installation guide

Rielta

Rielta STEKLO-3 installation guide

TQC LD8100 user guide

TQC

TQC LD8100 user guide

Tatsuta Electric Wire & Cable AD-AS-1LDMA Operation manual

Tatsuta Electric Wire & Cable

Tatsuta Electric Wire & Cable AD-AS-1LDMA Operation manual

Amprobe UAT-620 user manual

Amprobe

Amprobe UAT-620 user manual

Boston PD301 user manual

Boston

Boston PD301 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.