Ozeri CardioTech BP6T User manual

User Manual
CardioTechTM
BP6T Blood Pressure Monitor
Thank you for purchasing this Ozeri Blood Pressure Monitor. Please read this
manual thoroughly before first use, and keep this manual handy for future
reference.
6755 Mira Mesa Blvd.
Suite 123-239
San Diego, CA 92121
Wrist Type

TABLE OF CONTENTS TABLE OF CONTENTS
3
Before Using Your Blood Pressure Monitor
Introduction
Important Safety Information
Health and Blood Pressure Values
Suggestions Before Measuring
Getting to Know Your Unit
LCD Full Display
Device Components & Control Button Descriptions
Charging Your Device
Programming the Unit
Operating Instructions
Applying the Cuff and Positioning
Measuring Your Blood Pressure
About Blood Circulation and Pressure
Irregular Heart Beat?
What is Arrhythmia?
Recalling Records
Deleting Records
Troubleshooting the Unit
Maintenance
4
5
8
9
10
11
12
13
15
16
18
19
21
22
23
24
25
Technical Information
Specifications
Accessories
EMC Guidance
Warranty
Customer Support
26
27
28
29
31
2

INTRODUCTION IMPORTANT SAFETY INFORMATION
4 5
Thank you for purchasing the Ozeri BP6T Fully Automatic
Blood Pressure Monitor. This device uses the oscillometric
method of blood pressure measurement which detects the
movement of blood through your brachial artery, and
converts your blood pressure into a digital reading. The unit
is simple to use because no stethoscope is needed while
using an oscillometric monitor. This device automatically
stores 399 sets of 3 measurement values with date and time
data for 3 users (1197 measurements total). You can access
the stored data simply by pressing the MEM button.
The BP6T Monitor includes the following items:
● Monitor
● Cuff
● Instruction manual printed in English
● Carrying bag
● Built-in rechargeable battery
Safety Information
The following explains the symbols found on this device's
rating label and other locations:
To ensure the correct use of this product, basic safety
measures should always be followed. Read all information in
the instruction manual and any other literature included in the
box before using this device, and observe all Warnings and
Cautions.
Warnings
The following are warnings of potentially hazardous
situations which, if not avoided, could result in death or
serious injury:
● DO NOT confuse self-monitoring with self-diagnosis. This
unit allows you to monitor your blood pressure. Contact
your physician for specific information about your blood
pressure. Self-diagnosis and treatment using measured
results may be dangerous. Follow the instructions of your
physician or licensed healthcare provider.
● Consult your physician before measuring blood pressure,
especially if you have any of the following conditions:
Hypertension, Diabetes, Arteriosclerosis, Kidney or
Vascular Disease, or any conditions affecting circulation.
● DO NOT adjust medication based on measurement results
from this blood pressure monitor. Take medication as
prescribed by your physician. Only a physician is qualified
to diagnose and treat High Blood Pressure.
● The monitor is not intended to be a diagnostic device, for
indoor use only.
●
This device is intended for use in measuring blood pressure
and heart rates for adults only. Do not use on infants or
persons who cannot express their intentions.
● Do not use this device if pregnant. This device is
contraindicated in women who are or may be pregnant.
Consult a physician instead.
● This unit is not suitable for continuous monitoring during
medical emergencies or operations.
● The equipment is not AP/APG equipment and not suitable
for use in the presence of a flammable anesthetic mixture
with air, oxygen, or nitrous oxide.
● If battery fluid should get in your eyes, immediately rinse
with plenty of clean water. Contact a physician immediately.
Precautions
The following are Precautions of potentially hazardous
situations which, if not avoided, may result in minor or
moderate injury to the user or patient or damage to the
equipment or other property:
● Read all of the information in the instruction manual and
any other literature in the box before operating the unit.
● Dispose of the device, components and optional
accessories according to applicable local regulations.
Unlawful disposal may cause environmental pollution.
● Use only Ozeri authorized parts and accessories. Parts and
accessories not approved for use with the device may
damage the unit.
● Operate this device only as it is intended. Do not use this
device for any other purpose.
● Do not use a cellular phone near this device. Cell phones
may inhibit the accuracy of this device.
● Do not disassemble or attempt to repair this device or any
of its components. Doing so will void the warranty.
● Do not use this device where flammable gases (such as
anesthetic gas, oxygen or hydrogen) or flammable liquids
(such as alcohol) are present.
● This device is intended for non-invasive measuring and
monitoring of arterial blood pressure. It is not intended for
use on extremities other than for functions other than
obtaining a blood pressure measurement.
● If you are taking medication, consult your physician to
determine the most appropriate time to measure your blood
pressure.
● If the cuff pressure exceeds 40 kPa (300 mmHg),the unit
will automatically deflate. Should the cuff not deflate when
pressures exceeds 40 kPa (300 mmHg), detach the cuff
from the wrist and press the stop button to stop inflation.
Symbol for “THE OPERATION
GUIDE MUST BE READ”
Symbol for “MANUFACTURER”
Symbol for “SERIAL NUMBER”
Symbol for “MANUFACTURE
DATE”
Type B applied part symbol (USA)
Type BF applied part symbol (UK)
Symbol for “Direct current”
Symbol for “DISPOSAL: Do not
dispose in trash. Follow local laws
for proper disposal and recycling.”
Symbol for “ Class II Equipment”

BEFORE YOU STARTIMPORTANT SAFETY INFORMATION (CONTINUATION)
7
6
To ensure the correct use of this product, basic safety
measures should always be followed. Read all information in
the instruction manual and any other literature included in the
box before using this device, and observe all Warnings and
Cautions.
Warnings
The following are warnings of potentially hazardous
situations which, if not avoided, could result in death or
serious injury:
● DO NOT confuse self-monitoring with self-diagnosis. This
unit allows you to monitor your blood pressure. Contact
your physician for specific information about your blood
pressure. Self-diagnosis and treatment using measured
results may be dangerous. Follow the instructions of your
physician or licensed healthcare provider.
● Consult your physician before measuring blood pressure,
especially if you have any of the following conditions:
Hypertension, Diabetes, Arteriosclerosis, Kidney or
Vascular Disease, or any conditions affecting circulation.
● DO NOT adjust medication based on measurement results
from this blood pressure monitor. Take medication as
prescribed by your physician. Only a physician is qualified
to diagnose and treat High Blood Pressure.
● The monitor is not intended to be a diagnostic device, for
indoor use only.
●
This device is intended for use in measuring blood pressure
and heart rates for adults only. Do not use on infants or
persons who cannot express their intentions.
● Do not use this device if pregnant. This device is
contraindicated in women who are or may be pregnant.
Consult a physician instead.
● This unit is not suitable for continuous monitoring during
medical emergencies or operations.
● The equipment is not AP/APG equipment and not suitable
for use in the presence of a flammable anesthetic mixture
with air, oxygen, or nitrous oxide.
● If battery fluid should get in your eyes, immediately rinse
with plenty of clean water. Contact a physician immediately.
Precautions
The following are Precautions of potentially hazardous
situations which, if not avoided, may result in minor or
moderate injury to the user or patient or damage to the
equipment or other property:
● Read all of the information in the instruction manual and
any other literature in the box before operating the unit.
● Dispose of the device, components and optional
accessories according to applicable local regulations.
Unlawful disposal may cause environmental pollution.
● Use only Ozeri authorized parts and accessories. Parts and
accessories not approved for use with the device may
damage the unit.
● Operate this device only as it is intended. Do not use this
device for any other purpose.
● Do not use a cellular phone near this device. Cell phones
may inhibit the accuracy of this device.
● Do not disassemble or attempt to repair this device or any
of its components. Doing so will void the warranty.
● Do not use this device where flammable gases (such as
anesthetic gas, oxygen or hydrogen) or flammable liquids
(such as alcohol) are present.
● This device is intended for non-invasive measuring and
monitoring of arterial blood pressure. It is not intended for
use on extremities other than for functions other than
obtaining a blood pressure measurement.
● If you are taking medication, consult your physician to
determine the most appropriate time to measure your blood
pressure.
● If the cuff pressure exceeds 40 kPa (300 mmHg),the unit
will automatically deflate. Should the cuff not deflate when
pressures exceeds 40 kPa (300 mmHg), detach the cuff
from the wrist and press the stop button to stop inflation.
IMPORTANT SAFETY INFORMATION (CONTINUATION)

HEALTH AND BLOOD PRESSURE VALUES SUGGESTIONS BEFORE MEASURING
9
8
What is the standard blood pressure classification?
This device refers to a blood pressure classification
published by the American Heart Association (AHA).
The American Heart Association guidelines for the upper
limit of Normal Blood Pressure are 135 mmHg for Systolic
and 85 mmHg for Diastolic.
Only a physician can tell you your normal blood pressure range and
the point at which you are at risk. If the measurements taken with
this product consistently fall outside your normal range, consult
your physician for further testing.
CAUTION
1. Rest for at least 5-10 minutes before taking your blood
pressure.
2. Avoid eating, smoking, exercising, bathing and drinking
(especially alcohol, caffeine or tea) for at least 20-30
minutes before taking a measurement, and avoid talking
while measuring your blood pressure.
3. Make sure the wrist cuff is at heart level.
4. Stress raises blood pressure. Try to keep calm before and
during the measurement process.
5. Avoid a very cold environment.
6. Use the bathroom before taking measurement.
7. Avoid excessive talking and hand movement.
8. Wait at least 20 min after taking bath or shower.
9. Wait 2-3 minutes before retaking your blood pressure
measurement.
Keep the records for your physician and refer to your
physician for guidance. Remember that one reading
does not provide a true blood pressure value; only
long-term records will reveal a more accurate picture
of your blood pressure. Try to take your measurement
at the same time each day to stay consistent.
10.
Blood Pressure Category
Normal
Prehypertension
High Blood Pressure
(Hypertension) Stage 1
High Blood Pressure
(Hypertension) Stage 2
Hypertensive Crisis
(Emergency care needed)
Systolic
mmHg (upper#)
Diastolic
mmHg (lower#)
less than 120
120-139
140-159
160 or higher
Higher than 180
and
or
or
or
or
less than 80
80-89
90-99
100 or higher
Higher than 110
This chart reflects blood pressure categories defined by American Heart Association.
Grade on the blood
pressure monitor
Green - One Bar
Green - Two Bars
Yellow - Three Bars
Orange - Four Bars
Red - Five Bars
The following is a 1999 blood pressure classification chart
published by the World Health Organization (WHO) and
International Society of Hypertension (ISH):

LCD FULL DISPLAY DEVICE COMPONENTS & CONTROL BUTTON DESCRIPTIONS
11
10
Systolic
Blood Pressure
Higher blood pressure produced by
heart’s contraction
Diastolic
Blood Pressure
Lower blood pressure produced by
heart’s relaxation
Pulse Beats per minute
Unit Measurement unit of blood pressure
Time Hour:Minute (Month/Day/Year)
Low Battery Low battery and please charge the power.
Memory Displays measurements stored in memory
IHB Detector Irregular Heartbeat Detector
Heartbeat Heartbeat detection during the
measurement
Grade Blood pressure classifications according
to the American Heart Association
User 1
User 2
User 3
Start measurement and save the results
for User 1
Start measurement and save the results
for User 2
Start measurement and save the results
for User 3
DIASTOLIC
SET/DOWN
BUTTON
START/STOP BUTTON
CUFF
(Type BF applied part)
USB Charging
Interface
SYSTOLIC
PULSE RATE
TIME AND DATE
MEM/UP
BUTTON
Included:
1. Blood Pressure Monitor
(BP6T)
3. User Manual
4. Storage Pouch
2. USB Cable and AC Adaptor
(INPUT: 100-240VAC
50/60Hz 0.3A Max
OUTPUT:5V 1000mA)

PROGRAMMING THE UNIT
13
12
CHARGING YOUR DEVICE
1. The BP6T blood pressure monitor uses a built-in rechargeable
lithium-ion battery, with a capacity of 420 mAh.
2. Please use the AC adaptor and USB cable to charge
the battery, as illustrated in the following picture:
Charge the device when any of the following occur:
displays on the LCD.
The LCD display is dim.
When the LCD fails to light up.
AC adaptor
CAUTION
1. The battery of the BP6T has a built-in rechargeable lithium-ion
battery. Please do not disassemble. Only an authorized technician
may replace it.
2. The unit may recharge up to 300 times under normal usage. If the
battery does not charge and the blood pressure monitor cannot be
used normally, please contact an authorized technician. With a full
charge the unit can be used to measured three times a day for about
25 days.
3. Store the blood pressure monitor in a cool and dry place, and avoid
storing near a heat source as it may cause the battery to explode.
4. Only use the included AC Adapter to charge the unit. You will not be
able to use the blood pressure monitor while it is charging.
5. During the process of charging, the blood pressure monitor will
display the charging icon shown at right. When charging is
finished please unplug before using.
6. Do not use this device while it is charging.
Setting Time Format, Time, Date and Measurement Unit
1. With the unit off, press and hold “SET” button for 3 seconds to enter
Time Setting Mode. The time format will blink first. Press “MEM” button
to change the time format between 12H and 24H.
2. Press 'SET' to confirm your selection [HOUR
FORMAT]. The HOUR setting will then blink for
programming.
3. Press “MEM” to advance in increments of one.
It is important to set the date and time before using your blood pressure
monitor, so that a time stamp can be assigned to each record that is stored
in the memory.

APPLYING THE CUFF AND POSITIONING
1514
PROGRAMMING THE UNIT (CONTINUATION)
8. After the unit has been set it will
display the picture at right and
then turn off automatically.
9. To restart the programming again, press and hold the "SET”
button for 3 seconds and continue with step 1.
4. Press “SET” to confirm the [HOUR]. The proceed to
program the [MINUTE].
5. Repeat Step 3 and 4 to
confirm the [MINUTE].
6. Repeat Step 3
and 4 to confirm
[MONTH], [DAY]
and [YEAR].
7. Repeat Step 3 and 4
to confirm the [UNIT].
Correct Measurement Position
In order to get an accurate reading, sit upright in a chair and rest your left
elbow on the table. If needed use a cushion, pillow or your other wrist for
support. Keep your palm facing up and make sure the monitor is at heart
level. Take a few deep breaths and relax your body, especially between
your elbow and fingers.
Your fingers should be relaxed and in a natural resting position:
Wrist should also be relaxed and in a natural resting position:

MEASURING YOUR BLOOD PRESSURE MEASURING YOUR BLOOD PRESSURE (CONT)
1716
Important Instructions:
● Ensure that you are not eating, talking, laughing or smoking for at least 5
minutes before a measurement.
● Do not talk, read, eat or watch television during measurement. Try your best
to relax and avoid distractions.
● Stimulants such as caffeine and certain medicines can affect your blood
pressure. Taking your blood pressure at the same time every day in a relaxed
setting will provide a better picture of your blood pressure over time.
● Using your blood pressure monitor’s Average function is recommended as
individual results may vary based on other factors, such as stress, exercise,
smoking, ambient temperature, and a recent meal resulting in a full stomach
and/or bladder.
● Taking your blood pressure at home and then at your Doctor’s office can
sometimes lead to different results, due to heightened anxiety sometimes
experienced when visiting the Doctor.
● Ensure that your arm/wrist and heart are level.
● Taking repeated readings in rapid fashion can lead to inaccurate
measurements. Allow for a few minutes to pass before the next reading,
taking care to remain relaxed and calm.
● Always sit upright while taking a measurement and rest your elbow on a flat
surface. Do not cross your legs.
● Ensure that thick clothing is removed when taking a measurement.
● Ensure that the wrist cuff is ¼” to ½” away from the bottom of your palm.
● Ensure that the wrist cuff is fitted so as to allow one finger to fit in between
your wrist and the cuff.
● Do not place cellular phones near the blood pressure monitor.
START
STOP
Starting a Measurement
1. After correctly positioning the cuff, press the
START/STOP button to turn on the device. The user icon
will blink. Press "MEM" to select either User 1, 2 or 3.
2. When the desired User ID blinks, press the START/STOP button
again to confirm the User ID. The device will then display 0 on the
LCD, and initiate a measurement for the selected user.
Measurement
begins at 0
Initial LCD
Display
START
STOP
Inflation and
measurement
begin automatically
Final measurement
displayed on screen
and saved into
memory.
3. Press the START/STOP button to turn off the device. The
device will also turn off automatically after 1 minute of
inactivity.
CAUTION
1. When using this device, please pay attention to the following situations which may interrupt blood flow and influence
blood circulation, potentially causing harm or injury to the user of this device.
●
Too frequent and consecutive multiple measurements.
●
The application of the cuff and it pressurization on any wrist where intravascular access or therapy, or an
arterio-venous (A-V) shunt, is present; Inflating the cuff on the wrist on the side of a mastectomy.
2. Do not apply the cuff over a wound, otherwise it can cause further injury.
3. Do not inflate the cuff on the same limb which other monitoring ME EQUIPMENT is applied around simultaneously,
because this could cause temporary loss of function of those simultaneously-used monitoring ME EQUIPMENT.
4. Excessive use that results in prolonged impairment of the circulation of the blood of the PATIENT.
5. Don’t kink the connection tube, otherwise,the cuff pressure may continuously increase which can prevent blood flow
and result in harmful injury to the PATIENT;
6. This unit is not suitable for continuous monitoring during medical emergencies or operations. Otherwise, the patient’s
wrist and fingers may become numb, swollen, and even purple due to a lack of blood.
Blood Pressure Category
Normal
Prehypertension
High Blood Pressure
(Hypertension) Stage 1
High Blood Pressure
(Hypertension) Stage 2
Hypertensive Crisis
(Emergency care needed)
Systolic
mmHg (upper#)
Diastolic
mmHg (lower#)
less than 120
120-139
140-159
160 or higher
Higher than 180
and
or
or
or
or
less than 80
80-89
90-99
100 or higher
Higher than 110
This chart reflects blood pressure categories defined by American Heart Association.
Grade on the blood
pressure monitor
Green - One Bar
Green - Two Bars
Yellow - Three Bars
Orange - Four Bars
Red - Five Bars
Red
Orange
Yellow
Green

ABOUT BLOOD CIRCULATION AND PRESSURE IRREGULAR HEARTBEAT?
1918
Blood circulation is responsible for supplying the body with
oxygen from the lungs. During each heartbeat cycle, the blood
pressure exerted on the arteries varies between a maximum
(systolic) and a minimum (diastolic) pressure.
The systolic blood pressure value (higher pressure or top value)
represents the blood pressure produced by the heart muscle
when it contracts and pumps the blood out of the heart.
The diastolic blood pressure value (lower pressure or lower
value) represents the blood pressure produced in between
heartbeats when the heart muscle relaxes.
Lower pressure
Relaxation of the
heart muscle
Pressure decreased
on arteries
Blood returns to heart
Higher pressure
Contraction of
the heart muscle
Pressure increased
on arteries
Blood outflow
Diastolic Blood PressureSystolic Blood Pressure
An irregular heartbeat is defined as a heartbeat that varies by
25% from the average of all heartbeat intervals while the unit is
measuring the systolic and diastolic blood pressure.
This Blood Pressure Monitor is equipped with an intelligent
Irregular Heartbeat (IHB) Detector. During each measurement,
the monitor records the heartbeat intervals and works out the
standard deviation. If the calculated value is larger than or
equal to 15, this device will record an IHB.
If an irregular rhythm is detected more than twice during
measurement, the irregular heartbeat symbol with three
hearts will appear on the display along with the
measurement results.
Note: The appearance of the IHB icon indicates that a pulse
irregularity consistent with an irregular heartbeat was
detected during measurement. Usually this is NOT a cause
for concern. However, if the symbol appears often, we
recommend you seek medical advice. Please note that the
device does not replace a cardiac examination, but serves
to detect pulse irregularities at an early stage. Do not use
this device as a substitute for proper medical diagnosis and
check-ups by your physician.
Normal Heartbeat
Irregular Heartbeat
Short Long
Pulse
Blood pressure
Pulse
Blood pressure

WHAT IS ARRHYTHMIA?
2120
IRREGULAR HEARTBEAT? (CONT)
A heartbeat is stimulated by electrical signals that cause the
heart to contract. Arrhythmia is a condition where the
heartbeat rhythm is abnormal due to flaws in the bio-electrical
system that drives the heartbeat. Typical symptoms are
skipped heartbeats, premature contraction, an abnormally
rapid (tachycardia) or slow (bradycardia) pulse. This can be
caused by heart disease, aging, physical predisposition,
stress, lack of sleep, fatigue etc. The appearance of an
irregular heartbeat symbol does indicate arrhythmia.
Arrhythmia and other heart conditions can only be properly
diagnosed by a doctor through a medical examination.
An irregular heartbeat is defined as a heartbeat that varies by
25% from the average of all heartbeat intervals while the unit is
measuring the systolic and diastolic blood pressure.
This Blood Pressure Monitor is equipped with an intelligent
Irregular Heartbeat (IHB) Detector. During each measurement,
the monitor records the heartbeat intervals and works out the
standard deviation. If the calculated value is larger than or
equal to 15, this device will record an IHB.
If an irregular rhythm is detected more than twice during
measurement, the irregular heartbeat symbol with three
hearts will appear on the display along with the
measurement results.
Note: The appearance of the IHB icon indicates that a pulse
irregularity consistent with an irregular heartbeat was
detected during measurement. Usually this is NOT a cause
for concern. However, if the symbol appears often, we
recommend you seek medical advice. Please note that the
device does not replace a cardiac examination, but serves
to detect pulse irregularities at an early stage. Do not use
this device as a substitute for proper medical diagnosis and
check-ups by your physician.
Irregular
Heartbeat
Symbol

DELETING RECORDS
2322
RECALLING RECORDS
Recalling Records in Memory
1. When the monitor is off, press “MEM” button to access the memory. The
LCD will display the average value of the most recent readings first.
2. Press “MEM/UP” button or “SET/DOWN” button to scroll up or down
through the records. Press the "MEM" button to sort the records from the
most recent to the oldest. Press the "SET" button to sort the records from
the oldest to the most recent. Alternatively, press and hold the "SET"
button to skip through the memory in increments of 10, as in M01, M11,
M21, M31, etc. Press and hold “SET” button to review the records as
M01, M11, M21, M31..., etc.
3. To view another user’s records, first ensure that the device is in memory
mode. With the device in memory mode, press the START/STOP button
to turn it off. Then press the START/STOP button again to turn it on. The
user icon will blink on the LCD. Press the “MEM” button to select the
desired user ID, then press “SET” to confirm. The device will turn off.
Pressing the “MEM” button next will activate the device in memory mode
for the selected user ID.
CAUTION
Delete the Records
This device features enhanced memory to store up to 399 records
for 3 different users. The most recent reading is by default shown
first, following by the next most recent reading. Once the memory
is full, i.e. upon taking the 400th measurement, this device will
automatically delete the 1st record from memory.
1. To delete a single or all records from memory for
a given user, first ensure the device is in memory
mode for the intended user. The press and hold
the “MEM” button for 3 seconds. The device will
then display “ALL DEL” in the center of the
screen, and the user number on the bottom left of
the screen. Press “SET” to delete all records.
2. Alternatively, press “MEM” again and the device
will display “ONE DEL” in the center of the
screen, and the user number on the bottom left of
the screen. Press “SET” to delete the single
record.
Note, to exit out of delete mode without deleting any
records, press the START/STOP button before
pressing "SET" to confirm any delete commands.
3. The device will display "DEL DONE" on the
screen to confirm the deletion command was
completed.
4. If the device has no records in memory, the LCD
will display dashes on the screen as shown at
right when pressing "MEM" to enter memory
mode.

MAINTENANCE
2524
TROUBLESHOOTING THE UNIT
The following table includes a list of error messages and the
possible causes and solutions for problems you may
encounter with your blood pressure monitor. If the product is
not operating as you think it should, please check here before
arranging for servicing.
PROBLEM INDICATION CAUSE REMEDY
No power
Low
battery
charge
Error
massage
Display is dim or
will not light up.
Batteries are dead. Charge the device.
Charge the device.
Low battery
charge symbol
on screen
Battery charge is
too low.
E 1 The cuff is not secured
properly. Refasten the cuff
and then measure again.
E 2 The cuff over inflated. Refasten the cuff and
then measure again.
E 3 The cuff is too tight due
to over-inflation.
Relax for a moment
and then measure again.
E 10 or E 11 The monitor detected
motion while measuring.
Movement can affect the
measurement. Relax for
a moment and then
measure again.
Eexx A calibration error
occurred.
Relax and retake the
measurement. If the
problem persists,
contact
further assistance. Refer
to the warranty for
contact information and
return instructions.
Store in a dry cool place and
avoid direct sunshine.
Do not drop or shake the unit,
and do not store objects on the unit.
Only use a clean dry cloth to wipe
the unit. Do not use a damp or
wet cloth. Do not expose any
part of this device to water.
Avoid dusty and unstable
temperature environments
In order to get the best performance and to maximize the life
of your unit please review the following tips:
E 20
E 21 Relax for a moment and
then measure again.
The monitor did not
detect a pulse signal.
Refasten the cuff, taking
care not to overtighten.
Then measure again.
Measurement error.

Storage Pouch:
ACCESSORIES
2726
SPECIFICATIONS
Contact Information
Distributed by Ozeri
Customer service: 1-877-299-1296 or
Email: [email protected]
(OzeriTM and its subsidiaries assume no liability for damage caused by the
use of the Ozeri Blood Pressure Monitor other than for its intended use or
as instructed above and in the User Manual.)
FCC Statement (USA only)
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Compiled Standards List
Charging Adapter:
IEC 60601-1:2005
ASSI/AAMI
SP10:2002/A1:2003/A2:2006/(R)2008
EN 60601-1-2:2007
ISO 14971:2007
EN 980:2008
EN 1041:2008
Risk Management
Labeling
User Manual
General Requirements for Safety
Non-invasive Sphygmomanometers
General Requirements
Electromagnetic Compatibility
Software Lifetime EN 62304:2006/AC:2008
EN 60601-1:2006/AC2010
EN 60601-1-11:2010
EN 1060-1:1995+A2:2009
EN 1060-3:1997+A2:2009
EN 1060-4:2004
EN 60601-1-2:2007/AC:2010
EN/ISO 14971:2012
EN 15223-1:2012
EN 1041:2008
EN 62304:2006/AC:2008
USA EU
Power supply
Display mode Digital LCD V.A.46.5 x 36.5mm
Measurement mode Oscillographic testing mode
Measurement range
Accuracy
Normal working condition
Storage & transportation
condition
Measurement perimeter
of the wrist About 13.5cm - 21.5cm
Net Weight Approx.110g
External dimensions
Included
Approx.79.8 × 72.5 × 13.2mm
USB Cable, AC Adaptor, User Manual,
Storage Pouch
Mode of operation Continuous operation
Degree of protection Type BF applied part
Protection against
ingress of water
Software version
Device classification
V01
WARNING: No modification of this equipment is allowed.
Pressure:
5℃- 40℃within ±0.4kpa (3mmHg)
pulse value: ±5%
Temperature: -20℃to 60℃ RH: 10% to 93%
Atmospheric pressure: 50kPa to 106kPa
Temperature: 5 ℃to 40℃ Relative humidity ≤85%
Atmospheric pressure: 86kPa to 106kPa
3.7V 420mAH Built-in rechargeable lithium-ion
battery, 5V / 1A USB AC Adaptor
IP22, It means the device could protected
against solid foreign objects of 12.5 mm and
greater, and against vertically falling water
drops when ENCLOSURE tilted up to 15°
Rated cuff pressure:
0kpa-40kpa (0mmHg - 300 mmHg)
pulse value: (40-199) beat/minute
Measurement pressure: 5.3kPa-30.7kPa
(40mmHg - 230mmHg)
Battery Powered Mode:
Internally Powered ME Equipment
AC Adaptor charged Mode:
Class II ME Equipment
100-240VAC 50/60Hz 0.3A Max
5V 1000mA
Adaptor
INPUT:
OUTPUT:

FCC STATEMENT
2928
EMC GUIDANCE WARRANTY INFORMATION
Your Ozeri Blood Pressure Monitor, excluding the arm cuff,
is warranted to the original owner for 5 years from the date
of purchase against defects in material and workmanship
under normal use. The arm cuff is warranted to the original
owner for 1 year to be free from defects in material and
workmanship under normal use. Should your blood
pressure monitor and/or arm cuff appear defective within
the applicable period from the date of purchase, return the
defective unit, freight prepaid along with an explanation of
the claim to Ozeri. Please pack carefully to avoid damages
in transit. Under this warranty, Ozeri will repair or replace
any parts found to be defective due to a manufacturer’s
defect. This warranty extends only to personal use and
does not extend to any product that has been used for
commercial use, or use which is not intended. There are no
warranties other than that expressly set forth herein.
EMC Guidance
1. The Blood Pressure Monitor needs special precautions
regarding EMC and needs to be installed and put into
service according to the EMC information provided in the
ACCOMPANYING DOCUMENTS
2. Wireless communications equipment such as wireless
home network devices, mobile phones, cordless
telephones and their base stations, walkie-talkies can
affect this equipment and should be kept at least a
distance d = 3,3m (11ft) away from the equipment.
(Note. As indicated in Table 6 of IEC 60601-1-2:2007 for
ME EQUIPMENT, a typical cell phone with a maximum
output power of 2 W yields d = 3,3 m at an IMMUNITY
LEVEL of 3 V/m)

CUSTOMER SUPPORT
3130
WARRANTY INFORMATION
This warranty is not transferable. Ozeri is not responsible in
any way for damages, losses or inconveniences caused by
equipment failure caused by user negligence, abuse, or
use not in accordance with the “User Guide” or any
additional safety, use, or warnings included in the product
materials. Further, Ozeri is not liable for incidental or
consequential damages of any nature resulting from the
use of this product and any liability shall not exceed the
purchase price of the product.
This Warranty gives you specific legal rights.
You may also have other rights which vary from state to
state.
THIS WARRANTY DOES NOT APPLY TO THE
FOLLOWING:
• Damage due to accident, misuse, abuse,
alterations or vandalism.
• Improper or inadequate maintenance.
• Unauthorized modification or commercial use.
• Damage in return transit.
• Unsupervised use by children under 18 years of age.
Ozeri Customer Service
Customer service: 1-877-299-1296 or
Email: [email protected]
(OzeriTM and its subsidiaries assume no liability for damage
caused by the use of the Ozeri Blood Pressure Monitor
other than for its intended use or as instructed above and in
the User Manual.)