Palstar Incorporated
9676 N. Looney Rd.,
Piqua, OH 45356 USA
Customer Service and Sales Telephone:
1-800-773-7931
Fax:
1-937-773-8003
Email:
in [email protected]
© Copyright 2006 Palstar Inc.
Printed in the U.S.A.
PM2000AM Wattmeter
Owner’s Manual
2 PM2000AM WATTMETER
1- 800-773 - 7931 WWW .PALS T AR .CO M
INSTALLATION
Install your PM2000AM mobile watt-
meter be ore any antenna tuner. This
will give you an accurate means to
measure the SWR o the antenna sys-
tem. I the antenna is cut or the right
requency and a tuner is not required,
connect the PM2000AM as above.
An AC adapter is used to light the
meter & power the peak reading cir-
cuitry, 12 Volts required at 40-50 ma.
A 12v wall trans ormer is supplied with
the wattmeter (For US only). Power
Jack requires 2.1 mm plug center +.
CALI RATION
(not required as shipped)
Using a calibrated source, adjust the
meter calibration as ollows: Terminate
the wattmeter ins a known 50Ω
dummy load through a calibrated watt-
meter o known accuracy.
Pick a level on the 300 watt scale o
the PM2000AM o 100 watts. I the
level is either low or high compared to
the calibrated wattmeter adjust the pot
on the 300 watt scale as noted in the
drawing below to match the readings.
As single tone = peak, same adjust or
peak reading. Similarly on the high
scale pick 500 watts to read on the
calibrated wattmeter and adjust the
orward 3000 watt pot to read the
same on your PM2000AM mobile watt-
meter. Peak adjust as above or high
power settings.
SPECIFICATIONS
POWER RANGE: 300 AND 3000 WATTS ranges
MAX POWER: 2000 WATTS
FREQUENCY RANGE: 1.8 to 60 MHz
DIMENSIONS: 4.5”W x 3.5”D x 4.5”H Meter
Alodine plated aluminum case
WEIGHT: 1.3 LB
PM2000AM WATTMETER 3
1- 800-773 - 7931 WWW .PALS T AR .CO M
PEAK READING
The PM2000AM is capable o reading
peak values in the SSB mode. Depress-
ing the ront panel button PEAK to
read peak will activate the active cir-
cuitry and the meter will exhibit ast
attack and a delay o about 1-1.5 secs.
The peak value will be about 95-100%
o peak SSB power. Depending on the
voice characteristics this may be
higher.
Single tone as it reads on the meter
will read the same in peak mode as
single tone power (average) equals
single tone in peak mode. This is the
way you check to see i the CW single
tone power in the AVG position will
be the same in the peak mode. There
are 2 level controls that you can add i
these readings are not the same in
either the 300 watt or 3000 watt
range. The PEAK/HOLD button i de-
pressed will read PEAK in addition to
holding at the peak value or 2 seconds
approximately. NOTE: the PEAK/AVG
must be depressed in order or HOLD
to unction properly.
LAMP
13.8 V
INPUT

Other Palstar Measuring Instrument manuals

Palstar ZM-30 User manual

Palstar

Palstar ZM-30 User manual

Palstar ZM-30 User manual

Palstar

Palstar ZM-30 User manual

Palstar PM2000AM User manual

Palstar

Palstar PM2000AM User manual

Palstar PM2000AM User manual

Palstar

Palstar PM2000AM User manual

Palstar PM2000A User manual

Palstar

Palstar PM2000A User manual

Palstar PM5K User manual

Palstar

Palstar PM5K User manual

Palstar PM2000AM User manual

Palstar

Palstar PM2000AM User manual

Popular Measuring Instrument manuals by other brands

SZBJ BM802A instruction manual

SZBJ

SZBJ BM802A instruction manual

York Survey Supply 263090 operating instructions

York Survey Supply

York Survey Supply 263090 operating instructions

Emerson E2 quick start guide

Emerson

Emerson E2 quick start guide

EIJKELKAMP 0865 user manual

EIJKELKAMP

EIJKELKAMP 0865 user manual

Extech Instruments MA61 user guide

Extech Instruments

Extech Instruments MA61 user guide

HP 8690B Manual change

HP

HP 8690B Manual change

sauter CP P9 instruction manual

sauter

sauter CP P9 instruction manual

Lutron Electronics HT-315 manual

Lutron Electronics

Lutron Electronics HT-315 manual

Verifii LANDAUER user guide

Verifii

Verifii LANDAUER user guide

Endress+Hauser Prosonic M FMU41 operating instructions

Endress+Hauser

Endress+Hauser Prosonic M FMU41 operating instructions

PCB Piezotronics IMI SENSORS 608A11/-0004 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 608A11/-0004 Installation and operating manual

Biuged BGD 285 instruction manual

Biuged

Biuged BGD 285 instruction manual

OWL CM119 manual

OWL

OWL CM119 manual

Fluke endurance series user manual

Fluke

Fluke endurance series user manual

VDO Viewline 110 mm installation instructions

VDO

VDO Viewline 110 mm installation instructions

Endress+Hauser Proline Promass 80H technical information

Endress+Hauser

Endress+Hauser Proline Promass 80H technical information

Extech Instruments 407113 user guide

Extech Instruments

Extech Instruments 407113 user guide

Gamry Reference 3000 quick start guide

Gamry

Gamry Reference 3000 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.