Panamax M5100-EX User manual

Power Cleaning and
Filtration
Protect or Disconnect™ Automatic
Voltage Monitoring Circuitry (AVM)
LED Voltmeter and Power Status
Indicator Lights
11 Outlets: 4 Always On,
4 Switched, 2 High Current,
1 Convenience (front)
3 Isolated Outlet Banks
Coaxial Signal Line Protection:
1 HD Sat and 1 HD CATV
Auto-resetting Telephone (pay-
per-view) and LAN Line Protection
DC Trigger Input
Rack Mountable (rack mount kit
not included and sold separately-
Part # GRM2204)
Optional Silver Bezel
Improve Picture Quality with Home Theater
Power Conditioners by Panamax
Improves Picture and Sound Quality
Power Cleaning and Filtration eliminates common symp-
toms of contaminated power (including loss of detail, pops, hiss-
es, hums and visual artifacts) and allows your A/V equipment to
perform up to its full capability.
Monitors Incoming Line Voltage and Provides a Visual
Indication of Power Level
Panamax’s patent pending AVM™ circuitry continuously moni-
tors the incoming power as displayed on the LED voltmeter. The
first LED will flash slowly to indicate an under voltage condition
and the last LED will flash to indicate an over voltage condition.
Power to the connected equipment is automatically turned off if
either of these conditions is detected. When voltage returns to a
safe level, power to the equipment is automatically reconnected.
Reduces Cross-Contamination Between Components
The M5100-EX is designed to provide noise isolation between 3
isolated outlet banks including 2 high current outlets so that any
noise created by an A/V component can not contaminate the
power going to equipment plugged into another outlet bank.
L548 REV B 10/06
The Power Specialists Since 1975
®
FEATURES
TOP BENEFITS
www.panamax.com
1
2
3
LEVEL 3
LEVEL 3
THE SOURCE OF PURE SOUND AND PICTURE™
MAX
®
5100-EX
AC Power
Line Voltage:____________________________________________________120V, 60Hz
Total Current Capacity:__________________________________________________15 A
UL1449 Suppression Rating:____________________________________________330V
Protection Modes:______________________________________________L-N, L-G, N-G
Initial Clamping Level:_________________________________________________200V
Energy Dissipation:______________________________________________1815 Joules
Peak Impulse Current:___________________________________________73,000 Amps
Catastrophic Surge Circuit:_______________________________________________Yes
Thermal Fusing:_______________________________________________________Yes
Over-voltage shutoff:__________________________________________142 VAC ±5 VAC
Under-voltage shutoff:________________________________________90 VAC ± 2 VAC
EMI/RFI Noise Filtration
Banks 1 & 2:________________________________________ 80 db, 100 KHz – 2 MHz
Bank 3, High Current Outlets:____________________________60 db, 100 KHz – 2 MHz
Common Mode (all banks)______________________________60 db, 100 KHz - 2 MHz
DC Trigger Input
Jacks:_______________________________________________3.5mm (1/8”) mini-plug
Voltage and Polarity:___________________________________3 - 24V DC, bidirectional
Current Requirement:_________________________________4.6 mA @3V, 58 mA @24V
LAN Circuit
Clamping Level:____________________________________________________8V ± 2V
Jacks:_____________________________________________________________RJ-45
Wires Protected:_______________________________________4-Wires, Pins 1, 2, 3 & 6
Telephone Circuit (pay-per-view)
Fuseless/Auto-resetting:_________________________________________________Yes
Clamping Level:______________________________________________________260V
Capacitance:__________________________________________________30pf (approx.)
Suppression Modes:____________________________________Metallic & Longitudinal
Jacks:_____________________________________________________________RJ-11
Wires Protected:___________________________________________2-Wire, Pins 4 & 5
DSL Compatible:_______________________________________________________Yes
HD Satellite TV Circuit
Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________27V
Attenuation:______________________________________< 1db from 950MHz-2.05GHz
< 2.4db @ 2.2GHz
Connections:__________________________________________Female “F”, Gold Plated
HD Cable TV Circuit
Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________1.4V
Attenuation:________________________________________< 1db from 5MHz - 950MHz
Connections:__________________________________________Female “F”, Gold Plated
Pay-Per-View Compatible________________________________________________Yes
MODEL M5100-EX UNIT CARTON MASTER CARTON
Dimensions Weight Dimensions Weight UPC Qty Dimensions Weight UPC
17" x 12.75" x 3.5" 14 lbs 23.75" x 19.25" x 9.5" 17.5 Lbs 0 50616 00785 6 1 Same as 17.5 Lbs 5 00 50616 00785 1
4.1" H with feet Individual Carton
UPC’s, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
OPTIONAL SILVER BEZEL
SILVER BEZEL PRODUCT UNIT CARTON MASTER CARTON
Model # Dimensions Weight Dimensions Weight UPC Qty Dimensions Weight UPC
BEZ5100-EXS 17" W x 0.625" D x 3.5" H 14.5 Oz 18" x 4" x 1" 18.0 Oz 0 50616 00791 7 N/A N/A N/A N/A
1690 Corporate Circle, Petaluma, CA 94954 •800-472-5555 or 707-283-5900 •Fax - 707-283-5901 • www.panamax.com
MAX®5100-EX REAR PANEL FEATURES
MAX®5100-EX SPECIFICATIONS
Specifications subject to change due to product upgrades and improvements.
Circuit Breaker
Automatically opens
when the current load
is greater than 15
Amps.
Ground Lug
Provides a common
grounding point for
equipment with sep-
arate ground leads.
Main Power
Must be plugged
into a properly
wired & ground-
ed 3-wire outlet
Outlet Bank 1
Four always on outlets. Power will only be turned off
under a fault condition. (See specifications for over-
voltage and under-voltage thresholds) Power is cleaned
by a two-stage balanced Pi filter which also provides
noise isolation from Outlet Banks 2 and 3.
Outlet Bank 2
Four switched outlets controlled by the front panel Power
Button or the DC Trigger input. Bank 2 will turn on imme-
diately and turn off after 10 seconds. EMI/RFI noise filtra-
tion is provided by a two-stage balanced Pi filter which
also provides noise isolation from Outlet Banks 1 and 3.
Outlet Bank 3
Two switched, high current outlets controlled by the front panel Power Button or the DC
Trigger input. Bank 3 has a 5 second turn on delay and turns off immediately. The High
Current outlet provides power from a low impedance noise filtration circuit that does not
limit the current to your equipment. Its output is noise isolated from all other outlet banks.
Voltage Sense Trigger Input
3.5mm (1/8”) Mini-Plug jack. Connect to
a remote trigger device that uses a DC
output to trigger a startup/shutdown
sequence. This bypasses the front panel
power switch.
LAN Jacks
Protection cir-
cuits for 10/100
baseT Ethernet
lines.
Phone Jacks
Protection circuits for
standard telephone
or pay-per-view lines.
Phone circuit is auto-
resetting.
Satellite TV Coax Jacks
Bidirectional protection circuit opti-
mized for satellite TV signal lines.
Cable TV Coax Jacks
Bidirectional protection circuit opti-
mized for cable TV, off-air antennas
and cable modem signal lines.
The Power Specialists Since 1975
®
© 2006 Panamax, Inc. Panamax, MAX and the Panamax logo are registered US trademarks of Panamax. Protect or Disconnect is a trademark of Panamax. SIDACtor is a registered US trademark of Teccor Electronics, Inc.
Rack Mountable (rack mount kit not included and sold separately - Rack Mount Kit / Double DIN, Part # GRM2204)

Other manuals for M5100-EX

1

This manual suits for next models

1

Other Panamax AC Power Distribution manuals

Panamax M5100 User manual

Panamax

Panamax M5100 User manual

Panamax M5500 User manual

Panamax

Panamax M5500 User manual

Panamax M7500-PRO User manual

Panamax

Panamax M7500-PRO User manual

Panamax MIW-POWERKIT-PRO User manual

Panamax

Panamax MIW-POWERKIT-PRO User manual

Panamax MAX 5500-EX User manual

Panamax

Panamax MAX 5500-EX User manual

Panamax MIW-POWER-PRO-PFP User manual

Panamax

Panamax MIW-POWER-PRO-PFP User manual

Panamax MAX 7500-PRO User manual

Panamax

Panamax MAX 7500-PRO User manual

Panamax M7500-PRO User manual

Panamax

Panamax M7500-PRO User manual

Panamax M8C-PRO User manual

Panamax

Panamax M8C-PRO User manual

Panamax Powermax Series PM8-EX User manual

Panamax

Panamax Powermax Series PM8-EX User manual

Panamax M4-EX User manual

Panamax

Panamax M4-EX User manual

Panamax M5400-EX User manual

Panamax

Panamax M5400-EX User manual

Panamax MIW-POWERKIT-PRO User manual

Panamax

Panamax MIW-POWERKIT-PRO User manual

Panamax M5510-PRO User manual

Panamax

Panamax M5510-PRO User manual

Panamax M10-HT-PRO User manual

Panamax

Panamax M10-HT-PRO User manual

Panamax Powermax PM8T-EX User manual

Panamax

Panamax Powermax PM8T-EX User manual

Panamax M4300-EX User manual

Panamax

Panamax M4300-EX User manual

Panamax M5510-PRO User manual

Panamax

Panamax M5510-PRO User manual

Panamax M8DBS-EX User manual

Panamax

Panamax M8DBS-EX User manual

Panamax M4300-EX User manual

Panamax

Panamax M4300-EX User manual

Panamax M5500-EX User manual

Panamax

Panamax M5500-EX User manual

Panamax M5100-PM User manual

Panamax

Panamax M5100-PM User manual

Panamax M4-EX User manual

Panamax

Panamax M4-EX User manual

Panamax Pro MAX 1500-UPS User manual

Panamax

Panamax Pro MAX 1500-UPS User manual

Popular AC Power Distribution manuals by other brands

M-system W2DY instruction manual

M-system

M-system W2DY instruction manual

XINDAK XF-1000ES instructions

XINDAK

XINDAK XF-1000ES instructions

QSC K series specification

QSC

QSC K series specification

ElectroFlip iConserve user guide

ElectroFlip

ElectroFlip iConserve user guide

AudioQuest Niagara 7000 quick start guide

AudioQuest

AudioQuest Niagara 7000 quick start guide

Elgar 351 SL operating manual

Elgar

Elgar 351 SL operating manual

Ametek i Series user manual

Ametek

Ametek i Series user manual

Isotek EVO3 NOVA installation instructions

Isotek

Isotek EVO3 NOVA installation instructions

Monster Power HTS3000 owner's manual

Monster Power

Monster Power HTS3000 owner's manual

ISOL-8 PowerStation user manual

ISOL-8

ISOL-8 PowerStation user manual

ABB SafeRing Installation and operating instructions

ABB

ABB SafeRing Installation and operating instructions

NF DP420LS instruction manual

NF

NF DP420LS instruction manual

Isotek EVO3 AQUARIUS installation instructions

Isotek

Isotek EVO3 AQUARIUS installation instructions

PS Audio MultiWave P1200 Upgrade instructions

PS Audio

PS Audio MultiWave P1200 Upgrade instructions

IKONIX apt 400XAC Series Operation manual

IKONIX

IKONIX apt 400XAC Series Operation manual

Burmester 948 owner's manual

Burmester

Burmester 948 owner's manual

Omega iDRX-ACC user guide

Omega

Omega iDRX-ACC user guide

Leviton 47605-NDP installation instructions

Leviton

Leviton 47605-NDP installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.