manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Panamax
  6. •
  7. AC Power Distribution
  8. •
  9. Panamax M5100-PM User manual

Panamax M5100-PM User manual

MAX®5100-PM
LOOKING FOR CRYSTAL CLEAR PICTURE AND SOUND?
M5100-PM
Level 3 Power Cleaning and Linear Filtration
eliminates common symptoms of contaminated power
(including loss of detail, pops, hisses, hums and visual
artifacts) and allows your A/V equipment to perform up
to its full capability.
1
2
Panamax’s patent pending AVM™ circuitry
continuously monitors the incoming power as displayed on the
digital voltmeter. In case of an undervoltage or an overvoltage, a
flashing lightning bolt will be displayed in red in the voltmeter, and
power to the connected equipment is automatically turned off if
either of these conditions is detected. When voltage returns to a
safe level, power to the equipment is automatically reconnected.
3
The M5100-PM is designed to provide noise isolation
between 3 isolated outlet banks including 2 high current
outlets so that any noise created by an A/V component
can not contaminate the power going to equipment
plugged into another outlet bank.
Improves Picture and Sound Quality
Monitors Incoming Line Voltage and Provides a
Visual Indication of Power Level
Reduces Cross-Contamination Between Components
•11 Outlets
5 Always On, 4 Switched, 2 Switched High
Current.
•High Current Outlets
2 outlets for equipment with high power
demands (Amps/Subwoofers).
• 3 Isolated Outlet Banks
Isolating outlet banks from one another
prevents noise contamination between
components.
•Gaming LAN Port
Easy access to LAN port on front panel.
Perfect for online gaming.
•Digital Volt Meter
Monitor the voltage supplying your home
theater equipment.
•Power Sequencing
Guards against blown fuses and potentially
damaging speaker thump by automatically
powering outlets on and off in sequence.
•12 Volt Trigger
Allows source equipment to activate or
deactivate the outlets on the M5100-PM.
•Clean Power Level 3
Improves picture and sound quality by elimi-
nating noise across the entire AC bandwidth.
60% more efficient at eliminating noise than
single stage linear filtration (Level 2).
•USB Charger
Convenience charger for mp3 players, cell
phones, and other small electronics.
•AVM (Automatic Voltage Monitoring)
Protects equipment against prolonged over/
under voltages by disconnecting the power
and reconnecting it when safe power returns.
HOME THEATER POWER MANAGEMENT
Three Year Product
Warranty*
$5,000,000 Limited
Connected Equipment Policy*
Product Upgrade Program*
* See actual warranty/policy for details.
www.panamax.com
M5100-PM BACK PANEL FEATURES
1. Circuit Breaker:
Automatically opens
when the current load
is greater than 15
Amps. Push to reset.
4. Outlet Bank 1
Four always-on outlets with linear filtration
technology (LiFT). Power will only be turned
off under a fault condition. (See specifications
for over-voltage and under-voltage thresholds)
Power is cleaned by a two-stage balanced Pi
filter which also provides noise isolation from
Outlet Banks 2 and 3.
5. Universal Coaxial
Connectors
3 pairs of bidirectional
protection circuits optimized for
satellite, cable, and antenna
TV signal lines.
3. Outlet Bank 2
Four isolated, switched outlets with linear filtration
technology (LiFT) controlled by the front panel
Power Button or the DC Trigger input. Bank 2 will
turn on immediately and turn off after 10 seconds.
LiFT EMI/RFI noise filtration is provided by a two-
stage balanced Pi filter which also provides noise
isolation from Outlet Banks 1 and 3.
2. Outlet Bank 3
Two switched, high-current outlets controlled by
the front panel Power Button or the DC Trigger
input. Bank 3 has a 5 second turn on delay and
turns off immediately. The High Current outlet
provides power from a low impedance noise
filtration circuit that does not limit the current to
your equipment. Its output is noise isolated from all
other outlet banks.
6. Main Power
Must be plugged into a
properly wired & grounded
3-wire outlet.
8. Bank 1 Indicator Light
Normally ON, is lit when
there is power present on the
Bank 1 receptacles.
10. LAN Jacks
Protection circuits for 10/100 baseT
Ethernet lines. Incoming LAN line MUST
be plugged into the LINE jack. Patch cord
to the equipment MUST be plugged into
the EQUIP jacks. 1 LAN jack goes to the
front panel output jack. 8 wire protection,
50V clamping.
9. Voltage Sense Trigger
Input
3.5mm (1/8”) mono mini-plug.
Connect to a remote trigger
device that uses a DC output
to trigger a startup/shutdown
sequence.
7. Ground Lug:
Provides a common
grounding point for
equipment with separate
ground leads
11. Phone Jacks
Protection circuits for standard telephone
or pay-per-view lines. Phone circuit is
autoresetting. Incoming phone cord MUST
be plugged into the LINE jack. Patch cords
to the equipment (satellite receiver, digital
video recorder, telephone, etc.) MUST be
plugged into the EQUIP jacks.
M5100-PM SPECIFICATIONS
UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
General________________________________________________________________
Dimensions......................................17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet)
Weight........................................................................................................................13.5 lbs.
AC Power_______________________________________________________________
Line Voltage.........................................................................................................120V, 60Hz
Voltage Regulation.............................................................................................................No
Total Current Capacity......................................................................................15 A (1800 W)
Protection Modes.............................................................................................L-N, L-G, N-G
Initial Clamping Level.........................................................................200V Peak, 141V RMS
Energy Dissipation..............................................................................................2125 Joules
Peak Impulse Current........................................................................................60,000 Amps
Catastrophic Surge Circuit................................................................................................Yes
Thermal Fusing:...............................................................................................................Yes
Auto-resetting Over-voltage shutoff...........................................................142 VAC ± 8 VAC
Auto-resetting Under-voltage shutoff...........................................................86 VAC ± 6 VAC
EMI/RFI Noise Filtration___________________________________________________
Bank 1 ............................................................................... Up to -82 db (100 KHz – 2 MHz)
Bank 2 ............................................................................... Up to -80 db (100 KHz – 2 MHz)
Bank 3 ............................................................................... Up to -70 db (100 KHz – 2 MHz)
DC Trigger Input__________________________________________________________
Jacks....................................................................................... 3.5mm (1/8”) mono mini-plug
Voltage and Polarity.........................................................................3 - 24V DC, bidirectional
Current Requirement...................................................................4.6 mA @3V, 58 mA @24V
LAN Protection__________________________________________________________
Clamping Level.................................................................................................... 60V ± 5V
Compatibility......................................................................................................... 10/100bT
Connectors................................................................................................................RJ-45
Wires Protected:.....................................................................................................8-Wires
USB Circuit______________________________________________________________
Jacks...........................................................................................................................USB-A
Power Delivery.............................................................................................500 mA @5VDC
Telco Protection__________________________________________________________
Fuseless/Auto-resetting....................................................................................................Yes
Clamping Level..............................................................................................................260V
Capacitance.....................................................................................................30pf (approx.)
Suppression Modes...........................................................................Metallic & Longitudinal
Connectors...................................................................................................................RJ-11
Lines Protected.........................................................................................2-Wire, Pins 4 & 5
Universal Coax Protection_________________________________________________
HD 1080 i/p Ready...........................................................................................................Yes
Bidirectional......................................................................................................................Yes
Shielded...........................................................................................................................Yes
Clamping Level................................................................................................................75V
Frequency Range.........................................................................................0MHz - 2.2 GHz
Insertion Loss...........................................................................................................< 0.5 dB
Connectors......................................................................................Female “F”, Gold Plated
MODEL M5100-PM MASTER CARTON
UNIT CARTON
Dimensions Weight Dimensions Weight UPC Qty Dimensions Weight UPC
17” x 12.75” x 3.5” 13.5 lbs 23.25” x 19” x 9.25” 18 Lbs 0 50616 00817 4 1 23.75” x 19.75” x 10” 19 Lbs 5 00 50616 00817 9
4.1” H with feet
1690 Corporate Circle, Petaluma, CA. 94954 • 800-472-5555 • 707-283-5900 • Fax 707-283-5901 • www.panamax.com
© 2009 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax
Design and specifications subject to change without notice due to product improvement.
L587 REV. D 12/09
Voltage Protection Rating (UL1449 3rd Edition, 3,000A)...............................................500V

Other manuals for M5100-PM

1

Other Panamax AC Power Distribution manuals

Panamax MIW-POWERKIT-PRO User manual

Panamax

Panamax MIW-POWERKIT-PRO User manual

Panamax M5510-PRO User manual

Panamax

Panamax M5510-PRO User manual

Panamax M5400-EX User manual

Panamax

Panamax M5400-EX User manual

Panamax M8C-EX User manual

Panamax

Panamax M8C-EX User manual

Panamax M4300-EX User manual

Panamax

Panamax M4300-EX User manual

Panamax M4300-EX User manual

Panamax

Panamax M4300-EX User manual

Panamax M4300-EX User manual

Panamax

Panamax M4300-EX User manual

Panamax Powermax PM8DBS-EX User manual

Panamax

Panamax Powermax PM8DBS-EX User manual

Panamax M5400-PM User manual

Panamax

Panamax M5400-PM User manual

Panamax M5100 User manual

Panamax

Panamax M5100 User manual

Panamax M8-EX User manual

Panamax

Panamax M8-EX User manual

Panamax M8DBS-EX User manual

Panamax

Panamax M8DBS-EX User manual

Panamax MAX 5100 User manual

Panamax

Panamax MAX 5100 User manual

Panamax MAX 5410 Pro User manual

Panamax

Panamax MAX 5410 Pro User manual

Panamax M5400-PM User manual

Panamax

Panamax M5400-PM User manual

Panamax M5300-EX User manual

Panamax

Panamax M5300-EX User manual

Panamax MAX 7500-PRO User manual

Panamax

Panamax MAX 7500-PRO User manual

Panamax M5500-EX User manual

Panamax

Panamax M5500-EX User manual

Panamax M5100-EX User manual

Panamax

Panamax M5100-EX User manual

Panamax Pro MAX 1500-UPS User manual

Panamax

Panamax Pro MAX 1500-UPS User manual

Panamax M5100-PM User manual

Panamax

Panamax M5100-PM User manual

Panamax PM8-HT User manual

Panamax

Panamax PM8-HT User manual

Panamax MAX 7500-PRO User manual

Panamax

Panamax MAX 7500-PRO User manual

Panamax M8C-PRO User manual

Panamax

Panamax M8C-PRO User manual

Popular AC Power Distribution manuals by other brands

Liebert MPX user manual

Liebert

Liebert MPX user manual

PS Audio Humbuster HBAC Owner's reference

PS Audio

PS Audio Humbuster HBAC Owner's reference

Furman Elite-16 PF E owner's manual

Furman

Furman Elite-16 PF E owner's manual

Unika PC Series user manual

Unika

Unika PC Series user manual

Elgar TrueWave TW 5550 Operation manual

Elgar

Elgar TrueWave TW 5550 Operation manual

Furman PL-8 II owner's manual

Furman

Furman PL-8 II owner's manual

Torc PowerHub user manual

Torc

Torc PowerHub user manual

Monster Power HTS3000 owner's manual

Monster Power

Monster Power HTS3000 owner's manual

AudioQuest PowerQuest 303 owner's manual

AudioQuest

AudioQuest PowerQuest 303 owner's manual

Furman Elite-16 PF E owner's manual

Furman

Furman Elite-16 PF E owner's manual

ABB SafeRing Installation and operating instructions

ABB

ABB SafeRing Installation and operating instructions

Furman Merit M-8x2 Specifications

Furman

Furman Merit M-8x2 Specifications

APT 6000 Series quick start guide

APT

APT 6000 Series quick start guide

Black Lion Audio PG-1 quick start guide

Black Lion Audio

Black Lion Audio PG-1 quick start guide

AudioQuest NIAGARA 1200UK owner's manual

AudioQuest

AudioQuest NIAGARA 1200UK owner's manual

Pacific Power Source ADF Series Operation manual

Pacific Power Source

Pacific Power Source ADF Series Operation manual

Tripp Lite APS 912 INT owner's manual

Tripp Lite

Tripp Lite APS 912 INT owner's manual

Torus Power IS 5 RK owner's manual

Torus Power

Torus Power IS 5 RK owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.