24
25
29 19
26
22 21 2027 2823
30 31
19. RET switching control connector <RET CTRL>
Connect the cable of the RET switching box here to control the ON/
OFF of RET 1, 2, and 3 and intercom microphone.
For RET 1, 2, and 3, you can select any of the Return A, Return B,
and Digital extender on the camera menu to assign it.
[USER MENU] > [OPERATION] > [SWITCH MODE] > [EXTERNAL
RETURN1] ([EXTERNAL RETURN2], [EXTERNAL RETURN3])
RET A : RET A image switching function is assigned
RET B : RET B image switching function is assigned
D.EXT : Digital extender switching function is assigned
20. Camera HD-SDI output1 connector (BNC) <HD-SDI1>
The camera HD-SDI images are output from this connector.
<Note>
Use a 5C-FB or equivalent cable when outputting the HD-SDI signals.
21. Camera HD-SDI output2 connector (BNC) <HD-SDI2>
Camera images, VF images or RET images can be selected on the
camera menu to output HD-SDI signals from this connector.
[USER MENU] > [OPERATION] > [SETTING] > [HD-SDI2 OUT]
MAIN : Outputs camera images from HD-SDI2
VF : Outputs VF images from HD-SDI2
RET : Outputs return images from HD-SDI2
<Note>
Use a 5C-FB or equivalent cable when outputting the HD-SDI signals.
22. PROMPT output connector <PROMPTER OUT>
The prompter video input from the CCU is output from this connector.
23. External power supply input connector <DC IN>
Connect the input of the external DC power supply to this connector.
(10.8 V to 17 V DC)
<Note>
• Inrush current occurs when the power of this unit is turned on.
Insufficient power supply capacity at power on may cause a failure.
It is recommended to use an external DC power supply with a
capacity that is at least double the total power consumption of this
unit and components (viewfinder, etc.) whose power is turned on
when the power of this unit is turned on. For the DC cable, use a
2-core shielded cable with a core cross section equivalent to or
larger than AGW18 (nominal cross section 0.824 mm 2).
• When using the external DC power supply, be sure to turn ON the
camera power switch <POWER> of the external DC power supply
and then turn ON the camera power switch <POWER> of this unit. If
you turn on the power in reverse sequence, the output voltage of the
external DC power supply rises slowly so this unit may malfunction.
• Check the pin assignment of the DC output terminal on the external
DC power supply and the pin assignment of the <DC IN> terminal
on this unit, and connect the terminals with the correct polarity. (→
page 17)
Incorrect connection of the 12 V power supply terminal to the GND
terminal may cause a fire or failure.
• Operation from the CCU and ROP while using an external DC
power supply is also possible when this unit and the CCU are
connected, but operation is affected by the increase in distance
between this unit and the CCU.
24. MIC1 selector switch1 <FRONT/REAR>
If the MIC1 selector switch2 is set to "MIC," use this to switch the MIC
input signal to FRONT MIC or REAR MIC.
FRONT : Switches to the FRONT MIC
REAR : Switches to the REAR MIC
25. MIC1 selector switch2 <LINE/MIC>
Use this to switch the audio channel1 input signal to LINE or MIC.
LINE : Switches to the LINE input
MIC : Switches to the FRONT MIC or REAR MIC
26. MIC2 selector switch <LINE/MIC>
Use this switch to select LINE or MIC for the audio channel 2 input
signals.
27. Rear MIC1 connector <MIC1>
Connect an audio device or microphone to this connector. The gain
setting can be selected on the camera menu.
The power for the microphone is supplied from this connector,
enabling use of a phantom or AB powered microphone. Turn the
power off when connecting a microphone and then configure the
settings to match the microphone after connecting the microphone.
28. Rear MIC2 connector <MIC2>
Connect an audio device or microphone to this connector. The gain
setting can be selected on the camera menu.
The power for the microphone is supplied from this connector,
enabling use of a phantom or AB powered microphone. Set the power
for a microphone after connecting the microphone.
29. DC output connector <DC OUT 12V 1A>
12 V DC power (up to 1.0 A) can be supplied. If the current exceeds
the rating, the power is turned off forcibly.
R and G tally signals are output. (Open collector type)
30. MIC1 power selector switch <+48V/OFF/AB>
Use this to select the type of power to be supplied to MIC1.
+48V : Phantom 48 V
OFF : Power is not supplied
AB : AB 12 V
31. MIC2 power selector switch <+48V/OFF/AB>
Use this to select the type of power to be supplied to MIC2.
+48V : Phantom 48 V
OFF : Power is not supplied
AB : AB 12 V