VRLA BATTERIES AUGUST 2005
Thisinformationisgenerallydescriptiveonlyandisnotintendedtomakeorimplyanyrepresentation,guaranteeorwarrantywithrespecttoanycellsandbatteries.Cellandbatterydesigns/specificationsaresubjectto
modificationwithoutnotice.ContactPanasonicforthelatestinformation.
VALVE-REGULATED LEAD ACID BATTERIES: INDIVIDUAL DATA SHEET
For main and standby power supplies.
Expected trickle life: 3-5 years at 25°C, Approx. 5 years at 20°C.
LC-R061R3P
Specifications
Characteristics
Dimensions (mm)
Discharge characteristics 77°F (25°C) (Note)
Duration of discharge vs. Discharge current (Note)
Photo/Label for reference only.
(Note) The above characteristics data are average values obtained
within three charge/discharge. Cycles not the minimum values.
Battery case resin: Standard (UL94HB) Color is black.
Terminal type: Faston 187
7.2
6.9
6.6
6.3
6.0
5.7
5.4
5.1
4.8
4.5
4.2
3.9
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
(Minute) (Hour)
Duration of discharge
Terminal voltage (V)
1.3A 0.26A 0.13A 0.065A
30
20
15
10
5
4
3
2
1.5
1
50
40
30
20
10
5
3
30 50 100 300 500 1 3 5 1
Discharge current
(mA) (A)
(Minute) (Hour)
Duration of discharge
104˚F (40˚C)
77˚F (25˚C
32˚F (0˚C)
5˚F (-15˚C)
3.819 0.039 (97 1)
+
-
3.656 (92.9)
0.945 0.039 (24 1)
0.165 (4.2)
+
-
0.925 (23.5)
1.969 0.039
(50 1)
+
-
0.012
(0.3)
3.799 (96.5)
0.187 (4.75)
+
-
+
-
0.165 (4.2)
+
-
Nominal Voltage
Rated Capacity (20 hour rate) 6V
1.3Ah
3.819 inches (97.0 mm)
0.945 inches (24.0 mm)
1.969 inches (50.0 mm)
2.165 inches (55.0 mm)
.661 lbs.(0.30 kg)
LC-R061R3P
Dimensions
Standard Terminals
and Resin
Length
Width
Height
Total Height
Approx. mass
UL94HB Faston 187
Capacity (note)
77˚F (25˚C)
Self discharge
77˚F (25˚C)
0.6A
102%
100%
85%
65%
20 hour rate (65mA)
10 hour rate (120mA)
5 hour rate (210mA)
1 hour rate (850mA)
1.5 hour rate discharge
Cut-off voltage 5.25V
1.3Ah
1.2Ah
1.05Ah
0.85Ah
Internal Resistance Fully charged battery
77˚F (25˚C)
Residual capacity
after standing 3 months
Residual capacity
after standing 6 months
Residual capacity
after standing 12 months
91%
82%
64%
Approx. 50mΩ
0.52 A or smaller
0.195 A or smalle
initial current
Control voltage
initial current
Control voltage
7.25V to 7.45V
(per 6V cell 25˚C
6.8V to 6.9V
(per 6V cell 25˚C
104˚F (40˚C)
77˚F (25˚C)
32˚F (0˚C)
5˚F (-15˚C)
Temperature
dependency
of capacity
(20 hour rate)
Charge
Method
(Constant
Voltage)
Cycle use
(Repeating
use)
Trickle use