5
1-2 Stand-alonesystem
Stand-alone system has three operation modes determined by the way the storage battery is used, the maximum self-
consumption mode, programmed charge/discharge time mode, and back-up mode. Select an operation mode to use
the storage battery. See 8-2 to see how to select.
* If you are a user of the remote-control system, the stand-alone system operates when the programs are not issuing control
commands. The operation mode needs to be set.
* Inordertocorrecttheremainingbatterylevel,charginganddischargingoperationarestoppedonceaday(From3:00to3:30),
except in the backup mode operation.
Maximumself-consumptionmode
• TheproductworksinharmonywithPVgeneration.
• Bystoringexcesselectricityintheproductduringtheday,cleanenergycanbeusedaroundtheclockevenafter
the sun goes down. This allows not only for the maximum utilization of clean energy, but also reduces the user’s
electricity bills.
* Energyisnotsoldtotheutilitywhiletheproductisdischarging.
Programmedcharge/dischargetimemode
• Thecustomercansetthechargeordischargetimeontheproductdirectly.Thebatterywillbechargedor
discharged only during this designated time. At other times it will not be charged or discharged.
* Energyisnotsoldtotheutilitywhilethestoragebatteryisdischarging.
* Set the charging/discharging duration. See 8-4 to see how to set it.
Back-upmode
• Alwayschargethestoragebatteryuntilitisfullycharged,afterithasbeencompletelychargeditisinstandbyin
preparation for a power failure.
1-3 Back-upoperation
When power fails, the product can supply electrical power to the Back-up socket.
* Switch the operation mode manually to back-up operation when power fails. Switch the operation mode manually to grid
operation when the power comes back on. For details, see Chapter 5.
* Back-up operating time is dependent on the "battery remaining" and "connected load". See Chapter 8-3.
NOTICE:
* This is not an UPS (Uninterruptible Power Supply).
* Thedegreeofdeteriorationandtheremainingamountofbatteryinuencepowersupplytime.
* Back-up socket can not be used during Grid Operation.
* Theamountofelectricitythatcanbeusedinback-upsocketisthemaximum1kVA.
* Ifmaximumpowersupplyinback-upsocketismorethan1kVA,powersupplywillstop.
* The low power factor equipment will not work.
* Power supplied from this product is not completely same as the commercial power supply.
* When the battery level reaches zero, the "Buck-up" operation will automatically stop.
The operating state of dimming lights may differ in the case of operating in grid mode and in the case of operating in back-up
mode.
The following equipments are supposed to be connected to the Back-up socket.
* LEDlightbulb/Florescentdesklamp/Incandescentlamp
* Modem
* Router
* Cellular telephony/Smart phone/Tablet computer
* PortableTV/Radio