• Anzeigen und Bedienelemente
H1 - H2: Schaltzustand / Senderfehler-Anzeige - gelb
H3 - H4: Empndlichkeit / Empfängerfehler-Anzeige - grün
H5 - H6: Sensor-Fehler - rot
H7: Alarmanzeige - rot
H8: Betriebsanzeige - grün
S1 - S2: DIP-Schalter Kanal 1
S3 - S4: DIP-Schalter Kanal 2
S5: Test / Reset-Taster
• Display content and operating elements
H1 - H2: Switching indicator / Transmitter error - yellow
H3 - H4: Sensitivity display / Receiver error - green
H5 - H6: Sensor Error display - red
H7: Alarm display - red
H8: Power On display - green
S1 - S2: DIP-switch channel 1
S3 - S4: DIP-switch channel 2
S5: Test / Reset-Taster
• Inbetriebnahme
Vor Inbetriebnahme DIP-Schalter S1 - S2 (S3 - S4) am Gerät passend einstellen.
Sensoren aufeinander ausrichten. Nach Anlegen der Betriebsspannung und
automatischem Reset, stellt sich in die Sendeleistung selbstständig ein. Bei fehlerfreiem
Betrieb leuchtet H3 (H4) auf (Automatik aktiv). Gleichzeitig leuchtet bei Sichtverbindung
zwischen Sender und Empfänger H1 (H2). Bei Unterbrechung erlischt H1 (H2) (siehe
Tabelle: Schaltlogik).
• - Alarm - mit Alarmausgang
Der Alarmzustand tritt ein, wenn der Prozessor die Sendeleistung nicht mehr nachregeln
kann. Ursache ist z. B. eine Verschlechterung der Sicht, eine zu große Distanz oder
Dejustage der Sensoren. Nach Beseitigung des Fehlers erlischt die Anzeige. Im
Alarmzustand liegen 24V DC am Alarmausgang an.
• Testeingang
Legt man an den Testeingang 24 V DC an, so schaltet der Sender ab. Damit kann die
Funktion der Lichtschranke überprüft werden.
• - Test -
Durch kurzes Drücken von S5 - Funktion Test - wird erst die Streckenqualität von
Kanal 1 durch Blinken von H3 (1x - schlecht bis 10x - sehr gut) angezeigt. Ist keine
Sichtverbindung vorhanden, blinkt lediglich H5. Danach folgt das Ergebnis von Kanal
2 mit H4. Ist hier keine Sichtverbindung vorhanden, blinkt lediglich H6.
• - Reset -
Nach Anlegen der Betriebsspannung oder langes Drücken von S5, führt das Gerät
einen Reset durch. Der Reset beinhaltet einen Lampentest. Alle Anzeigen erlischen
und leuchten danach kurz auf. Zusätzlich ndet eine automatische Neuregelung der
Sendeleistung vom Maximalwert auf den Sollwert statt.
• - Sensor Error - mit Errorausgang
Mit der Sensor Error-Funktion überwacht das Gerät den elektrischen Zustand der
Sensoren auf Kurzschluss und Unterbrechung. Tritt ein Fehler auf, so meldet dies das
Gerät durch die Anzeigeelemente und am Ausgang liegen 24V DC an.
Schnelles Blinken bedeutet Kurzschluss und langsames Blinken bedeutet
Unterbrechung (siehe Tabelle Logic Sensor Error).
• Operating procedure
Before operating procedure you have to choose the DIP switch setting S1 - S2 (S3 - S4)
for your application. Sensor heads adjusts one on top of the other. After switch on the
power supply and automatic reset, the transmit power will be turned to the optimum.
When there is no error LED H3 (H4) lights and in light switching mode H1 (H2) - output
status - lights too (See also table: Switching logic).
• - Alarm - with Alarm output
Alarm is active, when the transmit power is not sufcient in the Manual mode or the
automatic adjustment is interrupted. H7 ashes up and the output is active (24V). The
cause can be e.g. deterioration of the beam, too large distance or misadjustment of
sensor heads. Is the cause removed, the alarm is no longer active.
• Test input
With a voltage about 24 V DC at the test input, the transmitter beam switches off. With
this feature you can test the system.
• - Test -
Short-time pressing of button S5 results ashes between 1 and 10 times of H3 to signal
the received power of channel 1. They are proportional to the received signal. If there
is no received signal, only H5 ashes up. After that the same procedure starts with
channel 2. Here H4 signals the quality and if there is no signal, only H6 ashes up.
• - Reset -
After connecting the device with power supply or pressing of button S5 for longer time,
a Reset will done. This means a test of all displays. All LEDs lights down and up for a
short time. Additionally a new adjustment of the transmit power starts from maximum
to the nominal value.
• - Sensor Error - with error output
This function controls the electrical state of the sensor heads. If there is an error
(short-circuit or too high resistance resp. disconnection) H5 (H6) lights up and the
output is active (24V). Additionally H1 (H2) (= transmitter error) or / and H3 (H4) (=
receiver error) ashes slowly (= high resistance) or fast (= short-circuit). See for this
table Logic Sensor Error.
Technische Daten (bei 20 °C Ub= 24 V DC) ISM-2800 Technical data (at 20 °C (68 °F), Vs= 24 V DC)
Betriebsspannung 24 V DC / ± 20% / 3,6 W Supply power
Messverfahren moduliertes IR-Licht modulated IR-light Operating basis
Maximale Reichweite (Einweg) Maximum range (Through beam)
Sender Empfänger / Receiver IRL-... Empfänger / Receiver IRH-..., IR-... Transmitter
ITL-..., IT-... 8 m (26 ft) 20 m (66 ft) ITL-..., IT-...
ITH-..., IT-...HP 10 m (33 ft) 30 m (99 ft) ITH-..., IT-...HP
ITA-... 20 m (66 ft) 55 m (182 ft) ITA-...
Sendefrequenz 4,0 kHz Transmit frequency
Multiplexgeschwindigkeit 8 ms Multiplex speed
Sendeleistung automatisch automatic Transmit power
Schaltfunktion bzw. Schaltverhalten hell light Switching behavior
Grundleistung low 1 / low 2 / high 1 / high 2 System power manual mode
Schaltverzögerung / Impulsbreite — Switching delay / impulse period
Schaltausgang (kurzschlussfest) Schließer (Halbleiter-Relais) NO (Semiconductor-Relay) Switching output (short-circuit proof)
Schaltwerte maximal 100 mA / 60 V AC (DC) Maximum values
Reaktionszeit 24 ms Reaction time
Alarm-/Errorausgang (kurzschlussfest) pnp: 100 mA / 24 V DC Alarm / Error output (short-circuit proof)
Analogausgang — Analog output
Testeingang Active HIGH (L = 0 ... 5 V DC, H = 15 ... 30 V DC) Test input
Gehäusewerkstoff NORYL RAL 7035 (grau / grey) Housing material
Schutzart IP 20 Protection class
Anschluss-Querschnitt 0,14 ... 2,5 mm² Terminal size
Maximale Kabellänge (Sensor-/Signalanschlüsse) 30 m Maximum cable length (sensor and signal connections)
Betriebstemperatur -25 °C ... +50 °C (-13 °F ... +122 °F) Operating temperature
Gehäuseabmessungen siehe Maßzeichnung see dimensions Housing measurements
Prüfungen Approvals
IT
IT
SENSOR ERROR
H5 (H6)
OUTPUT-STATUS
H1 (H2)
GAIN-CONTROL
H3 (H4)
Kurzschluss|short-circuit
hochohmig|highresistance
Kurzschluss|short-circuit
hochohmig|highresistance
IR
IR
schnellesBlinken
fast flashes
langsames Blinken
slowly flashes
schnellesBlinken
fast flashes
langsames Blinken
slowly flashes
• Maßzeichnungen / Dimensions in mm
H1 H2
H3 H4
H5 H6
S5
Channel 1
Channel 2
H7-H8
S1-S2
S3-S4
• Logik Sensor Error / Logic Sensor Error