manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Paradox
  6. •
  7. Media Converter
  8. •
  9. Paradox DGP-CONV1 User manual

Paradox DGP-CONV1 User manual

NEware RS-485/RS-232 Converter
(DGP-CONV1)
Instructions
DGPCONV1-EI00
INTRODUCTION
The DGP-CONV1 converter is a local interface between the DigiplexNE
(DGP-NE96) control panel and the NEware System Owner Software.
Connected directly between a computer and the DigiplexNE, the DGP-
CONV1 will transfer information at a speed of 19,200 or 38,400 baud to a
distance of up to 1000ft (300m).
OVERVIEW
The converter comes in two parts, the Alarm Panel (AP) Board and the
Computer (CPU) Board (see Figure 1). The AP board is installed in the metal
box that houses the control panel while the CPU board is installed close to
the computer. The boards are then connected together to complete the
interface. Figure 1 shows a general overview of the DGP-CONV1 converter.
HARDWAREINSTALLATION
1. Attach the supplied 4-pin cable to the 4-pin connector on the AP board
and then insert the other end of the cable into the 4-pin connector labeled
“SERIALPORT”on the DigiplexNE control panel (see Figure 2).
2. Connect the +12V, GND, A+and B-terminals of the AP board to the corre-
sponding terminals of the CPU board as shown in Figure 2.
3. Insert the phone jack end of the supplied DB-9 cable into the telephone
connector of the CPU board. Connect the other end of the DB-9 cable into
the desired COM port of the computer. Refer to Figure 2.
NEWARESETUP
In order to use the DGP-CONV1 it must be setup in the NEware software.
After starting the software, click the COM Port icon. The COM Port
Configuration window will appear. Select the COM port to which the
converter is connected to and then select the communication speed (BPS -
baud rate). Note: When selecting the baud rate, be sure to select the
same baud rate as set in the DigiplexNE. When finished, click OK.
CONNECTING THEDGP-CONV1 WITHIN8M(25FT.)
If the distance between the between the DigiplexNE and the computer is
within 8m (25ft.), only the AP board will be required. To connect the DGP-
CONV1 using this method:
1. Attach the 4-pin supplied cable to the 4-pin connector on the AP board
and then insert the other end of the cable into the 4-pin connector labeled
“SERIALPORT”on the DigiplexNE control panel (see Figure 3).
2. Insert the phone jack end of the supplied DB-9 cable into the telephone
connector on the AP board. Connect the other end of the DB-9 cable into
the desired COM port of the computer. Refer to Figure 3.
Figure 1: DGP-CONV1 Overview
Figure 2: Connecting the DGP-CONV1 Converter
Figure 3: Connecting the DGP-CONV1 8m (25ft.)

Other Paradox Media Converter manuals

Paradox UC300 User manual

Paradox

Paradox UC300 User manual

Paradox UC300 User manual

Paradox

Paradox UC300 User manual

Paradox IPC10 User manual

Paradox

Paradox IPC10 User manual

Popular Media Converter manuals by other brands

DENAFRIPS Terminator manual

DENAFRIPS

DENAFRIPS Terminator manual

VideoLogix Proteus-V user manual

VideoLogix

VideoLogix Proteus-V user manual

Westermo MA-45 AC installation manual

Westermo

Westermo MA-45 AC installation manual

Triax CC2CT 800 C Assembly instruction

Triax

Triax CC2CT 800 C Assembly instruction

Cypress CM-392 Operation manual

Cypress

Cypress CM-392 Operation manual

PESA PRO-HDMI2HD user guide

PESA

PESA PRO-HDMI2HD user guide

Ambery MPV-16X user manual

Ambery

Ambery MPV-16X user manual

Chauvet Professional NET-XII quick start guide

Chauvet Professional

Chauvet Professional NET-XII quick start guide

Tascam MM-2D-E owner's manual

Tascam

Tascam MM-2D-E owner's manual

SVP HDE-70 manual

SVP

SVP HDE-70 manual

Converters.TV 444 Operation manual

Converters.TV

Converters.TV 444 Operation manual

Stradis SDM290e user guide

Stradis

Stradis SDM290e user guide

FOLSOM SmartVIEW Installation and operator's manual

FOLSOM

FOLSOM SmartVIEW Installation and operator's manual

Stoltzen ECHO SP12 user manual

Stoltzen

Stoltzen ECHO SP12 user manual

Comtech EF Data UT-4505 Installation and operation manual

Comtech EF Data

Comtech EF Data UT-4505 Installation and operation manual

Steren 208-150 instruction manual

Steren

Steren 208-150 instruction manual

OTS FT800-SSTSA Installation and operation manual

OTS

OTS FT800-SSTSA Installation and operation manual

Cypress CP-262DPC Operation manual

Cypress

Cypress CP-262DPC Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.