Paradox Matrix2000 User manual

Matrix2000
User Guide - CPD
Advanced Analog Fire Alarm Control Panel
4 – 24 Zones
Version: 2.0
Revision: 0.2

IMPORTANT INFORMATION
Limitation of liability
It is mandatory, Matrix2000 panel to be installed in accordance with this manual, applicable codes,
and the instructions of the Authority Having Jurisdiction. The manufacturer shall not under any cir-
cumstances be liable for any incidental or consequential damages arising from loss of property or
other damages or losses owing to the failure of products beyond the cost of repair or replacement
of any defective products. The manufacturer reserves the right to make product improvements and
change product specications at any time.
The manufacturer assumes no responsibility for errors or omissions, while every precaution has
been taken during the preparation of this manual to ensure the accuracy of its contents.
Warranty
PARADOX FIRE warrants its products to be free from defects in materials and workmanship under
normal use for a period of two (2) years (the “Warranty Period”) from the production-delivery date,
identied by date code(s) indicated on the products. Because PARADOX FIRE does not install or
connect the products and because the products may be used in conjunction with products not man-
ufactured by PARADOX FIRE, PARADOX FIRE cannot guarantee the performance of the re alarm
system and shall not be responsible in any way whatsoever for faulty installation or connection.
RoHS directive compliance
The EC RoHS guideline has been released in order to reduce the heavy metal load in
electrical and electronic products caused by e.g. lead and mercury. All manufacturers
are obligated to provide only RoHS-compliant products to the European market, effective
from July 1st, 2006.
PARADOX FIRE hereby states that Matrix2000 panel is fully compliant with RoHS
2002/95/EC directive.
Disposal of your old appliance
1. When this crossed-out wheeled bin symbol is attached to a product it means the prod-
uct is covered by the European Directive 2002/96/EC.
2. All electrical and electronic products should be disposed of separately from the mu-
nicipal waste stream via designated collection facilities appointed by the government or
the local authorities.
3. The correct disposal of your old appliance will help prevent potential negative conse-
quences for the environment and human health.
4. For more detailed information about disposal of your old appliance, please contact
your city ofce, waste disposal service or the shop where you purchased the product.

1. General Description 4
2. Keyboard Indications and Controls 4
2.1 POWER Indication 4
2.1.1 Battery faults 5
2.2 System FAULT indication (General Fault) 5
2.3.1 SIGNALING DEVICE fault 6
2.3.2 EARTH fault 6
2.3.3 AUX POWER Fault 6
2.4 Zone Fault indications 6
2.5 System ALARM indication 7
2.6 Zones ALARM indications 7
3. Central Electric Keyswitch 8
4. Controls Via Keypad 9
4.1 System SILENCE key 9
4.2 System TEST key 9
4.3 System RESET key 9
4.4 Zones BYPASS keys 9
TABLE OF CONTENTS

45
1. General Description
The Matrix2000 advanced analog re alarm control panels have been designed to
provide full re detection coverage to buildings or installations that require re detection
systems of 4 to 24 zones.
There are six (6) basic models for the Matrix2000 panel:
Model Zones Common Relays
M2004 4 2
M2008 8 2
M2012 12 2
M2016 16 2
M2020 20 2
M2024 24 2
Table 1. Matrix2000 panel models
Operating Voltage 220-240 VAC / 50-60Hz or 110-120 VAC / 50-60Hz.
Matrix2000 panel has the following optional components:
- Expansion Zone Board
- Expansion Relay Board
- Remote Zone Annunciator
The analytic indications and the simple controls of the Matrix2000 panel ensure the
easy handling and controlling of the system by the operator.
2. Keyboard Indications and Controls
Operating, monitoring and programming of the panel is performed in three different ac-
cess levels. Access to level 2 is achieved by the keyswitch on the face of the panel
(Figure 1). Operations at access level 2 are performed with the silicon rubber keypad.
Access level 3 operations are accomplished with the microswitches on the main circuit
board of the panel.
Figure 1. Matrix2000 keyboard
2.1 POWER Indication
The POWER indication is permanently ON if the main power is present and batteries are
healthy. This condition signies normal system operation.
POWER indicator OFF signies a total power failure of the system. This can be due to a

45
Matrix2000 - Advanced Analog Fire Alarm Control Panel
number of reasons. Some of them are:
Main power failure for an extended period of time during which the batteries have•
been depleted.
Blown main board fuse.•
Other malfunction of the power supply, main board disconnected from PSU (power•
supply unit) etc.
Blinking power indicator signies one of the following :
(a) Removal or power loss of the batteries.
(b) Main power loss.
(c) Blown main power fuse or PSU fuse.
In the above cases, SYSTEM FAULT indicator turns ON and the on board buzzer sounds
continuously.
2.1.1 Battery faults
The Matrix2000 panel uses a battery fault detection system that will generate a battery
fault indication in the following cases:
Battery missing.•
Battery wiring open circuit.•
Battery not able to charge (low voltage).•
Battery wear (increased internal resistance of batteries).•
2.2 System FAULT indication (General Fault)
GENERAL FAULT, indicates a problem in the system. It turns ON in case of:
Zone wiring connection problems,•
Signalling devices output wiring problems•
Relays outputs wiring problems (auxiliary relays MER4 or MER8).•
Auxiliary power faults•
Earth fault condition•
The above mentioned problems could be open circuits, shorts between wires or shorts
between wires and earth.
Consequently the Fault relay output is activated. At the same time there will be a continu-
ous audible notication from the on board Buzzer.
It is possible to silence the Buzzer by pressing the SILENCE key, with the keyswitch in
position Control Enable.
When the problems causing the indication are restored all the above indications will turn
off automatically.
Short Normal Open
Min Max Min Max Min Max
Signalling device 0 250 2.5K 9K 17K ∞
Zone 0 20 1K 6K 10K ∞
Relay OUT (8) 0 320 4K 10K 30K ∞
Table 2. Fault detection values (Ohm)

67
Matrix2000 - Advanced Analog Fire Alarm Control Panel
67
2.3 Additional system fault indications
In this group three distinct fault conditions are indicated:
2.3.1 SIGNALING DEVICE fault
When active, this indicator signies a fault condition of the signaling device output. The
fault can be one of the following:
Short circuit of the two output wires•
Open circuit in the connecting cable between the block connector and the signaling•
device. The signaling device must be terminated with a 4.7K Ohm resistor (EOL)
Blown fuse that protects the system from shorts while the signalling device is in •
operation.
2.3.2 EARTH fault
When active, this indicator signies a short circuit between any of the panel’s wiring
(zones, relays, outputs etc.) and the building’s earth is detected.
The signaling device output wires are also monitored for the earth short condition.
2.3.3 AUX POWER Fault
When active, this indicator signies an overcurrent condition at the auxiliary power out-
put is detected. The maximum allowed current is 1 Amp. The device is capable of con-
tinuous operation even at full short circuit of this output; though any device powered from
this output will stop functioning.
If more than 1 Amp is required, a compatible EN 54-4 approved re alarm power supply
must be used. When such a power supply is used, the -24 OUT connection of the panel
must be connected to the negative terminal of the auxiliary power supply.
2.4 Zone Fault indications
The Zone Fault indications will blink, in a different pattern, (Figure 2, page 6) depending
on the type of the problem that occurs.
In detail:
(a) If a short-circuit or an opening of a zone is detected, System FAULT indication will
turn ON, the corresponding Zones FAULT indication will blink as in Pattern A, (Figure 2,
page 6) and at the same time there will be an audible notication from the on board
Buzzer.
Possible causes of a zone problem are:
(a1) Disconnection or interruption of wiring of the zone.
(a2) Short-circuit in the wiring of the zone.
(a3) Removal of sensor from its base.
(a4) Removal of the terminating resistor (EOL).
(b) When a Relay expansion module is used the Zones FAULT indication is also trig-
gered by:
A short-circuit or opening of the wiring in the corresponding zone relay output.•
Removal of the output terminating resistor (EOL).•
In case (b) as listed above the System FAULT indication will turn ON and the Zones
FAULT indication of the corresponding zone will blink (Figure 2, Pattern b). At the same
time there is also an audible notication from the on board Buzzer.

67
67
Matrix2000 - Advanced Analog Fire Alarm Control Panel
(c) In the case that both of the above cases occurs, the LED indication starts blinking
(Figure 2, Pattern c), while at the same time there is an audible notication from the on
board Buzzer.
Duration that LED is turned ON Duration that LED is turned OFF
Fault LED Indications
250msec
Pattern A
Pattern B
Pattern C
Zone Fault + Relays Outputs Fault Time
Expansion Relays Outputs Fault (short-circuit or open)
500msec
Zone fault (short-circuit or open zone)
2sec 2sec
1750msec
Figure 2. Zones Fault indications
To silence the Buzzer, press the SILENCE key, with the keyswitch in position Control
Enable. The System FAULT indication remains ON in order to show that a problem ex-
ists in the installation. The Buzzer sounds in regular time intervals, in order to remind
the user the existence of the problem. All the indications will turn OFF automatically after
all problems are restored.
Software Watchdog
The Matrix2000 panel contains a watchdog circuit that will activate when the micropro-
cessor is either faulty or unable to execute the programmed rmware. Upon detection,
the Fault relay, the on board sounder and the fault indicator on the user interface are all
activated.
2.5 System ALARM indication
When the system detects a condition of re (smoke, high temperature etc), the panel
turns in Alarm Mode and the System ALARM indication turns ON. At the same time
there is a continuous audible alarm from the sounder or sounders that are connected on
the main board.
System ALARM indication also turns ON when the evacuation of a protected area is
required. It can be accomplished by turning the keyswitch in the Evacuate position.
In both cases the indication is blinking when a Zones ALARM has occurred (Figure 3).
In the above cases the on board buzzer will also sound.
2.6 Zones ALARM indications
Zones ALARM indicators blink (Figure 3) each time a detector or a manual call point
from the corresponding zone is triggered.
When the call point and all smoke detectors are restored, the system will continue in

89
Matrix2000 - Advanced Analog Fire Alarm Control Panel
89
Alarm Mode. To silence the Buzzer, press the SILENCE key, with the keyswitch in the
Control Enable position. All indications will remain ON until the Reset button is pressed.
Keypad buttons are active only when the keyswitch is turned to the Control Enable
position.
Figure 3 shows the alarm LED indications when activated by detectors, manual call
points and evacuation keyswitch.
Duration that LED is turned ON Duration that LED is turned OFF
Alarm LED indications
250msec
Zones in Alarm
from detector or
evacuation
keyswitch
Time
Zones in Alarm
from manual
call point
(120 Ohm)
2 sec
Figure 3. Zones Alarm indications
Alarm LED indication will blink according to the main signalling device alarm output
pattern.
3. Central Electric Keyswitch
Coperations are accessed when the Electric Keyswitch is set to the appropriate position
(Figure 1). The central electric Keyswitch has three positions:
1st position (Access Level 1) Normal: This is the Normal operation mode. The panel
waits for alarm events or any faults that may develop in the installation. All buttons on the
silicon rubber keypad are disabled.
2nd position (Access Level 2) Control Enable: Alarm events and possible faults are
detected, all buttons on the silicon rubber keypad are active and the system is control-
lable.
For Normal operation the keyswitch must be in the 1st position.
3rd position (Access Level 3) Evacuate: After a small delay of approximately 2 sec-
onds all the system zones turn into Alarm Evacuation Mode resulting in the activation of
all signaling devices in the protected area. The sounder connected on the main board
gives a continuous sound. In case that a MER-8 relay module is used, the extra relays
are activated and connected sounders give an intermittent sound. The system returns
to standby mode by turning the key to the Control Enable position and pressing the
RESET button.
The key from the Keyswitch can be removed only when the keyswitch is in the Normal
position.

89
89
Matrix2000 - Advanced Analog Fire Alarm Control Panel
4. Controls Via Keypad
Keypad keys, are activated only when the key of the Keyswitch is set in the Control
Enable position.
4.1 System SILENCE key
Pressing the SILENCE key will cause any existing audible signal to stop. If a
new event occurs, the silenced condition will be canceled and the appropriate
devices will resound.
4.2 System TEST key
By pressing the System TEST key all the visual indicators of the keypad turn
ON, conrming that none of the LEDs are damaged. The condition is main-
tained for as long as the System TEST key is kept pressed. The buzzer and the
main sounders are also active during the test.
4.3 System RESET key
The System RESET key is used for resetting the system’s zones in Standby
mode after an alarm.
4.4 Zones BYPASS keys
(also called zone disablements)
The Zones BYPASS keys are used to prevent the corresponding zone from causing
an alarm. Note that zone disablements must not be a permanent working condition and
they must be used only as a temporary action. For example zone bypassing can be used
in case of building maintenance or other activities that can trigger false alarms on the
detectors.
Bypassing a zone is achieved by positioning the keyswitch in the Control Enable posi-
tion and then pressing the corresponding Zones BYPASS key. At the same time
the indicator is turned ON. It only returns to normal operation by pressing the
same key again (toggle action). If one of the Zones BYPASS key indicators is
turned ON (yellow color) the corresponding zone is isolated and does not cause
alarms. If an error occurs to a bypassed zone, the General FAULT indicator is
activated but the system stays in silent mode. An alarm condition to a bypassed
zone is recognized and indicated but do not activate the sounders.
If any of the zones is in bypass state the buzzer sounds every 1 minute to re-
mind the user of the existing disablement.

10 11
Matrix2000 - Advanced Analog Fire Alarm Control Panel
10 11
RESPONDING TO ALARM SIGNALS
Evacuate the area.1.
Notify the proper authorities immediately2.
and state the nature and location of the
emergency.
Be prepared to provide directions to re-3.
ghters when they arrive.
TO SILENCE ALARM NOTIFICATION SIG-
NALS
Alarm notication signals should not be
silenced until after all occupants have
been evacuated.
Turn the keyswitch of the keyboard to Con-1.
trol Enable and press the Silence button.
The Silenced button turns ON and all audible
notication circuits turn OFF. New alarm events
turn the notication circuits back on.
TO RETURN THE SYSTEM TO NORMAL AF-
TER AN ALARM
Make sure all smoke detectors are free1.
from smoke and all manual pull stations
are reset
Turn the keyswitch of the keyboard to Con-2.
trol Enable.
Press Reset.3.
TO PERFORM A LAMP TEST (panel and re-
mote annunciators)
Press and hold the Test button.1.
RESPONDING TO TROUBLE SIGNALS
Turn the keyswitch of the keyboard to Con-1.
trol Enable.
Silence the panel buzzer.2.
Investigate the cause of the trouble and3.
notify the authorized service personnel im-
mediately.
TO SILENCE THE PANEL BUZZER
Press Panel Silence.1.
The buzzer turns OFF. Any new events turn the
buzzer back on. Trouble conditions not cleared
resound the buzzer after a predetermined time.
Trouble conditions may affect the pan-
el’s ability to provide early detection and
indication of a re. Clear trouble condi-
tions immediately.
PERIODIC TEST RECOMMENDATIONS
See “Maintenance,” in the Matrix2000 Installa-
tion and Operation manual (Section 14, page
18).
Installed by
Name:
Company:
Address:
Phone:
For service contact
Company:
Address:
Phone:
Acceptance Inspection by
Date:
DEVELOPED BY
Korinthou 3, Metamorfosi
144 51 - Athens, Greece
Compliance Statement
Matrix2000 panel is designed and manufactured
so that it fulll the requirements of CDP 89/106/
EEC directive and are certied to directive CDP
89/106/EEC and EN 54 Part 2 and 4,1998
Standards.
Matrix2000 Fire Alarm Control Panel Operating Instructions

10 11
10 11
Matrix2000 - Advanced Analog Fire Alarm Control Panel
ZONES DESCRIPTION
Zone 1:______________________________________________________________________
Zone 2:______________________________________________________________________
Zone 3:______________________________________________________________________
Zone 4:______________________________________________________________________
Zone 5:______________________________________________________________________
Zone 6:______________________________________________________________________
Zone 7:______________________________________________________________________
Zone 8:______________________________________________________________________
Zone 9:______________________________________________________________________
Zone 10:______________________________________________________________________
Zone 11:______________________________________________________________________
Zone 12:______________________________________________________________________
Zone 13:______________________________________________________________________
Zone 14:______________________________________________________________________
Zone 15:______________________________________________________________________
Zone 16:______________________________________________________________________
Zone 17:______________________________________________________________________
Zone 18:______________________________________________________________________
Zone 19:______________________________________________________________________
Zone 20:______________________________________________________________________
Zone 21:______________________________________________________________________
Zone 22:______________________________________________________________________
Zone 23:______________________________________________________________________
Zone 24:______________________________________________________________________

Document Part Number: MATRIX-UG01, CPD
version 2.0, revision 0.2 - November 2010
Table of contents
Other Paradox Smoke Alarm manuals
Popular Smoke Alarm manuals by other brands

Universal Security Instruments
Universal Security Instruments MDS300CN quick start guide

First Alert
First Alert SCO500A user manual

System Sensor
System Sensor Innovair DH100ACDCLWP Installation and maintenance instructions

Hioth
Hioth CT-SMZW2007-FBR manual

NORDIC QUALITY
NORDIC QUALITY 189911 manual

Ei Electronics
Ei Electronics Ei 176 Optical Technical specifications