I98A - 0319
PARATRONIC – ZI - Rue des Genêts - 01600 REYRIEUX- FRANCE- Phone : +33 4 74 00 12 70 2/4
Email: info@paratronic.com - WEB: http://www.paratronic.com – Download: ftp://ftp.paratronic.info
1
SAFETY INSTRUCTIONS
:
WARNING: This devices must be powered by a LIMITED POWER SOURCE.
If this devices are used in an unspecified manner, the protection provided by these devices may be compromised.
A suitable cut-off device must be planned outside the equipment.
Details of symbols and safety markings are provided on the last page of this documentation (§7).
2
DESCRIPTION
The PARATRONIC PLV400 pluviometer is designed to measure precipitations collected at ground level.
The following options are available for the pluviometer:
- PLV400CHAUF: Integrated heating system which melts precipitations down to -30°C.
- PLV400PIED: Base which positions the collection ring of the PLV400 1 metre from the ground.
- PLV400PAREOISEAU: Ring around the collector which dissuades birds from perching on it.
3
TECHNICAL DATA
3.1
METROLOGICAL DATA
Collection area 400 cm²
Sensitivity: 0.2 mm / pulse
3.2
MECHANICAL DATA
Collection area 400 cm²
Structural materials anodised aluminium
Bolting materials stainless steel
Dimensions dia.=234 x H=460 mm
Weight without heating option 5.2 kg
Weight with heating option 5.6 kg
Attachment Female flange for tube dia. 50 mm
Protection rating IP54
3.3
ELECTRICAL DATA
Dry contact output 10 V AC/15 V DC, 250 mA
Pulse duration 50 to 200 ms
Power supply to heating option 24V AC/DC, 130W (6A)
Connection contact: 2 disconnectable screwed terminals for wires of cross-section up to 2.5 mm²
ground: 1 disconnectable screwed terminal for wires of cross-section up to 2.5 mm²
heating: 2 disconnectable screwed terminals for wires of cross-section up to 2.5 mm²
3.4
ENVIRONMENT, STANDARDS
Protection rating IP54
Operating temperature -20°C to 60°C (with heating option)
Storage temperature -20°C to 60°C
EC marking directives 2014/30/EU, 2014/35/EU and 2011/65/EU
RoHS compliant
4
OPERATION
The device include a collector with a ring surface area of 400 cm².
The precipitations collected are directed towards tipping trays, calibrated to measure the quantity of precipitation during a given
rainfall.
The incremental volume each time a tray tips is 0.2 litre/m² or 0.2mm of rain.
Every time a tray tips, a contact is actuated thus returning the measurement.
The version described in this manual is fitted with an automatic thermostatically-controlled heater (available as an option), for
operation with snow or ice.
This heating option requires a 130W 24 V AC or 24 V DC power supply (depending on model).