Partizan PAB-FC2 User manual


`
Partizan PAB-FC2
1. Features & Technical Parameters
1.1 Features:
●Metal vandalproof housing
●Secure and reliable biometric fingerprint recognition
●Simple for using, wiring can be done by a user without professional knowledge
●Luminous touch unlock button. Manually or automatically enter dormant state
●IR remote control or Master fingerprint for adding or deleting users
●Able to connect to all types of electric locks
●Able for using with all kinds of controllers
●Tampering alarm function
1.2 Technical Parameters:
Up to 1000
Number of users
450 Dpi
Resolution
<0.5 s
Fingerprint scan time
<0.5 s
Fingerprint identification
time
Wiegand 26
Output interface
<0.0000256%
FAR
<0.0198%
FRR
-20°C ~ +55°C
Operating temperature
IP55
Ingress protection rating
120x72x25 mm
Dimension
24 months
Warranty period
DC12V/1A
Power supply
2. Installation and Wiring Diagram
●Follow Pic.1 to draw the mounting and cable holes on the wall.
●Insert rubber bungs to the mounting holes and fix the back cover of the controller on the wall.
●Pull the cable through the cable hole of the back cover and connect it to the terminal block of the
controller.
●Fasten the front cover to the back side with anti-vandal screw as in Pic.1.
Note: 1. After connecting all the wires, please double check correct connection before power on.
2. The device uses optical fingerprint technology, so it's not recommended for installation under direct
sunlight, otherwise fingerprint identification will be abnormal.

`
Pic. 1 Device installation
Pic. 2 Principle of the electric lockconnection

`
Pic. 3 Wiring diagram
Pic. 4 Connection to the access controller (reader mode)
3. Master setting by IR remote control
Note that all the following settings should be done under Master programming mode.
If master PIN is wrong and time is over 5 seconds after PIN entering, the device will return to standby
mode. After the correct entering of master PIN, it will also return to standby mode after 30 seconds if
there is not any operation. Press “#” to confirm the inputted number, press “*” for return to the previous
menu, the light indicator will indicate the operation mode.
To enter the programming mode
Red
Red flash
Functions
Description
*
6-8 digit Master PIN
To enter the programming
mode
Default 888888

`
Access controller settings
Red flash
Orange
Functions
Description
0
6-8 digits of a new PIN, #, repeat 6-8
digits of a new PIN, #
To change Master PIN
1
1(ID), #, press Master fingerprint twice
Add 1 Master “add fingerprint”
“add fingerprint” –for
adding a user.
“delete fingerprint” – for
deleting a user.
2 (ID), #, press another Master
fingerprint twice
Add 1 Master “delete fingerprint”
Press user fingerprint twice
3-1000 (ID), #, press user fingerprint
twice
Add 1 user
2
Press user fingerprint once
Delete 1 user
1-1000 (ID), #
Delete 1 user
2
0000, #
Delete all users
3
0-250, #
Facility code
Default 0
4
0, #
Door relay time 50 ms
Default 5
1-98, #
Door relay time 1-98 s
99, #
Toggle mode
5
0, #
A type of lock connection (NO)
Default 1
1, #
B type of lock connection (NC)

`
4. Master fingerprint operation
To add users
Press Master Add fingerprint once, press user fingerprint twice, press Master Add fingerprint once to
complete.
To delete users
Press Master Delete fingerprint once, press user fingerprint once, press Master Delete fingerprint once to
complete.
5. User Operation
When the light indicator of fingerprint sensor is On, press a valid fingerprint once, the electrical lock will
be unlocked. When the device is in standby mode, light indicator of a fingerprint sensor will be Off, tap
the luminous touch button, the light will be on, if you press again, the light will be off. After 15 seconds
of inactivity, the light of a fingerprint sensor will be off automatically - standby mode.
6. Alarm
When the device is disassembled illegally, the device will sound an alarm within 1 minute.
Press Master fingerprint or PIN to cancel alarm otherwise the alarm will stop automatically after 1
minute.
7. Reset to factory settings
If you need to connect an exit button, switch power off, press an exit button and switch power on, after
that the LED turns into ORANGE after 1 second, hold the button until you hear “2 beeps”, after you hear
“Long beep” and the LED turns into RED, it means the device was successfully reset to factory settings.
Reset to factory settings will not erase all user information.
8. Sound and light indication
Operation status
LED color
Sound indication
Stand by
Red
Pressing
Beep
Unlocking
Green
Long beep
Successful
Green
Long beep
Error
Triple beep
Programming mode
Slow Red flash
Enter settings
Orange
Alarm
Quick Red flash
Alarm sound

`
9. Reader mode
Before using the device, you need to add user fingerprints, set door relay timer and facility code.
Device format data output - Wiegand 26. It's a virtual card number which consists of facility code (0-255)
and fingerprint ID (3-1000).
For example: facility code is set 255, fingerprint ID is 3, then output virtual card number 255, 00003. It's
convenient to manage fingerprint database.
Device output protocol –Wiegand 26. Output data is transmitted by the Low level of D0 & D1 wire:
D0: Low level means 0, green wire
D1: Low level means 1, white wire
The pulse width for Low level is 40 ms; and the time interval is 2 ms.