WARNING
For your protection please read the following:
Water and moisture: Electrical devices should not be used near water ( as per example,
near a bathtub, washbasin, kitchen sink, laundry tub, wet basement or swimming pool ).
Care should be taken such that objects do not have the opportunity to fall, and that liquid
is never spilled onto or into the device enclosure through openings.
Power Sources: An electrical device must be connected to a mains power source in strict
accordance with the supplied product owners manual. Please verify that the AC mains
voltage specified in the product manual matches those requirements indicated on the unit
and the AC voltage provided to your location by the power company.
Grounding: Adequate precautions should be taken so that the grounding provisions built
into an electrical product are never defeated.
Power Cords: Pass Labs provides a power supply cord that meets all legislated
requirements for the market in which the product was originally sold. If you choose to
substitute an after-market product we urge you to choose one that is fully safety rated by
the necessary local authority.
Power Cord Protection: Power supply cords should be routed so that they are not likely
to be walked on, abraded, or pinched by items placed on or against them, paying particular
attention to cords where they enter plugs or exit from a device. Never under any
circumstance insert a cut or damaged power cord into a mains power socket.
Power and Signal: Cables should never be connected / disconnected with equipment
powered up. Failure to heed this warning may damage or destroy equipment.
Ventilation: Power-amplifiers run hot, but you should be able to place your hands on
them without discomfort. You must allow for this heat in installation, by providing for
free air circulation around the product. Electronics should not be subjected to sources of
excessive radiant heat. Excessive heat can shorten the life of the product and may cause
the electronics to self protect and shut down.
Servicing: To reduce the risk of fire, electrical shock or other injuries, the user should not
attempt to service the device beyond that which is described in the operating instructions.
All other servicing must be referred to qualified service personnel.
For Units With Externally Accessible Fuse Receptacle: Unplug the device from all
sources of power before changing or inspecting any fuse. Replace fuse with one of same
physical size, type and rating as that specified by the manufacturer for that product.
Quick Setup:
Unpacking your INT-60
The INT-60 is heavy - please make sure you have help to remove the INT-60 from the packing
and to place the amp where you want it.
Included in the box are a remote control and a power cord. You will need these so don’t throw
them away with the empty box. In fact you should keep the empty box as well.
Place the amplifier close to where you intend to use it. Just leave enough access so you can
connect the inputs and speaker cables.
Plug in the amp into the AC. Turn on the AC power switch. At this point you should have the
blue LED in the center of the meter on. Push the “power” button on the faceplate a few times.
The amp should cycle on and off (display and meter lights will come on and go off).
Turn the amp “off ” from the faceplate. Now you should be ready to connect your sources and
speakers.
Quick Connections:
Connect your sources to the inputs. There are four inputs, two with XLR and RCA and two
with RCA only. The XLR and RCA inputs on INPUT 1 (and INPUT 2) are connected so use
XLR or RCA but not both. When using INPUT 1 & 2 with RCAs you should have the XLR
shorting jumpers in place.
The Preamp Outputs can be used to drive a second system, a subwoofer or other amplifiers
for bi-amping. These output are live when the amp is live and MUTED when the amp is
MUTED.
The speaker binding posts can accept spades, banana plugs or bare wire. They also have a built
in torque limiting ratchet system to prevent over tightening and damage to the binding posts.

2 3
WARNING
For your protection please read the following:
Water and moisture: Electrical devices should not be used near water ( as per example,
near a bathtub, washbasin, kitchen sink, laundry tub, wet basement or swimming pool ).
Care should be taken such that objects do not have the opportunity to fall, and that liquid
is never spilled onto or into the device enclosure through openings.
Power Sources: An electrical device must be connected to a mains power source in strict
accordance with the supplied product owners manual. Please verify that the AC mains
voltage specified in the product manual matches those requirements indicated on the unit
and the AC voltage provided to your location by the power company.
Grounding: Adequate precautions should be taken so that the grounding provisions built
into an electrical product are never defeated.
Power Cords: Pass Labs provides a power supply cord that meets all legislated
requirements for the market in which the product was originally sold. If you choose to
substitute an after-market product we urge you to choose one that is fully safety rated by
the necessary local authority.
Power Cord Protection: Power supply cords should be routed so that they are not likely
to be walked on, abraded, or pinched by items placed on or against them, paying particular
attention to cords where they enter plugs or exit from a device. Never under any
circumstance insert a cut or damaged power cord into a mains power socket.
Power and Signal: Cables should never be connected / disconnected with equipment
powered up. Failure to heed this warning may damage or destroy equipment.
Ventilation: Power-amplifiers run hot, but you should be able to place your hands on
them without discomfort. You must allow for this heat in installation, by providing for
free air circulation around the product. Electronics should not be subjected to sources of
excessive radiant heat. Excessive heat can shorten the life of the product and may cause
the electronics to self protect and shut down.
Servicing: To reduce the risk of fire, electrical shock or other injuries, the user should not
attempt to service the device beyond that which is described in the operating instructions.
All other servicing must be referred to qualified service personnel.
For Units With Externally Accessible Fuse Receptacle: Unplug the device from all
sources of power before changing or inspecting any fuse. Replace fuse with one of same
physical size, type and rating as that specified by the manufacturer for that product.
Quick Setup:
Unpacking your INT-60
The INT-60 is heavy - please make sure you have help to remove the INT-60 from the packing
and to place the amp where you want it.
Included in the box are a remote control and a power cord. You will need these so don’t throw
them away with the empty box. In fact you should keep the empty box as well.
Place the amplifier close to where you intend to use it. Just leave enough access so you can
connect the inputs and speaker cables.
Plug in the amp into the AC. Turn on the AC power switch. At this point you should have the
blue LED in the center of the meter on. Push the “power” button on the faceplate a few times.
The amp should cycle on and off (display and meter lights will come on and go off).
Turn the amp “off ” from the faceplate. Now you should be ready to connect your sources and
speakers.
Quick Connections:
Connect your sources to the inputs. There are four inputs, two with XLR and RCA and two
with RCA only. The XLR and RCA inputs on INPUT 1 (and INPUT 2) are connected so use
XLR or RCA but not both. When using INPUT 1 & 2 with RCAs you should have the XLR
shorting jumpers in place.
The Preamp Outputs can be used to drive a second system, a subwoofer or other amplifiers
for bi-amping. These output are live when the amp is live and MUTED when the amp is
MUTED.
The speaker binding posts can accept spades, banana plugs or bare wire. They also have a built
in torque limiting ratchet system to prevent over tightening and damage to the binding posts.

4 5
POWER MUTE
INPUT1 INPUT2 INPUT3 INPUT4
INT-60
Preamp Output
L
R R
L
Preamp Inputs
1234 RightRight Left LeftLeftRight
Left
Right Jumper must be used
with single-ended input
No user serviceable parts inside.
3
12
Signal Gnd
Pass Laboratories, Auburn, CA 95602 ~ AC Mains
1. Standby Power button 2. Display - shows level 3. Input buttons (1 thru 4)
4. Input LED indicators 5. Meter 6. IR Window
7. Volume control 8. Mute LED indicator 9. Mute button
1. Right Speaker Connection2. Preamp outputs (RCA & XLR) 3. AC Power Switch
4. AC Mains Inlet. 5. Fuse (see voltage label for details)6. Preamp inputs (RCA & XLR)
7. Signal Ground 8. Left Speaker Connection
1
2
34
5
69
78
1
2
3
45
6
7 8
volume
displayext amp on
pass thru
balance
tape
3
mute
54
21
power
PASS
Remote functions:
power:
mute: Mutes the output of the amplifier and
preamp
1,2,3,4: Direct input selection
volume: adjusts the output level
Basic Operations:
Power on / Off:
Once the INT-60 is turned on from the rear power switch, the
INT-60 can switch in to stand by mode from the front panel
power switch or the power button on the remote. In Stand By the
INT-60 draws less than 0.5 watts.
Front Display & Meter:
The LED display show volume level in one dB steps, from 0 to 63. The meter operates
slightly different from our amplifiers in that this meter doesn’t show bias but output
voltage.
Input selection:
The inputs can be selected by the four buttons on the face plate or the input buttons (1-4)
on the remote.
Volume control:
The volume level can be set by using the volume control knob on the face plate of the
volume buttons on the remote
Mute:
The INT-60 can be muted from the front panel or remote. When in MUTE the display
shows “00” and the LED above the MUTE button on the faceplate will be on.

4 5
POWER MUTE
INPUT1 INPUT2 INPUT3 INPUT4
INT-60
Preamp Output
L
R R
L
Preamp Inputs
1234 RightRight Left LeftLeftRight
Left
Right Jumper must be used
with single-ended input
No user serviceable parts inside.
3
12
Signal Gnd
Pass Laboratories, Auburn, CA 95602 ~ AC Mains
1. Standby Power button 2. Display - shows level 3. Input buttons (1 thru 4)
4. Input LED indicators 5. Meter 6. IR Window
7. Volume control 8. Mute LED indicator 9. Mute button
1. Right Speaker Connection2. Preamp outputs (RCA & XLR) 3. AC Power Switch
4. AC Mains Inlet. 5. Fuse (see voltage label for details)6. Preamp inputs (RCA & XLR)
7. Signal Ground 8. Left Speaker Connection
1
2
34
5
69
78
1
2
3
45
6
7 8
volume
displayext amp on
pass thru
balance
tape
3
mute
54
21
power
PASS
Remote functions:
power:
mute: Mutes the output of the amplifier and
preamp
1,2,3,4: Direct input selection
volume: adjusts the output level
Basic Operations:
Power on / Off:
Once the INT-60 is turned on from the rear power switch, the
INT-60 can switch in to stand by mode from the front panel
power switch or the power button on the remote. In Stand By the
INT-60 draws less than 0.5 watts.
Front Display & Meter:
The LED display show volume level in one dB steps, from 0 to 63. The meter operates
slightly different from our amplifiers in that this meter doesn’t show bias but output
voltage.
Input selection:
The inputs can be selected by the four buttons on the face plate or the input buttons (1-4)
on the remote.
Volume control:
The volume level can be set by using the volume control knob on the face plate of the
volume buttons on the remote
Mute:
The INT-60 can be muted from the front panel or remote. When in MUTE the display
shows “00” and the LED above the MUTE button on the faceplate will be on.

6 7
Warranty:
Please check with the factory authorized distributor in the country where you are purchasing
this product for specific warranty information.
All Pass Laboratories products purchased new from an authorized Pass Laboratories dealer in
North America are covered by a transferable, limited 3-year warranty. This warranty includes
all parts and labor charges incurred at the factory or factory specified repair facility, exclusive
of any subsequent or consequential damages. Damage due to physical abuse is specifically
excluded under this warranty.
For this warranty to apply the customer is responsible for returning the product unmodified to
the factory within the specified warranty period. The customer assumes all responsibility for
shipping and insurance to and from the factory or a factory specified repair facility. The
conditions and stipulations of this Pass Laboratories warranty only applies to units originally
sold new through an authorized dealer. Warranty on factory repair is 60 days and covers only
the scope of the original repair.
Non-North America customers should consult with their original Pass Labs dealer or
distributor for warranty repair instruction prior to contacting the factory or shipping product
to the factory for repair.
Non-North American product must be returned to the country of origin for warranty service.
Foreign distributors are only required to offer warranty service on Pass Laboratories product
that they have imported, verifiable by serial number.
Please note: Conditions of warranty service and customer rights for product purchased
outside the United States may vary depending upon the distributor and local laws. Please check
with your local distributor for specific rights and details.
Any modifications to Pass Laboratories products that have not received written factory
approval nullify all claims and void all provisions of the warranty and liability by the maker or
authorized distributor. Should a modified product be returned to the factory for repair the
owner will be required to pay all necessary charges for the repair in addition to those charges
required to return the product to it's original configuration.
In the case of safety issues, no product shall be returned to the customer without those safety
issues being corrected to the most recent accepted standards.
Removal or alteration of original Pass Labs serial numbers voids the factory warranty. Product
with altered or missing serial numbers will be suspect as counterfeit or stolen product.
Pass Laboratories will not repair or in any way indemnify any counterfeit or cloned product.
Pass Laboratories does not offer products in voltages intended for international markets
either to authorized Pass Labs dealers or to third parties located in the United States or
Canada.
Pass Laboratories, 13395 New Airport Rd., Suite G., Auburn, CA 95602
Phone: 530.878.5350, Fax: 530.878.5358, Web: www.passlabs.com

6 7
Warranty:
Please check with the factory authorized distributor in the country where you are purchasing
this product for specific warranty information.
All Pass Laboratories products purchased new from an authorized Pass Laboratories dealer in
North America are covered by a transferable, limited 3-year warranty. This warranty includes
all parts and labor charges incurred at the factory or factory specified repair facility, exclusive
of any subsequent or consequential damages. Damage due to physical abuse is specifically
excluded under this warranty.
For this warranty to apply the customer is responsible for returning the product unmodified to
the factory within the specified warranty period. The customer assumes all responsibility for
shipping and insurance to and from the factory or a factory specified repair facility. The
conditions and stipulations of this Pass Laboratories warranty only applies to units originally
sold new through an authorized dealer. Warranty on factory repair is 60 days and covers only
the scope of the original repair.
Non-North America customers should consult with their original Pass Labs dealer or
distributor for warranty repair instruction prior to contacting the factory or shipping product
to the factory for repair.
Non-North American product must be returned to the country of origin for warranty service.
Foreign distributors are only required to offer warranty service on Pass Laboratories product
that they have imported, verifiable by serial number.
Please note: Conditions of warranty service and customer rights for product purchased
outside the United States may vary depending upon the distributor and local laws. Please check
with your local distributor for specific rights and details.
Any modifications to Pass Laboratories products that have not received written factory
approval nullify all claims and void all provisions of the warranty and liability by the maker or
authorized distributor. Should a modified product be returned to the factory for repair the
owner will be required to pay all necessary charges for the repair in addition to those charges
required to return the product to it's original configuration.
In the case of safety issues, no product shall be returned to the customer without those safety
issues being corrected to the most recent accepted standards.
Removal or alteration of original Pass Labs serial numbers voids the factory warranty. Product
with altered or missing serial numbers will be suspect as counterfeit or stolen product.
Pass Laboratories will not repair or in any way indemnify any counterfeit or cloned product.
Pass Laboratories does not offer products in voltages intended for international markets
either to authorized Pass Labs dealers or to third parties located in the United States or
Canada.
Pass Laboratories, 13395 New Airport Rd., Suite G., Auburn, CA 95602
Phone: 530.878.5350, Fax: 530.878.5358, Web: www.passlabs.com
Other manuals for INT-60
1
Table of contents
Other Pass Amplifier manuals
Popular Amplifier manuals by other brands

Onkyo
Onkyo AS-V640 instruction manual

Rockford Fosgate
Rockford Fosgate T400-2 Installation and operation

Link electronics
Link electronics 200 Series Mounting Frame Audio and Video DA's... Specifications

Bosch
Bosch rexroth VT-MSPA2-2X/A5/1A5/000 operating instructions

AUDIO TELEX
AUDIO TELEX IC30 operating instructions

Hafler
Hafler DH-220 instructions