Model 113A36
High freq. Invar ICP® pressure probe, 500 psi, 10 mV/psi, 0.218"" dia.
Installation and Operating Manual
For assistance with the operation of this product,
contact PCB Piezotronics, Inc.
Toll-free: 800-828-8840
24-hour SensorLine: 716-684-0001
Fax: 716-684-0987
E-mail: [email protected]
Web: www.pcb.com
The information contained in this document supersedes all similar information that
may be found elsewhere in this manual.
Total Customer Satisfaction – PCB
Piezotronics guarantees Total Customer
Satisfaction. If, at any time, for any
reason, you are not completely satisfied
with any PCB product, PCB will repair,
replace, or exchange it at no charge. You
may also choose to have your purchase
price refunded in lieu of the repair,
replacement, or exchange of the product.
Service – Due to the sophisticated nature
of the sensors and associated
instrumentation provided by PCB
Piezotronics, user servicing or repair is
not recommended and, if attempted, may
void the factory warranty. Routine
maintenance, such as the cleaning of
electrical connectors, housings, and
mounting surfaces with solutions and
techniques that will not harm the
physical material of construction, is
acceptable. Caution should be observed
to insure that liquids are not permitted to
migrate into devices that are not
hermetically sealed. Such devices should
only be wiped with a dampened cloth
and never submerged or have liquids
poured upon them.
Repair – In the event that equipment
becomes damaged or ceases to operate,
arrangements should be made to return
the equipment to PCB Piezotronics for
repair. User servicing or repair is not
recommended and, if attempted, may
void the factory warranty.
Calibration – Routine calibration of
sensors and associated instrumentation is
recommended as this helps build
confidence in measurement accuracy and
acquired data. Equipment calibration
cycles are typically established by the
users own quality regimen. When in
doubt about a calibration cycle, a good
“rule of thumb” is to recalibrate on an
annual basis. It is also good practice to
recalibrate after exposure to any severe
temperature extreme, shock, load, or
other environmental influence, or prior
to any critical test.
PCB Piezotronics maintains an ISO-
9001 certified metrology laboratory and
offers calibration services, which are
accredited by A2LA to ISO/IEC 17025,
with full traceablility to N.I.S.T. In
addition to the normally supplied
calibration, special testing is also
available, such as: sensitivity at elevated
or cryogenic temperatures, phase
response, extended high or low
frequency response, extended range, leak
testing, hydrostatic pressure testing, and
others. For information on standard
recalibration services or special testing,
contact your local PCB Piezotronics
distributor, sales representative, or
factory customer service representative.
Returning Equipment – Following
these procedures will insure that your
returned materials are handled in the
most expedient manner. Before returning
any equipment to PCB Piezotronics,
contact your local distributor, sales
representative, or factory customer
service representative to obtain a Return
Warranty, Service, Repair, and
Return Policies and Instructions
Materials Authorization (RMA)
Number. This RMA number should be
clearly marked on the outside of all
package(s) and on the packing list(s)
accompanying the shipment. A detailed
account of the nature of the problem(s)
being experienced with the equipment
should also be included inside the
package(s) containing any returned
materials.
A Purchase Order, included with the
returned materials, will expedite the
turn-around of serviced equipment. It is
recommended to include authorization
on the Purchase Order for PCB to
proceed with any repairs, as long as they
do not exceed 50% of the replacement
cost of the returned item(s). PCB will
provide a price quotation or replacement
recommendation for any item whose
repair costs would exceed 50% of
replacement cost, or any item that is not
economically feasible to repair. For
routine calibration services, the Purchase
Order should include authorization to
proceed and return at current pricing,
which can be obtained from a factory
customer service representative.
Warranty – All equipment and repair
services provided by PCB Piezotronics,
Inc. are covered by a limited warranty
against defective material and
workmanship for a period of one year
from date of original purchase. Contact
PCB for a complete statement of our
warranty. Expendable items, such as
batteries and mounting hardware, are not
covered by warranty. Mechanical
damage to equipment due to improper
use is not covered by warranty.
Electronic circuitry failure caused by the
introduction of unregulated or improper
excitation power or electrostatic
discharge is not covered by warranty.
Contact Information – International
customers should direct all inquiries to
their local distributor or sales office. A
complete list of distributors and offices
can be found at www.pcb.com.
Customers within the United States may
contact their local sales representative or
a factory customer service
representative. A complete list of sales
representatives can be found at
www.pcb.com. Toll-free telephone
numbers for a factory customer service
representative, in the division
responsible for this product, can be
found on the title page at the front of this
manual. Our ship to address and general
contact numbers are:
PCB Piezotronics, Inc.
3425 Walden Ave.
Depew, NY 14043 USA
Toll-free: (800) 828-8840
24-hour SensorLineSM: (716) 684-0001
Website: www.pcb.com
E-mail: [email protected]
DOCUMENT NUMBER: 21354
DOCUMENT REVISION: B
ECN: 17900
Model Number
113A36
PRESSURE SENSOR, ICP®Revision G
ECN #: 40791
Performance ENGLISH SI
Measurement Range (for ±5V output) 500 psi 3448 kPa
Useful Overrange (for ± 10V output) 1 kpsi 6895 kPa [1]
Sensitivity (±0.5 mV/psi) 10.0 mV/psi 1.45 mV/kPa
Maximum Pressure 10 kpsi 68950 kPa
Resolution 10 mpsi 0.069 kPa
Resonant Frequency ≥400 kHz ≥400 kHz
Rise Time (Reflected) ≤1.5 µ sec ≤1.5 µ sec
Low Frequency Response (-5 %) 0.01 Hz 0.01 Hz
Non-Linearity ≤1.0 % FS ≤1.0 % FS [2]
Environmental
Acceleration Sensitivity ≤0.002 psi/g ≤0.0014 kPa/(m/s²)
Temperature Range (Operating) -100 to +275 °F -73 to +135 °C
Temperature Coefficient of Sensitivity ≤0.1 %/°F ≤0.18 %/°C
Maximum Flash Temperature 3000 °F 1650 °C
Maximum Vibration 2000 g pk 19614 m/s² pk
Maximum Shock 20000 g pk 196140 m/s² pk
Electrical
Output Polarity (Positive Pressure) Positive Positive
Discharge Time Constant (at room temp) ≥50 sec ≥50 sec
Excitation Voltage 20 to 30 VDC 20 to 30 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance <100 Ohm <100 Ohm
Output Bias Voltage 8 to 14 VDC 8 to 14 VDC
Physical
Sensing Geometry Compression Compression
Sensing Element Quartz Quartz
Housing Material Invar Invar
Diaphragm Invar Invar
Sealing Welded Hermetic Welded Hermetic
Electrical Connector 10-32 Coaxial Jack 10-32 Coaxial Jack
Weight 0.2 oz 6.0 gm
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without
notice.
ICP® is a registered trademark of PCB group, Inc.
Optional Versions (Optional versions have identical specifications and accessories as listed
for standard model except where noted below. More than one option maybe used.)
E- Emralon coating
Coating Emralon Emralon
Electrical Isolation 108 Ohm 108 Ohm
Supplied Accessory: Model 065A08 Isolation ring, 0.250" OD x 0.218" ID x 0.027" thk,
anodized aluminum
Supplied Accessory: Model 065A22 Isolation Seal, .250" OD x .218" ID x .015", Torlon
or Vespel
H- Hermetic Seal
J- Ground Isolated
M- Metric Mount
Supplied Accessory: Model 060A05 Clamp nut, M7 x 0.75-6G thd (for Series M111,
M112 and M113)
Notes
[1] For +10 volt output, minimum 24 VDC supply voltage required. Negative 10 volt
output may be limited by output bias.
[2] Zero-based, least-squares, straight line method.
[3] See PCB Declaration of Conformance PS023 for details.
Supplied Accessories
060A03 Clamp nut, 5/16-24-2A thd, 1/4" hex, stainless steel (1)
065A02 Seal ring, sensor flush mount, 0.248" OD x 0.219" ID x 0.015" thk, brass (3)
065A05 Seal sleeve sensor recess mount 0.248" OD x 0.221" ID x 0.240" thk 17-4 (1)
Entered: AP Engineer: MJK Sales: KWW Approved: BAM Spec Number:
Date:
03/19/2013 Date:
03/19/2013 Date:
03/19/2013 Date:
03/19/2013 1817
3425 Walden Avenue
Depew, NY 14043
UNITED STATES
Phone: 800-828-8840
Fax: 716-684-0987
E-mail: [email protected]
Web site: www.pcb.com

This manual suits for next models

31

Other PCB Piezotronics Measuring Instrument manuals

PCB Piezotronics 352C22 User manual

PCB Piezotronics

PCB Piezotronics 352C22 User manual

PCB Piezotronics IMI SENSORS Spindler 607A60 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS Spindler 607A60 User manual

PCB Piezotronics TLD356A32 User manual

PCB Piezotronics

PCB Piezotronics TLD356A32 User manual

PCB Piezotronics JM352C18 User manual

PCB Piezotronics

PCB Piezotronics JM352C18 User manual

PCB Piezotronics 3741F12200G User manual

PCB Piezotronics

PCB Piezotronics 3741F12200G User manual

PCB Piezotronics 352C34 User manual

PCB Piezotronics

PCB Piezotronics 352C34 User manual

PCB Piezotronics 3741E1250G User manual

PCB Piezotronics

PCB Piezotronics 3741E1250G User manual

PCB Piezotronics IMI SENSORS 646B02 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 646B02 User manual

PCB Piezotronics J320C04 User manual

PCB Piezotronics

PCB Piezotronics J320C04 User manual

PCB Piezotronics IMI SENSORS ICP M628F01 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS ICP M628F01 User manual

PCB Piezotronics IMI SENSORS ICP 607A01 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS ICP 607A01 User manual

PCB Piezotronics ICP 602D11 User manual

PCB Piezotronics

PCB Piezotronics ICP 602D11 User manual

PCB Piezotronics 351B14 User manual

PCB Piezotronics

PCB Piezotronics 351B14 User manual

PCB Piezotronics IMI SENSORS 66392CPZ1 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 66392CPZ1 User manual

PCB Piezotronics JP357B33 User manual

PCB Piezotronics

PCB Piezotronics JP357B33 User manual

PCB Piezotronics J357B03 User manual

PCB Piezotronics

PCB Piezotronics J357B03 User manual

PCB Piezotronics IMI SENSORS M645B01 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS M645B01 User manual

PCB Piezotronics 3741B12100G User manual

PCB Piezotronics

PCB Piezotronics 3741B12100G User manual

PCB Piezotronics IMI SENSORS M602D61 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS M602D61 User manual

PCB Piezotronics 352A74 User manual

PCB Piezotronics

PCB Piezotronics 352A74 User manual

PCB Piezotronics 350B01 User manual

PCB Piezotronics

PCB Piezotronics 350B01 User manual

PCB Piezotronics 034T20 User manual

PCB Piezotronics

PCB Piezotronics 034T20 User manual

PCB Piezotronics 3501A202KG User manual

PCB Piezotronics

PCB Piezotronics 3501A202KG User manual

PCB Piezotronics 3743F1110G User manual

PCB Piezotronics

PCB Piezotronics 3743F1110G User manual

Popular Measuring Instrument manuals by other brands

BW Technologies GasAlertMicro5 Quick reference guide

BW Technologies

BW Technologies GasAlertMicro5 Quick reference guide

Barnett Engineering ProTalk Cv3 Installation & operation manual

Barnett Engineering

Barnett Engineering ProTalk Cv3 Installation & operation manual

Oval ALTI mass CA00A instructions

Oval

Oval ALTI mass CA00A instructions

Velleman DVM322DI manual

Velleman

Velleman DVM322DI manual

AUTOUTLET EFU008 user manual

AUTOUTLET

AUTOUTLET EFU008 user manual

Trotec BL30 quick start guide

Trotec

Trotec BL30 quick start guide

PRESIDIUM PEGG User handbook

PRESIDIUM

PRESIDIUM PEGG User handbook

Molecular Devices MiniDigi Setup guide

Molecular Devices

Molecular Devices MiniDigi Setup guide

PCE Instruments PCE-AQD 20 user manual

PCE Instruments

PCE Instruments PCE-AQD 20 user manual

KMT MTP-NT user manual

KMT

KMT MTP-NT user manual

Megger DCM340 user guide

Megger

Megger DCM340 user guide

Sartorius MA37 operating instructions

Sartorius

Sartorius MA37 operating instructions

Parkside PKLL 8 A2 Translation of the original instructions

Parkside

Parkside PKLL 8 A2 Translation of the original instructions

Agrosta NEMESIS quick start guide

Agrosta

Agrosta NEMESIS quick start guide

Hach Intellical MTC30101 User instructions

Hach

Hach Intellical MTC30101 User instructions

Tektronix WVR7200 Service manual

Tektronix

Tektronix WVR7200 Service manual

Reely RE-5631039 operating instructions

Reely

Reely RE-5631039 operating instructions

horiba 3551-10D instruction manual

horiba

horiba 3551-10D instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.