manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PCB Piezotronics
  6. •
  7. Measuring Instrument
  8. •
  9. PCB Piezotronics J356A03/NC User manual

PCB Piezotronics J356A03/NC User manual

Model J356A03/NC
Triaxial, lightweight miniature, ceramic shear ICP® accel., 10 mV/g, 0.25" cube, ground isolated
no extension cable provided
Installation and Operating Manual
For assistance with the operation of this product,
contact the PCB Piezotronics, Inc.
Toll-free: 716-684-0001
24-hour SensorLine: 716-684-0001
Fax: 716-684-0987
E-mail: [email protected]
Web: www.pcb.com
Manual 21354 Rev E
ECN 50523
Repair and Maintenance
PCB guarantees Total Customer Satisfaction through its
“Lifetime Warranty Plus” on all Platinum Stock Products
sold by PCB and through its limited warranties on all other
PCB Stock, Standard and Special products. Due to the
sophisticated nature of our sensors and associated
instrumentation, field servicing and repair is not
recommended and, if attempted, will void the factory
warranty.
Beyond routine calibration and battery replacements
where applicable, our products require no user
maintenance. Clean electrical connectors, housings, and
mounting surfaces with solutions and techniques that will
not harm the material of construction. Observe caution
when using liquids near devices that are not hermetically
sealed. Such devices should only be wiped with a
dampened cloth—never saturated or submerged.
In the event that equipment becomes damaged or ceases
to operate, our Application Engineers are here to support
your troubleshooting efforts 24 hours a day, 7 days a
week. Call or email with model and serial number as well
as a brief description of the problem.
Calibration
Routine calibration of sensors and associated
instrumentation is necessary to maintain measurement
accuracy. We recommend calibrating on an annual basis,
after exposure to any extreme environmental influence,
or prior to any critical test.
PCB Piezotronics is an ISO-9001 certified company whose
calibration services are accredited by A2LA to ISO/IEC
17025, with full traceability to SI through N.I.S.T. In
addition to our standard calibration services, we also offer
specialized tests, including: sensitivity at elevated or
cryogenic temperatures, phase response, extended high
or low frequency response, extended range, leak testing,
hydrostatic pressure testing, and others. For more
information, contact your local PCB Piezotronics
distributor, sales representative, or factory customer
service representative.
Returning Equipment
If factory repair is required, our representatives will
provide you with a Return Material Authorization (RMA)
number, which we use to reference any information you
have already provided and expedite the repair process.
This number should be clearly marked on the outside of
all returned package(s) and on any packing list(s)
accompanying the shipment.
Contact Information
PCB Piezotronics, Inc.
3425 Walden Ave.
Depew, NY14043 USA
Toll-free: (800) 828-8840
24-hour SensorLine: (716) 684-0001
General inquiries: in[email protected]
Repair inquiries: rma@pcb.com
For a complete list of distributors, global offices and sales
representatives, visit our website, www.pcb.com.
Safety Considerations
This product is intended for use by qualified personnel
who recognize shock hazards and are familiar with the
precautions required to avoid injury. While our equipment
is designed with user safety in mind, the protection
provided by the equipment may be impaired if equipment
is used in a manner not specified by this manual.
Discontinue use and contact our 24-Hour Sensorline if:
Assistance is needed to safely operate equipment
Damage is visible or suspected
Equipment fails or malfunctions
For complete equipment ratings, refer to the enclosed
specification sheet for your product.
Definition of Terms and Symbols
The following symbols may be used in this manual:
DANGER
Indicates an immediate hazardous
situation, which, if not avoided, may
result in death or serious injury.
Manual 21354 Rev E
ECN 50523
CAUTION
Refers to hazards that could damage
the instrument.
NOTE
Indicates tips, recommendations and
important information. The notes
simplify processes and contain
additional information on particular
operating steps.
The following symbols may be found on the equipment
described in this manual:
This symbol on the unit indicates that
high voltage may be present. Use
standard safety precautions to avoid
personal contact with this voltage.
This symbol on the unit indicates that
the user should refer to the operating
instructions located in the manual.
This symbol indicates safety, earth
ground.
Manual 21354 Rev E
ECN 50523
PCB工业监视和测量设备 - 中国RoHS2公布表
PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table
部件名称
有害物质
铅(Pb)
汞
(Hg)
镉
(Cd)
六价铬(Cr(VI))
多溴联苯 (PBB)
多溴二苯醚(PBDE)
住房
O
O
O
O
O
O
PCB板
X
O
O
O
O
O
电气连接器
O
O
O
O
O
O
压电晶体
X
O
O
O
O
O
环氧
O
O
O
O
O
O
铁氟龙
O
O
O
O
O
O
电子
O
O
O
O
O
O
厚膜基板
O
O
X
O
O
O
电线
O
O
O
O
O
O
电缆
X
O
O
O
O
O
塑料
O
O
O
O
O
O
焊接
X
O
O
O
O
O
铜合金/黄铜
X
O
O
O
O
O
本表格依据 SJ/T 11364 的规定编制。
O:表示该有害物质在该部件所有均质材料中的含量均在 GB/T 26572 规定的限量要求以下。
X:表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572 规定的限量要求。
铅是欧洲RoHS指令2011/65/ EU附件三和附件四目前由于允许的豁免。
CHINA RoHS COMPLIANCE
Manual 21354 Rev E
ECN 50523
Component Name
Hazardous Substances
Lead (Pb)
Mercury (Hg)
Cadmium (Cd)
Chromium VI
Compounds
(Cr(VI))
Polybrominated
Biphenyls (PBB)
Polybrominated
Diphenyl Ethers
(PBDE)
Housing
O
O
O
O
O
O
PCB Board
X
O
O
O
O
O
Electrical Connectors
O
O
O
O
O
O
Piezoelectric Crystals
X
O
O
O
O
O
Epoxy
O
O
O
O
O
O
Teflon
O
O
O
O
O
O
Electronics
O
O
O
O
O
O
Thick Film Substrate
O
O
X
O
O
O
Wires
O
O
O
O
O
O
Cables
X
O
O
O
O
O
Plastic
O
O
O
O
O
O
Solder
X
O
O
O
O
O
Copper Alloy/Brass
X
O
O
O
O
O
This table is prepared in accordance with the provisions of SJ/T 11364.
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit
requirement of GB/T 26572.
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit
requirement of GB/T 26572.
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU.
Model Number
356A03 TRIAXIAL ICP® ACCELEROMETER Revision: J
ECN #: 53458
Performance EN GLISH SI
Sensitivity(± 20 %) 10 mV/g 1.02 mV/(m/s²)
Measurement Range ± 500 g pk ± 4,905 m/s² pk
Frequency Range(± 5 %)(y or z axis) 2 to 8,000 Hz 2 to 8,000 Hz
Frequency Range(± 5 %)(x axis) 2 to 5,000 Hz 2 to 5,000 Hz
Frequency Range(+ 1 dB)(x axis) ≥ 8 kHz ≥ 8 kHz
Resonant Frequency ≥ 50 kHz ≥ 50 kHz
Broadband Resolution(1 to 10,000 Hz) 0.003 g rms 0.03 m/s² rms [1]
Non-Linearity ≤ 1 % ≤ 1 % [2]
Transverse Sensitivity ≤ 5 % ≤ 5 %
Environmen tal
Overload Limit(Shock) ± 5,000 g pk ± 49,050 m/s² pk
Temperature Range(Operating) -65 to +250 °F -54 to +121 °C
Temperature Response See Graph See Graph [1]
Electrical
Excitation Voltage 22 to 30 VDC 22 to 30 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance ≤ 200 Ohm ≤ 200 Ohm
Output Bias Voltage 9 to 16 VDC 9 to 16 VDC
Discharge Time Constant 0.24 to 1.0 sec 0.24 to 1.0 sec
Settling Time(within 10% of bias) < 3 sec < 3 sec
Spectral Noise(1 Hz) 1,200 µg/√Hz 11,772 (µm/sec2)/√Hz [1]
Spectral Noise(10 Hz) 300 µg/√Hz 2,943 (µm/sec2)/√Hz [1]
Spectral Noise(100 Hz) 100 µg/√Hz 981 (µm/sec2)/√Hz [1]
Spectral Noise(1 kHz) 30 µg/√Hz 294 (µm/sec2)/√Hz [1]
Ph ysical
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Titanium Titanium
Sealing Hermetic Hermetic
Size (Height x Length x Width) 0.25 in x 0.25 in x 0.25 in 6.35 mm x 6.35 mm x 6.35
mm
Weight(without cable) 0.04 oz 1.0 gm [1]
Electrical Connector Integral Cable Integral Cable
Electrical Connection Position Side Side
Cable Termination 1/4-28 4-Pin Jack 1/4-28 4-Pin Jack
Cable Length 5 ft 1.5 m
Cable Type 034 4-cond Shielded 034 4-cond Shielded
Mounting Adhesive Adhesive
[3]
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP® is a registered trademark of PCB Piezotronics, Inc.
J - Ground Isolated
Electrical Isolation(Base) > 108 Ohm > 108 Ohm
Size - Height .28 in 7.10 mm
Size - Length .28 in 7.10 mm
Size - Width .28 in 7.10 mm
Weight .04 oz 1.2 gm
TLD - TEDS Capable of Digital Memory and
Communication Compliant with IEEE 1451.4
Excitation Voltage 23 to 30 VDC 23 to 30 VDC
Output Bias Voltage 9.5 to 17 VDC 9.5 to 17 VDC
W - Water Resistant Cable
Electrical Connector Sealed Integral Cable Sealed Integral Cable
OPTION AL VERSION S
Optional versions have identical specifications and accessories as listed for the standard model except
where noted below. More than one option may be used.
NOTES:
[1]Typical.
[2]Zero-based, least-squares, straight line method.
[3]See PCB Declaration of Conformance PS023 for details.
Date: 03/06/2023 Date: 03/06/2023 Date: 03/06/2023 Date: 03/06/2023 46486
Entered: ND Engineer: JJD Sales: KK Approved: NJF Spec Number:
Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: info@pcb.com
3425 Walden Avenue, Depew, NY 14043
SUPPLIED ACCESSORIES:
Model 034G05 4-cond. shielded cable, 5 ft (1.5M), 4-pin plug to (3) BNC plugs (1)
Model 080A109 Petro Wax (1)
Model 080A90 Quick Bonding Gel (1)
Model ACS-1T NIST traceable triaxial amplitude response, 10 Hz to upper 5% frequency. (1)
1
1
2
2
3
3
4
4
A A
B B
CODE
IDENT. NO.
52681
DWG. NO.
SCALE: SHEET
DRAWN CHECKED ENGINEER
TITLE
UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:
DIMENSIONS IN MILLIMETERS
[ IN BRACKETS ]
ANGLES 2 DEGREES
3425 WALDEN AVE. DEPEW, NY 14043
(716) 684-0001 E-MAIL: sales@pcb.com
DIMENSIONS IN INCHES
ANGLES 2 DEGREES
FILLETS AND RADII
.003 - .005
FILLETS AND RADII
0.07 - 0.13
OUTLINE DRAWING
66452
1 OF 1
4X
.25 CUBE W 1/4-28 4-PIN CONNECTOR
OFF GROUND TRIAXIAL ACCELEROMETER
DECIMALS XX ±.03
XXX ±.010
DECIMALS X ± 0.8
XX ± 0.25
JDM 1/26/17 JDM 1/26/17 RMB 1/26/17
66452
PCB Piezotronics Inc. claims proprietary rights in
the information disclosed hereon. Neither it nor any
reproduction thereof will be disclosed to others
without the written consent of PCB Piezotronics Inc.
REVISIONS
REV DESCRIPTION DIN
NR RELEASED TO DRAFTING 46410
.41 [10.3]
.28 [7.1] CUBE
1.052 .125 26.72 3.18
[]
ATTACHED 034AD005CA CABLE
5 ft [1.5M] LONG TERMINATING
IN 4-PIN JACK
GROUND
"Y"
"X"
"Z"
1
1
1
1FACE IS GROUND ISOLATED >108
OHMS

Other PCB Piezotronics Measuring Instrument manuals

PCB Piezotronics 353B32 User manual

PCB Piezotronics

PCB Piezotronics 353B32 User manual

PCB Piezotronics Larson Davis SoundAdvisor NMS044 User manual

PCB Piezotronics

PCB Piezotronics Larson Davis SoundAdvisor NMS044 User manual

PCB Piezotronics 354B21 User manual

PCB Piezotronics

PCB Piezotronics 354B21 User manual

PCB Piezotronics 3743F1150G User manual

PCB Piezotronics

PCB Piezotronics 3743F1150G User manual

PCB Piezotronics ICP YJM320C15 User manual

PCB Piezotronics

PCB Piezotronics ICP YJM320C15 User manual

PCB Piezotronics 1903-01B User manual

PCB Piezotronics

PCB Piezotronics 1903-01B User manual

PCB Piezotronics 355M73 User manual

PCB Piezotronics

PCB Piezotronics 355M73 User manual

PCB Piezotronics 357A19 User manual

PCB Piezotronics

PCB Piezotronics 357A19 User manual

PCB Piezotronics IMI Sensors M603C00 User manual

PCB Piezotronics

PCB Piezotronics IMI Sensors M603C00 User manual

PCB Piezotronics Triaxial ICP 356A12/010CA User manual

PCB Piezotronics

PCB Piezotronics Triaxial ICP 356A12/010CA User manual

PCB Piezotronics J353B01 User manual

PCB Piezotronics

PCB Piezotronics J353B01 User manual

PCB Piezotronics J352C68 User manual

PCB Piezotronics

PCB Piezotronics J352C68 User manual

PCB Piezotronics 3711E1125G User manual

PCB Piezotronics

PCB Piezotronics 3711E1125G User manual

PCB Piezotronics IMI SENSORS M626B01 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS M626B01 User manual

PCB Piezotronics 357B83 User manual

PCB Piezotronics

PCB Piezotronics 357B83 User manual

PCB Piezotronics 357B90 User manual

PCB Piezotronics

PCB Piezotronics 357B90 User manual

PCB Piezotronics M320C53 User manual

PCB Piezotronics

PCB Piezotronics M320C53 User manual

PCB Piezotronics 350B01 User manual

PCB Piezotronics

PCB Piezotronics 350B01 User manual

PCB Piezotronics M353B16 User manual

PCB Piezotronics

PCB Piezotronics M353B16 User manual

PCB Piezotronics 354B33 User manual

PCB Piezotronics

PCB Piezotronics 354B33 User manual

PCB Piezotronics IMI SENSORS 629M34 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 629M34 User manual

PCB Piezotronics ICP 339B32 User manual

PCB Piezotronics

PCB Piezotronics ICP 339B32 User manual

PCB Piezotronics 003C30 User manual

PCB Piezotronics

PCB Piezotronics 003C30 User manual

PCB Piezotronics 3713B1230G User manual

PCB Piezotronics

PCB Piezotronics 3713B1230G User manual

Popular Measuring Instrument manuals by other brands

Powell EcoVisor 01.41B.48080 Instruction bulletin

Powell

Powell EcoVisor 01.41B.48080 Instruction bulletin

Ametek 5830 user manual

Ametek

Ametek 5830 user manual

Waltron 9096 user manual

Waltron

Waltron 9096 user manual

AEMC instruments 5070 user manual

AEMC instruments

AEMC instruments 5070 user manual

ANALOX Ax60+ Multi-Gas quick start guide

ANALOX

ANALOX Ax60+ Multi-Gas quick start guide

Agilent Technologies Cary 50 Hardware manual

Agilent Technologies

Agilent Technologies Cary 50 Hardware manual

ADVANTEST R3267 series Operation manual

ADVANTEST

ADVANTEST R3267 series Operation manual

Campbell CMP3 instruction manual

Campbell

Campbell CMP3 instruction manual

FNM alpha SM 230 user manual

FNM

FNM alpha SM 230 user manual

EUTECH INSTRUMENTS DO 700 instruction manual

EUTECH INSTRUMENTS

EUTECH INSTRUMENTS DO 700 instruction manual

Vega VEGAFLEX 86 operating instructions

Vega

Vega VEGAFLEX 86 operating instructions

Rotem AMP-50 operating & maintenance manual

Rotem

Rotem AMP-50 operating & maintenance manual

MSA Ultima X Series Installation & maintenance instructions

MSA

MSA Ultima X Series Installation & maintenance instructions

Keysight N1914A datasheet

Keysight

Keysight N1914A datasheet

ZHYQ GND15 quick start guide

ZHYQ

ZHYQ GND15 quick start guide

Tektronix Keithley 6517B/E user manual

Tektronix

Tektronix Keithley 6517B/E user manual

Agilent Technologies 4291B Operation manual

Agilent Technologies

Agilent Technologies 4291B Operation manual

Burster DIGIFORCE 9310 manual

Burster

Burster DIGIFORCE 9310 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.