Model: LM2
Lamp Module
Installation Guide and
Owner’s Manual
CONFIGURATION
Once your LM2 is installed it can be configured either
manually or with the UPStart Setup Software.
Manual configuration can be used to add your LM2 device
into a UPB network, link it to controller buttons and change
preset light levels. Refer to the Keypad Controller’s Manual
Configuration Guide available on the PulseWorx website
(www.PulseWorx.com) for more details.
Although the factory default operation of the LM2 is useful in
many situations, it is highly recommended that your device
be configured with the UPStart Setup Software so that you
can take advantage of its many configurable features.
PCS has developed a Powerline Interface Module (PIM) and
free software (UPStart) to help you configure all of your
PulseWorx Lighting System devices. User’s Guides are
available on the PulseWorx web site: www.PulseWorx.com to
explain how to configure your system.
Note: The LM2 can be configured to disable the dimmer so it
can turn ON and OFF non-dimmable loads such as
fluorescent lamps.
SETUP Mode
When configuring a UPB system, it will be necessary to place
the LM2 in SETUP mode. To do this, press the Program
Button (see illustration) five times rapidly. The Status LED
will continuously blink Blue when the device is in SETUP
mode. To exit SETUP mode, press the Program Button once
or wait five minutes for it to time out.
OPERATION
The Lamp Module operates according to commands sent by
UPB controllers.
The LM2 can accept powerline commands from any UPB-
compatible transmitter such as PulseWorx Keypad
Controllers, Timed Event Controllers, Wall Switches, Interface
Modules, Approved Third-Party Controllers and touch
screens. Each channel of the LM2 can be a member of up to
16 scenes with the capability to store a pre-set light level (0%
- 100%, or blink) and fade/blink rate for each scene.
Lamp Switch Triggers
The LM1will sense when the local lamp switch has gone from
opened to closed and can automatically turn on the lamp
when this occurs.
AUTO-OFF Timers
New for Generation 2 is the ability to set a maximum on time. If
you forget to shut the lamp off yourself then the lamp module
will do it for you automatically. The LM2 can be configured to
inform the rest of the network when it has automatically turned
the lamp off. This allows the LM2 to remotely control other
devices or update feedback indicators such as LEDs.
TEST Mode
A manual test feature allows the lamp to be turned ON and OFF
locally. To enable the TEST mode press and hold the Program
Button on the LM2 for three to five seconds. The Status LED
will blink Magenta to indicate TEST mode. Lamp #1 can now be
turned ON and OFF by single-tapping the Program Button.
Lamp #2 can be turned ON and OFF by double-tapping the
Program Button. Press and hold the Program Button again for at
least three seconds to exit from TEST mode.
Factory Default Settings
To restore the following default settings put the LM2 into SETUP
mode and then press the Program Button ten times rapidly. The
Status LED will blink red to indicate that factory defaults have
been restored. Press the Program Button twice more to stop the
blinking.
Network ID: 255
Unit ID: 10
Network Password: 1234
Receive Components: Link #1 = 100% @ 1.6 secs
(Channel #1) Link #2 = 0% @ 1.6 secs
Link #8 = Blink @ 0.5 secs
Receive Components: Link #1 = 100% @ 1.6 secs
(Channel #2) Link #2 = 0% @ 1.6 secs
Link #8 = Blink @ 0.5 secs
TYPICAL USES
The LM2 is perfect for controlling 120VAC dimming loads such
as:
•Incandescent bulbs,
•Some dimmable compact fluorescent bulbs,
•120VAC magnetic transformers,
•Fluorescent lights (when dimming is disabled).
LIMITED WARRANTY
Seller warrants this product, if used in accordance with all
applicable instructions, to be free from original defects in
materials and workmanship for a period of five years from the
date of purchase. Refer to the warranty information on the
PulseWorx website (www.PulseWorx.com) for exact details.