As manufacturers of electro-medical products we can assume responsibility for safety-related performance of the
equipment only if maintenance, repair and modications are carried out only by us or agencies we have authorized
for this purpose, and if components affecting safe operation of the chair that may be needed are replaced with original
parts.
We suggest that you request a certicate showing the nature and extent of the work performed, from those who carry
out such work, and specify that the certicate show any changes in rated parameters or working ranges, as well as the
date, the name of the rm and a signature.
WARNING: Only authorized service
technicians should attempt to install or
service this equipment. Use of other than
authorized technicians will void the warranty.
WARNING: A dental chair may include
magnets in the construction of the
device which may temporarily affect
the function/programming of some
implantable pacemakers or debrillators.
If the implanted device is programmed
to respond to a magnet, people who
have these types of devices should avoid
dental chairs with magnets.
This product is designed for use in an
indoor temperature controlled ofce
environment.
Review the following safety precautions to avoid injury and prevent damage to this equipment. Use this product only
as specied.
WARNING: Use a licensed electrician
for all wiring.
WARNING: Failure to disinfect equipment
between patients could expose user/
patient to cross contamination and bio-
burden/bio-contamination.
WARNING: No modification of this
equipment is allowed.
WARNING: This product must be
disinfected before use.
WARNING: To avoid risk of electric shock,
this equipment must be connected only to
supply mains with protective earth.
SAFETY INFORMATION
WARNING: Power cords and their
associated parts cannot be substituted
without increased risk of electric shock or
re. We recommend the use of original
equipment replacement parts only! Power
cords must be installed by qualied
personnel. Make sure all service loops,
strain reliefs, and cord guards are in
place and that line, neutral and ground
wires are secured.
WARNING: Maximum load rating for this
chair is 450 lbs. To avoid personal injury
and/or damage to the chair, do not exceed
this limit.
WARNING: To avoid possible injury and/
or damage to the chair, do not apply full
body weight on the headrest, backrest,
toeboard and armrest. Doing so may
cause the chair to tip.
WARNING: Support the patient’s head
and neck when adjusting the headrest.
Failure to do so may result in injury to the
patient.
WARNING: Use caution when using arm
rests for leverage when exiting the chair,
as arms may rotate and cause patient to
fall or get injured.
WARNING: Do not operate chair when
any cover is removed. Doing so may
result in injury to the operator.
WARNING: Do not place knees or legs
under chair arm support when chair is
being lowered.
WARNING: To avoid injury, discontinue
use of chair and have serviced by
authorized dealer if oil is seen leaking
from chair hydraulic system.
WARNING: Use caution when lling the
hydraulic reservoir to avoid overow and
spillage.
WARNING: Locate and position chair so
that it can be easily unplugged.
This equipment is not for use in rooms
where and explosion hazard exists