manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PennBarry
  6. •
  7. Fan
  8. •
  9. PennBarry ZQ165 User manual

PennBarry ZQ165 User manual

Page 1
VENTILATION FAN MODEL ZQ165
TM
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as
a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, includ-
ing fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the
local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling
installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS
PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
READ AND SAVE
THESE INSTRUCTIONS
Installer: Leave this manual with
the homeowner.
OPERATION
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the
blower assembly (includes motor and impeller).
Use an on/off switch or speed control to operate this ventilator. See “Connect Wiring” for details. Use of speed controls other than PennBarry
supplied models may cause a motor humming noise.
Page 2
VENTILATION FAN MODEL ZQ165
TM
TYPICAL
INSTALLATIONS
Housing
mounted to
I-joists.
Use I-joist
spacer block
(provided).
Housing mounted
anywhere between
trusses using
hanger bars.
Housing
mounted
anywhere
between
I-joists
using
hanger bars.
Housing
mounted to
joists.
Housing
mounted
anywhere
between
joists
using
hanger bars.
Housing
mounted to
truss.
PLAN THE INSTALLATION
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45o45o
NOT FOR USE IN
A COOKING AREA.
ROOF CAP*
(with built-in
damper)
WALL CAP*
(with built-in
damper)
6-IN. ROUND
ELBOWS*
6-IN. ROUND
DUCT*
FAN
HOUSING
Seal gaps
around
housing.
Seal duct
joints with
tape.
Keep duct
runs short.
INSULATION
(Place around and
over fan housing.)
POWER
CABLE*
*Purchase
separately.
OR
The ducting from this fan to the outside of the building has a strong effect on the
air flow, noise and energy use of the fan. Use the shortest, straightest duct routing
possible for best performance, and avoid installing the fan with smaller ducts than
recommended. Insulation around the ducts can reduce energy loss and inhibit
mold growth. Fans installed with existing ducts may not achieve their rated airflow.
Page 3
VENTILATION FAN MODEL ZQ165
TM
1b. Mount housing anywhere between
trusses, joists, or I-joists using hanger
bars.
Sliding hanger bars are provided to allow for accurate positioning
of housing anywhere between framing. They can be used on all
types of framing (I-joist, standard joist, and truss construction)
and span up to 24”.
Attach the MOUNTING CHANNELS to the housing using the
SCREWS supplied.
Extend HANGER
BARS to the width of
the framing.
Hold housing in place
so that bottom edge of
housing will be flush
with finished surface
of ceiling. For 1/2”
thick ceiling material,
position bottom of
each mounting flange
flush with bottom of
joist.
OR
INSTALL HOUSING & DUCT
1a. Mount
housing to
joist.
Hold housing
in place so that
bottom edge
of housing will
be flush with
finished surface
of ceiling. For
1/2” thick ceiling
material, position bottom of each mounting flange flush
with the bottom of joist. The housing mounts with four (4)
screws or nails. Screw or nail housing to joist through low-
est holes in each mounting flange, then through highest
holes. NOTE: Mounting to I-JOIST (shown) requires use
of SPACERS (included) between the highest hole of each
mounting flange and the I-joist.
2. Attach
damper/duct
connector.
3. Install
6-inch round
ductwork.
Connect 6-inch
round ductwork
to damper / duct
connector. Run
ductwork to a roof
cap or wall cap.
Tape all ductwork
connections
to make them
secure and air tight.
SPACER
(use for
mounting
to I-Joist)
TOP AND BOTTOM FLANGES
REMAIN OUTSIDE OF HOUSING
I-JOIST
SCREW
FROM
PARTS BAG
INSERT
TAB INTO
SLOT IN
HOUSING
To ensure a noise-free
mount: Secure hang-
ing bars together with
SCREWS and use a
pliers to crimp mount-
ing channels tightly
around hanger bars.
Page 4
VENTILATION FAN MODEL ZQ165
TM
1103108A
5. Insert mask
and finish
ceiling.
Tape mask into
housing. Mask
protects unit dur-
ing construction.
Remove before
installing grille.
Install ceiling
material. Cut out
around housing.
INSTALL MASK &
FINISH CEILING
4. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to
wiring plate. Connect wires as shown in wiring diagrams.
CONNECT WIRING
SCREW
WIRNG PLATE
& SCREW
FROM PARTS
BAG
INSTALL GRILLE
6. Attach
grille to
housing.
Squeeze grille
springs and
insert them
into tabs on
each side of
housing.
7. Push grille
against
ceiling.

Other PennBarry Fan manuals

PennBarry Breezeway User manual

PennBarry

PennBarry Breezeway User manual

PennBarry Fumex User manual

PennBarry

PennBarry Fumex User manual

PennBarry Muffan FS Manual

PennBarry

PennBarry Muffan FS Manual

PennBarry Breezeway BX Installation guide

PennBarry

PennBarry Breezeway BX Installation guide

PennBarry Zephyrette Manual

PennBarry

PennBarry Zephyrette Manual

PennBarry ZQ105 User manual

PennBarry

PennBarry ZQ105 User manual

PennBarry Zephyr Z1 Installation guide

PennBarry

PennBarry Zephyr Z1 Installation guide

PennBarry ROUND CENTREX Manual

PennBarry

PennBarry ROUND CENTREX Manual

PennBarry ZQ405 User manual

PennBarry

PennBarry ZQ405 User manual

PennBarry BX12Q Manual

PennBarry

PennBarry BX12Q Manual

PennBarry DYNAMO Manual

PennBarry

PennBarry DYNAMO Manual

PennBarry MXI Series Manual

PennBarry

PennBarry MXI Series Manual

PennBarry RAU User manual

PennBarry

PennBarry RAU User manual

PennBarry SWP series Manual

PennBarry

PennBarry SWP series Manual

PennBarry ESA Manual

PennBarry

PennBarry ESA Manual

PennBarry ZephyrZL1 Manual

PennBarry

PennBarry ZephyrZL1 Manual

PennBarry ZQ2005N User manual

PennBarry

PennBarry ZQ2005N User manual

Popular Fan manuals by other brands

BLAUBERG Axis-FP Series user manual

BLAUBERG

BLAUBERG Axis-FP Series user manual

Orbegozo SF 3345 instruction manual

Orbegozo

Orbegozo SF 3345 instruction manual

PureMate PM 710 instruction manual

PureMate

PureMate PM 710 instruction manual

Princess SMART 01.358450.02.001 instruction manual

Princess

Princess SMART 01.358450.02.001 instruction manual

PowerPac PPUF223 manual

PowerPac

PowerPac PPUF223 manual

Vents VK Series user manual

Vents

Vents VK Series user manual

Applica C163CM Use and care book

Applica

Applica C163CM Use and care book

Hunter Neutron installation manual

Hunter

Hunter Neutron installation manual

Salda AMBERAIR Assembly manual

Salda

Salda AMBERAIR Assembly manual

Becker SV 200 operating instructions

Becker

Becker SV 200 operating instructions

Delta Electronics AFB0305HA Dimensions and installation information

Delta Electronics

Delta Electronics AFB0305HA Dimensions and installation information

Westinghouse Mountain Gale manual

Westinghouse

Westinghouse Mountain Gale manual

Fanimation AIREFLUSH LP6804 Series Assembly instructions

Fanimation

Fanimation AIREFLUSH LP6804 Series Assembly instructions

Emerson Carrera Veranda CF552GBZ00 owner's manual

Emerson

Emerson Carrera Veranda CF552GBZ00 owner's manual

S&P CADB-HE BASIC Series manual

S&P

S&P CADB-HE BASIC Series manual

Lincat SV1212 User and installation instructions

Lincat

Lincat SV1212 User and installation instructions

Mitsubishi Electric Lossnay series Technical manual

Mitsubishi Electric

Mitsubishi Electric Lossnay series Technical manual

Salda RIRS 400HE/HW EKO 3.0 Technical manual

Salda

Salda RIRS 400HE/HW EKO 3.0 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.