You have purchased a product made by JUNG PUMPEN and
with it, therefore, also excellent quality and service. Secu-
re this service by carrying out the installation works in ac-
cordance with the instructions, so that our product can per-
form its task to your complete satisfaction. Please remember
that damage caused by incorrect installation or handling will
adversely affect the guarantee. Therefore please adhere to
the instructions in this manual!
This appliance can be used by children aged 8 years or over
and by persons with limited physical, sensory or intellectual
capabilities, or with limited experience and knowledge, pro-
vided that they are supervised or have been instructed in
the safe use of the appliance and are aware of the dangers
involved. Children must not be allowed to play with the ap-
pliance. Cleaning and user maintenance must not be carried
out by children unless they are supervised.
Damage prevention in case of failure
Like any other electrical device, this product may fail due to a
lack of mains voltage or a technical defect.
If damage (including consequential damage) can occur as a re-
sult of product failure, the following precautions can be taken
at your discretion:
•Installation of a water level dependent (under circumstanc-
es, mains-independent) alarm system, so that the alarm can
be heard before damage occurs.
•Inspection of the collecting tank/chamber for tightness up
to the top edge before – or at the latest, during – installation
or operation of the product.
•Installation of backow protection for drainage units that can
be damaged by wastewater leakage upon product failure.
•Installation of a further product that can compensate in
case of failure of the other product (e.g. duplex unit).
•Installation of an emergency power generator.
As these precautions serve to prevent or minimise conse-
quential damage upon product failure, they are to be strictly
observed as the manufacturer’s guideline – in line with the
standard DIN EN specications as state of the art – when using
the product (Higher Regional Court Frankfurt/Main, Ref.: 2 U
205/11, 06/15/2012).
SAFETY INSTRUCTIONS
This instruction manual contains essential information that
must be observed during installation, operation and servic-
ing. It is therefore important that the installer and the respon-
sible technician/operator read this instruction manual before
the equipment is installed and put into operation. The manual
must always be available at the location where the pump or the
plant is installed.
Failure to observe the safety instructions can lead to the loss
of all indemnity.
In this instruction manual, safety information is distinctly la-
belled with particular symbols. Disregarding this information
can be dangerous.
General danger to people
Warning of electrical voltage
NOTICE!NOTICE!
Danger to equipment and operation
Qualication and training of personnel
All personnel involved with the operation, servicing, inspection
and installation of the equipment must be suitably qualied
for this work and must have studied the instruction manual in
depth to ensure that they are suciently conversant with its
contents. The supervision, competence and areas of responsi-
bility of the personnel must be precisely regulated by the ope-
rator. If the personnel do not have the necessary skills, they
must be instructed and trained accordingly.
Safety-conscious working
The safety instructions in this instruction manual, the existing
national regulations regarding accident prevention, and any
internal working, operating and safety regulations must be ad-
hered to.
Safety instructions for the operator/user
All legal regulations, local directives and safety regulations
must be adhered to.
The possibility of danger due to electrical energy must be pre-
vented.
Leakages of dangerous (e.g. explosive, toxic, hot) substances
must be discharged such that no danger to people or the envi-
ronment occurs. Legal regulations must be observed.
Safety instructions for installation, inspection and mainte-
nance works
As a basic principle, works may only be carried out to the equip-
ment when it is shut down. Pumps or plant that convey harmful
substances must be decontaminated.
All safety and protection components must be re-tted and/or
made operational immediately after the works have been com-
pleted. Their effectiveness must be checked before restarting,
taking into account the current regulations and stipulations.
Unauthorised modications, manufacture of spare parts
The equipment may only be modied or altered in agreement
with the manufacturer. The use of original spare parts and
accessories approved by the manufacturer is important for
safety reasons. The use of other parts can result in liability for
consequential damage being rescinded.
Unauthorised operating methods
The operational safety of the supplied equipment is only guar-
anteed if the equipment is used for its intended purpose. The
limiting values given in the "Technical Data" section may not be
exceeded under any circumstances.
Instructions regarding accident prevention
Before commencing servicing or maintenance works, cordon
off the working area and check that the lifting gear is in perfect
condition.
Never work alone. Always wear a hard hat, safety glasses and
safety shoes and, if necessary, a suitable safety belt.
Before carrying out welding works or using electrical devices,
check to ensure there is no danger of explosion.
People working in wastewater systems must be vaccinated
against the pathogens that may be found there. For the sake of
your health, be sure to pay meticulous attention to cleanliness
wherever you are working.
Make sure that there are no toxic gases in the working area.
Observe the health and safety at work regulations and make

3
ENGLISH
sure that a rst-aid kit is to hand.
In some cases, the pump and the pumping medium may be hot
and could cause burns.
For installations in areas subject to explosion hazards, special
regulations apply!
TECHNICAL DATA
Operating voltage: 230V/50Hz; 1.5W
Control voltage: 12V DC SELV (non-stabilised)
Alarm contact of the AG...: potential-free normally-open con-
tact; maximum possible load: 230 V / 5A AC.
Housing: (h x w x d) in mm: 147 x 71 x 70
Protection category IP20
Cable AG3, AG10: H07 RN-F
Cable AGE, AGR : LIYY PVC
Operating temperature: -20°C to 50°C
Humidity: 0 to 90% RH, with no condensation
DESCRIPTION
The AG… alarm transmitter has an integrated buzzer that emits a
loud signal if the water level in the pump chambers and containers
is too high or, in the case of the AGE model, if a leak is detected.
Only use the alarm transmitter in well ventilated rooms.
NOTICE! High humidity can cause malfunctions and perma-
nent damage to the alarm transmitter.
If required, the device can also be equipped with a 9 V rechar-
geable battery, for mains-independent operation.
The AG... alarm transmitters are tted with a potential-free te-
lecommunication contact.
EMC
The device is suitable for domestic/commercial use, connec-
ted to the public power supply network. If connected to an
industrial power supply network within an industrial facility,
where the supply is provided from a high-voltage transformer,
there may be insucient immunity to interference.
ELECTRICAL CONNECTION
WARNING!
Always pull the mains plug out of the socket before any work is
undertaken!
The housing may be opened only by a qualied electrician!
The device may be operated only if the housing is undamaged
and closed.
The device may only be connected to a socket outlet installed
in accordance with regulations, located in a dry room and
fused with 16 A (slow-blow) and a residual current circuit brea-
ker (≤30 mA).
Functional test
Lift up the oat switch (with the AGE: submerge the electrode
in water): The alarm should sound.
Rechargeable battery for mains-independent
alarm
CAUTION!
Only use the 9V-NiMh battery supplied by the manufacturer! If
dry-cell batteries or Lithium batteries are used there is a dan-
ger of explosion!
•Loosen the housing screws and open the housing carefully.
•Open the battery compartment in the cover. Press the con-
nector clip into place and lay the battery in the compartment.
•Replace the small cover, making sure it clicks into place, and
screw the alarm transmitter back together.
The system can operate for approximately 3 hours using the
battery. Once depleted, the battery is recharged by the alarm
circuit within approximately 100 hours. The service life of the
rechargeable battery is 5 to 10 years. Make a note of the date
that the battery was tted and carry out regular tests to ensure
that the device operates correctly when battery powered (with
no mains connection).
Dispose of used or leaking batteries at the established
collection points.
Potential-free telecommunication contact
only with AG…
•Loosen the housing screws and open the housing carefully.
•Feed the telecommunication cable into the housing through
the seal at the bottom left and connect it to terminal 40/41.
Strip the end insulation as short as possible.
•Use the free xing clip as a strain-relief clamp to secure the
cable.
•Screw the alarm transmitter back together.
•The maximum possible load for the normally-open contact
is 5A / 230V~.
230 V~
max.
5 A / 230 V~
V
9 V - Akku
(optional)
G1
40
41
21
22 AGE 21/22

4
ENGLISH
INSTALLATION
AG3, AG10
Fix the cable of the ball contact switch after approx. 35cm to
the wall, to relief any strain, with the cable holder and hose
clip, install the submersible ball contact switch at the desired
height, by xing it to the pressure pipe of the pump, for
example. Keep the connection length as short as possible (50
to 100 mm).
AGR
Before the special oat switch can be installed, the oat switch
cable must be temporarily disconnected from the device.
WARNING!
Always pull the mains plug out of the socket before any work is
undertaken!
The housing may be opened only by a qualied electrician!
Loosen the housing screws, open the housing carefully and
disconnect the two leads of the oat switch cable.
For the installation of the special oat switch, x the mounting
hole in the cover of the Hebex or in the compli 300 chamber,
as shown in the appendix.
Fix the special oat switch in the Hebex cover or to the compli
chamber.
Reconnect the oat switch cable (at terminal 21/22) in the de-
vice and screw the alarm transmitter back together.
Functional test: Plug the alarm transmitter into the socket and
lift up the oat of the special oat switch with your hand – the
device should trigger the alarm.
If the alarm is triggered when the oat is at its lower position,
the oat must be taken out of its guide and turned through 180°
before being replaced in the guide.
AGE
Place the electrode on the oor, as close as possible to the
appliances that are to be monitored. If, for example, the elec-
trode comes into contact with water as a result of a washing
machine leak, the alarm will sound. After the alarm has been
triggered, dry the electrode with a cloth.
Installation
AG3, AG10
Baux / Hebex 200
Hebex 100, compli 300
Hebex

5
UKCA 605.10-2023.01
UKCA-Declaration of Conformity
Legislation - Designated Standards
• Electromagnetic Compatibility Regulations 2016
(EMC) EN 55014-1: 2017/A11:2020, EN 55014-2: 1997/A2:2008
• The Restriction of the Use of Certain Hazardous
Substance in Electrical and Electronic Equipment
Regulations 2012 (RoHS)
• Electrical Equipment (Safety) Regulations 2016 EN 60335-1: 2012/A14:2019
Name and address of the manufacturer: JUNG PUMPEN GmbH - Industriestr. 4-6 - 33803 Steinhagen - Germany - www.jung-pumpen.de
We hereby declare, under our sole responsibility, that the product is in accordance with the specied Legislation.
AG3 GB (JP50770)
AG10 GB (JP50771)
AGE GB (JP50772)
AGR GB
(JP55611)
DKG GB
(JP55612)
Authorized person for technical documention
JUNG PUMPEN - Stefan Sirges - Industriestr. 4-6 - 33804 Steinhagen
Steinhagen, 30-01-2023
______________________ i.V. ____________________
Stefan Sirges, General Manager Pascal Kölkebeck, Sales Manager
Other normative documents:

All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners.
© 2022 Pentair Jung Pumpen
Jung Pumpen GmbH Pentair Water Italy Srl Pentair Water Polska Sp. z o.o.
Industriestr. 4-6 Via Masaccio, 13 ul. Plonów 21
33803 Steinhagen 56010 Lugnano - Pisa 41-200 Sosnowiec
Deutschland Italia Polska
Tel. +49 5204 170 Tel. +39 050 716 111 Tel. +48 32 295 1200
This manual suits for next models
3
Table of contents