Perle IRG5140+ Manual

IRG5140+Hardware Installation Guide
Updated: June 2023
Version A.06.13.2023
Document Part#:5500456-10
www.perle.com

Preface
I
Perle IRG5140+ Router Hardware Installation Guide
Preface
Audience
This guide is for the network or computer technician responsible for installing the Perle IRG5140+
router also generically referred to as the IRG5140 within this document.All “+” models support
worldwide global coverage for LTE. Familiarity with the concepts and terminology of LTE, GNSS,
Ethernet, and LAN (local area networks) is required.
Purpose
Perle routers provide users, networking equipment, as well as M2M & IoT appliances with network
connectivity for fixed locations (i.e. buildings, POS, Kiosks, …etc.) and mobile (i.e. vehicle, trains,
robots) applications. In vehicular applications, the router provides connectivity and does not interact
with the vehicle’s operation or vehicle operators.
This document describes the hardware and physical characteristics of the Perle IRG5140+ router. It
covers hardware features as well as installation and operation. This document does not cover how to
configure your Perle IRG5140+ router. Information to configure your Perle router can be found in the
Perle IRG7000/5000 5G/LTE Router User’s Guide and the Perle IRG7000/5000 5G/LTE Router
Command Line Reference Guide on the Perle website. Quick Start information can be found in the
IRG5140+ Series Router Quick Start Guide (QSG) that comes with your product.
Key Features
• Supports bridging/switching, and routing
• 4G/LTE coverage spanning 24 frequency bands in North America/EMEA
• 3G HSPA/HSPA+ Bands 9
• Fully automatic network switching supporting dual network SIMs
• Routing with Primary/Backup route
• LTE and VPN Fail-over
• Provides network connectivity via LTE, Ethernet, and USB-C
• Active GPS for tracking equipment
• Security via remote authentication (Radius/RadSec and TACACS+)
• Meets industry-grade certifications

Preface
II
Perle IRG5140+ Router Hardware Installation Guide
Additional Documentation
Document Description
Perle IRG7000/5000 5G/LTE Router
User’s Guide
User’s guide explaining how to configure the IRG5140+
features using the Web Manager application. New users
should use this method to configure the router.
Perle IRG7000/5000 5G/LTE Router
Command Line Reference Guide
Command Line Interface Reference Guide using CLI
commands to configure the IRG 5140+(this is an
advanced way to configure the router).

Preface
III
Perle IRG5140+ Router Hardware Installation Guide
Document Conventions
This document contains the following conventions:
Most text is presented in the typeface used in this paragraph. Other typefaces are used to help you
identify certain types of information. The other typefaces are:
Note: Means reader take note: notes contain helpful suggestions.
Caution: Means reader be careful. In this situation, you might perform an action that could result in
equipment damage or loss of data.
Warning: IMPORTANT SAFETY INSTRUCTIONS
Means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be
aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing
accidents.
Important Notice
Due to the nature of wireless communications, transmission and reception of data can never be
guaranteed. Data may be delayed, corrupted (i.e., have errors) or be totally lost. Although significant
delays or losses of data are rare when cellular devices such as the Perle IRG5140 Series Routers are
used in a normal manner with a well-constructed network. The Perle IRG5140 Series Routers should
not be used in situations where failure to transmit or receive data could result in damage of any kind
to the user or any other party, including but not limited to personal injury, death, or loss of property.
Perle accepts no responsibility for damages of any kind resulting from delays or errors in data trans-
mitted or received using our products.
Safety and Hazards
The driver or operator of any vehicle should not operate the IRG5140 while in control of a vehicle.
Doing so will detract from the driver or operator's control and operation of that vehicle. The IRG5140
is Listed to UL121201 and CSA C22.2 No. 213 and are suitable for use in Class I, Division 2, Groups
A, B, C and D Hazardous Locations.
The following warnings and instructions apply:
Limitation of Liability
The information in this manual is subject to change without notice and does not represent a commit-
ment on the part of Perle for any and all direct, indirect, special, general, incidental, consequential,
punitive or exemplary damages including, but not limited to loss of profits or revenue or anticipated
profits or revenue arising out of the use or inability to use any Perle IRG5140 series router even if
Perle has been advised or the possibility of such damages or they are
foreseeable or for claims by any third party.
Notwithstanding the foregoing, in no event shall Perle aggregate liability arising under or in connec-
tion with the Perle product, regardless of the number of events, occurrences, or claims giving rise to
liability, be in excess of the price paid by the purchaser for the Perle
product.
Copyright © 2023 Perle. All rights reserved.
Windows® is a registered trademarks of Microsoft Corporation.
Other trademarks are the property of their respective owners

Preface
IV
Perle IRG5140+ Router Hardware Installation Guide
General cautions and warnings
Warning: Power sources must be off prior to beginning the power connection steps. Read the
installation instructions before you connect the unit to its power source.
Avertissement: Les sources d'alimentation doivent être éteintes avant de commencer les étapes de
connexion d'alimentation. Veuillez lire les instructions d’installation avant de connecter l’appareil à
sa source d’alimentation.
Warning: Ensure that the voltage and current ratings of the intended power source are appropriate for
the IRG5140+ Series of Routers as indicated on the product label.
Avertissement: Assurez-vous que les valeurs nominales de tension et de courant de la source d'ali-
mentation prévue conviennent aux routeurs de la série IRG5140, comme indiqué sur l'étiquette du
produit.
Warning: Ensure that the installation and electrical wiring of the equipment is performed by trained
and qualified personnel and that the installation complies with all local and national electrical codes.
Avertissement: Assurez-vous que l'installation et le câblage électrique de l'équipement sont effectués
par du personnel formé et qualifié et que l'installation est conforme à tous les codes électriques locaux
et nationaux.
Warning: This equipment must be used in the matter specified by the manufacturer.
Avertissement: Cet équipement doit être utilisé dans les matières spécifiées par le fabricant.
Warning: In case of malfunction or damage, no attempts at repair should be made by the user. Do not
dismantle this product. In case of malfunction or damage, contact Perle Technical support at
https://www.perle.com/support_services/support_request.aspx
or email at
https://www.perle.com/support_services/support_request.aspx#form
Avertissement: En cas de dysfonctionnement ou de détérioration, aucune tentative de réparation ne
doit être effectuée par l'utilisateur. Ne démontez pas ce produit. En cas de dysfonctionnement ou de
dommage, contactez le support technique de Perle à l'adresse
https://www.perle.com/support_services/support_request.aspx
ou par courrier électronique à
https://www.perle.com/support_services/support_request.aspx#form
Warning: “Equipment is intended for installation in Restricted Access Area when equipment is
installed in ambient exceeding 50°C (122°F)”. The unit should be installed in a restricted access loca-
13 IEC 60417-5041 (2002-10) “WARNING: HOT
SURFACE. DO NOT
TOUCH.” / ATTENTION:
Surface chaude. Ne pas
toucher.”
14 Refer to manual/safety

Preface
V
Perle IRG5140+ Router Hardware Installation Guide
tion where access can only be gained by service personnel or users who have been instructed about
the reasons for the restrictions applied to the location and about any precautions that shall be taken;
and access is through the use of a tool or lock and key, or any means of security, and is controlled by
the authority responsible for the location.
Avertissement: L’équipement est destiné à être installé dans une zone d’accès restreint lorsque
l’équipement est installé dans une température ambiante supérieure à 50 °C (122 °F). l'unité doit être
installée dans un emplacement à accès restreint, auquel seul le personnel de service ou les utilisateurs
informés des raisons des restrictions appliquées peuvent accéder. sur le lieu et sur les précautions à
prendre; et l'accès se fait au moyen d'un outil ou d'un verrou et d'une clé, ou de tout moyen de sécu-
rité, et est contrôlé par l'autorité responsable du lieu.
Warning: The working voltage inputs are designed for operation with Safety extra low Voltage
(SELV). Connect only to SELV circuits with voltage restrictions in line with IEC/EN 62368-1.
Avertissement: Les entrées de tension sont conçues pour fonctionner avec une tension de sécurité
très basse (SELV). Connectez uniquement aux circuits SELV avec des restrictions de tension con-
formes à IEC / EN 62368-1.
Warning: For equipment installed within the same end-product enclosure ensure leads are segregated
or insulated the leads from different circuits.
Avertissement: Pour les équipements installés dans le même boîtier de produit final, assurez-vous
que les conducteurs sont séparés ou isolés des conducteurs de circuits différents.
Hazardous Location Warnings
Specific Conditions of Use
1. The IRG5140+ Routers are intended for installation into an IECEx/ATEX certified and IP54
minimum rated enclosure in accordance with IEC/EN IEC 60079-0 and accessible only by the use of
a tool. Les modèles de routeurs IRG5140+ sont destinés à être installés dans un boîtier certifié
IECEx/ATEX qui conforme à la norme IP54 conformément à la norme IEC/EN IEC 60079-0 et
accessible uniquement à l'aide d'un outil.
2. The IRG5140+ Routers shall only be used in an area of not more than pollution degree 2, as
defined in IEC/EN 60664-1. L'équipement ne doit être utilisé que dans une zone où le degré de
pollution n'est pas supérieur à 2, tel que défini dans la IEC/EN 60664-1.
Warning: These devices are open-type devices that are to be installed in an enclosure with tool
removable cover or door, suitable for the environment.
Avertissement: Ces périphériques sont des périphériques de type ouvert à installer dans un boîtier
avec un couvercle ou une porte amovible pour outils, adapté à l'environnement.
Warning: This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D, or only non
hazardous locations.
Avertissement: Cet équipement est adapté à une utilisation dans les zones non dangereuses de classe
I, division 2, groupes A, B, C, D
Warning: WARNING-EXPLOSION HAZARD - Do not connect or disconnect equipment unless
power has been removed or the area is known to be non-hazardous.

Preface
VI
Perle IRG5140+ Router Hardware Installation Guide
Avertissement: DANGER D'EXPLOSION ET D'AVERTISSEMENT - Ne pas connecter ou decon-
necter l'équipement tant que l'alimentation n'est pas débranchée ou que la zone n'est pas dangereuse.
Warning: WARNING-EXPLOSION HAZARD - Substitution of any components on this unit may
impair suitability for Class I, Division 2.
Avertissement: DANGER DANGER D’EXPLOSION - La substitution de tout composant de cet
appareil peut compromettre l’adéquation à la Classe I, Division 2.
Warning: Power supply of the equipment must be rated appropriately (see Appendix for specifica-
tions) with limited power. Limited power means complying with one of the following requirements.
Class 2 circuit according to Canadian Electrical Code, Part 1, C22.1
Class 2 circuit according to National Electrical Code, NFPA-70
Limited Power Supply (LPS) according to EN/IEC 60950-1;
Limited-energy circuit according to EN/IEC 61010-1
Avertissement: l'alimentation de l'équipement doit être correctement dimensionnée (voir annexe
pour les spécifications) avec une puissance limitée. Une puissance limitée signifie que vous vous con-
formez à l'une des exigences suivantes.
Circuit de classe 2 selon le code électrique Canadien, partie 1, C22.1
Circuit de classe 2 selon le code électrique national NFPA-70
Alimentation électrique limitée (LPS) selon EN / IEC 60950-1;
Circuit à énergie limitée selon EN / IEC 61010-1
Warning: If this equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Avertissement: Si cet équipement est utilisé d'une manière non spécifiée par le fabricant, la protec-
tion fournie par l'équipement peut être altérée.
Warning: In case of malfunction or damage, no attempts at repair should be made. Do not dismantle
the product. All repairs need to be made by a qualified Perle representative. Contact Perle Systems
Technical support at https://www.perle.com/support_services/support_request.aspx or email at
https://www.perle.com/support_services/support_request.aspx#form
Avertissement: En cas de dysfonctionnement ou de dommage, aucune tentative de réparation ne doit
être effectuée. Ne démontez pas le produit. Toutes les réparations doivent être effectuées par un
représentant qualifié de Perle. Contactez le support technique de Perle Systems à l'adresse
https://www.perle.com/support_services/support_request.aspx ou par courrier électronique à
https://www.perle.com/support_services/support_request.aspx#form
Warning: This router is not intended for use close to the human body. The unit should be mounted in
such that Antennas are at least 20cm (8 inches) away from any person.
Avertissement: Ce routeur n’est pas destiné à être utilisé à proximité du corps humain. L’appareil
devrait être monté de façon à ce que les antennes soient à au moins 20 cm (8 po) de toute personne.
Warning: Explosion hazard. Do not connect or disconnect while the circuit is live or unless the area
is free of ignitable concentrations.

Preface
VII
Perle IRG5140+ Router Hardware Installation Guide
Avertissement: Risque d'explosion. Ne pas connecter ou deconnecter le circuit est sous tension ou à
moins que la zone ne présente aucune concentration inflammable.
Warning: Do not use the USB connector unless the area is free of ignitable concentrations.
Avertissement: N'utilisez pas le connecteur USB à moins que la zone ne soit exempte de
concentrations inflammables.
Warning: Do not use the reset button unless the area is free of ignitable concentrations.
Avertissement: N'utilisez pas le bouton de réinitialisation à moins que la zone ne soit exempte de
concentrations inflammables.
RF Exposure
In accordance with FCC/IC requirements of human exposure to radio frequency fields, the radiating
element shall be installed such that a minimum separation distance of 20 cm should be maintained
from the antenna and the user's body.
Conformément aux exigences de la FCC/IC relatives à l’exposition humaine aux champs de
radiofréquences, l’élément de rayonnement doit être installé de manière à ce qu’une distance de
séparation minimale de 20 cm soit maintenue par rapport à l’antenne et au corps de l’utilisateur.
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS
GUIDE ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS,
INFORMATION, AND RECOMMENDATIONS IN THIS GUIDE ARE BELIEVED TO BE
ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF
ANY PRODUCTS.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not
installed and used in accordance with this hardware guide may cause harmful interference to radio communications.
Modifications to this product not authorized by Perle could void the FCC approval and negate your authority to operate the
product.
Perle reserves the right to make changes without further notice, to any products to improve reliability, function, or design.
Perle, the Perle logo, and IRG5140+ Series of Routers are trademarks of Perle.
Copyright ©2023 Perle.
60 Renfrew Drive, Markham, Ontario, L3R 0E1, Canada
All rights reserved. No part of this document may be reproduced or used in any form without written permission from Perle.

Preface
VIII
Perle IRG5140+ Router Hardware Installation Guide
Publishing History
Date Revision Update Details
March 2020 A.03.23.2020 Initial release.
Dec 2020 A.12.31.2020 Updates
June 2021 A.03.06.2021 Update to label
Jan 2022 A.01.30.2022 Added IRG7440 model (5G) and updates to other
models
March 2022 A.03.17.2022 Updated Hot warning
April 2022 A.04.08.2022 Updated Restricted Access Area warning
June 2023 A.06.13.2023 Added DHCP/BOOTP (ZTP mode) support for factory
default mode

Table Of Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
What’s Included . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
What You Need to Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SIM Card/s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Antenna/s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
USB-C Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ethernet LAN Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Ethernet Link Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
GNSS Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Terminal Block-Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Inserting the SIM card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Connecting to the Ethernet Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Connecting to the USB-C port in Console Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Connecting to the USB-C port as an Ethernet over USB Port. . . . . . . . . . . . . . . . . . 10
Connecting the Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Reset / Factory Default / Safe Mode / DHCP/BOOTP (ZTP mode) . . . . . . . . . . . . . 12
Fast Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Managing the IRG5140+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
WebManager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SNMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Fast Setup Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
PerleView. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
I/O Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Pulse Counter / Digital Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Appendix A—Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Appendix B—Sample Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Appendix C—Mounting the IRG5140+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Appendix D—Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Appendix E—Maintaining and Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Overview
1
Perle IRG5140+Router Hardware Installation Guide
Overview
The IRG5140+ router is a compact, rugged, fully featured communications platform for real-time
wireless capabilities. It has multiple communication ports including Ethernet, and a USB port that can
be used as a console port or as an additional Ethernet port. It supports LTE/4G wireless solutions for
both fixed and mobile applications (IoT). The LTE/4G supports Cat-12 technology with peak down-
load rates of 600 Mbps and uploads speeds of 150 Mbps. The IRG5140+ includes integrated GNSS
receiver (GPS, GLONASS, Beidou, and Galileo) satellite support.
Application uses:
• Monitoring and controlling remote equipment such as pipelines, meters, pumps, and valves
in energy, utility, or industrial applications
• Tracking the location of heavy equipment and assets in the field
• Providing reliable Internet access to a mobile workforce
What’s Included
The following components may be included with your product. Components will vary depending for
each model. See the Perle website for updates.
• The router
• Quick Start Guide that came with your product
• LTE SMA antenna pack (#08000120)
• GNSS PASV RP-Antenna SMA/CA (#08000130) order-able from Perle
What You Need to Supply
Before you can begin, you need to have the following:
• A SIM card/s (provided by your mobile network operator)
• #1 Phillips screwdriver (if you are installing the SIM card)
• Computer or laptop computer with Ethernet interface and cable
• An Ethernet CAT5e or CAT6 10/100/1000BASE-T cable/to connect the
router to the network

Hardware
2
Perle IRG5140+Router Hardware Installation Guide
Hardware
Front View
LEDs
Power LED
(P1 and P2)
Function Normal Low Power
Mode
Meaning
Power must be applied
to the Power inputs P1
and P2 in order for the
LEDs to light.
No Power Off N/A
Boot Red—solid N/A
Green— Blip N/A N/A
Powering up Amber—flashing N/A

Hardware
3
Perle IRG5140+Router Hardware Installation Guide
Normal
Operation
Green—solid Green—blip
starting after a
boot is
complete
Normal
operation but
no config
Green—flashing Unit is powered up
normally—unit has no
config. Unit is in Safe
mode or Factory
default mode.
Fatal error Red—solid Red—solid
Setup Mode Amber—solid Amber—solid When you press and
hold the reset button
for 5 seconds. The solid
amber led indicate the
time to release to
initiates setup mode.
Factory Reset Red—solid Red—solid When you press and
hold the reset button
for 20 seconds. The
solid red indicates the
time to release to
imitate reset to factory.
Overheat
Standby
Red—blip Red—blip Overheat caused the
unit to go into Standby
mode. Router will
restart when temp is
below the threshold.
No Config Green-flashing N/A Unit is powered up
normally—unit has no
config. Unit is in safe
mode or factory
default mode.
WWAN Function Normal Low Power
Mode
Meaning
Disabled Off Off

Hardware
4
Perle IRG5140+Router Hardware Installation Guide
Connected—
good signal
Color—solid Off–once a
connection is
established, it
will come on
for 5 secs then
go off
Colour will depend on
signal strength. Green
= Good signal— >= -
80dBm Amber = Fair
signal— >-94dBm <-
80dbm red="Poor"
signal—<="94dBm" <
body>
GNSS Function Normal Low Power
Mode
Meaning
Disabled Off Off No GPS activated or in
power saving mode.
Initializing Green—blip Off
Attempting to
get a fix or
unable to get a
fix
Amber—flashing Amber—blip
GPS fix Green—solid Off—green
solid for 5
seconds then
off
VPN Function Normal Low Power
Mode
Meaning
No VPN Off Off No VPN configured or
enabled
VPN
established
Green—solid Off VPN established—at
least 1 VPN connection
is up.
VPN failed Red—solid Red—blip Internet is up, but VPN
failed
Internet Function Normal Low Power
Mode
Meaning

Hardware
5
Perle IRG5140+Router Hardware Installation Guide
Disconnected Off Off No connection by
intention
disabled or radio
off
disconnect
requested
Connected Green—solid Off LTE primary if no
WAN
Primary connection
if WAN
Backup mode Amber—solid Off Backup connection if
WAN.
Connection
failure
Red—solid Red—blip A connection was
attempted, but it
failed.
APN incorrect
SIM card missing
insufficient signal
no service
modem failure
data connection
failed—waiting to
retry
Pin incorrect SIM
blocked, bad
unlock code
SIM locked
SIM blocked,
unblock code
incorrect

Hardware
6
Perle IRG5140+Router Hardware Installation Guide
SIM Card/s
The IRG5140+ supports two SIM cards. See Inserting the SIM card for the installation procedure.
SIM/s Interface 1.8V/3V
Antenna/s
The IRG5140+ has three SMA antenna connectors, Main, Div/GNSSL1, and GNSS. For more infor-
mation on connecting the antennas see the Technical Specifications section Connecting the
Antenna/s.
USB-C Port
In console mode, the IRG5140+ USB port provides direct access to the Command Line Interface
(CLI) as well as provides statuses, logging, and troubleshooting information. Alternative, this port
can be set as an Ethernet over USB port.
See Connecting to the USB-C port in Console Mode and Connecting to the USB-C port as an Ether-
net over USB Port.

Hardware
7
Perle IRG5140+Router Hardware Installation Guide
Ethernet LAN Ports
Once the ports are connected and the link is established, the speed LED will turn on. The LED
indicates a 10, 100, or 1000 Mbps link on the Ethernet port.
Ethernet Link Status
GNSS Connector
GPS+GLONAS+GAILEO
Passive Antenna—SMA(M) straight connector
See Appendix A—Technical Specifications for electrical details.
Link/Speed Indicator Description
Left LED Green Link + Flashing with activity 1000 Mbps
Both LEDs Link + Flashing with activity 100 Mbps
Right LED Green Link + Flashing with activity 10 Mbps
Off Off No LAN connected

Installation
9
Perle IRG5140+Router Hardware Installation Guide
Installation
The steps for a typical installation are:
1. Inserting the SIM card/s. See Inserting the SIM card.
2. Connecting the antenna/s. See Connecting the Antenna/s.
3. Connecting the Ethernet Ports. See Ethernet LAN Ports.
4. Connecting to the Console Port in Console Mode. See Connecting to the USB-C port in Console
Mode.
5. Using the Console port as a virtual Ethernet port. See Connecting to the USB-C port as an Ether-
net over USB Port.
6. Connecting the power. See Connecting the Power.
7. Logging into the IRG5140+. See Fast Setup or Connecting to the USB-C port in Console Mode.
Inserting the SIM card
The IRG5140+ comes with two SIM sockets for 2mini-SIM (2FF) cards.
Note: Ensure the power is disconnected before you insert the SIM card/s.
1. Using your Phillips screwdriver, removed the screw cover from the panel covering the SIM slot.
Gently pry the cover loose from the opening.
2. Align the SIM card so that the SIM card will slide into the top slot (slot#1). The SIM card has a
notched corner for orientation and the SIM card can only be inserted the correct way. You will
hear an audible click when the SIM is inserted correctly.Always populate slot#1 first. Add a
second SIM card if your network setup requires it.
3. Align the SIM cover plate and secure the plate with the screws.
Connecting the Antenna/s
The router has these connectors
• Main cellular female antenna connector
• Rx Diversity female antenna connector
• GNSS female antenna connector
1. Connect your cellualar antenna to the SMA cellular antenna connector labeled Main.
2. Connect your GPS antenna to the SMA GPS antenna connector labeled GNSS.
3. Mount the GPS antenna where is has a good sky view (at least 90°).
4. Connect the diversity antenna to the SMA diversity antenna labeled Diversity.
Note: Do not force the SIM card in or you may damage the card or your IRG5140+ router.

Installation
10
Perle IRG5140+Router Hardware Installation Guide
When attaching the antennas to the SMA connectors, line the inner hole within the antenna, then slide
onto the pin encased in the connector on the router, gently push to connect, then turn only the securing
ring and not the antenna to secure it to the router.
Connecting to the Ethernet Ports
The Ethernet RJ45 ports provides the standard Ethernet interface speeds of 10/100/1000 Mbps
through twisted pair (UTP) cables of up to 100 meters (328ft) in length. Cat5e or Cat6 cables are
recommended for 1000 Mbps connections.
Connecting to the USB-C port in Console Mode
By default, the USB-C port is set to console mode.
In this mode, the USB-C port acts as a console port.
1. Connect the power. See Connecting the Power.
2. Allow the router to complete the boot up sequence.
3. Connect a USB cable to the PC’s USB port, then connect the other end of the cable to the router’s
USB-C connector.
4. On the PC Choose Start -> Control Panel -> Hardware and Sound (or equivalent) on the Windows
Operating System. Choose the Device Manager, and expand the Ports section. The assigned COM
port can be identified.
5. Start a terminal emulation program (such as Putty or SecureCRT) on the com port where you have
connect the cable to the PC.
6. Press the Enter key on the keyboard and the prompt will display.
See the Perle IRG7000/5000 5G/LTE Router CLI Reference Guide for more information on
using CLI commands.
Connecting to the USB-C port as an Ethernet over USB Port
In this mode, the USB-C port behaves like a PC is connected to the Ethernet port, allowing access to
networks and the Internet.
See the Perle IRG7000/5000 5G/LTE Router User’s Guide and the Perle IRG7000/5000 5G/LTE
Router CLI Reference Guide for more information on setting this parameter.
Warning: For Zone 2 and/or Class I, Division 2 hazardous location applications. Antennas intended for use with
the product must be installed within the end use enclosure. For remote mounting of the antennas in unclassified
or classified locations, routing and installation of the antennas shall be in accordance with the appropriate
location regulations.
Warning: If you connect or disconnect the console cable with the power applied to the router or any device on the
network, an electrical arc can occur. This could cause an explosion when installed in a hazardous location. Ensure
the power is removed from all devices prior to making any cable connections.
Warning: Do not use the USB port in a potentially explosive environment.
Other manuals for IRG5140+
3
Table of contents
Other Perle Network Router manuals

Perle
Perle IRG7440 User manual

Perle
Perle IRG5410 Series Manual

Perle
Perle PERLE P850 Instruction Manual

Perle
Perle IOLINK-520 User manual

Perle
Perle P840 Instruction Manual

Perle
Perle IRG5140+ Manual

Perle
Perle P840 User manual

Perle
Perle IOLAN SDG4 LA/LE Manual

Perle
Perle PERLE P850 User manual

Perle
Perle P1705 User manual

Perle
Perle P840 Instruction Manual

Perle
Perle IRG5410 Series User manual

Perle
Perle IRG5140+ Manual

Perle
Perle IRG5540 User manual

Perle
Perle IOLAN STS8D GR User manual

Perle
Perle IRG5540 Manual

Perle
Perle IOLAN SDG2 LA/LE Manual

Perle
Perle IOLAN SCG Manual

Perle
Perle IOLAN STG8 User manual

Perle
Perle IRG5520 Series User manual