Aus IFM-“QD” Interface Installation Manual December 2018 Version 1.2 RDCCO_2124_E_IN 4
NB: Must have a common –ve between the alarm panel and the PM1048
Bosch Panels: EDM Bosch Solution 16
The alarm panel must be programmed for Securitel communication back to
base.
The four digit account number must be programmed into the alarm panel.
DAS panels:
The panel must be programmed to use Smart Bus Mode (check keypad
compatibility) to ensure detailed events are sent back to the central station.ie to
report user and partition information.
Panels that are not programmed to use Smart Buss mode will report limited
events back to Base. i.e. general closing with no user ID.
The four digit account number must be programmed into the alarm panel.
Trigger an event on the alarm panel. Verify with the monitoring centre that a
tamper was received with the correct CID account number.
INSTALLATION MUST BE CARRIED OUT BY SERVICE PERSONNEL ONLY
Australian Standard AS2201 requires regular service by qualified and licensed
technicians and regular testing.
This product may not perform as expected if not correctly installed.
ANY LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES IS EXPRESSLY
DISCLAIMED. RADIO DATA COMMS AND PERMACONN LIABILITY IN ALL EVENTS IS
LIMITED TO, AND SHALL NOT EXCEED, THE PURCHASE PRICE PAID.
While every effort has been taken to ensure the accuracy of this document, Radio Data Comms assumes no
responsibility or liability for any errors or omissions. Radio Data Comms reserves the right to make changes to
this manual due to ongoing development.
Warning
Liability
Setup of Alarm Panel
Wiring of Alarm Panel to PM1048
Solution Panel 16 PM1048
Output 2 RX
Neg
DL & L Panel PM1048
DATA TX
CLK RX
Neg