manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Permobil
  6. •
  7. Controllers
  8. •
  9. Permobil ROHO Smart Check User manual

Permobil ROHO Smart Check User manual

Permobil Australia | 1300 845 483
[email protected]
permobil.com.au
ROHO®Smart Check®Set-Up Guide
1. Place the
ROHO
®Sensory Ready Cushion on the chair
with the air cells facing up. Place the nozzle of the
pump over the ination valve and overinate the
cushion until it begins to arch. Pinch the rubber nozzle of the hand pump
and turn to close the ination valve completely. Remove pump.
2. Transfer individual to chair and attach Smart Check to the
cushion. You will hear a “click” when the connection is secure.
3. Start Setup Process: Press the green
check button, when you see the red
down arrow illuminate, you are ready
to begin the Smart Check Set-up,
continue to step 4.
Note: If you see the red up arrow, when you press the check button then:
1) Make sure the disconnect is securely attached and,
2) Open the ination valve and press the green check button again. Repeat
until you see the red down arrow illuminate.
4. Press, but do not hold, the Setup Button. The red down arrow will ash.
Open the ination valve, release air
(approx 30-60 sec) and wait for the
ashing green light. To ensure an
accurate reading, the individual must
remain still.
5. When you see the ashing green light, close the ination valve.
The green light indicates that set up is
complete.
6. The individual can now check their
cushion ination rate daily by attaching the
Smart Check and pressing the Check Button.
Setup Button
Red Light
Remove air
Green Light
Setup is complete or
cushion is
within
the saved
ination range
Red Light
Add air
Check Button
Quick
Disconnect
Smart Check Setup
Before performing a new Setup,
clear the setting on Smart Check
by performing a Hard Reset as
instructed below.
Note: Smart Check can be
attached or detached when
performing the Hard Reset.
1. Make sure there are no steady
or ashing lights.
2. Simultaneously press and hold
the Check Button AND the
Setup Button for 5 seconds.
Each of the lights will ash one
time, indicating that the
previous setting has been
removed.
3. After Hard Reset is complete,
follow the Smart Check Setup
Instructions.
Hard Reset
Permobil Australia | 1300 845 483
[email protected]
permobil.com.au
ROHO®Smart Check®Set-Up Guide
1. Perform a Hard Reset.
2. Place the
ROHO
®Sensory Ready Cushion on the chair with the air cells
facing up. Place the nozzle of the pump over the ination valve and
overinate the cushion until it begins to arch. Pinch the rubber nozzle of
the hand pump and turn to close the ination valve completely. Remove
pump.
3. Transfer individual to chair and then perform a hand check as
follows:
a. Slide your hand between the cushion and the
individual. Lift the leg slightly and feel for the lowest
bony prominence and then lower the leg to a sitting
position.
b. Open the ination valve to remove air, keeping your hand
beneath the individual’s lowest bony prominence.
c. Release air until you can slightly move your ngertips,
as per Proper Cushion Ination Setting.
Close the ination valve.
d. Attach Smart Check to cushion. Press the green
Check Button, you will see either red light
illuminate. DO NOT add or remove air.
e. Press and hold the Setup Button for 4 seconds
until the green light illuminates, indicating your
preferred cushion ination setting has been saved.
Propercushioninflationsetting
½”-1”(1.5cm-2.5cm)
½”-1”
Optional Setup
Single Compartment
Hybrid Elite®
Single Compartment
High Prole Sensor Ready®
Single Compartment
Mid Prole Sensor Ready®
ROHO®Sensor Ready®Cushions
The world’s best personal electronic cushion security device!
With Smart Check® by ROHO®, you have ROHO’s industry leading skin protection plus you get real time feedback to
ensure proper cushion ination range with the push of a button.
How to Perform a Check
1. Individual sits in usual sitting
position.
2. Press the green Check Button.
3. Refer to table below..
Check Instructions
Light Status /
Causes Action
The cushion is
within saved
ination range No further action required
Weight maybe
unevenly distribute Perform a weight shift, then
press Check Button again
The quick
disconnect is not
securely attached
Check connection and press
the Check Button again
The cushion needs
more air
Open ination valve and add
more air with the hand
pump. Close ination valve
and press Check Button
again. Repeat as needed
The cushion or
quick disconnect
on the cushion has
a slow leak
See User Manual
The cushion has
too much air
Open ination valve and
remove air from the cushion
until green light illuminates

Other Permobil Controllers manuals

Permobil PJSM User manual

Permobil

Permobil PJSM User manual

Permobil R-net User manual

Permobil

Permobil R-net User manual

Popular Controllers manuals by other brands

HEIDENHAIN TNC 150 Service manual

HEIDENHAIN

HEIDENHAIN TNC 150 Service manual

Siko AG25 Translation of the original installation instructions

Siko

Siko AG25 Translation of the original installation instructions

NIVELCO UNICONT PM PMG-500 Quick setup guide

NIVELCO

NIVELCO UNICONT PM PMG-500 Quick setup guide

Chino LT830 Series instructions

Chino

Chino LT830 Series instructions

Honeywell R7426A manual

Honeywell

Honeywell R7426A manual

Siemens RLU2 Series operating instructions

Siemens

Siemens RLU2 Series operating instructions

Avonic CM-CON100 user manual

Avonic

Avonic CM-CON100 user manual

GESTRA NRR 2-60 Original Installation & Operating Manual

GESTRA

GESTRA NRR 2-60 Original Installation & Operating Manual

DaySequerra NLC5.1ST user manual

DaySequerra

DaySequerra NLC5.1ST user manual

AvL Technologies AAQ Maintenance Server Setup & operation guide

AvL Technologies

AvL Technologies AAQ Maintenance Server Setup & operation guide

WAMGROUP TOPERX ANSY 9300 maintenance

WAMGROUP

WAMGROUP TOPERX ANSY 9300 maintenance

IAI MSCON instruction manual

IAI

IAI MSCON instruction manual

TDE MACNO OPDE Installation

TDE MACNO

TDE MACNO OPDE Installation

Comat Comat BoxX Programming manual

Comat

Comat Comat BoxX Programming manual

Lincoln Electric AutoDrive 19 Operator's manual

Lincoln Electric

Lincoln Electric AutoDrive 19 Operator's manual

BROVIND CFF Series User and maintenance manual

BROVIND

BROVIND CFF Series User and maintenance manual

Spirax Sarco LCR2250 Installation and maintenance instructions

Spirax Sarco

Spirax Sarco LCR2250 Installation and maintenance instructions

DecaLED Touch Panel DMX 4 manual

DecaLED

DecaLED Touch Panel DMX 4 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.