PetNovations CatGenie 120 User manual


Set at the time you want your CatGenie to wake up.
In In 1 & 2, you MUST lock in your start-time.
Press & Hold AutoSet for 4 seconds.
Cong
ratulations
You own the new 120 model.
The 120 has new features suggested by current CatGenie 120 owners.
Addendum to the CatGenie 120 Owners Manual
®
Your CatGenie stays on the Cat Activation mode you selected until you change it.
To CHANGE or DE-ACTIVATE
any Cat Activation Mode: Press & Release the Auto Set Button until the LEDs go out.
Both 14 & 24 hour Cat Activation options double the number of SaniSolution Cartridge washes from 120 to 240.
If another cat uses the CatGenie during a Delay, the unit adjusts to allow more wait-time before starting.
TIP: Make sure your cats are using their CatGenie before setting Cat Activation.
14.HOURCATACTIVATION
14 Hrs Awake / 10 Hrs sleep.
Sleeps day or night. You decide.
#1
10-Min Delay
before cleaning.
Suitable for
1 cat or
cats who will only use
a clean box everytime.
Press & Release
AutoSet Button until
#1
+ CAT LEDs light
#2
30-Min Delay
beforecleaning.
Suitablefor
2-3cats
whogotogether;don’t
mindausedbox.
Press&Release
AutoSetButtonuntil
#2
+CATLEDslight
!
24.HOURCATACTIVATION
24 Hrs Awake / 0 Hrs sleep.
Always ready to clean after use.
#3
10-Min Delay
before cleaning.
Suitable for
1 cat or
cats who will only use
a clean box everytime.
Press & Release
AutoSet Button until
#3
+ CAT LEDs light
#4
30-MinDelay
beforecleaning.
Suitable for
2-3cats
whogotogether;don’t
mindausedbox.
Press&Release
AutoSetButtonuntil
#4
+CATLEDslight
Do at any time to begin the 24 hour setting.
Press & Hold AutoSet Button for
5 seconds then release.
CatGenie Gives You 4 Ways to Customize Cat Activation
To keep running properly and efficiently, every appliance requires a little maintenance.
The CatGenie has a Water Sensor Guide that needs cleaning every 3 months.
The Water Sensor Guide is a 4” double bar of clear plastic located under 1) the Processing
Unit. Lift the Unit, 2) see the ends of the Guide, pull it out and 3) wipe its triangular tip with
your fingers or a damp towel until shiny. See page 16 of the Owners Manual for full details.
TIP:
Cleaning the Guide takes no time and saves trouble. A dirty Guide sends a false signal,
which causes the CatGenie to go into a safety mode that won’t allow it to fill with water. This
means it won’t clean until you clean the Water Sensor Guide.
When you
HEAR
one beep going on & off for 30 seconds every hour AND
you
SEE
the #1 LED plus the ERROR LED blink together on & off every 3 seconds,
you know you better clean your Water Sensor Guide.
Your CatGenie needs only
10 seconds of maintenance every 3 months...
© 2011, PetNovations, Inc. USA
1
2
3
andif you don’t takecare
of your CatGenie, it warns you until you do.

IMPORTANT SAFETY INSTRUCTIONS
To Prevent Risk of Fire, Electric Shock, or Injury to People and Pets.
TO PREVENT FIRE or shock hazard, do NOT expose the
CatGenie Processing Unit to rain or sources of splashing
water. Do NOT operate the CatGenie with wet hands.
READ ALL INSTRUCTIONS BEFORE INSTALLING
AND USING YOUR CATGENIE. USE THE
CATGENIE ONLY FOR ITS INTENDED PURPOSE.
All modifications or changes not explicitly described or
approved of in this manual could void your Warranty.
WARNING: Basic safety precautions must and should
always be followed to reduce the risk of personal injury.
ON SAFETY
Should any solid object fall on or into the Processing Unit or should
liquid penetrate the Processing Unit, unplug the CatGenie and have
it checked by qualified personnel before using.
Unplug the CatGenie Electric Cord from the outlet before
attempting to clear a jam or remove an object from the Hopper’s
processing area. Do NOT put fingers or hands into the Hopper
opening while the CatGenie is operating.
ON POWER SOURCES
Before operating the CatGenie, check that your local power
supply is identical to the CatGenie operating voltage, which is
120VAC. See complete specifications in Gray Box on right.
UNPLUG the CatGenie FROM ITS ELECTRIC OUTLET before
cleaning the Processing Unit or washing any other CatGenie parts.
NOTE: When you remove the Processing Unit from its Base,
current is still going to it, so unplug the Genie Electric Cord first.
If you are not going to use the CatGenie for an extended
period of time, disconnect the CatGenie from the electric outlet.
When disconnecting the CatGenie electric power cord, pull
the PLUG. NEVER pull the cord. A damaged or defective AC
power cord should be changed at a qualified service shop.
ON PLACEMENT
Position the CatGenie in a place with adequate ventilation to
prevent heat build-up and to prolong the life of the CatGenie.
Do NOT place CatGenie near heat sources, or in a place
subject to direct sunlight, excessive dust, or mechanical shock.
Do NOT place anything on top of or behind the unit.
This may block ventilation holes and cause malfunction.
Do NOT install or store the CatGenie where it could be
exposed to rain or splashing water.
See the Simple Setup Guide for site selection options.
ON OPERATION
Before connecting the CatGenie to the power source, be sure
to read this manual. NEVER, under any circumstances, connect
the CatGenie to a power source unless the CatGenie Processing
Unit is properly seated and secure in its slot in the Base.
Do NOT operate CatGenie with wet hands. Follow all
instructions and warnings in all CatGenie Manuals.
ON CLEANING
Clean the Processing Unit and Control Panel only with a soft
damp cloth slightly moistened with water. NEVER immerse it in
or spray it with water.
Do NOT use any type of abrasive pad, scouring powder
or solvent such as alcohol or benzene. See Cleaning the
CatGenie on page 16 for further instructions.
If you have any questions or problems concerning your
CatGenie, please contact our technical support staff at:
1-888-735-3927
PetNovations, Inc. cannot assume responsibility for any and
all possible damage if CatGenie is inappropriately operated
or used for a purpose other than that for which it is intended.
While PetNovations, Inc. reserves the right to change design
and specifications without notice, we do alert our customers
about upgrades and product improvements.
To receive news of upgrades, improvements, and
special offers, register your Warranty at... catGenie.com
CatGenie SPECIFICATIONS
for NORTH AMERICA
•Power Requirements: 120VAC, 60Hz (15A Fused)
•Power Consumption: 20W (Cleaning Cycle-17Minutes)
1200W (Drying Cycle-17 Minutes)
•Approximate Weight: Total CatGenie: 25 lbs.
(Includes Processing Unit, 11 lbs. Base Unit, 14 lbs)
•Supplied Accessories: Utility or Laundry Room
T-Adapter, Bathroom or Powder Room T-Adapter,
SaniSolution Cartridge, and Washable Granules.
2
www.catGenie.com 1-888-735-3927

Safety Instructions.............................................
CatGenie Specifications….....…........................
Customer Support….....….................................
QUICK FIXES….....….......................................
CATGENIE ANATOMY.....................................
CatGenie FAQs….....….....................................
CONTROL PANEL…........................................
•Program Cat Activation..................................
•Program Auto Start .......................................
•Program Child Lock…...................................
SUPPLIES.........................................................
•Washable Granules...…................................
•SaniSolution …..............................................
CATGENIE SETUPS.........................................
•Bath & Laundry Rooms.................................
•Correct Setup Examples...............................
•Spare Parts...................................................
TROUBLE SHOOTING ...................................
•Errors 1, 2, 3, 4 Beeps & Lights ...................
•Errors without Warnings................................
CATGENIE MAINTENANCE.......................….
•Machine Cleaners ........................................
•How to Clean the Water Sensor...................
•Clear Clogs...................................................
•Technical Modes............................................
FCC Notice & Warning…...............................…
90-Day, Money-Back Guarantee.......................
2-Year Warranty……..........................................
CUSTOMER SUPPORT
Please call or email Customer Support if you see visible
damage to your CatGenie or if you have cat adjustment
problems. We are happy to assist you with ANY question
or issue that you may have concerning your CatGenie.
Call: 1-888-SELF-WASH •1-888-735-3927
Email: [email protected]
Visit: www.CatGenie.com
12O OWNER’S GUIDE
TABLE OF CONTENTS
How do I mute
warning beeps?
Press &
Release
the Start/Pause Button.
CatGenie QUICK FIX
Many problems are caused by the
following.
Check & Correct.
1. Make sure that your cold water supply is turned on
and that the knob is turned on all the way.
2. Check electric power. Plug in electric cord. Check that
the Processing Unit is correctly placed in its slot.
3. Clean the Water Sensor. Remove the Processing Unit.
Pull out Water Sensor, clean its tip, replace. See page 16
4. Clear Hopper. Unplug electric. Remove Hopper Cover.
Remove obstruction. Replace cover. Plug in. See page 16
5. Straighten bent or crimped CatGenie water supply
and drain hoses.
TROUBLE SHOOTING
See Pages 12, 13, 14, 15
3
www.catGenie.com 1-888-735-3927
2
2
3
3
4-5
5
6
7
7
8
8-9
9
9
10
10
10
11
12-15
12-13
14-15
16
16
16
17-18
19
20
20
20
My
CatGenie
Serial Number
Serial Number is on the back of the Processing Unit.

4
www.catGenie.com 1-888-735-3927
ANATOMY OF THE CATGENIE 12O
SaniSolution
12O Cartridge
Dispenses exact amount
of sanitizing fluid
Genie Eyes
Sees when cat is in the
Bowl. Won’t start Cycle
for 10 minutes
Control Panel
Use to program
Start Cycle. Beeps
& Blinks warn of errors
Washable
Granules
Non-absorbent, shed
liquids, Granules never
need changing
Processing Unit
It’s the CatGenie Brain.
Holds motors, solution
pump unit, electronics
Genie
WaterHose
Connects to cold
water supply line in
bath or laundry
Genie Electric Cord
Plugs into AC power.
OnlyuseaGFCIoutlet
Genie DrainHose
Drains into toilet or waste
pipe in laundry or utility room
Water Spout
Fresh water flows
into Bowl
Dryer Spout
Hot air blows out
and into Bowl
DrainHook
Attaches to Genie
DrainHose for use
over toilet rim
Genie Hand
Multi-functional tool scoops
solids. Scrubs and scours
Granules, itself, and inside
Bowl. Sifts through Granules
for complete drying
Hopper
Chamber where Impeller
macerates waste
Bowl
Where cat feels at home in
the cat-comfy Granules
Brim
Encircles the Bowl;
attaches to Base
Base
Very bottom of
CatGenie
Hopper Cover
Store GenieHand,
Hides Hopper
Impeller
Water
Sensor
Inside
Hopper
Red Drain
Washer
Hair
Cutter
Ring

SaniSolution
Smart Cartridge
Processing Unit
Hopper Cover
GenieEyes
Cat Sensor
GenieHand
Bowl
Brim
Hopper, Impeller,
Red Drain Washer
Water Sensor
Genie Water Supply Line
Genie Electric Cord
Genie DrainHose
IS THE SANISOLUTION CLEANER SAFE FOR MY CAT?
Yes, SaniSolution is safe for cats. Its ingredients are like those used by
veterinarians to disinfect their operating areas. Liquid in the Cartridge is
highly concentrated. In this form, it is safe as long as it is in the Cartridge.
HOW LONG DOES THE SANISOLUTION LAST?
On Cat Activation,one SaniSolution Cartridge is good for 240 washes.
On Auto Set, one is good for 120 Cycles. ALWAYS keep extra Cartridges
on hand. The price of SaniSolution equals the yearly cost of cat litter,
yet it’s just a fraction of the size and weight of litter.
DOES THE SANISOLUTION DISSOLVE OR LIQUEFY SOLIDS?
No. The solids are turned into wastewater by the action of the Impeller,
which is inside the Hopper. The SaniSolution washes and disinfects the
Washable Granules, GenieHand, and Bowl.
CAN I REFILL THE SANISOLUTION SMART CARTRIDGE?
No, the Cartridge cannot be refilled. The Smart Cartridge’s unique
mechanism dispenses the exact amount of solution used for each of the
3 washes per Cleaning Cycle, as each wash requires a different quantity.
The SaniSolution washes away odor-causing materials, aids in drying,
and protects the CatGenie mechanism. The exclusive SaniSolution
formula was tested and approved by veterinarians for cat safety.
IS THE CATGENIE GREEN?
The SaniSolution Smart Cartridge replaces the use and need for cat litter.
Unlike any type of litter, the SaniSolution, the Cartridge, and the Washable
Granules are environmentally safe, biodegradable and/or recyclable.
WHAT HAPPENS IF MY CAT IS IN BOWL DURING CLEANING?
The CatGenie has sensors, GenieEyes, which delay the cleaning cycle
until your cat is safely out of the CatGenie.
WILL MY WATER BILL INCREASE BY USING THE CATGENIE?
Your water bill should not have any significant increase. Running a
CatGenie is equal to a few additional toilet flushes per day.
WHERE DOES WASTEWATER GO WHEN IT LEAVES THE UNIT?
Wastewater drains safely out of your home into sewer pipes. When used
in a bathroom, the GenieHose hooks over the toilet rim; waste drains into
toilet. When used in a laundry, waste goes into the Washer’s drain pipe.
IN A LAUNDRY ROOM, COULD WASTE WATER GET ON CLOTHES?
No. When properly hooked into the washing machine drain pipe, waste
water can not touch laundry. The drainpipe connects directly into sewer
or septic tank. NOTE: the length of the washer’s drain hose inside its
waste pipe must be less than 5 inches.
IN A BATHROOM, CAN THE TOILET BE USED DURING A CYCLE?
Yes. The CatGenie does not interfere with toilet use. Toilet seats have feet
(check yours) so the DrainHose Hook can not be crushed.
CAN A TOILET OVERFLOW WHEN WASTE WATER GOES INTO IT?
No. Water in a toilet automatically lowers to its preset level and will
not overflow unless your toilet is clogged.
WHAT HAPPENS IF SOLIDS STICK TO THE GENIEHAND?
During all three washings, the GenieHand gets scrubbed clean by the
action of water, SaniSolution, and Washable Granules.
DO THE WASHABLE GRANULES
™
ABSORB?
No, the cat-safe Washable Granules are completely non-absorbent. Unlike
traditional litter, the Washable Granules are thoroughly washed each
cleaning cycle. Their function is to fulfill your cat’s need to dig and cover.
WHAT HAPPENS IF WASHABLE GRANULES ARE SWALLOWED?
The Granules are non-toxic for both cats and humans and can easily pass
through their respective digestive systems.
CATGENIE FAQs
5
www.catGenie.com 1-888-735-3927
Base
Genie
Scrubber

CUSTOMIZE THE RUNNING of YOUR CATGENIE 12O
You have 3 Freedoms of Choice
CARTRIDGE LED INDICATOR
Lights when Cartridge has 10 Cycles
left. Stays lit until Cartridge is empty
and replaced. Blinks if
non-empty Cartridge
is removed.
CONTROL PANEL
Your CatGenie communicates with BEEPS & BLINKS.
START-PAUSE BUTTON
Press & Release to
• Manually START a Cycle
• PAUSE a Cycle,
• RESTART a paused Cycle
• Mute Warning Beeps
CHILD LOCK
LED & BUTTONS
Prevent accidental starts. Press and
Hold both BUTTONS for 3 seconds until
Child Lock LED lights. That LED stays lit
while in Child Lock mode.
AUTO SETUP BUTTON
Use to Program
CAT ACTIVATION OR to Pre Set
• TIMES of day you want to clean
• NUMBER of cleans per day.
CARTRIDGE LEVEL CHECK
LEDs & BUTTONS
Tell how many wash cycles remain.
Press and Release both BUTTONS.
LEDs light under the
10+ to 100+ panel.
ERROR LED
Error LED Blinks and unit Beeps when
you have a Cleaning Cycle problem.
Beeps sound Error Number. See LEDs
1 through 4 for which Error. Go to
Trouble Shooting page 12 to correct.
LEDS 1
THRU 4 & CAT
perform 3 functions:
READ CARTRIDGE
LEVEL CHECK
LEDs light under the
10+ to 100+ panel.
SHOW DAILY CYCLES
LED lights the number
of Cycles pre-set for
daily auto start.
IDENTIFY ERROR
LED 1, 2, 3, or 4 light.
Lit LED tells you
which Error.
1
3
5
6
Cat Start
In Cat Activation mode,
CatGenie cleans after
your cats use it. So your
CatGenie never has a
chance to get dirty, smelly,
or full of germs. It’s the
most efficient setting because the
12O Cartridge adjusts the doses
of SaniSolution to 24O. It’s like
having two Cartridges in one. Tests prove
that in Cat Activation mode, the CatGenie
runs 10 times more efficiently.
Auto Start
Allows you to run the
CatGenie from 1 to 4
times a day depending
on the number of cats.
Runs every 24, 12, 8,
or 6 hours per day
depending on whether you program
your CatGenie to run 1, 2, 3, or 4
times a day. Cartridge on this
setting dispenses 12O doses
of SaniSolution.
Push Start
Push the start button
anytime you want to
clean the CatGenie.
This is handy as an
addition to other start
options. Use this
option when CatGenie is in Sleep Mode
or between Auto Start Cycles. Makes
checking for health issues easier.
Cartridge dispenses 12O doses
of SaniSolution.
4
6
www.catGenie.com 1-888-735-3927
2
7

HOW OFTEN SHOULD I RUN
MY CATGENIE ON AUTO SET?
One Cat..........
Two Cats........
Three Cats.....
ABOUT AUTO START
With Auto Start, you preset the CatGenie to clean from 1 to 4 times during a 24 hour period.
Once programmed, the Unit automatically STARTS at the pre-set Cleaning Cycle times.
Because Auto Start runs on a timer, you would program your Auto Start Setup at one of the times
that you actually want your CatGenie to start a Cleaning Cycle. For example, if you want your
CatGenie to run at 2 am and 2 pm, you must program Auto Setup at either 2 am or 2 pm. If using
Auto Start, it is important to follow the chart at left and to observe when your cats do their business
so as to coordinate cleaning times.
HOW TO PROGRAM AUTO START SETUP.
STEP 1. Decide how many times a day and what times of day that you want your
CatGenie to clean. Pick a time and do the following.
STEP 2. To set the NUMBER of auto-timer washes (one to four) per day,Press & Release the
Auto Setup Button for EACH number of Cleaning Cycles that you want to run every day. For once
a day, Press & Release once. For twice a day, Press & Release twice. For three times a day, Press
& Release three times, etc. DON’T HOLD the button down.
A Daily Cycle LED lights for the each number of times set. One LED lights for once a day.
Two LEDs light for twice a day. Three LEDs light for three a day, etc. IF YOU MAKE A MISTAKE,
Press & Release the Auto Setup Button until all LEDs go out, then repeat Step 1.
STEP 3. To set the TIMES that you want the CatGenie to run auto timer washes,
firmly PRESS & HOLD the Auto Setup Button for 4 seconds, then Release. CatGenie responds
with 3 Beeps while 4 Daily Cycles LEDs flash on and off, and then go out. The number of washes
you set stays lit. Once Auto is programmed, the CatGenie starts a cycle in 30 seconds.
CAUTION: It is important to run your CatGenie one to two times a day per cat.
Not running your CatGenie enough can cause clogs. Best to run a wash cycle
soon after your cats go. Don’t let solids accumulate and harden.
Clean 2 times per day
Clean 4 times per day
Clean 6 times per day
ABOUT CAT ACTIVATION
With Cat Activation, the CatGenie cleans 10 minutes after your cat does his business.
If another cat needs to use the potty, the Unit resets and delays for another 10 minutes, etc.
The Unit will not start if a cat is using it. The Genie Eyes watch for that.
When set for CatActivation, the Cartridge switches from 120 doses of SaniSolution to 240 doses.
Because CatGenie cleans and flushes the mess immediately, it needs less Solution per wash.
Cat Activation uses two modes: 14 hours of Active Mode and 10 hours of Sleep Mode. In Active
Mode, the Unit cleans after cats use it. While in Sleep Mode, the Unit does not run. However you
can choose to press the Start Button to clean anytime during those 10 hours. When CatGenie
wakes up, it automatically cleans itself if any cat used it while it was sleeping.
HOW TO PROGRAM CAT ACTIVATION.
STEP 1. Decide when you want the CatGenie to wake up from its 10-hour sleep.
That’s the perfect time to do the following.
STEP 2. Press & Release the Auto setup Button until the “CAT” LED lights up.
STEP 3. Firmly PRESS & HOLD the Auto Setup Button for 4 seconds, then Release.
CAT LED. Once set, your CatGenie responds with 3 Beeps and the CAT LED flashes on.
The Cat LED stays on as long as you have Cat Activation in Active Mode. The CAT LED blinks
fast for the 10 minute wait after cats use. In Sleep Mode, the Cat LED repeatedly blinks on and
OFF to indicate that the Unit is sleeping.
To DE-ACTIVATE:Press & Release the Auto Setup Button until CAT LED goes out.
SHORT CUTS
Saves You a Setup Step
•Want to add more daily washes?
Just Press & Release the Auto Setup
Button at any time until the number
of cycles that you want lights.
•Want fewer daily washes? Press &
Release Auto Setup until all LEDs go
out. Then Press & Release Auto Setup
until your number of Cycles lights.
•Want to just change the wash time?
At the new time, Press & Hold Auto
Setup for 4 seconds then Release.
See Page 8 for info on PAUSING a CLEANING CYCLE and about POWER FAILURES
7
www.catGenie.com 1-888-735-3927

MORE ABOUT AUTO START
What’s the best time to run your CatGenie?
Cats usually defecate within half an hour after eating a main meal. Cat experts tell us that cats
sleep 15 to 20 hours a day (70% of their day). Keep a schedule of your cat’s behavior.
Choose running times that won’t interfere with your cat’s routine.
NOTE: If your cat is using the Bowl at the same time that the CatGenie is set to clean,
the GenieEyes Sensor alerts the CatGenie to delay the Cleaning Cycle. After a cat, and any
cats that follow, leave the Bowl, the CatGenie waits 10 minutes before starting a Cycle.
MANUAL START OPTION
To START a non-programmed Cleaning Cycle, Press & Release the Start Cycle/Pause
Button. Use this option if you want to check your cat’s eliminations for health reasons
or if it is between running times and you want your CatGenie cleaned.
CHILD LOCK.RECOMMENDED to keep
Cats and Kids from starting a wash cycle accidentally.
To Activate Child Lock: Press the Start/Pause Button and the Auto Setup Button
at the same time and HOLD for 3 seconds then release. CatGenie Beeps and the Child Lock LED
lights to confirm that you have activated the Child Lock feature. The CatGenie Beeps if someone
touches a button when Child Lock is active.
To Deactivate Child Lock: Press the Start/Pause and Auto Setup Buttons
at the same time and HOLD until Beeps stop and Child Lock LED goes out. Then release.
NOTE: The Child Lock LED lights to confirm that you have activated the Child Lock feature.
SUPPLIES
*MORE EARTH FRIENDLY.
BIODEGRADABLE & RECYCLABLE
WASHABLE GRANULES & CARTRIDGE
so you won’t feel guilty when the Cartridge is empty.
Most plastics take thousands of years to break down and some can never biodegrade! CatGenie
Granules and Cartridges have a unique additive that enables plastic-loving bacteria to break down
the plastics. The Cartridge Cases biodegrade in less than a decade. The Cartridge plastic can also
safely mix with other recycled plastics. Any lost Washable Granules biodegrade within 9 months in
Septic Systems and two years in landfills.
GENIE EYES SEE CAT IN BOWL
BRUSHING YOUR CAT HELPS
CAT&CATGENIE
AUTO SETUP TIME
EXAMPLES.
If you want it to run
once a day at 8:15am...
program it at 8:15am
3 times a day at 6am,
2pm, 10pm... program
at any of those times
4 times at 7am, 1pm,
7pm, 1am. Program at
any of those 4 times
HOW to PAUSE
a Cleaning Cycle.
• To PAUSE a Cleaning Cycle (Auto or Manually initiated) Press & Release the
Start /Pause Button. When in PAUSE, the CatGenie will TICK
• To restart, Press & Release Start /Pause again. If left in PAUSE mode, the Cycle
resumes in 10 minutes. While in PAUSE, the CatGenie makes a TICKING sound.
POWER FAILURE ALERT.
CatGenie alerts you when you have a power failure, by interrupting the lit LEDs.
So your settings for Cat Activation and Auto Start could be off because the Timer
delays start times for as long as the power is out. You can forgo resetting if a brief
black out or a quick unplugging occurred, as the Start Time is just a few minutes
later. If power is out for several hours and you want to reset, refer to page 6.
8
www.catGenie.com 1-888-735-3927

KEEP FILLED TO THIS LEVEL
NEVER MIX IN OR USE CAT LITTER
WASHABLE GRANULES never need changing.
While the Washable Granules never need changing, they do need to be replenished. Just add
Granules when the amount falls below the fill-level line, which is indicated by an indentation inside
the Bowl. It is important to keep the Granules filled to that level. Always have an extra package
of Washable Granules on hand.
WARNING: NEVER, under any circumstances, use or mix cat litter with the
Washable Granules in your CatGenie. Doing so can cause severe damage to your
CatGenie and will void your Warranty. Just a few grains of clumping litter clogs pipes,
ruins the Water Sensor, and causes endless errors.
SANISOLUTION 12O CARTRIDGE
is the key to CatGenie operations and cat protection.
The 12O Cartridge keeps the concentrated SaniSolution liquid safely contained. Its software
program accurately dispenses, monitors, and controls the proportion of Solution to water for the
maximum safety of your cats and the optimal operation of your CatGenie. When empty, replace
the 12O Cartridge or your CatGenie won’t function. Always have extra 12O Cartridges on hand,
so your CatGenie can work without interruption.
WARNING: ONLY USE THE TRANSLUCENT SILVER, CatGenie SANISOLUTION
CARTRIDGES in your CatGenie 12O MODEL. Do NOT buy or use any with brass bars.
CHECK NUMBER of WASHES in CARTRIDGE.
NOTE: If CHILD LOCK is on, turn off by Pressing the Start and Auto Buttons at the same time.
HOLD until Beeps stop and Child Lock LED goes out. Then Release. Now you can check the...
Cartridge Level: Press Start/Pause Button and Auto Setup Buttons at the same time.
HOLD for ONE second then release. The LEDs under the 10+ to 100+ panel light up to the nearest
number of washes remaining in the Cartridge. You will have 3 seconds to view the read out.
NOTE: If you always use Cat Activation, double the number indicated by level check LEDs.
REMEMBER to reconnect CHILD LOCK. Press Start/Pause Auto Setup Button together.
HOLD for 3 seconds then Release.
HEED THE 12O CARTRIDGE WARNINGS.
Low Level: When 10 of the SaniSolution portions remain in the Cartridge, the Cartridge
LED lights and stays lit. Check that you have an extra Cartridge or ORDER IMMEDIATELY.
Critical Level: When 3 wash cycles remain in the Cartridge, the Cartridge LED lights and
a repetitive, One-Beep Warning sounds for 30 seconds once every hour. To stop the Beep, Press &
Release the Start/Pause Button. The Cartridge LED stays lit to remind you that only 3 wash portions
remain. TIP: If you will be away when the Cartridge is scheduled to run out, switch to a full
Cartridge until you return. Then switch back to the almost empty Cartridge.
Empty Cartridge: When empty, the Cartridge LED blinks and a repetitive, 2-Beep
Warning sounds for 30 seconds once every hour. To mute the Beep, Press & Release the
Start/Pause Button. The LED blinks and CatGenie can’t do a wash. If you try to start a Manual
Cycle, the 2-Beep Warning reactivates. Just add a fresh Cartridge and all will be well.
No Cartridge: Cartridge LED and Error LED alternate blinks. CatGenie won’t start.
Replace to activate. Incorrect Cartridge placement also causes Beeps. Put Cartridge in correctly.
The notch goes to the rear. CatGenie needs a correctly placed Cartridge with SaniSolution to work.
ABOUT SANISOLUTION.
SaniSolution is safe and non-toxic for cats and humans when properly used in the CatGenie.
Ingredients are same as disinfectants used by veterinarians to sterilize exam and operating areas.
WARNING: In its concentrated state, the Solution may be irritating to skin and
eyes, so avoid contact. Do not ingest. Keep out of reach of children. In case of skin or
eye contact, wash with copious amounts of water. If swallowed get medical advice
or call this emergency number: 1-800-424-9300.
Cartridge
Notch
points
towards
the BACK
of the
CatGenie
NEVER remove the Cartridge
while CatGenie is cleaning
Removing the Cartridge during a cleaning cycle
will NOT extend Cartridge life. Removal causes
CatGenie to not clean thoroughly, not dry
completely, and not destroy bacteria and odors
effectively. Removal before a cleaning cycle
causes the CatGenie to not run at all.
NOTE: The Cartridge-User Counter
registers usage at the start of each cycle.
DO NOT REMOVE WHITE NIPPLE on bottom
of Cartridge. Solution floods out and ruins the
Processing Unit. VOIDS YOUR WARRANTY.
9
www.catGenie.com 1-888-735-3927

SETUPS.
BATH or POWDER ROOM
1. Shut off cold-water line on toilet or sink and
unscrew water flex hose. 2. Attach the 3/8” T-Adapter to flex hose and
to cold-water line. 3. Screw the Genie Water Supply to the T-Adapter.
Turn cold water on. Check for leaks or drips. 4. For toilet use only,
connect the Genie Hook to the Genie DrainHose. Push until the white tip
on the Hose is all the way into the Hook. 5. Put the Genie DrainHook
over the toilet rim. Plug the Genie power cord into a GFCI electric outlet.
LAUNDRY or UTILITY ROOM
1. Turn off the laundry’s cold-water supply valve. 2. Unscrew your washing
machine’s cold-water supply hose from its valve. 3. Attach washer hose to
supplied 3/4” T-Adapter, then screw the Adapter onto the cold-water valve.
4. Screw the Genie Water Line onto the T-Adapter, then turn on cold water.
5. Put Genie DrainHose into Washer’s waste pipe with Washer’s drain hook.
Don’t squeeze hoses. 6. Avoid clogs and overflow. Washer drain hose must
be less than 5” inside waste pipe. Plug power cord into a GFCI electric outlet.
See Simple Setup Guide for Complete Directions.
3. If the washer hose with its
guard still won’t go into the drain,
move the washer guard up the
hose about 2 inches. Then put the
washer hose into the drain.
1. If the GenieHose and washer hose won’t fit easily into
the drain, remove both hoses. Put the GenieHose in first,
then add the washer hose.
2. If the washer hose has a guard, hold the guard and
hose tightly together and push washer hose into the drain.
124
5
3
FITTING TWO HOSES INTO ONE LAUNDRY DRAIN:
4. Another option is to put the hoses in together
with the GenieHose a little ahead of the edge of
the washer hose.
5. Push both hoses in until they are firmly
secured inside the drainpipe.
RIGHT & WRONG SETUPS:
LAUNDRY DRAIN
YES. Do run Genie DrainHose along floor
for about 2’, and then up to the laundry
drain pipe.
NO. Do not run the Genie DrainHose straight
up to the laundry drainpipe.
FLOOR DRAIN
YES. Do run DrainHose out and up
12" high, then down along floor to drain.
Level CatGenie if floor slopes to drain.
NO. Do not run DrainHose down on the
floor directly to the drain.
COILING the DRAIN HOSE
YES. Do make wide, unkinked coils if you need to
store the DrainHose under the Base. Run the hose
through the notches in the Base.
NO. Do not make tight coils or kinks in the Genie Hoses.
NO. Do not pinch or squeeze Hoses.
10
www.catGenie.com 1-888-735-3927
12
23
45
1
345
NO
YES
YES
NO
NO
NO
YES
2
2

11
www.catGenie.com 1-888-735-3927
HOW TO GET INSIDE YOUR CATGENIE if you need to replace a part.
WARNING: Unless a Manual instructs otherwise, always unplug the Genie power cord before you work on your CatGenie.
Be sure to plug it back in you’re finished. Removing the Processing Unit also interrupts power.
If working on the Processing Unit, first unplug the power cord.
the GenieHand. Push Arm and Clip back into the opening. To remove
Brim, push on Black Button for leverage as you pull up the Brim back.
Put aside. Hopper is accessible for removal if necessary. To get to the
Base, remove the Bowl of Granules. Set aside where cats can’t use.
HOW TO REPLACE PARTS. Spares available under Genie Base. Or from us.
RED WASHER:
Attaches to the bottom of the
Hopper and connects to the
DrainHose. The Red Washer is a
Critical piece. It prevents waste-
water leaks. It’s important that it
is not squeezed or defective.
Make sure that it is securely in
place on the Hopper. Keep it
lubricated with baby oil
or liquid soap.
ORANGE NIPLET:
Located at the bottom of the Processing Unit. The Niplet
prevents the SaniSolution from drying out and clogging the
white dispenser Nozzle to which it is attached. To check if
it’s OK, unplug CatGenie. Carefully lift the Unit from its slot.
To clean Niplet, squeeze out clumped Solution. Then wash
with warm water. If missing, get one from Spare Parts.
Put Niplet onto the white Nozzle. Clean Unit slot on the
Brim. Wipe bottom of Unit with a soft cloth. Carefully and
securely put Unit back into its slot. Plug in the CatGenie.
3/4” T-ADAPTER WASHER
for LAUNDRY SETUP:
Check if Lock-Nut side of
the T-Adapter has its Black
Washer. If missing, purchase
at a hardware store.
Or call us toll free at
1-888-735-3927.
SPACER DISCS:
If you have excessive loss of Granules under
the Brim, Spacer Discs are provided in the Spare Parts
Kit under the Base. Follow directions.
Add just one Disc to the Knob in the center of
the Base, on which the Bowl rotates. Put the CatGenie
back together. Before adding the Processing Unit, spin
the Bowl to check that Bowl moves easily. Run a
Cycle to test that all works.
WATER SENSOR:
If the Sensor Tip gets
scratched or damaged
it won’t work. Replace
with the extra Sensor
in the Spare Parts Kit
under the Base.
Spare Parts Kit is under the Base.
Keep it there until needed.
To take apart your CatGenie, move the CatGenie away from the
wall. Keep the DrainHose in the toilet or drainpipe. Take off the
Hopper Cover. Remove the Processing Unit and place it upright on
a towel on the floor. Lean the Unit securely against the wall. Unclip

SEE & LISTEN for WHICH ERROR. OBSERVE SYMPTOMS. Press START to Stop Beeps.
TROUBLE SHOOTING.
TIP: To avoid 90% of problems, set your CatGenie on Cat Activation.
ERROR 1. Hear Beeps, Error LED & LED 1 lit. Dirty Water Sensor or a Clog.
ERROR 2. Hear Beeps, Error LED & LED 2 lit.
Cycle Stops; there is
a water problem.
A: NO WATER. Don’t unplug electric or remove the Processing Unit. Press Start Button to silence Beeps.
•
The water supply valve from laundry or bathroom line is turned off. Turn on cold water supply line valve all the way on.
•
Genie Water Hose is either not connected to home’s water supply or to back of
Processing Unit. Connect Genie Water Line to cold-water line or to Processing Unit.
•
CatGenie Water Supply Hose is bent or crimped. Loosen coil, un-crimp GenieHose.
Once Ais fixed, Press Start Button for 4 seconds and Release. Cycle should continue.
B. NOT ENOUGH WATER: Don’t unplug electric or remove Processing Unit.
•
Water drains out as it’s filling the Bowl. Raise the Genie DrainHose at least one
foot above the GenieBase. Only need a short run. See photo at right.
•
Water pressure is low. Do NOT run washer, dishwasher, or shower at the same time
as the CatGenie. Water valve should be turned all the way on.
•
Sediments in home’s water pipe clogged GenieHose filter. Turn off water supply valve. Wait
5 minutes. Unscrew the GenieHose from the T-adapter, and dump Hose water down the Hopper
or in a bucket that’s lower than the Bowl. Pull CatGenie away from the wall. Unscrew Genie Water
Supply line. See the mesh filter. If dirty, remove with a needle-nose pliers and clean. Replace filter.
Screw Hose back onto Processing Unit. Screw Hose onto T-adapter, turn on water supply valve.
When Bis fixed, Press the Start/Pause Button for 4 seconds and Release. Cycle should continue.
C. TOO MUCH WATER:
•
Water Sensor is dirty. Remove Processing Unit. Pull out Water Sensor from top of Hopper.
See page 16 for cleaning details. Carefully replace the Water Sensor securely in its slot. Clear
off any debris inside the Processing Unit slot before replacing it. Cycle should continue.
•
CatGenie is not level. Adjust position or level it with shims. It’s OK if right side is higher.
•
Lime particles block water holes. Use CatGenie Machine Maintenance Powder or Cartridge
for lime removal. One or other included in your package (also at www.catGenie.com). When fixed, Press START for 4 seconds and Release.
IF NOTHING WORKS, Call 1-888-SELF-WASH ( 1-888-735-3927 ). Report Error #2 and symptoms. Have your Serial #.
A. WATER SENSOR IS DIRTY or missing. Remove Processing Unit. Pull Water Sensor up
from the top of the Hopper. Use a soft cloth to wipe Sensor and Tip. The Tip must be lime free
and shine. Carefully replace the Water Sensor securely. If Sensor is missing, find, clean, replace.
If lost, get another from Spare Parts bag under the CatGenie Base. Put in place. Gently replace
the Processing Unit securely in its slot.
B. WATER IS IN THE HOPPER. Do NOT unplug electric cord or remove Processing Unit.
Press Start/Pause Button to silence the Beep. Follow Clog Clearing Directions on page 17.
IF NOTHING WORKS, Call 1-888-735-3927. Report Error 1. Have your Serial #.
If you have a 1, 2, 3, or 4 Error, a Beep sounds the Error number.
The Error LED lights and the number LED lights which Error.
Both lit LEDs alternate blinks.
Example: 2 beeps, #2 LED & Error LED
lit, means you have an Error 2.
You could also
have a problem that
is not indicated by an
error LED or BEEP.
12
www.catGenie.com 1-888-735-3927
Raise a loop of the
DrainHose up one
foot from
Genie Base
Back of Processing Unit
Do NOT bend or
squeeze the
Hose
Dirty Tip
is Dull
Clean Tip
is Shiny
Mesh Filter

13
www.catGenie.com 1-888-735-3927
SOMETHING IS BLOCKING THE REAR VENTS OR FRONT BLOWER. CAUTION. Fire Hazard. Remove anything that blocks air
intake vents on back of Processing Unit. Move the CatGenie 2 inches away from wall. Remove obstructions in the Bowl that block dryer’s
hot airflow. Vacuum rear vents. Let Unit cool for 20 minutes. Press Start Button for 4 seconds. Drying should resume.
CAUTION: Stay with your CatGenie to make sure it’s is OK. If an Error alerts again, you smell burning, see sparks, or anything
abnormal, unplug immediately and contact Customer Service. Call 1-888-SELF-WASH ( 1-888-735-3927 ) Report Error #4. Have Serial #.
ERROR 4. Hear Beeps. Error LED & LED 4 lit. Dryer Overheats or Stops and Starts.
ERROR 3. Hear Beeps. Error LED & LED 3 lit. Cycle Complete. CatGenie is not draining.
CAUTION: Before fixing, feel whether the Washable Granules are WET, DAMP or DRY.
Follow A, if Granules are DRY
•
Follow B, if Granules are WET or DAMP
A:GRANULES ARE DRY but not washed.
CAUSE:
Cycle ran without water because the Water Sensor is crusted with lime.
It reads the lime deposit as if it was water.
Simple Solution: Remove Processing Unit. Pull the Sensor ends up from the top of the Brim. Use a soft cloth
soaked in lemon juice or your finger tips to remove the lime. The TIP must shine. Carefully replace the
Water Sensor securely into its slot. Then replace the Processing Unit. Press the Start Button to run a special,
regular Cycle where the GenieHand goes into a SUPER SHAKE mode to prevent a Granule clog.
B:GRANULES ARE WET or DAMP. Water has not drained from CatGenie.
CAUSE: Could be plumbing setup OR something stopped the draining.
•
For complete draining, the Genie DrainHose or Hook must NOT be pinched, squeezed, or tightly bent.
Make sure the Base of the CatGenie is NOT sitting on the DrainHose. Hose should pass through one of
the notches in back of the Genie Base.
Part or most DrainHose should be coiled loosely under the Base. No sharp bends!
Add lifts or “feet” to the toilet seat bottom so the seat does NOT squash the Hook. (See Photo).
See page 10 for fitting a Washing Machine Hose and GenieHose into the laundry or utility room drain pipe.
•
Make sure that the Genie DrainHose is not too high. Best if the GenieHose drains into a pipe that is
no more than 4 feet above the floor. If the drain is higher and you have draining problems, raise the CatGenie.
NEXT STEP: clear the unit of the clog that resulted from a setup
situation or from some other source. For example...
•
A toy, some other foreign object, or cat hair on the Impeller Shaft could stop draining
•
Granules under the Hopper have misaligned Hopper and DrainHose connection
•
Granules, dirt, or a small object could be blocking the Hopper Drain Holes
•
Hopper’s Red Washer is defective, squeezed, missing, or misaligned
SOLUTION: FOLLOW STEPS ON PAGE 17
SUPER TERRIFIC TIP: Clogging is often caused by not running the CatGenie
often enough. Try Cat Activation Mode. CatGenie runs better and extends SaniSolution.
See page 7 for programming.
SUPER TIP:
To keep your CatGenie running smoothly and to prevent
clogs and draining problems, use the CatGenie Machine Maintenance Products
4 to 6 times a year. You received a sample in your CatGenie package. Treatments
come in a Maintenance Solution Cartridge or a Powder in a Pouch.
TIP: Call 1-888-SELF-WASH ( 1-888-735-3927 ) Report Error #3 and Dry or Wet
Granules. CatGenie tech experts can guide you through the correction process. Have your Serial #.
Best if
DrainHose
goes into a
drain that’s
less than
4 feet
above
floor
This is WRONG.
Sharp bends
put stress on
the Hose.
Toilet seat “feet” prevent
a squashed Hook

7. GRANULES are WET or DAMP. Cycle is complete. NO ERROR WARNING.
First eliminate clog possibility. See page 17 and follow directions until clog is clear. Then follow all of Page 19 to #6.
Call 1-888-SELF-WASH (1-888-735-3927 ).Test if the drier is running hot, warm, or cold air. CALL if not hot. Have Serial #.
Genie Arm moves up & down freely with Processing Unit in place. This is not correct. Remove
Processing Unit. Clean off any Granules and debris on Brim or in slot where Unit sits. Hold the Hand
tightly and rotate the wheel (see photo) If the wheel turns easily and almost all around, call us. If the
wheel barely moves an inch, that is correct. Now wipe away Granules, even under the Processing
Unit and put it back into its slot. Check that Hose and Cord are fitted into their slots in back of Unit.
NOW, with the Processing Unit in place, test that the Hand still moves freely. If it does, call us.
Call 1-888-SELF-WASH (1-888-735-3927). Report Problem #8 and symptoms. Have Serial #.
8. GENIEHAND IS NOT SCOOPING at the START of a CYCLE.
PROBLEMS WITH ASSEMBLY AND NO ERROR INDICATED.
A: TURN OFF Laundry or Bathroom Water Supply Line. Unplug CatGenie. Wait 5 minutes and wipe up
the water. Search for the highest wet point for the source of the leak. Tighten all plastic knobs by hand.
Tighten all metal-to-metal connections with a wrench. Turn the water back on. If you see a leak, shut off the
water, wait 5 minutes, and retighten the connection that drips. Then turn the water back on. If you still have
a leak, shut off the water and wait 5 minutes. If this is in a laundry room leak, it could be B.
B: T-adapter’s BLACK WASHER is missing. 1. Disconnect the 3/4” T-adapter from the Water Supply
Valve. Keep the hoses connected. 2. If Black Washer is missing, purchase a washer at a hardware store.
If nothing works, Call 1-888-SELF-WASH (1-888-735-3927). Report Problem #5. Have your Serial #.
WATER OR DRAINAGE PROBLEMS. NO ERROR INDICATED.
5. CLEAN WATER is around the Base of the CatGenie. Granules are DRY.
6. WASTE WATER is around the Base of the CatGenie. Granules are DRY.
A. IN LAUNDRY, Genie DrainHose is not placed correctly in drain. See page 10 for placement.
IN BATHROOM, Genie DrainHook is not on toilet rim. Securely hook it over the rim so it stays put.
B. GENIE DRAINHOSE is bent too tight underneath the CatGenie Base. Lift a CatGenie side
to see if water is puddled underneath the Base. Loosen the loop and recoil the Hose. See photo.
Go to page 10 for correct Hose coil. Place paper towels under the Base to see if wastewater continues
to seep. Remember, it is normal to have some clean water mixed with SaniSolution inside the Base
and Hopper. Check if any water leaked underneath before you run another cycle.
If you see wastewater, Call 1-888-SELF-WASH (1-888-735-3927). Report Problem #6 and symptoms. Have your Serial #.
9. CATGENIE BOWL WON’T ROTATE or only goes in one direction
A. Bowl and/or Processing Unit not seated correctly. Lift Processing Unit out of its slot. See
the teeth on the edge of the Bowl exposed through the hole (photo). Use your finger to move Bowl
about 1/8 inch so that Bowl Gear can mesh with the Unit’s Gear. Clean out any debris or Granules
on Brim and in holes. Carefully slide the Processing Unit back into its slot.
B: If you added Spacer Discs, you may have added too many. See page 11 for directions to fix.
If rotation problems persist, follow all of Page 19 to #2. And Call 1-888-SELF-WASH
( 1-888-735-3927 ) for Service Rep help. Report Problem #9 and symptoms. Have your Serial #.
14
www.catGenie.com 1-888-735-3927

A. NO ELECTRIC POWER or a circuit breaker has tripped. Make sure the GenieCord is
plugged all the way in. Check if home’s electric power is on. Plug the CatGenie into a different
outlet. Test the CatGenie outlet with another appliance. When the Power is back on, the
CatGenie will Beep and then Start.
B. PROCESSING UNIT IS NOT CORRECTLY ALIGNED or seated in its slot on the Brim.
Remove Processing Unit. Clean off Granules or debris on Brim or in Unit’s slot. Then put the
Unit securely back into its slot. Check that Hose and Cord are in slots in back of the Unit.
If nothing works, Call 1-888-SELF-WASH (1-888-735-3927). Report Problem #11.
11. YOU PRESS START BUTTON and the CYCLE WON’T START.
A. CORD UNPLUGGED. Plug in the Genie Electric Cord. However a power interruption shifts the Auto Set times to later than programmed.
B. POWER FAILURE or power interruption caused CatGenie to reset. See page 7, SHORT CUTS for reset directions.
C. DAILY CYCLES NOT correctly programmed. Check that LEDs are lit to the number of Cycles that you want. See Page 7 to re-program.
D. Genie Eyes sense a presence in the Bowl and then delay the Cycle Start. Keep the area under
the GenieEyes clear of objects after you program the Auto Setup or it will postpone the cycle.
E. IN CAT ACTIVATION, Start Cycle waits 10 minutes after a cat uses the facilities. It waits another
10 minutes for each cat. If it’s set correctly, the Cat LED would be steady on. If not, go to page 7 to
re-program Cat Activation. After it’s set, wave your hand under the Eyes. The LEDs should blink rapidly.
Now keep the area clear for the next 10 minutes. The CatGenie should then start.
If you still have an Auto Start issue, Call 1-888-SELF-WASH (1-888-735-3927). Report Problem #12 and symptoms. Have your Serial #.
12. AUTO START NOT RUNNING at programmed times.
A: PAUSE MODE is automatically cancelled after 10 minutes. Then the CatGenie cleaning cycle resumes. This is a normal function.
The Pause feature turns the CatGenie back on so you don’t have to remember to do it.
B: TERMINATION MODE. You may have accidentally stayed pressed on the Pause button for too many seconds. More than 4 seconds on
the Pause Button and the CatGenie goes into Termination Mode. To resume a Cycle press Start/Pause Button.
14. AFTER PRESSING PAUSE TO STOP A CYCLE... A: the CatGenie RESTARTED by itself
OR B: the CatGenie did NOT START after the 10 minute Pause mode.
13. CYCLE INTERRUPTED, water in Bowl, wet or damp Granules, GenieHand is down.
A. NO ELECTRIC POWER. Power was interrupted; GFCI outlet or a circuit breaker was tripped. Make sure power
is restored. Plug in CatGenie cord. If Cycle does not resume, check circuit breaker operation. If Cycle still does NOT
continue, test outlet with another appliance. Test GenieCord in another outlet. Cycle should resume. If not, it’s B:
B. CATGENIE HAS A CLOG. See Clog Clearing Directions on page 17. Follow each step until clog is gone.
If nothing works, Call 1-888-SELF-WASH (1-888-735-3927). Report Problem #13 and symptoms. Have your Serial #.
POWER PROBLEMS: NO ERROR INDICATED
10. YOU PRESS START BUTTON and CatGenie BEEPS/BLINKS and/or WON’T START.
A. You may have pressed the START/PAUSE BUTTON too fast or too lightly. Firmly Press the Button again and release.
CatGenie answers with a Beep and should start a Cycle. If nothing happens, you may have a power problem. See #11 below.
B. You pressed Start, the Child Lock LED Blinks and Unit Beeps. Unit is in Child Lock Mode. To De-activate, Press the Start/Pause
and Auto Setup Buttons at the same time. HOLD until Beeps stop and LED goes out. Then release. Press Start Button to begin the Cycle.
C: You pressed Start. Cartridge LED lights; Unit Beeps. Cartridge missing. Replace. Make sure Cartridge is not empty.
D. You pressed Start. Error LED and Error Number LED alternate Blinks. Unit Beeps. Go to pages 12 or 13 to fix the Error indicated.
If nothing works, Call 1-888-SELF-WASH (1-888-735-3927). Report Problem #10 and symptoms. Have your Serial #.
15
www.catGenie.com 1-888-735-3927

www.catGenie.com 1-888-735-3927
16
CATGENIE MAINTENANCE
To keep your CatGenie running smoothly and to prevent problems like those seen
on pages 12 through 15, and on 17 and 18, take these simple precautions.
B. CLEAN WATER SENSOR or do A and you’ll never have to do B
Clean Tip
is Shiny
Dirty Tip
is Dull
If your cats have long or fuzzy fur, and/or your cats eat plastic, thread, string, or rug fabric,
it’s important that you check the inside of the Hopper on occasion. These things can cause clogs.
Sometimes cats (and kids) drop objects into the Bowl, which can get scooped into the Hopper.
Toys, stuffed animals, coins, stones, all kinds of things have been found in Hoppers.
Remove the Hopper Cover. Look inside Hopper. If you see fur or something that doesn’t belong, remove the
Processing Unit. Move the GenieHand down. Clear out the Hopper and clean the Water Sensor. See B, above.
Push Hand back up. Wipe off the Brim and bottom of the Processing Unit. Then put the Unit carefully back in its
place. It should Beep & Blink. If it doesn’t, check if the power cord is plugged in. Make sure that the Processing
Unit is securely and completely placed in its slot.
Check the Genie WaterHose and DrainHose. Make sure they are not crimped, crushed, or
coiled too tightly. Correct to prevent clogs.
Finally, we recommend that you run a Cycle to make sure that the assembly is correct.
A. PUSH BUTTON MAINTENANCE
How easy is this? Pop in the Machine Maintenance Cartridge.
Press the Start button and get a super clean, lime & grime free
CatGenie in places that you can’t readily reach. Result, extra clean,
odor free, germ free deep inside your cat’s bathroom. Ahhh, peace of
mind with a touch of a button. And a touch you do only four times a year.
Also available in Powder form in a Pouch. You have received a sample of one
or the other in your CatGenie package. Follow directions on the Cartridge or Pouch.
NOTE: By using the Maintenance Cleaners faithfully, you can skip Step B.
TIP:
RUN ON
CAT ACTIVATION
Tests prove that CatGenie
performs 1O times
better on it than other
settings and requires
less maintenance.
See Page 7 for
setting.
Gently Pull Out
Sensor
The Water Sensor TIP must be kept free of lime and mineral build up.
If you have hard water, it is important to clean it periodically. (Once every 3
months.) You can use the Maintenance Solutions (available at catGenie.com)
or do the following simple procedure. Keep power plugged and hoses in place.
Remove the Hopper Cover and pull the Processing Unit up and out of its slot.
Rest the Unit on a towel on the floor and lean it against the wall.
Grasp the Water Sensor Ends and gently pull up and out of the Base.
Have a towel soaked in lemon juice and/or use your finger to remove any lime
deposits and to make the TIP sparkle. Carefully slip the Sensor back into its slot.
Lower the GenieHand Check inside the Hopper. Remove fur and foreign
objects Before replacing the Unit, wipe away any Granules or debris off the Brim.
Raise the GenieHand to upright position. Place the Unit back into its slot.
It Beeps & Blinks. Your done. If it doesn’t, check if plugged in. Make sure the
P-Unit is securely placed. Check that the hose and cord are in their groves.
C. CHECK HOPPER to see what your cat dragged in.
Keep Hopper
clear of cat hair, toys,
and foreign objects
like coins.

17
www.catGenie.com 1-888-735-3927
2 STEPS to CLEAR a CLOG
Start with STEP 1. If not successful, go to STEP 2, page 18.
Or please call our service reps in Pennsylvania
who will happily guide you to success.
Need
Professional
Help? Call us at
888-735-3927
Have your serial #
ET 9a-11p WD
10 a-7p WE
STEP 1
A. Remove Hopper Cover. Pull
the Processing Unit up and out of its slot.
Rest it upright on a towel against the wall. Now uncoil the DrainHose
from under the Base. You could have water in it so be careful.
Lift one side of the Base up no more than 2”. Run the Hose out the
front of Base as shown in photo.
B: In the bath, take the DrainHook off the Hose. In the laundry,
take the DrainHose out of the drainpipe. Hold the Hose tip. Shake
and bang the Hose on the floor towards the Base. This could loosen
the clog and force it back into the Hopper for more processing.
C: Cleaning Hook & Hose. Using your hand, clamp the end of the
Hose tightly onto the faucet as shown. Turn on water for 5 seconds.
Water pressure should force the clog back into the Hopper. Also
massage the Hook and run water through it. Reconnect Hook to
Hose, return to toilet rim, and keep seat up. Put Hose into drainpipe.
Don’t squeeze with washer hose. Do nothing to restrict water flow.
D: The Black Knob on the Brim is the top of the Impeller, which
grinds solids. Rotate its center knob clockwise 5 times. It should turn
easily. Right next to the Knob find the Water Sensor. Pull it out and
wipe its Tip clean. (See page 16.) Check the Hopper. Lower the
GenieHand. In the Hopper, remove any foreign objects or cat hair
wrapped around the Impeller shaft. Replace the Processing Unit
into its slot. It should Beep and Blink. If not, check if it’s plugged in
or if the Processing Unit is correctly seated in its slot.
E: Follow CLOG-CLEAR MODE & DRAIN TEST below.
H. BACK to NORMAL:
•
Reassemble your CatGenie. Coil
the Hose under Base, see photo.
•
Press the Auto Button 2 times so
now you have #4 LED and #3 LED
lit. Make sure you have a working
Cartridge placed correctly in the slot.
•
Press Start. 3 long Beeps and all
numbered LEDs light. This means
the CatGenie has initiated a special
correction cycle.
•
Granules are wet, so the Genie-
Hand won’t initially scoop. Then the
CatGenie washes, drains, and dries.
And finishes back to normal.
Hose under the Base
rap
bang
shake
knock
the Hose
against
the floor
Remove Processing Unit
F. CLOG-CLEAR MODE:
•
Lift the Processing Unit out of its slot,
count to 3 and carefully put Unit back.
•
During 1st series of Beeps & Blinks,
immediately press and HOLD the
Start & Auto Buttons at the same time.
Beeps & Blinks stop; but keep pressing.
•
Then when a 2nd series of Beeps &
Blinks activate, release both Buttons.
•
The 3rd series of Beeps & Blinks
means you’re in Clog-Clear Mode.
•
The #1 LED stays lit. You’re now
ready to proceed to the Drain Test.
G. DRAIN TEST:
•
First Press & Release Auto Button.
The #2 LED lights & 2 Beeps sound.
•
Then Press Auto Button 3more times
until the #1 and #4 LEDs are on. Stop.
•
Press & Release Start to operate drain
pump. CAT LED lights; 1 Beep sounds.
Watch for water draining out from the
end of Hose in toilet or drainpipe.
•
If water DOES drain from the Hose
for at least 1 minute, the clog is cleared.
Congratulations. Press the Start Button.
Drain shuts and water stops.
Proceed to Back to Normal at right.
•
If water does NOT drain, press
Start to shut it off.
Repeat
STEP 1.
from A to G.
Repeat 3 times; stop if clog clears.
If still not draining after 3 times
go to
Page 18, Step 2.
Water Sensor Clear the Hopper

BEFORE TAKING STEP 2, take your CatGenie apart.
TIP: This part is messy. Wear gloves.
Pull out Hopper. If dirty or filled with water open the Hopper above the
Bowl, then put it in or on a bucket or on newspapers. Clean out any hair
or debris around the Impeller. Be careful not to lose the HairCutting Ring
and the Red Washer. In a sink or tub, thoroughly wash the Hopper.
STEP 2. CLEAN THE HOPPER INSIDE & OUT...
CLEAN INSIDE THE BASE. A dirty job that maintenance prevents.
1) Remove Hopper Cover and
Processing Unit. Rest Unit on
a towel. Lean it against a wall.
2) Unclip the GenieHand.
3) Push its Clip though the Brim.
4) Remove Brim by pushing on
Knob for leverage. Pull up back
5) to release Brim from Base.
www.catGenie.com 1-888-735-3927
18
Remove all Granules from every nook and cranny inside and out
and around the Hopper. Replace HairCutting ring, teeth down, on ridge
inside the Hopper. Close the cleaned Hopper. Wash the Red Washer.
Dab with liquid soap or baby oil. Proceed to Base cleaning.
Remove Bowl. If the Bowl is filled with wet Granules, place it in a trash bag to avoid leaks. Close bag to prevent cats from using the Granules.
Remove GenieScrubber from Base. Dump the dirty water from the Base. Be careful. Keep the DrainHose in the drainpipe or toilet.
If you have to move the Base in order to dump the water, remove the DrainHose and hold it above (higher than) the Base to avoid leaks.
Once the Base is empty, REPEAT STEP 1 parts B and C on page 17.
CLEAN THE BASE. Clean/wash out all Granules from all parts of the Base, especially the Slot where the Hopper sits and the hole into the
DrainHose. Once all is cleaned and cleared, coil the Hose under the Base as shown in photo to avoid clogs.
ASSEMBLE THE CATGENIE: Put the Drain Hose in toilet or drainpipe. Add the Hopper now, so you can see that the Red Washer is in place.
Put GenieScrubber, feet up, into the Base. Replace the Bowl, make sure it is centered and rotates. Now add the Brim and the GenieHand
in its up position. Before replacing, check the bottom of the Processing Unit for orange niplet. RETURN TO PAGE 17. FOLLOW F and H.
fresh water Intake
wastewater drain
Keep
Bowl of wet
Granules in a trash bag
If you must move the Base
to empty it,
hold the Hose
up higher than
the Base.
Remove
Granules from
every nook &
cranny
*
*
*
If you can’t clean the Base at this time, OR it’s not possible for you to dump the dirty water, go to page 17. Repeat STEP 1 parts B and C.
Then return here, page 18, to
ASSEMBLE THE CATGENIE, see just above and follow those steps. Because the dirty water was not
emptied, it will be difficult to replace the Hopper. Push it down, slowly. Once assembled, return to page 17 and follow F and H.
IMPORTANT: This short cut is not the solution. Not following the proscribed cleaning steps will cause a second clog. It is...
MANDATORY that you must Repeat Step 2 , page 18, very soon, before running more than 2 regular Cycles. Your chances of having
another clog on top of the partially cleared one is almost guaranteed.
Under the
Base, coil
DrainHose
loosely
around the
center knob
Scrubber goes
feet up and off
center
REMEMBER, you can always call us for help. 1-888-735-3927. Have your Serial #

CatGenie Tech has 6 Component Modes, which enable you to check if your CatGenie functions work or not. It also has 2 Test Modes.
By pushing the 2 Buttons on the Control Panel as directed, you can easily find what ails your CatGenie. Read before proceeding.
If you have any questions or are confused, please call us at 1-888-735-3927. Have your Serial # handy. (Panel below indicates a #5 Tech Mode)
A. FIRST ACCESS TECH MODE
•
•
Lift the Processing Unit out of its slot, count to 3 and carefully put it back.
•
•
When you hear a series Beeps and 3 LEDs Blink, immediately press and HOLD Start
& Auto Buttons at the same time. Keep holding. Beeps & Blinks stop; but keep holding.
•
•
Then when a 2nd series of Beeps & Blinks activate, release both Buttons.
•
•
A 3rd series of Beeps & Blinks activates telling you that you are in Tech Mode
•
•
The #1 LED stays lit, telling you to proceed to the next step.
B. NOW ACCESS the individual COMPONENT MODE that relates to your specific problem. In Column One,
find Component (1 to 6) that applies and follow the directions across. NOTE: *indicates CAUTIONS. P&R indicates Press & Release.
CATGENIE TECH Only go here if directed from the Trouble Shooting pages
or when on the phone with a Customer Service Representative.
www.catGenie.com 1-888-735-3927
19
C. EXITING CATGENIE TECH
CatGenie Tech (Tech Mode) is active for 30 minutes. After 30 minutes, CatGenie reverts to normal operations mode. If you want to get out of
Tech Mode sooner,
lift the Processing Unit out of its slot, count to 3 and carefully put it back.
When you Activate 7, you get out of Tech Mode.
CAUTIONS:
*Pay special attention when operating the Water Valve (fresh water in). If performing correctly, the CatGenie stops filling when water reaches
the Water Sensor. If not turned off, (see column 4 press START for OFF) filling resumes as soon as water level drops below the Water Sensor.
** You must NOT leave the area while testing the Dryer. It is critical to pay attention while testing. Shut down if you must leave.
*** Do not over work Components1 through 6, as they could be damaged. These are only for diagnostic purposes.
CAUTION: Operate column 4, actions 1 through 6, at a maximum of no more than 30 seconds. After testing, make sure everything is OFF.
NOTE: Use the #7 Special Cycle when Granules are wet or damp as a result of poor or no draining from a clog.
TIP: Two LEDs help you navigate column 4 Actions: Cartridge LED indicates UP, ON, or RIGHT. Child Lock LED indicates DOWN, OFF, or LEFT
SHADED AREAS
SHADED AREAS are only to be used with a Service Rep at 1-888-735-3927. Please call if you are unsure about any process.
Table of contents
Other PetNovations Pet Care Product manuals