Before You Begin
1. Before You Begin
What Is Included
Enquirment 1pcs
PowerCon Cable 1pcs
User Manual 1pcs
Safety Notes
Please read the following Safety Notes carefully before starting to work with the product.
These notes provide important safety information about the installation, usage, and
maintenance.
Always connect this product to a grounded circuit.
Make sure the power cord is not crimped or damaged.
Always connect this product to a power source with the proper voltage
as listed on the product sticker.
Do not operate the product if there is damage to the housing.
This product is for indoor use only! It is rated IP20. Do not expose the
product to rain or moisture.
Always disconnect this product from power before cleaning it or changing
the fuse.
Never disconnect the product from the power source by pulling or tugging
on the cord.
If mounting the product overhead, always secure it using a safety cable.
Make sure there are no flammable materials close to the product when it
is operating.
This product is not intended for permanent installation.
Never connect the product to a dimmer or a rheostat.
Always install the product in a location with adequate ventilation.
Do not operate the product in an ambient temperature higher
than 104 °F (40 °C).
This product contains no user-serviceable parts. Any reference to servicing
in this User Manual will only apply to properly trained certified technicians.
Do not open the housing or attempt any repairs.
Any damages caused by manual modifications are not subject to warranty.
will not accept liability for damage caused by unauthorized modifications
or not observing the safety warnings and instructions in the manual.
All applicable local codes and regulations apply for proper installation of
this product.
In the event of a serious operating problem, stop using the
product immediately.
· If the product requires repair contact us. For more information see Returns
and Contact Us.
Keep this User Manual for future reference.

Introduction
2. Introduction
Product Description
AD8 is a reliable and versatile rack-mountable Art-Net -to-DMX adapter with an integrated
optical DMX splitter ,DMX booster and Art-Net hub capability. It has two 3-pin DMX In ports
and eight 3-pin DMX Out ports, all optically isolated. It takes up to 8 Art-Net universes
simultaneously. The eight 3-pin DMX Out ports can be assigned to either of the DMX In ports
or to one of the Art-Net PowerCon ports. PowerCon ports are through ports that allow daisy
chaining of AD8 units.
AD8 provides a reliable, highly customizable network infrastructure for complex control
systems.
Additional Products
The AD8 is an adapter ,booster and hub combined that works as part of a control system.
3. Setup And Installation
AC Power
AD8 has an internal auto- ranging power supply that works with an input voltage range of
110–240 VAC, 50/60 Hz. To determine the power requirements for the AD8 refer to the label
affixed to the product or Technical Specifications.
Always connect this product to a properly grounded and protected
circuit.
Never connect this product to a rheostat (variable resistor) or dimmer
circuit, even if the rheostat or dimmer channel serves only as a 0 to
100% switch.
Fuse Replacement
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the fuse holder out of the housing.
4. Remove the blown fuse from the holder.
5. Replace with a fuse of the exact same type and rating.
6. Insert the fuse holder back in place and reconnect power.
Disconnect the product from power before replacing the fuse
Always replace a blown fuse with another of the same type and rating.
A spare fuse is not included; however, the safety cap has room for a spare.

Mounting
The AD8 fits nicely in a standard 19” rack, or sits on a flat surface. The Net-X should be
placed where the menu and the ports are accessible, and where there is adequate ventilation.
Signal Connection
The AD8 receives signal though 2 DMX In ports and PowerCon ports. It sends signal out
through 8 DMX Out ports and Artnet output
Installation Guidelines
The AD8 is used as part of a control system for operating various lighting and multi-media
products. The physical and digital construction of the control network is determined by the
location and signal needs of the products.
When designing a control system that uses the AD8 , consider the following:
Placing the AD8 so the menu and ports can be accessed
Running the cables so there is no tension or pull on the cables or plugs
·Planning a large control system carefully before configuring the components, so IP
address, DMX address, and other identifiers are not duplicated
4. Features
Distributes Art-Net data to 8 DMX512 universes (4096 channels)
Parallel DMX input possible (1024 channels)
8 optically isolated XLR plugs (3-pin) for DMX output
2 XLR (3-pin) for DMX input
Variable data routing capabilities for all DMX outputs
1 x powercon in/through port
Serial connection possible
User-friendly configuration directly at the front panel via 4 operating buttons and alphanumeric LCD
screen (2 x 16 characters)
LED indication for functions
DMX Splitter / DMX booster operation possible
Rack installation 1 U
5. Technical Specifications
6 .Configuration And Operation
The AD-8 is configured through the control panel, using the control panel buttons. Once the AD-8 is
properly configured it operates without user intervention.
The AD-8 can be used as a DMX splitter only, in which case the DMX In ports must be assigned to the DMX
Out ports, but the Net, Subnet, and IP address settings do not need configuration.
The AD-8 can be used as an Art-Net hub, in which case the AD-8 universes must be assigned to the DMX
Out ports, and the Net, Subnet, and IP address settings must be configured.
Power supply:
110-240 V AC, 50/60 Hz
Power consumption:
15 W
DMX512 inputs:
2 x 3-pin XLR male
DMX512 outputs:
8 x 3-pin XLR female
Ethernet:
2 x RJ45 100 Mbps
Protocol:
Art-Net 4
Dimensions (LxWxH):
483 x 169 x 44.4 mm
Weight:
2.9 kg

The AD-8 can be used as both a DMX splitter and an AD-8 hub simultaneously, in which case both the DMX
assignments and the AD8 settings must be configured. For more information, see Configuration Examples.
DMX In ports and universes can be assigned to multiple DMX Out ports.
Control Panel
The control panel is the mechanism for configuring the AK-AD8 settings. It has a small LCD screen and four
buttons, which are described below.
Button
Function
<MENU>
Scrolls through the first level of options, or exits from the current menu or
function
<UP>
Navigates upward through the menu list or increases the numeric value
when in a function
<DOWN>
Navigates downward through the menu list or decreases the numeric value
when in a function
<ENTER>
Enables the currently displayed menu or sets the currently selected value in
to the current function

Menu Map
The menu map shows the organization of the configuration settings. Use it for reference
when configuring the AD8

7. Technical Information
Maintenance
To maintain optimum performance and minimize wear, the user should clean this product
regularly. Usage and environment are contributing factors in determining the cleaning
frequency.
As a rule, clean this product at least twice a month. Dust build-up reduces light output
performance and can cause overheating. This can lead to reduced light source life and
increased mechanical wear.
To clean the Net-X, do the following:
1. Unplug the panel from power.
2. Wait until the unit is at room temperature.
3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the
external vents.
4. Clean all external surfaces with a mild solution of non-ammonia cleaner or isopropyl
alcohol.
5. Apply the solution directly to a soft, lint-free cotton cloth or a lens cleaning tissue.
6. Make sure all connections are thoroughly dry before reconnecting power and signal
cables.
Keep the environment around the Net-X free of dust, dirt, water, and extreme temperatures.
Insert and remove DMX and Powercon cables slowly and gently.
Put the Net-X on the top of any stacks of equipment, or rack mount it.
Turn the Net-X off when it is not in use.
Always dry the external surfaces carefully after cleaning them.
This manual suits for next models
1
Table of contents