Thank you for purchasing DG-100. Please read this Owner’s Manual thoroughly for proper operation before starting to use your
equipment so that you may use this for a long period of time.
Owner’s Manual
Connect the MC step-up
transformer or the MC
cartridge to be degaussed.
This button is for turning the
power on/off. When the power
is on, the button surroundings
become blue.
This button is for starting the
daguassing. While it is
degaussing for 20sec., the
button surroundings become
blue.
A connection
with an RCA
cable
A connection
with an RCA
cable
Attach the MC cartridge to the
arm and connect the RCA plug
of the player to LINEOUT of
DG-100.
MC step-up
transformer
Connect the input of the MC
step-up transformer to
LINEOUT of DG-100.
Please disconnect the phono and the
preamplifier from the MC step-up
transformer before degaussing.
The speaker can be damaged from
the loud noise.
A connection with the attached
plug (has a clip). Connected to
one of the LINEOUT terminals
for DG-100.
If the output cord from the player is
XLR, connect the accessory plug (has
a clip) directly to the cartridge
terminal.
Connect the red lead cord to the
red(R+) / white(L+) of the cartridge and
the green lead cord to the green(R-) /
blue(L-) of the cartridge.
・ Air-core MC cartridges and optical cartriges do not have magnetic material coiled and therefore there
is no effect even if degaussed.
・ When degaussing MM and MI type cartridges, the needle tip must always be removed. Do not use it
if the needle cannot be removed or else the magnet will be degaussed.
・ When degaussing the MC step-up transformer, please disconnect the phono and preamplifier from the
transformer and degauss the transformer by itself. The speaker can be damaged from the loud noise.
・ If the RCA plug does not easily fit, do not insert it in by force. The RCA jack of the unit may break.
Red Cord
Green Cord
1. Connect the unit to be degaussed to
LINEOUT
2. Press the POWER button.
3. Press the START button.
Functions and Operations Connection1 (Connecting to the MC step-up transformer)
Connection2 (Connecting to the MC cartridge) Connection3(Connecting to the MC cartridge)
Accessories: 9V battery and a plug with a clip (it is stored in the battery case)
Specifications and appearance design are subject to change without notice due to improvements.
Product Specifications
Output Oscillation Frequency
Output Voltage
Output Waveform
Output Impedance
Dimensions
Weight
Output Terminals(RCA×2)
440Hz  5%
0.7Vrms or more
Exponetial Decay Waveform for 20sec.
280
69(W)×28(H)×121(D) mm
172g
Gold Plated Terminals
When To Exchange the Battery
・ If the illumination around the POWER button has darkened, it is a sign that the battery amount is low.
Please exchange to a new battery as soon as possible.
・ If the empty battery is left remained, liquid may leak out and will lead to damaging the unit.
MC step-up transformers and MC catridges containing an iron core slowly degausses and sounds detoriorate.
If degaussing is done once every two to three months, you can always enjoy fresh sounds.
+
_
When To Degauss
As for the unclear matters with regards to the after service, please contact the dealer.
Kyodo Denshi Engineering Co., Ltd.
8-40-17 Shinyoshidahigashi, Kohoku-ku, Yokohama-shi 223-0058
TEL 81-45-710-0975
FAX 81-45-710-0976
E-mail [email protected]
URL https://www.phasemation.com
is the original audio brand of Kyodo Denshi Engineering Co., Ltd.
Notice
・ Degaussing the MC step-up transformer of EA-350/550:
Degauss at Input2 (RCA terminals) of the rear when the power is off.
・ Degaussing the MC step-up transformer of EA-500:
Degauss at MC Input1 (RCA terminals) of the rear when the power is off.
・ Degaussing the MC step-up transformer of EA-1000:
When the power is on, degauss it when the INPUT is at MC2 (front side), the MC IMPEDANCE is at HIGH (front side),
and the MC INPUT2 (rear side) is connected to the RCA terminal. At this time, the preamplifier that is connected must be
turned off. The speaker can be damaged from the loud noise.
・Degaussing the CM-2000:
Set the INPUT of the front to “1”, connect to the INPUT1 and RCA terminals of the rear, and degauss.

Popular Industrial Electrical manuals by other brands

Leviton 16351-SG Installation

Leviton

Leviton 16351-SG Installation

PR electronics 9202 Series manual

PR electronics

PR electronics 9202 Series manual

GE PHI 530.1425.2500 Operating and maintenance instructions

GE

GE PHI 530.1425.2500 Operating and maintenance instructions

Eaton EZ installation instructions

Eaton

Eaton EZ installation instructions

OmniOn Power 150049763 quick start guide

OmniOn Power

OmniOn Power 150049763 quick start guide

Murata GRM1555C2A6R7DA01 Series Reference sheet

Murata

Murata GRM1555C2A6R7DA01 Series Reference sheet

Murata GRM32ER71C226MEA8 Series Reference sheet

Murata

Murata GRM32ER71C226MEA8 Series Reference sheet

Murata GRM1555C2A6R3CA01 Series Reference sheet

Murata

Murata GRM1555C2A6R3CA01 Series Reference sheet

Wieland gesis FLEX-FC EM Assembly instruction

Wieland

Wieland gesis FLEX-FC EM Assembly instruction

Murata GJM0335C1H2R4BB01 Series Reference sheet

Murata

Murata GJM0335C1H2R4BB01 Series Reference sheet

GE Spectra Series installation instructions

GE

GE Spectra Series installation instructions

Power Electronics SDRIVE DB Series Getting started manual

Power Electronics

Power Electronics SDRIVE DB Series Getting started manual

Eaton P1/I2 Series Instruction leaflet

Eaton

Eaton P1/I2 Series Instruction leaflet

Moeller U-NZM 10 installation instructions

Moeller

Moeller U-NZM 10 installation instructions

Murata GRM155R71H392KA01 Series Reference sheet

Murata

Murata GRM155R71H392KA01 Series Reference sheet

Siko MSAC501 Additional to the Original Installation Instructions

Siko

Siko MSAC501 Additional to the Original Installation Instructions

Murata GRM1885C2A200JA01 Series Reference sheet

Murata

Murata GRM1885C2A200JA01 Series Reference sheet

S&C IntelliRupter PulseCloser instruction sheet

S&C

S&C IntelliRupter PulseCloser instruction sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.