DG-100
DEGAUSSER
①
②
③
LINEOUT
POWER
START
Connection1 (Connecting to the MC step-up transformer)Connection1 (Connecting to the MC step-up transformer)
Caution
Connection2 (Connecting to the MC cartridge)Connection2 (Connecting to the MC cartridge) Connection3Connection3((Connecting to the MC cartridgeConnecting to the MC cartridge))
How to operate
Caution
D010-0920-00E
Thank you for purchasing DG-100. Please read this Owner’s Manual thoroughly for proper operation before starting to use your
equipment so that you may use this for a long period of time.
Owner’s Manual
Connect the MC step-up
transformer or the MC
cartridge to be degaussed.
This button is for turning the
power on/off. When the power
is on, the button surroundings
become blue.
This button is for starting the
daguassing. While it is
degaussing for 20sec., the
button surroundings become
blue.
A connection
with an RCA
cable
A connection
with an RCA
cable
Attach the MC cartridge to the
arm and connect the RCA plug
of the player to LINEOUT of
DG-100.
MC step-up
transformer
Connect the input of the MC
step-up transformer to
LINEOUT of DG-100.
Please disconnect the phono and the
preamplifier from the MC step-up
transformer before degaussing.
The speaker can be damaged from
the loud noise.
A connection with the attached
plug (has a clip). Connected to
one of the LINEOUT terminals
for DG-100.
If the output cord from the player is
XLR, connect the accessory plug (has
a clip) directly to the cartridge
terminal.
Connect the red lead cord to the
red(R+) / white(L+) of the cartridge and
the green lead cord to the green(R-) /
blue(L-) of the cartridge.
・ Air-core MC cartridges and optical cartriges do not have magnetic material coiled and therefore there
is no effect even if degaussed.
・ When degaussing MM and MI type cartridges, the needle tip must always be removed. Do not use it
if the needle cannot be removed or else the magnet will be degaussed.
・ When degaussing the MC step-up transformer, please disconnect the phono and preamplifier from the
transformer and degauss the transformer by itself. The speaker can be damaged from the loud noise.
・ If the RCA plug does not easily fit, do not insert it in by force. The RCA jack of the unit may break.
Red Cord
Green Cord
1. Connect the unit to be degaussed to
LINEOUT
2. Press the POWER button.
3. Press the START button.
Functions and Operations Connection1 (Connecting to the MC step-up transformer)
Connection2 (Connecting to the MC cartridge) Connection3(Connecting to the MC cartridge)
Accessories: 9V battery and a plug with a clip (it is stored in the battery case)
Specifications and appearance design are subject to change without notice due to improvements.
Product Specifications
Output Oscillation Frequency
Output Voltage
Output Waveform
Output Impedance
Dimensions
Weight
Output Terminals(RCA×2)
440Hz  5%
0.7Vrms or more
Exponetial Decay Waveform for 20sec.
280
69(W)×28(H)×121(D) mm
172g
Gold Plated Terminals
When To Exchange the Battery
・ If the illumination around the POWER button has darkened, it is a sign that the battery amount is low.
Please exchange to a new battery as soon as possible.
・ If the empty battery is left remained, liquid may leak out and will lead to damaging the unit.
MC step-up transformers and MC catridges containing an iron core slowly degausses and sounds detoriorate.
If degaussing is done once every two to three months, you can always enjoy fresh sounds.
+
_
When To Degauss
As for the unclear matters with regards to the after service, please contact the dealer.
Kyodo Denshi Engineering Co., Ltd.
8-40-17 Shinyoshidahigashi, Kohoku-ku, Yokohama-shi 223-0058
TEL 81-45-710-0975
FAX 81-45-710-0976
E-mail [email protected]
URL https://www.phasemation.com
is the original audio brand of Kyodo Denshi Engineering Co., Ltd.
Notice
・ Degaussing the MC step-up transformer of EA-350/550:
Degauss at Input2 (RCA terminals) of the rear when the power is off.
・ Degaussing the MC step-up transformer of EA-500:
Degauss at MC Input1 (RCA terminals) of the rear when the power is off.
・ Degaussing the MC step-up transformer of EA-1000:
When the power is on, degauss it when the INPUT is at MC2 (front side), the MC IMPEDANCE is at HIGH (front side),
and the MC INPUT2 (rear side) is connected to the RCA terminal. At this time, the preamplifier that is connected must be
turned off. The speaker can be damaged from the loud noise.
・Degaussing the CM-2000:
Set the INPUT of the front to “1”, connect to the INPUT1 and RCA terminals of the rear, and degauss.

Popular Industrial Electrical manuals by other brands

Murata GRM32EC80J476ME64 Series Reference sheet

Murata

Murata GRM32EC80J476ME64 Series Reference sheet

SDI VOXBOX quick start guide

SDI

SDI VOXBOX quick start guide

Softing FG-200 HSE/FF user manual

Softing

Softing FG-200 HSE/FF user manual

Murata GRM0335C1H3R2CA01 Series Reference sheet

Murata

Murata GRM0335C1H3R2CA01 Series Reference sheet

Murata GRM219R71C224KA01 Series Reference sheet

Murata

Murata GRM219R71C224KA01 Series Reference sheet

Murata GRM155R60J334KE01 Series Reference sheet

Murata

Murata GRM155R60J334KE01 Series Reference sheet

Murata GRM0225C1E3R6CA03 Series Reference sheet

Murata

Murata GRM0225C1E3R6CA03 Series Reference sheet

ABB ACS 800 Series Installation

ABB

ABB ACS 800 Series Installation

BGK AutoCure 5000 Assembly and operating manual

BGK

BGK AutoCure 5000 Assembly and operating manual

Akapp-Stemmann Pro-Ductor PR7 Mount Guide

Akapp-Stemmann

Akapp-Stemmann Pro-Ductor PR7 Mount Guide

Murata GRM0335C1E5R1BA01 Series Reference sheet

Murata

Murata GRM0335C1E5R1BA01 Series Reference sheet

Murata GRM0335C1H3R7CA01 Reference sheet

Murata

Murata GRM0335C1H3R7CA01 Reference sheet

Murata GRM1555C1H3R9WA01 Series Reference sheet

Murata

Murata GRM1555C1H3R9WA01 Series Reference sheet

RFS APD-D Series product manual

RFS

RFS APD-D Series product manual

Siemens SIRIUS S00 Original operating instructions

Siemens

Siemens SIRIUS S00 Original operating instructions

Murata GRM1885C2A5R1DA01 Series Reference sheet

Murata

Murata GRM1885C2A5R1DA01 Series Reference sheet

Murata GRM0225C1E8R1WA03 Series Reference sheet

Murata

Murata GRM0225C1E8R1WA03 Series Reference sheet

Murata GQM22M5C2H2R7BB01 Series Reference sheet

Murata

Murata GQM22M5C2H2R7BB01 Series Reference sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.