Philio PAN08-2A User manual

PAN08-1A/-2A/-3A Roller shutter controller
Fig 1. Assembling
The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter
connected to its terminals using radio waves, controllers and a push button directly
connected to this Roller Controller.
This in-wall Roller Shutter Controller is a transceiver which is a Z-Wave lusTM
enabled device and is fully compatible with any Z-WaveTM enabled network. Slim
design let the Controller can easily hide itself into the wall box and that will be good
for the house decoration.
The new smart relay calibration technology can reduce the inrush current caused by
the load and let the module work perfectly with many kind of Roller Shutter.
This in-wall Roller Shutter Controller is able to detect position of the Shutter by using
the patterned power measuring method, so it can be remote controlled not only fully
up or down , but also can be adjusted to ex. 30% or 50%. And when manual
controlled by push button, the controller also can memorize the position and send the
new shutter position to its controller (ex. I -Gateway).
Adding to Z-WaveTM Net ork
In the front casing, there is an include button with LED indicator below which is used
to carry out inclusion, exclusion, reset or association. When first power is applied, its
LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies
that it has not been assigned a node ID and start auto inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the AN08 does not have
Node ID and just connect the AN08 to main power.
1

Note: Auto inclusion timeout is 2 minute during which the node information of
explorer frame will be emitted once every several seconds. Unlike “inclusion” function
as shown in the table below, the execution of auto inclusion is free from pressing the
Include button on the AN08.
The table below lists an operation summary of basic Z-Wave functions. lease refer
to the instructions for your Z-WaveTM Certificated rimary Controller to access the
Setup function, and to include/exclude/associate devices
Function Description LED Indication
No node ID The Z-Wave Controller does not allocate
a node ID to the AN08.
LED 2-second on, 2-second
off
Inclusion 1. ut your Z-Wave controller into
inclusion mode by following the
instructions provided by the
controller manufacturer.
One press one flash LED
2. ressing Include button three times
within 2 seconds will enter inclusion
mode.
Exclusion 1. ut your Z-Wave controller into
exclusion mode by following the
instructions provided by the
controller manufacturer.
One press one flash LED
2. ressing Include button three times
within 2 seconds will enter exclusion
mode.
Node ID has been excluded. LED 0.5s On, 0.5s Off (En-
ter auto inclusion)
Reset 1. ressing Include button three times
within 2 seconds will enter inclusion
mode.
Use this procedure only in
the event that the primary
controller is lost or
otherwise inoperable.
2. Within 1 second, press Include
button again for 5 seconds.
3. IDs are excluded. LED 0.5s On, 0.5s Off (En-
ter auto inclusion)
Association 1. The AN11 is an always listening
Z-Wave device, so associations
be added or removed by a controller
at any time.
Or If your controller requires to have
the AN11 send a 'node information
frame' or NIF for associations,
pressing the On/Off button three
times within 2 seconds will cause
the AN11 to send its NIF.
LED One press one flash
2. There are 1 group (Group 1) for the
AN08
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
2

Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
To distinguish what mode the AN08 is in, view from the LED for identification.
State Type LED Indication
Motor
activate
No matter up or down, close or open, Led will flash every second
while Motor activate.
When S1 or S2 close to L, the LED will flash even when the motor
stop by itself, this is to let user know the S1 or S2 still close and not
been release yet.
No node ID Under normal operation, when the AN08 has not been allocated a
node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or Include button, it will stop flashing
temporarily.
Learning When AN08 is in learning mode, LED flashes on and off
alternately and repeatedly at 0.5 second intervals.
Overload When overload state occurs, the AN08 is disabled and LED
flashes on and off alternately at 0.2 second intervals. AN08 will
send alarm_type=8 alarm_Level=0xFF to Group1, Overload state
can be cleared by disconnect and reconnect the AN08 to the main
power
Choosing a Suitable Location
1. Do not locate the AN08 facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the AN08 is 0°C~40°C.
3. Do not locate the AN08 where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of AN08 will become a little bit hot of which
phenomenon is normal.
Installation and operation
1. ut the in wall AN08 into a wall box and connect the AC power wire L,N to
AN08 connector L, N.
2. Connect the wall switch to the AN08 as Fig1 .
3

3. It is important to carry out a shutter calibration process before you control the
shutter to move. ress inclusion button over 3 seconds and release before the
6th second, the roller shutter controller will start the shutter calibration process.
The process is composed of three continue stages. The shutter move to the TO
in first stage, and move to the BOTTOM in second stage, and move to the TO
again in third stage. Then AN08 will know the total range of U and DOWN.
4. During the shutter calibration process, any emergencies happen you can press
and release the include button to stop the process
5. If user found the direction is reverse, this may cause by the wrong connection of
NC and NO to the motor, please change NC and NO connection and execute
calibration process again.
6. For safe issue, please select the motor which can stop by itself when go to
bottom end or top end.
7. To manually switch up and down of the shutter, simply press the external switch
S1 or S2. The detail is described in 7-5.
8. AN08 built in meter function and can read the Watt, KWh, V(Voltage),
I(Current), F( ower Factor) of the load by using Z-Wave command class, user
can set a threshold current to get the warning caused by abnormal operation
9. AN08 have overload protection function, and can help to prevent short circuit
caused by load.
Programming
1. Basic Command Class
The AN08 will respond to BASIC and BINARY commands that are part of the
Z-Wave system.
1.1 BASIC_GET
When AN08 receive Basic Get Command, it will send Basic Report Command
to report the position of the shutter. When the report value is 0x00, that mean the
shutter is at the Bottom, if the report value is 0x63 or 0xFF that mean the shutter
is at the Top, any other value between 0x01~0x62 imply Shutter at the position
between top and bottom.
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
[Command Class Basic, Basic Report, Value = 0x00 (BOTTOM)]
[Command Class Basic, Basic Report, Value = 0x01~0x62 (Bet een BOT-
TOM and TOP)]
[Command Class Basic, Basic Report, Value = 0x63/0xFF (TOP)]
1-2 BASIC_SET
4

AN08 can accept Basic Set Command which value is either (0x00) Bottom or
Top (0x63/0xFF) or (0x01-0x62) the position between TO and Bottom. Other
value (0x64-0xFE) is not acceptable.
[Command Class Basic, Basic Set, Value = 0x63 or 0xFF] control the shut-
ter to the top (0xFF)
[Command Class Basic, Basic Set, Value = 0x00(0)] control the shutter to
the bottom(0x00)
[Command Class Basic, Basic Set, Value = 0x01-0x62] control the shutter
to the position bet een bottom and top
2 Binary S itch Command Class
2-1 BINARY_SWITCH_GET,
When AN08 receive Binary Switch Get Command, it will send Binary Switch Report
Command to report the position of the shutter. When the report value is 0x00, that
mean the Shutter is bottom down, if the report value is 0xFF that mean the Shutter is
at the top. But if report value is 0xFE means the position is unknown.
Binary Switch Get Command:
[Command Class Binary S itch, Binary S itch Get]
Binary Switch Report Command:
[Command Class Binary S itch, Binary S itch Report, Value = 0x00 (BOT-
TOM)]
[Command Class Binary S itch, Binary S itch Report, Value = 0xFE (UN-
KNOWN)]
[Command Class Binary S itch, Binary S itch Report, Value = 0xFF(TOP)]
2-2 BINARY_SWITCH_SET
AN08 can only accept Binary Switch Set Command which value is either (0x00)
Bottom or Top (0xFF), other value is not acceptable.
[Command Class Binary S itch, Binary S itch Set, Value = 0xFF(255)]
control the shutter to the top (0xFF). But if the shutter is on the way down, this
command will stop the shutter.
[Command Class Binary S itch, Binary S itch Set, Value = 0x00(0)]
control the shutter to the bottom(0x00). But if the shutter is on the way up, this
command will stop the shutter.
3. Multilevel S itch Command Class (Version 3):
3-1 MULTILEVEL SWITCH SET:
AN08 can accept Multilevel Switch Set Command which value is either (0x00) Bot-
tom or Top (0x63 or 0xFF) or (0x01-0x62) the position between TO and Bottom.
Other value (0x64-0xFE) is not acceptable.
5

[Command Class Multilevel S itch, Multilevel S itch Set, Value = 0x63 or
0xFF(255)] control the shutter to the top (0xFF)
[Command Class Multilevel S itch, Multilevel S itch Set, Value = 0x00(0)]
control the shutter to the bottom(0x00)
[Command Class Multilevel S itch, Multilevel S itch Set, Value = 0x01-0x62]
control the shutter to the position between Bottom and Top.
3-2 MULTILEVEL SWITCH GET:
When AN08 receive Multilevel Switch Get Command, it will send Multilevel Switch
Report Command to report the position of the shutter. When the report value is 0x00,
that mean the shutter is at the Bottom, if the report value is 0x63 or 0xFF that mean
the shutter is at the top, any other value between 0x01~0x62 imply shutter at the po-
sition between top and bottom.
Switch Multilevel Get Command:
[Command Class Multilevel S itch, Multilevel S itch Get]
Multilevel Switch Report Command:
[Command Class Multilevel S itch, Multilevel S itch Report,
Value = 0x00(BOTTOM)]
[Command Class Multilevel S itch, Multilevel S itch Report,
Value = 0x01~0x62(Bet een BOTTOM and TOP)]
[Command Class Multilevel S itch, Multilevel S itch Report,
Value = 0x63/0xFF(TOP)]
3-3 MULTILEVEL SWITCH START LEVEL CHANGE:
This is the command hich user can move the shutter up to the top or do n to
the bottom.
[Command Class Multilevel S itch, Multilevel S itch Start Level Change,
Up/Do n Value]
3-3.1 Up/Do n Bit:
If Up/Down Bit=0x00 Shutter move up
If Up/Down Bit=0x01 Shutter move down
If Up/Down Bit=0x03 no move
[Command Class Multilevel S itch, Multilevel S itch Start Level Change,
Up/Do n=0x00] control the shutter to the top (0xFF)
[Command Class Multilevel S itch, Multilevel S itch Start Level Change,
Up/Do n=0x01] control the shutter to the bottom (0x00)
[Command Class Multilevel S itch, Multilevel S itch Start Level Change,
Up/Do n=0x03] Don't move the shutter or stop the moving shutter
ATT. 1. Ignore_Start_Level、
Start_Level、
Dimming_Duration、
Inc/Dec、
Step_size can
not be used.
6

2. PAN08 can not control the speed of motor.
3. It may have some distance error caused by motor start up time.
4. If user found the error become significant, you may using S1 or S2 move
shutter to the end or remote move shutter to 0% and 100%, and that will
automatically calibrate this error.
3-3.4 MULTILEVEL SWITCH STO LEVEL CHANGE:
When receive Multilevel Switch Stop Level change Command AN08 will stop the
motor.
4 SCENE ACTIVATION COMMAND CLASS
4-1 Scene Activation Set Command:
When AN08 receive Scene Activation Set command, it will read the level of the pre-
configured Scene ID from EE ROM. And it will be controlled as a Multilevel Switch
Set command that described in 3-1. The Dimming Duration of the command will be
ignored because AN08 can not control the speed of motor.
5 SCENE ACTUATOR CONFIGURATION COMMAND CLASS
5-1 Scene Actuator Configuration Set Command:
[Command Class Scene Actuator Configuration, Scene Actuator Configuration
Set, Scene ID=1~255, Override bit=0, Level=0~99 or 255] The current
setting of PAN08 ill not be override.
[Command Class Scene Actuator Configuration, Scene Actuator Configuration
Set, Scene ID=1~255, Override bit=1, Level=0~99 or 255] The Level
value in this Command is associated to the Scene ID.
5-2 Scene Actuator Configuration Get Command:
[Command Class Scene Actuator Configuration, Scene Actuator Configuration
Get, Scene ID=1~255 ]
[Command Class Scene Actuator Configuration, Scene Actuator Configuration
Report, Scene ID=1~255, Level=0~99 or 255, Dimming Duration=0~0xFE] Report
the Pre-configured Scene ID of PAN08.
6 Z- ave’s Groups introduction (Association Command Class Version 2 )
There is only one group called Group1,there is only one node for Group1 which
support MULTILEVEL_SWITCH_RE ORT、METER_RE ORT_COMMAND_V3、
ALARM_RE ORT.
6-1 Report the shutter position :
Every time when user press S1 or S2 and let shutter to move, AN08 will report the
position status to controller, and at the moving process when change over 10%
AN08 will send Multilevel Switch Report to Group 1 as well.
Multilevel Switch Report:
Ex. Report position at 30%
[Command Class Multilevel Switch, Multilevel Switch Report,Value = 30(%)]
7

6-2 Meter Command Class:
The Switch will report its (1) instant ower Consumption (Watt) or (2) accumulated
power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I ) (5)
load power factor ( F) to Z-Wave Controller after receive the Meter Get Command
from Z-Wave Controller.
When the power consumption of load vary over 5%, it will send Meter report to the
nodes of Group as well
6-2.1 Instant Po er Consumption (Watt) of S itch
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type =
0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W) ]
Example:
Meter Value 1 = 0x00 (W)
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Meter Value 4 = 0xEA (W)
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W
6-2.2 Accumulated Po er Consumption (KW/h)
When receiving Meter Get Command, it will report Meter Report Command to
the node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 (KW/h)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01, Meter Type
=0x01, Precision = 2,Scale = 0x00,Size = 4,Meter Value (KWh)]
Example:
Scale = 0x00 (KWh)
recision = 2
Size = 4 Bytes (KW/h)
Meter Value 1 = 0x00(KWh)
Meter Value 2 = 0x01(KWh)
Meter Value 3 = 0x38(KWh)
Meter Value 4 = 0xA3(KWh)
Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value
3*256) + (Meter Value 4) = 800.35 (KW/h)
6-2.3 AC load Voltage (V)
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]
Meter Report Command:
8

[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type =
0x01,Precision = 1,Scale = 0x04,Size = 2, Meter Value(V)]
Example:
Scale = 0x04 (V)
recision = 1
Size = 2 (2 Bytes of V)
Meter Value 1 = 0x09(V)
Meter Value 2 = 0x01(V)
AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)
6-2.4 AC load current ( I )
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type
= 0x01,Precision = 2,Scale = 0x05,Size = 2,Meter Value(I)]
Example:
Scale = 0x05 (I)
recision = 2
Size = 2 (2 Bytes of I)
Meter Value 1 = 0x01(I)
Meter Value 2 = 0x21(I)
AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)
6-2.5 load po er factor (PF)
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type =
0x01, Precision = 2,Scale = 0x06,Size = 1 Bytes,Meter Value(PF)]
Example:
Scale = 0x06 ( F)
recision = 2
Size = 1 (1 Byte of F)
Meter Value 1 = 0x63( F) (It means that the load power factor is 0.99)
6-2.6 Reset Accumulated Po er Consumption (KWh)
Whenever re-start counting the accumulated power consumption is needed, you can
use Meter Reset Command to clear it.
Meter Reset Command:[Command Class Meter, Meter Reset]
6-3 Alarm Report Command:
When AN08 detect Overload, it will send Alarm_Report to Group1, Alarm Type =
0x08, Alarm Level=0xFF. When receive Alarm_Get command with Alarm Type = 0x08
9

and the AN08 not in overload status , it will send Alarm_Report, Alarm Type = 0x08,
Alarm Level=0x00.
6-3.1 Alarm Report:
When in Two ush Button switch type, S1 or S2 close to L and not been release, and
AN08 receive some control moving command from Z-Wave RF (Ex. BASIC_SET、
BINARY_SWITCH_SET、
MULTILEVEL_SWITCH_SET、
MULTILEVEL_SWITCH_START_LEVEL_CHANGE or
MULTILEVEL_SWITCH_STO _LEVEL_CHANGE or SCENE_ACTIVATION_SET),
AN08 won’t do any change in position but report alarm to Group1 this indicate that
the S1 or S2 not been released.
When AN08 detect a overload power, it will report alarm to Group1
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0xFF
(Overload)]
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0x00
(Normal)]
When in Two ush Button switch type, S1 or S2 are closed and not released to open,
and AN08 receive any control moving command from Z-Wave RF, it will report
alarm to Group1.
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x01, Alarm Level = 0xFF
(S1 or S2 close to L)]
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x01, Alarm Level = 0x00
(S1 and S2 released from L)]
7 Z-Wave’s Configuration
Configuration
Parameter
Function Size
(Byte)
Value Unit Default Description
1 Watt
Meter
Report
eriod
2 0x01-
0x7FFF
5s 720 5*720s=3600s=1
hour
2 KWH
Meter
Report
eriod
2 0x01-
0x7FFF
10
min
6 6*10min= 1 hour
3 Threshold
of current
for Load
Caution
2 10-500 0.01
A500 500*0.01A=5A
4 Threshold
of KWH
for Load
Caution
2 1-
10000
1
KWh
10000
5 External
switch
1 1-2 2 1: One ush button
2:Two ush button
10
This manual suits for next models
2
Table of contents
Other Philio Controllers manuals
Popular Controllers manuals by other brands

Digiplex
Digiplex DGP-848 Programming guide

YASKAWA
YASKAWA SGM series user manual

Sinope
Sinope Calypso RM3500ZB installation guide

Isimet
Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS
LSIS sv-ip5a user manual

Rockwell Automation
Rockwell Automation 1769-L31 installation instructions