Philio PAT14 User manual

Z-Wave Ultra low temperature sensor
PAT14
The Z-Wave Ultra low temperature sensor PAT14 has 2 channel
thermocouple , based on Z-Wave
TM
technolog .
This device is a securit enabled Z-Wave Plus™ product. The
encr pted Z-Wave Plus™ messages support PAT14 to communicate
with other Z-Wave Plus™ products.
PAT14 can be used with Z-Wave™ devices (with Z-Wave™ logo) from
different manufacturers, it can also be included in the Z-Wave™
networks from different manufacturers.
All mains operated nodes (even from different manufacturers) in the
network act as repeaters to increase the stabilit and reliabilit of the Z-
Wave™ network.
The product is supported with Over-the-Air (OTA) feature for firmware
upgrade.
Specification
Rated DC5-24V 6mA
RF distance Min. 40M indoor,
100M outdoor line of sight,
RF Frequenc
868.40 MHz, 869.85 MHz(EU)
908.40 MHz, 916.00 MHz(US)
920.9MHz, 921.7MHz,
923.1MHz(TW/SG/Thai/KR)
RF Maximum Power +10dBm (Peak), -10dBm
(Average)
Dimension 47.5 x 39 x16 mm
Location Indoor use onl
Operation temperature -10°C - 40°C
Storage Temperature -20°C - 60°C
Humidit Up to 85% max
Temperature Detect Range -250 to 300°C
Sensor t pe
External K/J/T t pe
thermocouple
(depend on the user choice)
FCC ID RHHPAT14
Specifications are subject to change and improvement without
notice.
1

Troubleshooting
S mptom Cause of Failure Recommendation
The device can not
join to Z-Wave™
network
The device ma in a Z-
Wave™ network.
Exclude the device
then include again.
Installation Steps
1. Connect 5-24V&GND to 5-24VDC.
2. Connect K/J/T T pe Thermocouple to CH1/CH2.
***When installing a thermocouple, please pa attention to the
positive and negative polarit of the thermocouple. If the
installation is wrong, the temperature measurement will be
wrong.
or Instruction to http:// www.philio-tech.com
Add to/Remove from Z-Wave
TM
Network
There is a button with LED indicator in front of PAT14. It is used to
dim on/off the light and carr out the inclusion, exclusion, reset or
association of PAT14 from Z-wave controller.
When the fist power one, the LED indicator flashes once per second
for 30 seconds. With the SmartStart function, PAT14 will be
automaticall included b Z-wave controller.
PAT14 can be operated with an certified Z-Wave™ devices from
different manufacturers in Z-Wave™ network. All non-batter operating
devices act as repeaters to increase the stabilit and reliabilit of the Z-
Wave™ network.
2

The table below provides an operation summar of basic Z-Wave™
functions. To add/remove/associate PAT14, please refer to the
instruction of certified Z-Wave™ Primar Controller.
unction Description
Without
Node ID
New PAT14 does not have Node ID until it is included
b a Z-Wave™ Controller.
Add
(Classic
Inclusion)
1. Set Z-Wave™ Controller to inclusion mode b fol-
lowing the instructions provided b the controller
manufacturer.
2. Press the button on PAT14 three times within 3 sec-
onds to enter inclusion mode.
SmartStart
1. To initiate the SmartSart process, please t pe in the
first five digits of DSK string or scan the QR code.
The QR Code can be found on PAD15 or in the
box.
Ex: DSK: 18112-24021-58001-62259-57092-
27453-08187-47408
2. PAT14 is supported with SmartStart, it can be
added to Z-Wave™ network b scanning the Z-
Wave™ QR code on the product.
3. Without further actions, PAT14 will be automaticall
included in a certified Z-Wave™ Controller with
SmartStart inclusion abilit in 10 minutes after it
turned on.
Remove
(Exclusion)
1. Set our Z-Wave™ controller to exclusion mode b
following the instructions provided b the controller
manufacturer.
2. Press the button on PAT14 three times within 3 sec-
onds to enter exclusion mode.
3. Node ID will be excluded.
Reset
1. Press the button of PAT14 four times within 3 sec-
onds and hold the last press until the LED light
turns off.
Adding a node ID allocated by Z-Wave™ Controller means
inclusion. Removing a node ID allocated by Z-Wave™
Controller means exclusion.
The situation of including/excluding of the node ID can be
checked from the Z-Wave™ Controller.
unction Reset: The Reset procedure can only be used
when PAD15 cannot be recognized by the Z-Wave™
Primary Controller.
Notice 1: Alwa s RESET a Z-Wave
TM
device before tr ing to add it to a
Z-Wave
TM
network
LED Light Indication
The LED light indicates the different modes of the PAD15
State Type LED Indication
Without
Node ID
Under normal operation, when the PAD15 has
not been allocated a node ID, the LED light will
flash on and off alternatel at 1-second intervals.
B pressing the On/Off button, LED light will stop
flashing temporaril .
Learning Flashes when learning is successful
Z-Wave
TM
Multi Channel Association
PAT14 just be set to send reports to multi channel associated Z-
Wave™ devices. It supports five association groups with five nodes
support for group 1 ~ group 5.
Group 1, the will report
3

DEVICE_RESET_LOCALLY_NOTIFICATION.
Group 2, End Point 1 will report ( channel 1)
SENSOR_MULTILEVEL_REPORT_TEMPERATURE
Group 3, End Point 2 will report ( channel 2)
SENSOR_MULTILEVEL_REPORT_TEMPERATURE
Group 4, End Point 1 will report (channel 1)
NOTIFICATION_REPORT_HEAT_V4
Group 5, End Point 2 will report (channel 2)
NOTIFICATION_REPORT_HEAT_V4
Z-Wave
TM
Notification
This function default is disable, to enable this function b setting the
configuration NO.3 bit4~7.And set threshold b setting the
configuration NO.11 ~ 14.
Z-Wave
TM
Message Report
* Temperature differential report:
This function default is enabled, to disable this function b setting the
configuration NO.7 to 0.
In the default, when the temperature is changed to plus or minus 0.5
degree Celsius, the device will report temperature information to the
nodes in the lifeline group.
The device will measure the temperature in ever 1 seconds. And if the
temperature is over 140 degree Fahrenheit (60 degree Celsius), the
device will alwa s report in each measurement.
* Timing Report:
The device support the timing unsolicited report of the status.
•Temperature report: Ever 1 hours report once in default.
It could be changed b setting the configuration NO. 5.
Notice: The configuration NO. 5 could be setting to zero to disable the
auto report. And the configuration NO. 6 could change the tick interval,
the default value is 12, if setting to 1, that means the minimum auto
report interval will be one minute. And please notice if setting this value
to zero, that means disable all of the timing report except the low
batter detection.
Over The Air (OTA) irmware Update
The device support the Z-Wave firmware update via OTA.
Let the controller into the firmware update mode, and then press the
tamper ke once to start the update.
At that time, please don't remove the battery, otherwise it will cause
the firmware broken, and the device will no function.
After the LED stop flash, it is recommended that the user power up the
device. Caution: After remove the batter , please wait about 30
seconds, and then re-install the batter .
Z-Wave Configuration Settings
Notice:
* All of the configuration, the data size is 1.
* The configuration mark with star(*), means after the remove the
setting still keep, don't reset to factor default. Unless the user execute
the “RESET” procedure.
* The reserve bit or not supported bit is allowed an value, but no effect.
4

NO. Name Def.
Valid
Description
1Operation
Mode
All Bit control.
0Bit0: reserve.
0Bit1: reserve.
0Bit2: reserve.
1Bit3: Set temperat re nit.
0: Fahrenheit 1: Celsi s
0Bit4: CH1 overheat notification
0:disable 1:enable
0Bit5: CH1 nder heat notification
0:disable 1:enable
0Bit6: CH2 overheat notification
0:disable 1:enable
0Bit7: CH2 nder heat notification
0:disable 1:enable
2 C stom
F nc
All Bit control.
01
Bit0、Bit1: Set CH1 thermoco ple
type
00 → disable,01 → K-type
10 → T-type,11 → J-type
0Bit2: reserve.
00
Bit3、Bit4: Set CH2 thermoco ple
type
00 → disable,01 → K-type
10 → T-type,11 → J-type
0Bit5: reserve.
0Bit6: reserve.
0Bit7: reserve.
NO. Name Def.
Valid
Description
3
A to
Report
Temperat
re Time
50 ~
127
Temperat rn a to report time
0 : disable.
Defa lt is 5. Tick Interval can
setting by config ration No.4.
4
A to
Report
Tick
Interval
12 0 ~
0xFF
The interval time for a to report
each tick. Setting this config ration
will effect config ration No.3.
Units of one min te.
Ca tion1:
Setting to 0 means
t rn off all a to report f nction.
Ca tion2
: The val e is nsigned
byte, the range is from 0x00 ~
0xFF.
5
Temperat
re
Differenti
al Report
00 ~
127
The temperat re differential to
report.
0 means t rn off this f nction.
The nit is Celsi s.
And when the temperat re is over
140 degree Fahrenheit, it will
contin e report.
6
CH1
Temperat
re High
threshold
32767 int16 CH1 overheat notification threshold.
7
CH1
Temperat
re Low
threshold
-32768 int16 CH1 nderheat notification
threshold.
8 CH2 32767 int16 CH2 overheat notification threshold.
5

NO. Name Def.
Valid
Description
Temperat
re High
threshold
9
CH2
Temperat
re Low
threshold
-32768 int16
CH2 nderheat notification
threshold.
Z-Wave Supported Command Class
Command Class Version Required Securit Class
Z-Wave Plus Info 2 None
Transport Service 2 None
Securit 0 1 None
Securit 2 1 None
Supervision 1 None
Version 3 Highest granted Securit Class
Configuration 4 Highest granted Securit Class
Association 2 Highest granted Securit Class
Association Group Info 3 Highest granted Securit Class
Notification 8 Highest granted Securit Class
Version 3 Highest granted Securit Class
Device Reset Locall 1 Highest granted Securit Class
Indicator 3 Highest granted Securit Class
Powerlevel 1 Highest granted Securit Class
Multi Channel 4 Highest granted Securit Class
Firmware Update Meta Data 5 Highest granted Securit Class
Multilevel Sensor 2 Highest granted Securit Class
CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used battery according to the instructions.
Choosing a Suitable Location
1. The suitable ambient temperature for the module/device is
-10°C~40°C.
2. Do NOT place the module/device direct under sunlight, in a humid
place or in an location where the ma contact moisture, dirt, dust.
3. Do NOT place the module/device where exists combustible
substances or an source of heat, fires, radiators, boiler etc.
Disposal
This marking indicates that this product should not
be disposed with other household wastes throughout
the EU. To prevent possible harm to the environment
or human health from uncontrolled waste disposal,
rec cle it responsibl to promote the sustainable
reuse of material resources. To return our used
device, please use the return and collection s stems
or contact the retailer where the product was
purchased. The can take this product for
environmentall safe rec cling.
Philio Technolog Corporation
8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei Cit
24257, Taiwan(R.O.C)
w ww.philio-tech.com
6

CC Interference Statement
This equipment has been tested and found to compl with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates,
uses and can radiate radio frequenc energ and, if not installed and
used in accordance with the instructions, ma cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined b turning the equipment off and
on, the user is encouraged to tr to correct the interference b one of
the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for
help.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device ma not cause harmful interference, and
(2) This device must accept an interference received, including
interference that ma cause undesired operation.
FCC Caution: An changes or modifications not expressl approved b
the part responsible for compliance could void the user's authorit to
operate this equipment.
This transmitter must not be co-located or operating in conjunction with
an other antenna or transmitter.
Warning
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities. Contact our local government for
information regarding the collection s stems available. If electrical
appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging
our health and well-being.
When replacing old appliances with new once, the retailer is legall
obligated to take back our old appliance for disposal at least for free of
charge.