Pichler WPS A3 User manual

Manual for use of PICHLER Whirlpool
spa control system WPS A3
PICHLER Kunststofftechnik GmbH
Lauterbachstraße 19
84307 Eggenfelden
Phone:
Fax:
Email:
Web:
date:
0 87 21-96 90 0
0 87 21-96 90 20
mail@pichler.de
www.pichler-whirlpool.de
2012/05

january 2012
Contents
spa controler system manual for customer WPS A3
user panel.........................................................................................
2
LCD Display, Symbols on display......................................................
3
Reset-Button of display (invisible), Menu items, kids safety.............
4
Programing keys, Jet-Pumps, Air blower, Pool lighting...................
4
Menu customer.................................................................................
5
Set temperatur, Date, Time..............................................................
5
Heat exchange, Heating cykles, Heating days.................................
6
Heating when filtering, Heating during bath, Flushing cycles...........
7
Ozon during at badh On/Off..............................................................
7
Factory settings, saving, loading, .....................................................
8
Display contrast, Intervall massage..................................................
8
Illumination, Door lighting, Stairs/Entry lighting.................................
9
Userpanel lighting, Pool lighting.......................................................
9
Outside lighting, Synchron lighting ..................................................
10
Options: exchange heating, automatic water control inlet................
11
malfunction.......................................................................................
12
PICHLER Kunststofftechnik GmbH
page1 of 12

spa Control system
Control element
PICHLER Kunststofftechnik GmbH
page 2 of 12
LCD - Display
Reset - Button (invisible)
Jet - Pumps
Air - Blower
Pool Illumination
(Underwater flood light , light of stairs, Service-door)
Programming - Keys
Whirlpool Controler
Control element
Hand of rotation left
Hand of rotation right
LCD - Display
LCD display on the operating conditions are indicated. So you can see trouble and alarm code as
well as the respective setting data in Progamming mode. The display shows lines up to fourth If there
are out of the more lines display a range simbol like an arrow will be shown on right side.
The LCD display on the display of the operating condition of the spa is shown, also
warning and error messages are displayed, as well as the respective setting in the programming
mode. The display can display up to 8 lines in the window. If additional lines outside
the visible range of the display is, is this right to a symbol in the form of a arrow appears.
si
The control element Consists of a LCD display, the operating keys of activating jet pumps, air blowers
and pool light, the RESET button and the programing keys. Figure shows the front panel of the spa
and provides Provides an overview ofeach key that you need to start some already. Detailed explanations
of usingl and programing of the adjustments to follow later in the appropriate sections.
january 2012

Logo
This logo will be shown for 5
seconds after starting up or after
pushing the RESET-button.
Below is the latest right here
Software version is displayed.
PICHLER Kunststofftechnik GmbH
page 3 of 12
V 2.69 Software-version
Explantation of symbols on display
data, weekday,time
heating activated
filter operation
curent temperature of pool water
air blower activated
set temperatur
activ Jet-pumps
( 1-3 pumps, depending on model )
07.07.2011 Tu 13:15
36.7°C
Set temp. 36.9°C
To operate of heating exchanger with Symbol dazzle.
Is heating exchange out of operate, or rather it is low temperature
in accumulator, changing this symbol to normal electro heating
operation.
Operate whit internal end activite heat exchanger
Base picture
january 2012

PICHLER Kunststofftechnik GmbH
january 2012
Whirlpool controller
Control element
LCD-Display
Reset- button
The displays shown in the display is reversible, so that they both foreign, as well as the
Inside the spa is readable. The change of the display is done using the following
Key: - to read the display from outside the pool
- to read the display from within the pool
-
„▼“
Advice Reporting text on LCD-Display
Spa controller detects errors and advises on display.
This may avoid must be closed, that the spa will operating normal.
(Read the pages vor „errors and advices“)
Kids safety lock
Kid lock one of the buttons combination activate or deactivate (disable).
Push the bottom up and down syncronistic (at once) to lock from displays.
To unlock for childres shoring actualition „RESET“ button or once again, syncronistic
pushing up and down buttons.
.:
Jet - pumps
Each actuation of key switch on sequential jet pump (depending on)
1, 2 and 3 on or rather off
Air-blower
You swich on and off the air blower
Pool illumination (LED therapie lamp with light dimming)
With this key you can switch on or off the pool so you can dim light and luminance stageless.
By pushing the button a second longer then helped the dimming function will be activated.
If you push the button longer will change luminace first until maximum and minimum until
then also be turned on with the service-door illumination then automatically after a time
5 min ago 15min. switch off automaticly.
.
„▲“
Note: The conversion only works in the base screen (see ) page 3
„▼“
„▲“
„▼“
„▲“
page 4 of 12

PICHLER Kunststofftechnik GmbH
january 2012
page 5 of 12
36.7
set temp.
menue customer
more
you push the arrow up or down
to set the desired bathing temperature.
With the button "Ok" to save now on the temperature .
To switch from the menu to the base screen, wait
1 minute to the image jumps back automatically, or press
the down arrow, and than click "Next" and than on
the "OK" button until you return to the base screen.
(pic 3)
„▼“
„▲“
„▲“
set temp.
menu customer
more
36.7
menue customer
more 36.7
set temp.
„▼“
Go to the Customers menu to "Once More."
Use the arrow key up the line with
the date or time. Then confirm with
with the "OK" button.
You can now use the arrow key or sequentially
Day, month, year, or hours, minutes, seconds set
confirm, then the "OK" button each setting.
(pic. 4)
(pic.5)
menu customer
back 36.7
set temp.
more settings
factory settings
intervall massage
lillumination
„▲“
„▼“
„▲“
more settings 1
flashing off
tame 08:22
filter time
heating time
flashing time
0 6.07.11
pic. 1
pic. 2
pic 3
pic. 5
pic.4
07.07.2011 TU 13:15
ph-electrode ph: --.--
redox-elect mV: -----
chlor-elect. ppm: -----
Menu customer
07.07.2011 TU 13:15
36.7°C
Set.temp. 36.9°C 36.7
set temp.
menu customer
more
1. you could going to base picture
2. In the „menu customer“ gelangen Sie wie folgt: Drücken Sie 3 x hintereinander die „OK“ Taste.
( )step: 1
step: 1 step: 2 step: 3
settings ê
settings
menu customer
menu
back
step: 4
cus
service
more
you push the 1 button "OK", then the menu appears
with the set point of temperature setting
.
Then use the up arrow key on "OK" button
Press select to set the target temperature
(pic. 1)
(pic 2)
Temperatur setting
Date and Time Setting
date

PICHLER Kunststofftechnik GmbH
january 2012
page 6 of 12
Filter time
Press the " menu customer" to "more settings
than you can push the arrow buttonto the up
First Filter time and go to the bar afterwards with the
"OK" button to set mark.
Now use the arrow keys to select the desired filter time
set and confirm with "OK" button.
It can be set 4 different filter times.
If no filters required time in a row or registered
have 00:00 - 12:00 will be set in the line.
Warning:The heating time and the filter to time should be same!
„▲“
filter time
back
1: 00:01 - 06:00
2: 08:00 - 10:00
3: 10:05 - 17:00
4: 18:00 - 23:59
heat time
back
2: 08:00 - 11:00
3: 13:00 - 17:00
4: 18:00 - 23:59
So Mo Tu We Th Fr Sa
0:01 - 06:00 0
more settings 1
flashing off
tame 08:22
filter tame
heat tame
flaching tame
back
0 6.07.11 0 6.07.11
„▲“„▼“
Heating time
Press the " menu customer" to "more settings
Then you can click the arrow to the up
First Heating time and the bar then go to the
"OK" button to set mark.
Now use the arrow keys to select the desired heating
Set and confirm with "OK" button.
It can be set 4 different heating times.
If no heating required in a row, or registered
have 00:00 - 12:00 will be set in the line.
Warning: The heating time and the filter time should be the same!
„▲“
„▲“„▼“
Heat days
„AKTIVATED“ or „DEAKTIVATED“.
In this example, the heating days Sunday and Monday (Sun, Mon)
disabled.
Heating only, the black days.
„▲“
„▲“„▼“
heat time
back
2: 08:00 - 11:00
3: 13:00 - 17:00
4: 18:00 - 23:59
So Mo Tu
We
Th Fr Sa
00:01 - 06:00
1:
more settings 1
flushing off
time 08:22
filter time
heat time
fluching tame
back
0 6.07.12 06.07.1
more settings 1
flushing off
time 08:22
filter time
heat time
flushing time
back
0 6.01.12 0 6.0
more settings 1
flashing off
time 08:22
filter time
heat time
flashing time
back
0 6.07.12 06.07.
Press the " menu customer" to "more settings
Than you can click the arrow to the up
Heating days whit "OK" button mark.
Now use the arrow keys
date
date

PICHLER Kunststofftechnik GmbH
january 2012
page 7 of 12
For example, filters and heating times setting
The time setting for heating and filtering should be set equal
be to keep track of the setting.
Shown is a typical setting, if during the night
no noise in residential areas are desirable.
ATTENTION:
It still needs a minimum set of filter time 15 hours
be to ensure optimum water quality.
The automatic dosing system works only when the
Filter operation!
filter times
back
1: 07:00 - 22:00
2: 07:00 - 22:00
3: 07:00 - 22:00
4: 07:00 - 22:00
back
2: 07:00 - 22:00
3: 07:00 - 22:00
4: 07:00 - 22:00
So Mo Tu We Th Fr Sa
07:00 -
heating times
1:
flashing times
back
1: 09:00 - 09:00
2: 15:00 - 15:00
3: 20:00 - 20:00
4: 22:00 - 22:00
more settings 1
date 06.07.12
time 08:22
filter time
heat time
flushing Aus
flushing time
back
more settings 1
date 06.07.12
time 08:22
filter times
heat times
flashing oOff
flashing times
back
more settings 2
ozon during bath On
Flushing times setting
Under the menu item "More Settings", select
"Flush times".
There are 8 different programmable flush times.
Usually meet four different times as in the example image
is seen.
In the scavenging process of pre-programmed for a period of
5 sec.is to be activated all pumps, blowers and motors for mixing
all points in the tubes with disinfecting bleach to clean them.
Flashing manually select
Under the menu item "More Settings", select
"flashing".
Press the "OK" button, then select it with the cursor
up "on" confirm with "OK" button.
Now, the flashing process is running for 5 seconds.
Ozon at bath
Under the menu item "More Settings", press the
Up arrow key until you get to .
Select the desired option.
You can use the ozone while bathing "ON" or "OFF"
choose.
Have you selected the "ozone in the bath" to "OFF", turns
the ozone device off as soon as a pump or blower turns on.
page 2
page 2
22:00

PICHLER Kunststofftechnik GmbH
january 2012
page 8 of 12
Factory setting
Select the menu item "menu customer", default ( ).
Setting secure: To On / Off , press the button settings with secure
the "OK" button appears with the arrow facing up to
then "ON" to save the changes, once again the "OK"
Button. ( )
Setting load: To On / Off settings, press the button setting overloaded with
the "OK" button appears with the arrow facing up to
then "ON" to load the changes, once again the "OK"
Button. ( )
Factory settings. To On / Off (Here, the changed settings
The factory defaults are reset.
If before a backup is created, you can also re-loading!
Display contrast: 1-150 (The contrast can range from the level
1-150 be changed. Select the optimum level for you.
Pic.1
Fig. 2
Fig. 2
Warning: Please after each change you want to backup
the setting must be secured
Beleuchtung
menu customer
back 36.7
set temp.
more settings
illumination
Intervall massage
factory setting
Intervall massage
The intervall massage setting can be found under the menu item
"more settings". Select "intervall massage."
Select the intervall for massage by "1 second" both
buttons (see „page 2 "controls) pressed.
Clear the intervall for massage by "1 second" both
keep the buttons pressed again.
Single: from On (The interval of each operating unit can massage
be separately switched „on“, or „off“.
Single user: Off (The intervall of each massage can control part of
all valves are on or off.
Massage duration: 0-30min. (The massage is for the set intervall
active time and than switches off automatically).
Massage level: 1-15 (1 = slowest speed interval, 15 = fastest speed)
menu customer
back 36.7
set temp.
more settings
factory setting
illumination
intervall massage
interval massage
massage step 15
massage time 25
single seat on
Pic.1
Pic 2
„▲“
„▲“back
factory setting
factory setting
setting save
On
setting load
userpanel contrast 90
Off
Off
back
i

PICHLER Kunststofftechnik GmbH
january 2012
page 9 of 12
Lighting, door lighting
Under the menu item "customer menu" choose "light".
Tuerbeleuchtung: On (The service door interior light is switched on,
and may the Light button (see page 2) off again
be).
Tuerbeleuchtung: OFF (The service is door-Interior light off).
Automatic shutdown: The service door interior lighting
with the "lighting (see S 2) is always automatically for 15 min.
turned on, and then switches off again.
menu customer
set temp.
more settings
factory settings
illumination
Intervall massage
back 36.7
syncron lighting
door off
stairs lighting
back
illumination
pool lighting
outside lighting
userpanel lighting
Beleuchtung
synchron lighting
door off
back
illumination
pool lighting
outside lighting
userpanel lighting
stairs lighting
Beleuchtung
Zurueck
color auto
selection off
color exchange 10s
stairs lighting
back
color blue
userpanel lighting.
back
color exchange dim
synchron lighting
back
pool lighting
outdside lighting
userpanel lighting
doort
door off
illumination
Lighting, stair lighting
The menu item "stair light", the following selection
be taken:
Color change: cycle in seconds selectable 1-120 seconds
Colour: Automatic: (automatic switching of all colors)
Single: auto, red, green, yellow, blue, purple, aqua, white
Selection: On, Off
Car (the stair lights turn on with activity
Press "Light" (see page 2) for 5 min. , and then switches
again automatically.
Lighting, panel lighting and pool lighting
The menu item "panel lighting and pool lighting"
The following selection can be made:
Brightness: Level 1-50 seconds adjustable (only available when the
different colors!)
Color change: cycle in seconds selectable 1-120 seconds
(is less like 1 second to select appears
"dim")
Color: Single: auto, red, green, yellow, blue, purple, aqua, white
dim: (automatic switching of all colors)
Color change: cycle in seconds selectable, 1-120
Beleuchtung
back
color white
coler exchange 1s
userpanel lighting.
brightnes 50
Warning: When selecting the "dim" feature, the colors
automatic-dimming up and down.
Selection: Menu -> Color: "Single" Here, all
Options are also selected.
stairs lighting

synchron lighting
door lighting off
stairs lighting
userpanel lighting
illumination
pool lighting
back
outside lighting
PICHLER Kunststofftechnik GmbH
january 2012
page10 of 12
The menu item "Outdoor Lighting", the following selection
can be set:
Color change: cycle in seconds selectable 1-120 seconds
Colour: Automatic (automatic switching of all colors)
Single: auto, red, green, yellow, blue, purple, aqua, white
Selection: On, Off
Automatic (the stair lights turn on with activity
press "Light" (see S 2) for 5 min. , and then switches
again automatically.
Outseid lighting time: There are 4 different outdoor lighting times
programmable: e.g. 1: 17:00 - 23:00 clock.
(Only this time, turn the outside lights,
if the selection: "AUTO" is set).
Outdoor Lighting menu customer
set temp.
more setting
illumination
Intervall massage
back 36.7
Lighting, synchronized lighting
In the menu item „Synchron lighting“, the following selection
can be set:
Color change: cycle in seconds selectable 1-120 seconds
Colour: Automatic (automatic switching of all colors)
Single: auto, red, green, yellow, blue, purple, aqua, white
Selection: To select a synchronous lighting to Hook
„on“ or without a hook „off“.
Stairs, control panel, underwater light and exterior lighting
can be linked together so that all LEDs
simultane working with the same color light.
outside light time
back
1: 17:00 - 23:00
2: 17:00 - 23:00
3: 17:00 - 23:00
4: 17:00 - 23:00
door off
stairs lighting
userpanel lighting
illumination
pool lighting
synchron lighting
back
outside lighting
menu customer
set temp.
more settings
setting up
illumination
Intervall massage
back 36.7
Beleuchtung
back
color yellow
coler exchange 10s
outside lighting
outside light time
selection on
color exchange 5s
color auto
stairs lighting
syncron lighting
userpanel lighting
outside lighting
back
pool lighting
Warning: The dim-function in the control panel and pool lighting
works only if the synchronous lighting the "hook" are
turned off!
factory setting
„„

PICHLER Kunststofftechnik GmbH
january 2012
page 11 of 12
Heat exchanger
Under the menu item "Customer Menu", select the arrow button
up to page 2
Then press the menu item "heat exchanger".
In this menu you can choose from when the temperature
should turn on the electric heater.
The adjustable "delay" means that only when these
temperature is still well below the electric heating
is activated.
(Will be avoid with that the heating reservoir and the electrical
heating constantly switch on-off).
If you are in the base menu, press in once on the "OK" button
than you see the current temperature heat storage value.
(as example here, on the display will be shown heating exchanger °C: 69.2).
heat exchanger
temperatur range
delay
back
°C
°C 52
5
page 2
menu customer
36.7
set temp.
more settings
factory settings
intervall massage
illumination
back
more settings 2
ozon during bath on
heat exchanger ê
07.07.2012 TU 13:15
setting ê
heath exchange
PH-elect.
redox-elect.
chlor-elect.
°C:
ph:
mV:
ppm:
69.2
-.-
----
----
Warning: On the main screen (Page 3) appear alternately
the heat exchanger or the E-heath symbol
It appears the current operational status!
Water inlet
This function is not working, or from one of our dealers
set and activated.
It is here, depending on the current water pressure of the water line
Will follow-up time of Water "Delay" is set.
This prevents unnecessary short activate and deactivate the water-
Level sensor.
auto water inlet
delay
back
selection on
5s
Warning: The water activity makes waves into the spa, so the water level senor will make
malifunctions. So can set the specially overflow time, to reduce the switch on/off
activity of water waves into the spa. This time to set in seconds should be overfilling
the water into the spa about 1cm more waterlevel from the point of sensor signal.

PICHLER Kunststofftechnik GmbH
page 12 of 12
Malfunction
Beleuchtung
Cause of error
troubleshooting
customer menue can not
activation customer menue
opening
- go to customer menue, (page 5), overhead should be read
menue „settings“.
- Push, und keep the button „OK“ longer as 15 seconds
until the customer menue will be reactivated!
- Please move to the menue „factory settings“ (page 8)
process saving „setting save“. (activation !)
- Alternate: Move to (page 8) „factory settings“, the option:
„factory setting.“
the heater goes not up
to the shall temperature
(water will cool down)
- got to the service menue, and press the button
factory settings
Please note: Before restore to factory setting, please make sure
to safe the customer data. (page 8)
confused digits on the
display
- got to the service menue, and press the button
factory settings
Please note: Before restore to factory setting, please make sure
to safe the customer data. (page 8)
january 2012
Table of contents
Popular Control System manuals by other brands

Thermo Scientific
Thermo Scientific CC58114PC Installation and operation manual

HERA
HERA POWER PACK 2500 User manual & installation guide

Avalon Instruments
Avalon Instruments STARGO GOTO user manual

Triangle MicroSystems
Triangle MicroSystems PETROSMART EZ installation instructions

dji
dji A3-AG user manual

Varifan
Varifan MSC-10 user guide