pickeringtest.com
PXI Very High Density Versatile Multiplexer 40-612A
ISSUE 1.3 JUN 2022
Supported by
eBIRST
eBIRST switching system test tools simplify fault-finding by
quickly testing the system and graphically identifying the
faulty relay.
For more information go to: pickeringtest.com/ebirst
yVersatile Multiplexer - For Now & The Future
yFlexible Software Configured Architecture Can be
Set to Different Configurations as Needs Change
y8-Bank 8-Channel 2-Pole Multiplexers, 1-Pole
Selection, Inter-bank Connection & Isolation Switching
yMany Different Configurations up to a Single
128-Channel 1-Pole Multiplexer, Including Mixed
Channel Count & Custom Configurations
yMaximum Current 2 A Hot or Cold Switching
ySwitch up to 300 VDC/250 VAC & up to 60 W Max Power
yIsolation Switches Reduce Capacitive Loading
in Large Systems
yVISA, IVI & Kernel Drivers Supplied for Windows
ySupported by PXI or LXI Chassis
ySupported by
eBIRST
™
y3 Year Warranty
Pickering’s Range of Versatile Multiplexer Modules
with the same switching architecture
Model
No.
Max
Voltage
Max
Current
Operate
Time
Relay
Type
40-612A 300 VDC/
250 VAC 2 A 3 ms Electro-
mechanical
40-681A ±60 V 350 mA 200 µs Solid State
40-682A ±40 V 250 mA 80 µs Solid State
40-683A ±100 V 125 mA 500 µs Solid State
Typical Congurations
8 Banks, 16 Channels, 1-Pole
8 Banks, 8 Channels, 2-Pole
4 Banks, 32 Channels, 1-Pole
4 Banks, 16 Channels, 2-Pole
2 Banks, 64 Channels, 1-Pole
2 Banks, 32 Channels, 2-Pole
1 Bank, 128 Channels, 1-Pole
1 Bank, 64 Channels, 2-Pole
The 40-612A Very High Density Versatile Multiplexer
module features a wide range of software selectable
switching configurations. It is especially useful where
a high density MUX array is required that can adapt to
different test configurations for different test targets, or
where a test system may have to be reconfigured in the
future. Typical applications include signal routing in ATE
and data acquisition systems. The 40-612A uses high
quality electro-mechanical relays, connections are made
via a front panel 160-pin DIN 41612 connector.
MUX Configurations
The module can be software configured as one of a
large number of different multiplexers. Relays allow the
banks to be set as 1 or 2-pole and inter-bank switching
allows a maximum of 128 channels (refer to schematic
diagram overleaf).
The versatility of the 40-612A’s architecture allows all
banks to be inter-linked and common connections used as
extra signal inputs.
The 40-612A can be operated as a conventional multiplexer
with break-before-make action when a new channel is
selected. Alternatively, product variants can be supplied
that allow multiple channels to be simultaneously selected.
Isolation switching connects only the currently active
multiplexer bank to the analog common, keeping capacitive
loading and leakage currents in large multiplexer systems
to a minimum. Larger multiplexers may be constructed by
daisy chaining the common signals from multiple modules.