Page 1.1
PXI/PXIe 1000BASE-T1 DUAL MUX WITH FAULT INSERTION 40/42-204
pickering SECTION 1 - TECHNICAL SPECIFICATION
SECTION 1 - TECHNICAL SPECIFICATION
pickeringtest.com
PXI/PXIe 1000Base-T1 Dual MUX With Fault Insertion 40/42-204
ISSUE 1.3 MAY 2022
yAvailable as PXI or PXIe Modules
ySuited for 1000Base-T1/100Base-T1 Switching
yFault Insertion on 1 or 2 Channels of 2 Wire
Connections
yDual MUX for External Systems
yControlled Transmission Line Impedance
ySimple Insertion of Shorted Pair, Open and
Battery/Ground Connection
yVISA, IVI & Kernel Drivers Supplied for
Windows
ySupported by PXI or LXI Chassis
y3 Year Warranty
Fault Connections
FB1 FB2
M+
M-
M-LOOP+
M-LOOP-
U+
U-
U-LOOP+
U-LOOP-
40/42-204-001 Single Channel 1000Base-T1
Fault Insertion Switch Schematic Diagram
The 40-204 (PXI) and 42-204 (PXIe) are designed
to simulate common faults on high-speed two wire
communication interfaces such as 1000Base-T1. They
support 1 or 2-channels of two wire serial interfaces. Each
channel pair can be looped out to external equipment or
the switches can be used simulate a channel open fault.
Using the fault bus, switches can simulate a short between
both wires or a short to one of two externally applied fault
conditions – such as battery supply or ground - via two
fault buses.
Each channel can carry up to 0.8 A and is rated up to 200 V
between wire pairs. The wire pairs have controlled
transmission line impedance suited to most differential
Pickering’s Range of Fault Insertion Switches
Model No. Signal
Channels
Fault
Buses
Fault
Inputs
Max
Voltage
Max Current
or Bus Type
40-190B 74, 64 or 32 1 or 2 4 or 8 165 V 2 A
40-191A 6 2 2 40 V 30 A
40-192 6 2 2 200 V 10 A
40-193 7 1 or 2 1 or 2 16 V 20 A, 1 A min
40-194 7 1 or 2 1 or 2 16 V 20 A, no min
40-195 22 or 11 pairs — 8 or 4 150 V 1 A
40-196 10 or 5 pairs — 10 or 5 110 V 5 A
40-197A 34 or 16 4 8 300 V 2 A
40-198 20 1 or 2 3 or 6 250 V 5 A
40-199 10 1 or 2 2 250 V 10 A
40-200 4 or 8
differential 4 8 100 V CAN, FlexRay
40-201 4 or 8
differential 2 4 100 V Ethernet/AFDX
/BroadR-Reach
40-202 22 or 11 pairs — 22 or 11 150 V 1 A
40/42-204 1 or 2
differential 2 2 200 V 1000Base-T1
signalling systems, including high-speed 1000Base-T1,
the fault buses are capable of carrying 0.8 A and also
have controlled transmission line impedance. The front
panel signal connectors are easy to use MMCX which are
fully supported by our range of connector accessories.
The module uses high quality electro-mechanical relays
designed for high frequency application with long service
life.
Differential Bus Switching
We also offer the 40-736 and 40-737 multiplexers which
are suitable for switching Ethernet, USB and other serial
communications signals.