Page 1.2 50Ω 600ΜHz TERMINATED RF MUX 40-761/763/765/767
pickering
SECTION 1 - TECHNICAL SPECIFICATION
600 MHz Terminated RF MUX, 40-761/3/5/7
pickeringtest.com
Specifications
RF Specification
RF Frequency Range: DC to 600 MHz
Impedance 50 Ω
Insertion Loss: Typically <0.5 dB to 100 MHz
Typically <3 dB to 600 MHz
VSWR: Typically <1.3:1 to 100 MHz
Typically <1.6:1 to 600 MHz
Isolation (all channels
off):
Terminated versions:
Typically >80 dB to 100 MHz
Typically >70 dB to 600 MHz
Unterminated versions:
Typically >75 dB to 100 MHz
Typically >50 dB to 600 MHz
Crosstalk: Typically <-60 dB to 100 MHz
Typically <-45 dB to 600 MHz
Maximum RF Power: 0.25 W (terminated versions)
Power Requirements
+3.3 V +5 V +12 V -12 V
0.18 A 1.15 A 0 0
Operating/Storage Conditions
Operating Conditions
Operating Temperature:
Humidity:
Altitude:
0 °C to +55 °C
Up to 90 % non-condensing
5000 m
Storage and Transport Conditions
Storage Temperature:
Humidity:
Altitude:
-20 °C to +75 °C
Up to 90 % non-condensing
15000 m
PXI & CompactPCI Compliance
The module is compliant with the PXI Specification
2.2. Local Bus, Trigger Bus and Star Trigger are not
implemented.
Uses a 33 MHz 32-bit backplane interface.
Safety & CE Compliance
All modules are fully CE compliant and meet applicable
EU directives: Low-voltage safety EN61010-1:2010,
EMC Immunity EN61326-1:2013,
Emissions EN55011:2009+A1:2010.
Mechanical Characteristics
Single or dual slot 3 U PXI (CompactPCI card).
3D models for all versions in a variety of popular file
formats are available on request.
Connectors
PXI bus via 32-bit P1/J1 backplane connector.
Signals via front panel SMB connectors as detailed in User
Manual.
Switching Specification (excluding terminations)
Switch Type: Electro-mechanical
Contact Type: Palladium-ruthenium, Gold
Covered Bifurcated contact
Maximum Switching
Voltage:
30 VDC
Maximum Current: 1 A
Operate Time: 10 ms typical
Expected Life (operations)
Very low power load:
Low power load:
Full power load:
>1x108
>1.5x107 (0.1 A, 20 VDC)
>5x106 (1 A, 30 VDC)
RF Performance Plots
RF plots up to 1 GHz for all versions in the 40-761 range
are shown in the User Manual for:
• Insertion Loss
• VSWR
• Crosstalk