16 BANK, 5 CHANNEL, 1-POLE MULTIPLEXER MODULE 40-616A
pickering SECTION 1 - TECHNICAL SPECIFICATION
SECTION 1 - TECHNICAL SPECIFICATION
pickeringtest.com
PXI 16-Bank, 5-Channel, 1-Pole Multiplexer 40-616A
ISSUE 1.0 FEB 2019
Supported by
eBIRST
eBIRST switching system test tools simplify fault-nding by quickly
testing the system and graphically identifying the faulty relay.
For more information go to: pickeringtest.com/ebirst
• 16 Separate Multiplexers in One Module
• Each Multiplexer is Single Pole, 5-Way
• Features Isolation Switches to Reduce Signal Loading
• Inter-Bank Linking Relays Allow Multiplexer
Size to be Increased in Multiples of 5
• Multiplexer Channels Can be Set Individually
• Any Number of Multiplexer Channels Can be
Set Simultaneously
• Switches Up To 100 Volts, 1 Amp, 20 Watt.
• Uses High Reliability Ruthenium Reed Relays
for Maximum Performance
• VISA & Kernel Drivers Supplied for Windows
• Supported by PXI or LXI Chassis
• Supported by
eBIRST
™
• 3 Year Warranty
Com
Multiplexer Bank 1
Isolation
Switch
Chan 4
Chan 1
Chan 2
Chan 3
Chan 5
Com
Isolation
Switch
Chan 4
Chan 1
Chan 2
Chan 3
Chan 5
Com
Isolation
Switch
Chan 4
Chan 1
Chan 2
Chan 3
Chan 5
Multiplexer Bank 2 Multiplexer Bank 16
Inter-Bank Linking Switch Inter-Bank Linking Switch
Switching Diagram for the 40-616A 16-Bank, 5-Channel, 1-Pole Multiplexer
The 40-616A module consists of 16 separate multiplexer banks
controlled by a PXI interface. Each bank is a 1 to 5 multiplexer
and inter-bank linking relays allow the size of a multiplexer to be
increased in multiples of 5 by joining the common terminals of
adjacent banks. Closing one linking switch produces a 10 channel
multiplexer, closing all linking switches produces an 80 channel
multiplexer.
The 40-616A can be operated as a conventional multiplexer
with break-before-make action when a new channel is selected.
Alternatively, product variants can be supplied that allow multiple
channels to be simultaneously selected.
The 40-616A channel selection congurations have been revised
from the 40-616. The 40-616A defaults to single channel selection
with multiple channel selection variants dened by use of a sufx.
The multiplexers include isolation switching that connects only
the currently active multiplexer bank to its common terminal.
This minimizes capacitive loading and leakage current in large
multiplexer systems.
The module can be cascaded for applications that require large
multiplexer systems, it is also suitable for test systems that require
a large number of signals to be switched in parallel.